ML20211M798

From kanterella
Jump to navigation Jump to search
Rev 8 to AR-952, Wdb Annunciator Response
ML20211M798
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 09/29/1997
From:
FLORIDA POWER CORP.
To:
Shared Package
ML20211M795 List:
References
AR-952, NUDOCS 9710150151
Download: ML20211M798 (18)


Text

- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

e q

ev 8 Effective Date INFORMATION ONLY ANNbNCIATOR RESPONSE AR-952 FLORIDA POWER CORPORATION CRYSTAL RIVER UNIT 3 WDB ANNUNCIATOR RESPONSE APPROVED BY: Interpretation tact h, IAM. Y '

(S1tNATURE ON FILE) /

O DATE: N kh

\"#

l INTERPRETATION COMTACT: Manager, Nuclear Plant Operations Support in F 18s!A H s8 h a ~

PDR

. _ _ _ ___.= __ . . _ _ _ _ . _ . _ _ _ _ . _ . - _ _ _ - . - __ . _ . _ . . . _ _ _ _ . _ .

i I

TABLE OF CONTENTS SECTION PAGE L O PU R P0 S E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , 1

2.0 REFERENCES

.............................................................. 1 2.1 IMPLEMENIING REFERENCES ............................................ 1 2.2 DEVELOPMENibt REFERENCES ........................................... 1 i

3 . 0 PERSONNEL INDOCTRINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 4.0 INSTRUCTIONS............................................................ 1 5.0 FOLLOW-UP ACTIONS..................................,....................

1

. ENCLOSURE i- 1 An n u n ci ato r Re s Pon s e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 i

(

4 d

J d

4 4

J

(

A d

E J '

t

.i

-AR-952 Rev. 8 Page i

1.0 PURPOSE 1.1 Establish a reference document for each Annunciator Window on the .

WD-WP Lampbox.

~~

1.2 Establish operator actions for valid Annt.aciator alarms on the WD-WP Lampbox.

1.3 Establish a referance to other procedures which address operator actions for valid Annunciator alarms on the WD-WP Lampbox.

2.0 REFERENCES

l.

2.1 IMELEMENTING REFERENCES None 2.2 DEVELOPMENTAL REFERENCES 2.2.1 INPO 90-021, Good Practice OP-217, Alarm Response Procedures 2.2.2 Annunciator Window Engraving Drawing E-224-050.

3.0 PERSONNEL INDOCTRINATION None 4.0 INSTRUCTIONS 4.1 Respond to alarms on the WD-WP Lampbox as indicated on Enclosure 1 Annunciator Response.

5.0 FOLLOW-UP ACTIONS None O

AR-952 Rev. 8 Page 1

O -

ENCLOSURE 1 (Page 1 of 15)

  • RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-1-2 B-1-2 DECAY HEAT PIT SUMP LEVEL EXTRA HIGH INDICATED CONDITION:

- LEVEL OF DH SUMP 3B> 3' REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- DH PIT SUMP PUMP 3B (WDP-38) AUTO-START ALARM DH PIT SUMP PUMP 3B RUN INDICATING LAMPS -

- SUMP LEVEL INDICATION ON WD PANEL OPERATOR ACTION FOR A VALID ALARM:

O'

- CHECK THAT DH SUMP PUMP 3B IS RUNNING

- CHECK DH SUMP PUMP 3B VALVE LINEUP

- INVESTIGATE DRAINS TO DH PIT SUMP FOR ABNORMAL DRAINAGE DISCUSSION:

THIS ALARM IN CON] UNCTION WITH WDP-3B RUNNING COULD INDICATE A LARGE LEAK IN THE 'B' DH PIT. NOTIFY CORTROL ROOM OPERATOR IMMEDIATELY,

REFERENCES:

