____

FEB 121987 Docket No. S0-285 I

Mr. R. L. Andrews Division Manager - Nuclear Production Omaha Public Power District 1623 Harney Street Omaha, Nebraska. 68102

Dear Mr. Andrews:

SUBJECT:

THERMAL SHIELD SUPPORT SYSTEM INSPECTION DEFERRAL - FORT CALHOUN STATION, UNIT NO. 1 The NRC staff has completed its review of your August 28, 1986 request, to defer the commitment made in your April 4, 1984 ' setter to inspect the thermal shield support system during the 1987 refueling outage.

The staff's Safety Evaluation is enclosed.

The staff concludes that the deferral of the thermal shield support system inspection during the 1987 refueling outago is acceptable contingent upon l

OPPD's commitment to submit additional analyses of the Internals Vibration Monitoring System, as discussed in Section 5.0 of the enclosed Safety Evaluation, within 6 months of the date of this letter.

Please provide your commitment in this regard within 30 days of the receipt of this letter.

Sincerely,

.Origimi sigma Dy Walter A.-Paulson, Project Manager PWR Project Directorate #8 Division of PWR Licensing-8

Enclosure:

Safety Evaluation cc w/ enclosure:

See next page

.DMIRIBUTIN ACRS-10 JRajan

% gelpt Fil d BGrimes NRC PDR JPartlow 0703020172 070212 L PDR WPaulson I

PDR ADOCK 05000285 PBD-8 Rdg PKreutzer o

PDR FMiraglia Gray File OGC-Bethesda NThompson EJordan TMarsh /jI g

L EB: ' k-lW PBD#8 PEj O '

P80 P

zer WPaulson;cf TMarsh' ATh dani 2

/87 2/\\ /87 2/Q/87\\

2/I 87

Mr. R. L. Andrews Fort Calhoun Station Omaha Public Power District Unit No. 1 cc:

Harry H. Voigt, Esq.

LeBoeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, NW Washington, D.C.

20036 Mr. Jack Jensen, Chairman Washington County Board of Supervisors Blair, Nebraska 68008 Mr. Phillip Harrell, Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 309 Fort Calhoun, Nebraska 68023 Mr. Charles B. Brinkman, Manager Washington Nuclear Operations C-E Power Systems 7910 Woodmont Avenue Bethesda, Maryland 20814 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Office of Executive Director for Operations 611 Ryan Plaza Drive, Suite 1000

- Arlington, Texas 76011 Harold Borchert, Director Division of Radiological Health Department of Health 301 Centennial Mall, South l

P.O. Box 95007 Lincoln, Nebraska 68509 i

..