60 asso t

UNITED STATES g

,j NUCLEAR REGULATORY COMMISSION

'2 WASHINGTON, D.C. 30666 4 001 o% *****l DUKE ENERGY CORPORATION DOCKET NO. 50-369 MCGUIRE NUCLEAR STATION. UNIT 1 A_MENDMENT TO FACluTY OPERATING LICENSE i

Amendment No.186 License No. NPF-9 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The appiication for amendment to the McGuire Nuclear Station, Unit 1 (the facility) Facility Operating License No. NPF-9 filed by the Duke Energy Corporatic,a, (licensee), dated August 27,1999, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations as set forth in 10 CFR Chapter I; i

B.

The facility will operate in conformity with the applicatlan, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all appi; cable requirements have been satisfied.

9909130143 990908 PDR ADOCK 05000369 P

PDR

. )

1 2.

Accordingly, the license is hereby amended to authorize a one-time extension of the f

surveillance frequency for Technical Specifications Surveillance Requirement (TSSR) 3.1.4.2 beyond the 25 percent extension allowed by TSSR 3.0.2.

(2)

Technical Soecifications The Technical Specifications contained in Appendix A, as revised through Amendment No.186, are hereby incorporated into this license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of iseuance and shall expire upon entering Mode 3 during startup, following the End of Cycle 13 refueling outage.

FOR THE NUCLEAR REGULATORY COMMISSION

(

Richard L. Emch Jr., Chief, Section 1 Project Directorate 11 Division of Licensing Project Management Office of Nuclear Reactor Regulation

Attachment:

Technical Specification Changes Date of Issuance:

September 8, 1999 I

l 1

ATTACHMENT TO LICENSE AMENDMENT NO.186 FACILITY OPERATING LICENSE NO. NPF-9 DOCKET NO. 50-369 Replace the following page of the Appendix A Technical Specifications with the attached revised page. The revised page is identified by amendment number and contain marginallines indicating the areas of change.

Remove Insert 3.1.4-4 3.1.4-4 i

Note: Amendment and revised TS pages to be filed under both docket numbers and Units 1 i

and 2 authority files to maintain document integrity.

i

Rod Group Alignmer.t Limits 3.1.4 SURVEILLANCE REQUIREMENTS (continued)

SURVEILLANCE FREQUENCY SR 3.1.4.2 Verify rod freedom of movement (trippability) by moving 92 days each rod not fully inserted in the core g 10 steps in either direction.

OR Prior to entering MODE 3 upon Unit 1 startup v

following the Unit 1 End of Cycle 13 refueling outage, SR 3.1.4.3 Verify rod drop time of each rod, from the fully withdrawn Prior to reactor position, is s 2.2 seconds from the beginning of decay of criticality after stationary gripper coil voltage to dashpot entry, with:

each removal of the reactor head j

a.

T., a 551'F; and j

1 b.

All reactor coolant pumps operating.

One time change applicable to Unit 1 only McGuire Units 1 and 2 3.1.4-4 Amendment Nos.186 (Unit 1) 167 (Unit 2) u