ML20211N698

From kanterella
Jump to navigation Jump to search
Monthly Operating Repts for Sept 1997 for San Onofre Nuclear Generating Station Units 2 & 3
ML20211N698
Person / Time
Site: San Onofre  
Issue date: 09/30/1997
From: Gibson G, Williams C
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9710170078
Download: ML20211N698 (9)


Text

.

qqu sommemou,mm d EDISON u i mov rui n mour - no,rm October 9,1997 U. S. Nuclear Regulatory Commission s

Document Control Desk Washington, D.C. 20555 Gentlemen:

Subject:

Dockei Nos. 50-361 and 50-362 Monthly Operating Reports for September 1997

{:

San Onofre Nuclear Generating Station, Units 2 and 3 I

Technical Specification 5.7.1.4 of Facility Operating Licenses NPF-10 and NPF-15 for the San Onofre Nuclear Generating Station, Units 2 and 3, iespectively, reouires

}

Scuthern California Edison to provide a Monthly Operating Report (MOR) of operating statistics and shutdown experience, including documentation of all challenges to pressurizer safety valves, for each unit. Enclosures 1 and 2 provide the September 1997 Monthly Operating Reports for Units 2 and 3, respectively. There were no challenges to pressurizer safety valves for either Unit 2 or 3.

If you have any questions, please ccntact Mr. C. E. Williams at (714) 368-6707.

Sincerely, Gregory T. Gibson Manager, Compliance Enci esures Ib lj E. W. Merschoff, Regional Administrator, N;.0 Region IV cc:

K E. Perkins, Jr., Director, Wcinut Creek Field ')ffice, NRC Region IV M. B. Fields, NRR Project Manager, San Onofre Units 2 & 3 J. A. Sloan, NRC Senior Resident inspector, San Onofre Units 2 & 3 1COC2?

IoA*$88c!o$0oSS61 R

PDH P. O. fiox !28 ll.l San Clemaue, CA 92674 0123

,.W'

1 NRC Monthly Operailng Report, September 1997 San Onofre Nuclear Generating Station, Unit 2

USNRC MONTHLY OPERATING REPORT Docket No:

50-361 SAN ONOFRE NUCLEAR GENERATING STATION Unit Name:

SONGS-2 UNIT 2 Date:

October 9,1997 September 1997 Completed by: C. E. Williams Telephone:

(714) 368-6707 Page 1 of 3 l

OPERATING DATA REPORT Wis; Desigri Electrical Rating (Not MWe)1

^

1c<

61070I:

2 Maximum Dependable Capacity (Gross MWe) 1127 3M Maximum Dependable Cepeelty (Not MWe)s sh '"9n n

s a1070s' 4

s This Month Yr to-Date Cumulative

[41 Numbpof,W$ Period aS,

(#@N 4720i!

. Sf4;56M i

$128,792iw x

5 Number of Hours Reactor Was Critical 720 4,056 95,461 (83 HoursGenerstkonlirnQhe,;

% -(720h

, f3,988i.

3 3,835s 7

Unit Reserve Shutdown Hours 0.0 0.0 0.0 68li 'Ne(Elsctrical Eneriy1Geherited (MWh)b 1786;012)

!4,209l854) i[98,'800;93 %

~

e

l USNRC MONTHLY OPERATING REPORT Docket No:

50-361 SAN ONOFRE NUCLEAR GENERATING STATION Unit Name:

SONGS 2 UNIT 2 Date:

October 9,1997 September 1997 Completed by: C. E. Williams Telephone:

(714) 368-6707 Page 2 of 3 UNIT SHUTDOWNS AND POWER REDUCTIONS 1

l NQmbers '.

8 - em aw

+,

N N/A k r

i Date N/A l

Type'(1)!

W';

f

N/A9 Duration (1)-

N/A

~

Romeon(2)i 4 '

  • ew s asW ah eds MM iN/Ai m

Mr i Method of shutting down reactor (3)

N/A LER No&@!