DWG 208-060 WD-10 SENSING ELEMENT: WD-134-LS O

AR-952 Rev, 8 Page 2

[] ENCLOSURE 1

() (Page 2 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-1-3 B-1-3

- ~~~~

AUX BLDG SUMP PUMP 3A AUTO-START INDICATED CONDITION:

- AUX BLDG SUMP LEVEL >2.5'

- AUX BLDG SUMP PUMP 3A (WDP-4A) IS SELECTED REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- PUMP RUN INDICATING LAMPS ON WD PANEL .

- POSSIBLE AUX BLDG SUMP LEVEL EXTRA HIGH ALARM

- PUMP DISCHARGE PRESSURE ON WD PANEL

- SUMP LEVEL INDICATOR ON WD PANEL OPERATOR ACTION FOR A VALID ALARM:

- NORMAL FUNCTION ALARM. IF FREQUENCY OF AUTO-STARTS IS EXCESSIVE, CHECK VALVE LINEUP OF SYSTEMS DRAINING TO SUMP AND DETERMINE SOURCE.

DISCUSSION:

IF WDP-4A RUNS FOR AN EXCE a vE PERIOD OF TIME, THIS COULD INDICATE PUMP DEGRADATION OR A LARGE LEAK IN THE AUXILIARY BUILDING. NOTIFY CONTROL ROOM OPERATOR IF RUN TIME IS EXCESSIVE.

REFERENCES:

DWG 208-060 WD-11 SENSING ELEMENT: WD-132-LS O

AR-952 Rev. 8 Page 3

gQ ENCLOSURE 1

(,/ (Page 3 of 15)

RA0 WASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-1-4 B-1-4

-- ~'"~--

AUX BLDG SUMP PUMP 3A TRIP INDICATED CONDITION:

- PUMP AUTO-STOPS IF AUX BLOG SUMP LEVEL <1.5' REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- PUMP RUN INDICATING LAMPS ON WD PANEL

- SUMP LEVEL INDICATOR ON WD PANEL -

OPERATOR ACTION FOR A VALID ALARM:

- NORMAL FUNCTION ALARM INVESTIGATE VALVE LINEUP / SWITCH POSITION IF AUX BLDG SUMP LEVEL EXTRA HIGH ALARM EXISTS.

DISCUSSION:

THIS IS AN EXPECTED ALARM IF WDP-4A IS MANUALLY STARTED AND AUXILIARY BUILDING SUMP LEVEL <1.5'. INVESTIGATE ANY OTHER REASON FOR PUMP TRIP,

REFERENCES:

DWG 208-060 WD-11 SENSING ELEMENT: WD-132-LS AR-952 Rev. 8 Page 4

t

(}/ ENCLOSURE _1 (Page 4 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-1-5 B-1-5 WASTE GAS COMP SEAL LEAK DR TK LOW LEVEL INDICATED CONDITION:

- LOW LEVEL OF 8" REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- POSSIBLE RMA-2(G) OR RMA-3 ALARM OPERATOR ACTION FOR A VALID ALARM:

- BLEED AIR OFF WDV-1030 TO CLOSE '

DISCUSSION:

WDV-1031 SHOULD BE USED TO MANUALLY CONTROL DRAIN POT LEVEL IF WDV-1030 FAILS TO CONTROL,

REFERENCES:

DWG 208-060 WD-135 SENSING ELEMENT: WD-357-LS2 O

AR-952 Rev. 8 Page 5

4 ENCLOSURE 1 (Page 5 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-1-6 B-1-6 AUX BLDG SUMP PUMP 3B AUTO START INDICATED CONDITION:

- AUX BLDG SUMP LEVEL >2.5'

- AUX BLDG SUMP PUMP 38 (WDP-48) IS SELECTED REDUNDANT INDICATION WhICH WILL VERIFY ALARM:

- PUMP RUN INDICATING LAMPS ON WD PANEL -

- POSSIBLE AUX BLDG SUMP LEVEL EXTRA HIGH ALARM

- PUMP DISCHARGE PRESSURE ON WD PANEL

- SUMP LEVEL INDICATOR ON WD PANEL OPERATOR ACTION FOR A VALID ALARM:

- NORMAL FUNCTION ALARM. IF FREQUENCY OF AUTO-STARTS IS EXCESSIVE, CHECK

-VALVE LINEUP OF SYSTEMS DRAINING TO SUMP AND DETERMINE SOURCE.

DISCUSSION:

IF WDP-4B RUNS FOR AN EXCESSIVE PERIOD OF TIME, THIS COULD INDICATE PUMP DEGRADATION OR A LARGE LEAK IN THE AUXILIARY BUILDING. NOTIFY CONTROL ROOM IF RUN TIME IS EXCESSIVE.

REFERENCES:

DWG 208-060 WD-12 SENSING ELEMENT: WD-132-LS 4

k./

AR-952 Rev. 8 Page 6

_ = - .

[ ENCLOSURE 1

\. (Page 6 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-1-7 B-1-7


AUX BLDG SUMP PUMP 3B TRIP INDICATED CONDITION: l

- PUMP AUTO-STOPS IF AUX BLDG SUMP LEVEL <1.5' 4

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- PUMP RUN INDICATING LAMPS ON WD PANEL

- SUMP LEVEL INDICATOR ON WD PANEL -

OPERATOR ACTION FOR , VALID ALARM:

- NORMAL FUNCTION ALARM INVESTIGATE VALVE LINEUP / SWITCH POSITION IF AUX BLDG SUMP LEVEL EXTRA HIGH ALARM EXISTS.

DISCUSSION:

THIS IS AN EXPECTED ALARM IF WDP-4B IS MANUALLY STARTED AND AUXILIARY BUILDING SUMP LEVEL <1.5'. INVESTIGATE ANY OTHER REASON FOR PUMP TRIP.

REFERENCES:

DWG 208-060 WD-12 SENSING ELEMENT: Wr'-132-LS f~~

s AR-952 Rev. 8 Page 7

/7 ENCLOSURE 1 L/ (Page 7 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-1-8 B-1-8


WASTE GAS SAMPLING ANALYZER PANEL IN ALARM INDICATED CONDITION:

- LOSS OF 120 VAC POWER TO GAS ANALYZER PANEL l

' REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- POWER INDICATING LAMP ON PANEL IS OUT

- GAS FLOW <0.2 SLPM .

l OPERATOR ACTION FOR A VALID ALARM:

- CHECK PANEL POWER SUPPLY SWITCH h

d - CHECK 480 VAC SUPPLY BREAKER ON REACTOR MCC 382

- CHECK PUMP OPERATION AND VALVE ALIGNMENT DISCUSSION:

THIS ALARM MAY INDICATE A NEED TO PERFORM AN ALTERNATIVE MEANS OF SAMPLING. NOTIFY CONTROL ROOM OPERATOR IMMEDIATELY.

1

REFERENCES:

DWG 208-060 WD-131, WD-135 SENSING ELEMENT: PF RELAY WD-21-FIS i

O AR-952 Rev. 8 Page 8 4

O ENCLOSURE 1 (Page 8 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-2-1 B-2-1


AUX BLDG SUMP LEVEL

______ EXTRA HIGH INDICATED CONDITION:

- LEVEL OF AUX BLDG SUMP >5.5' REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- AUX BLDG SUMP PUMP 3A AND/OR 3B AUTO-START ALARMS

- SUMP PL'MP INDICATING LAMPS ON WD PANEL -

- SUMP LEVEL INDICATOR ON WD PANEL 4

OPERATOR ACTION FOR A VALID ALARM:

O- - CHECK THAT AUX BLDG SUMP PUMPS 3A AND/OR 3B ARE RUNNING

- CHECK SUMP PUMP VALVE LINEUP

- DETERMINE SOURCE OF WATER INTO SUMP DISCUSSION:

THIS ALARM IN CONJUNCTION WITH AN AUXILIARY BUILDING SUMP PUMP ALREADY RUNNING MAY BE AN INDICATION OF EITHER PUMP DEGRADATION OR A LARGE LEAK IN THE AUXILIARY BUILDING. NOTIFY CONTROL ROOM OPERATOR IMMEDIATELY.

REFERENCES:

DWG 208-060 WD-11 SENSING ELEMENT: WD-132-LS1 AR-952 Rev. 8 Page 9

7 3

.t-) ENCLOSURE 1 (Page 9 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-2-2 B-2-2


WASTE TRANSF Pl'MP 3A

_____ AUTO START FAILURE INDICATED CONDITION:

l -- MUV-541 BLEEDOPEN TANK 3A AND SELECTED ON FEED SELECT SWITCH (AND PULLED)

- WASTE TRANSFER PUMP 3A (WDP-5A) NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- PUMP RUN INDICATING LAMPS ON WD PANEL

- MUV-103 INDICATING LAMPS IN CONTROL ROOM

/3 w ,! OPERATOR ACTION FOR A VALID ALARM:

- CHECK CORRECT POSITIONS, VALVE LINEUP, SWITCH POSITIONS AND FEED PERMISSIVE CIRCUITS FOR DISCUSSION:

THIS ALARM WILL OCCUR IF WDP-5A IS SHUT DOWN FOR ANY REASON WHILE ATTEMPTING TO ADD TO THE RCS USING WDT-5A, NOTIFY CONTROL ROOM OPERATOR OF LOCAL INDICATIONS CONCERNING THE REASON FOR WDP-5A SHUTDOWN.

REFERENCES:

DWG 208-060 WD-13 l SENSING ELEMENT: 42BIELAYF13MUV-541 J

AR-952 Rev. 8 Page 10

O ENCLOSURE 1 (Page 10 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-2-3 B-2-3 WASTE TRANSF PUMP 3A

_ ---- TRIP INDICATED CONDITION:

- PUMP CONTROL SWITCH IN NOR-AFT-START POSITION AND PUMP NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- PUMP MOTOR OVERCURRENT +

- PUMP STARTED LOCALLY THEN SELECTED FOR FEED g OPERATOR ACTION FOR A VALID ALARM:

- CHECK FOR PUMP MOTOR OVERLOAD TRIP CONDITION

- CHECK VALVE LINEUP AND SWITCH POSITION

- CALL CGNTROL ROOM TO SEE IF PUMP SELECTED FOR FEED DISCUSSION:

IF WDP-5A WAS RUNNING FOR RCBT RECIRCULATION, A NEW SAMPLE REQUEST WILL HAVE TO BE CENERATED AFTER THE CAUSE OF THE PUMP TRIP IS DETERMINED AND RESOLVED,

REFERENCES:

DWG 208-060 WD-13, WD SENSING ELEMENT: CS/SC+CS/0 42B O

AR-952 Rev. 8 Page 11

4 q

ENCLOSURE _1 (Page 11 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-2-4 B-2-4 l '

WASTE TRANSF PUMP 3B AUTO START FAILURE INDICATED CONDITION:

] - MUV-541 OPEN AND- BLEED TANK 3B SELECTED ON FEED SELE

- WASTE TRANSFER PUMP 3B (WDP-58) NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY ALARM: ,

- PUMP RUN INDICATING LAMPS ON WD PANEL

- MUV-103 INDICATING LAMPS IN CONTROL ROOM Os OPERATOR ACTION FOR A VALID ALARM:

- CHECK VALVE LINEUP, SWITCH POSITIONS AND FEED PERMISSIVE CIRCU FOR CORRECT POSITIONS.

DISCUSSION:

ATTEMPTING TO ADD TO THE RCS USING WDP-iB OF LOCAL INDICATIONS CONCERNING THE REASON FOR WDP- .

REFERENCES:

DWG 208-060 WD-14 l  !

SENSING ELEMENT: 428 RELAY F2 3MUV-541 i

a.

l S.

A AR-952 Rev. 8 Page 12

4 O ENCLOSURE 1 (Page 12 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE _ _ _ ' WD-WP-2-5 8-2-5

--- -~~~

WASTE TRANSF PUMP 38

--- -- TRIP INDICATED CONDITION:

- PUMP CONTROL SWITCH IN NOR-AFT-START POSITION AND PUMP NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- PUMP MOTOR OVERCURRENT .

- PUMP STARTED LOCALLY 1 HEN SELECTED FOR FEED OPERATOR ACTION FOR A VALID ALARM:

- CHECK FOR PUMP MOTOR OVERLOAD TRIP CONDITION u -

CHECK VALVE LINEUP AND SWITCH POSITIOV CALL CONTROL ROOM TO SEE IF PUMP SELECTED FOR FEED DISCUSSION:

IF WDP-5B WAS RUNNING FOR RCBT RECIRCULATION, A NEW SAMPLE REQUEST WILL HAVE TO BE CENERATED AFTER THE CAUSE OF THE PUMP TRIP IS DETERMINED AND RESOLVED.

REFERENCES:

DUG 208-060 WD-14, WD-73 SENSING ELEMENT: CS/SC+CS/0 42B a

O AR-952 Rev. 8 Page 13

4 i

ENCLOSURE 1 (Page 13 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-C-2-6 B-2-6