Cc

^^

, 69'

' GPi '

1N/A?; 'E >' M e t

System Code (4)-

N/A Component Code (5)b

~

y 'ln; M N/A % w ' s ~

4 x

l Cause and corrective action to prevent reco 'ence N/A (1) F-Forced S-scwsuied (2) Reason:

A-Equipment Failure (Explain)

B-Maintenance or Test C-Refueling D-Regulatory Restr6ction E-operator Training a Ucense Examnete F Administrative G4perational Error (Explain)

H-other (Explem)

(3) Method 1-Menual 2-Manual Scram 3 Automahc Scram 4-Conhnushon from Previous Month 5-Reduchon in the Average Deily Power Level of more then 20% from the prov60us day 6-other (Explem)

(4) IEEE Std 805-1964 (5) IEEE Std 803A 1983

USNRC MONTHLY OPERATING REPORT Docket No:

50-361 SAN ONOFRE NUCLEAR GENERATING STATION Unit Name:

SONGS-2 UNIT 2 Date:

October 9,1997 September 1997 Completed by: C. E. Williams Telephone:

(714) 368-6707 Page 3 of 3 i

t

SUMMARY

OF OPERATING EXPERIENCE FOR THE MONTH Dats Time Event 9/1/97/

[0001)

Mode 1[99,9%'reAdor powers 11'50 MWefi;132.8 EFPD3 9/7/97 0405 Commenced reactor power reduction to 80% to perform heat treat.

  • 'N

-R ;0620?

Reador powerV80N

^(n s ?@

m.

_m Initiated reactor power increase to 100% after heat treat and turbine 1550 valve testing.

2057?

Reactor power l.ati100%fMWei11533 g

9/30/97 2400 Mode 1,99.7% reactor power,1143 MWe,162.6 EFPD

)

NRC Monthly Operating Report, September 1997 l

San Onofre Nuclear Generating Station, Unit 3 l

USNRC MONTHLY OPERATING REPORT Docket No:

50 362 SAN ONOFRE NUCLEAR GENERATING STATION Unit Name:

SONGS-3 UNIT 3 Date:

October 9,1997 September 1997 Completed by: C. E. Williams Telephone:

(714) 368-6707 Page 1 of 3 OPERATING DATA REPORT 11:

Design Electrical Rating (Not MWe)/

(1080Li 2

Maximum Dependable Capacity (Gross MWe) 1127 932 Maximum Dependable Capacity (Not MWe) 9 s1080$

+

s This Month Yr-to-Date Cumulative 041 Number of Hours in Period) 17202 f ' 16,5516 v118,3432 4

Number of H(us Reactor Was Critical 720 4,300 94,593 iS:l l Hours Generator On lines nf V

$720i

< f4,149l;:

E92,683 i s

6 Unit Reserve Shutdown Hours 0.0 0.0 0.0 372 Net Electrical Energy Generated (MWh);

1788,408s

?4,410,3855 196,188,396;:

USNRC MONTHLY OPERATING REPORT Docket No:

50-362 SA'N ONOFRE NUCLEAR GENERATING STATION Unit Name:

SONGS-3

^

UNIT 3 Date:

October 9,1997 September 1997 Completed by: C. E. Williams Telephone:

(714) 368-6707 Page 2 of 3 UNIT SHUTDOWNS AND POWER REDUCTIONS

' Number!

^

' m j N/Ai Date N/A

< Type (1)1

~ s %

E lN/Ai m

Duration (Hours)

N/A Reason (2)?

s

^

EN/At Method of shutting down reactor (3)

N/A LER No ! /

MGP m

2N/AT

^

System Code (4)

N/A j

Component Code (5)l! <

e

' gm ' EN/Ai s

Cause and corrective action to prevent recurrence N/A (1) F-Forced S-Scheduled (2) Resoon:

A-Equipment FaAure (Explam)

B-Mainterence or Test C-Refueling D-Regulatory Restriction E-Operator Training & Ucense Exarnination FJ2nJnistrattve G-operational Error (Explain)

H-Other (Explain)

('l) Method 1-Manual 2-Manual Scram 3 Automatic Scram 4 Continuation from Prevmus Month f Reduction in the Averago Daily Poner Level of more than 20% from the previous day 6-Other (Expzaa)

(4) IEEE Std 805-1984 (5) IEEE Std 803A-1983 i

USNRC MONTHLY OPERATING REPORT Docket No:

50-362 SAN ONOFRE NUCLEAR GENERATING STATION Unit Name:

SONGS-3

~

UNIT 3 Date:

October 9,1997 September 1997 Completed by: C. E. Williams Telephone:

(714) 368-6707 Page 3 of 3

SUMMARY

OF OPERATING EXPERIENCE FOR THE MONTH f

Date Time Event

?9/1/9D

'0001J

-Mode 1l 99.8% reactor power /1143 MWel40.6 EFPD t 9/30/97 2400 Mode 1,100% reactor power,1140 MWe,70.3 EFPD