~~~'~--- - WASTE TRANSF PUMP 3C AUTO START FAILURE j

INDICATED CONDITION:

I

- BLEED TANK 3C SELECTED ON FEE 0 SELECT SWITCH (AND PULLED)

\ - MUV-541 OPEN AND

- WASTE TRANSFER PUMP 3C (WDP-50 NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- PUMP RUN INDICATING LAMPS ON WD PANEL

- MUV-103 INDICATING LAMPS IN CONTROL ROOM

q OPERATOR ACTION FOR A VALID ALARM:

1

- CHECK VALVE LINEUP, SWITCH POSITIONS AND FEED PERMISSIVE CIRCUITS FOR CORRECT POSITIONS.

DISCUSSION:

THIS ALARM WILL OCCUR IF WDP-SC IS SHUT DOWN FOR ANY REASON WHILE ATTEMPTING TO ADD TO THE RCS USING WDP-SC. NOTIFY CONTROL ROOM OPERATOR OF LOCAL INDICATIONS CONCERNING THE REASON FOR WDT-SC SHUTDOWN.

REFERENCES:

DWG 208-060 WD-15 SENSING Et.EMENT: 42B RELAY F3 3MUV-541 4

-O AR-952 Rev. 8 Page 14

'l

  • l 4

?

ENCLOSURE 1 ON (Page 14 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-2-7 B-2 ----- WASTE TRANSF PUMP 3C


TRIP INDICATED CONDITION:

PUMP CONTROL SWITCH IN NOR-AFT-STGT POSITION AND PUMP NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY A ARM:

PUMP MOTOR OVERCURRENT .

PUMP STARTED LOCALLY THEN SELECTED (OR FEED OPERATOR ACTION FOR A VALID ALARM:

O - CHECK FOR PUMP MOTOR OVERLOAD TRIP CONDITION

- CHECK VALVE LINEUP AND SWITCH POSITION

- CALL CONTROL ROOM TO SEE IF PUMP SELECTED FOR FEED DISCUSSION:

IF WDP-5C WAS RUNNING FOR RCBT RECIRCULATION, A NEW SAMPLE REQUEST WILL HAVE TO BE GENERATED AFTER THE CAUSE OF THE PUMP TRIP IS DETERMINED AND RESOLVED.

REFERENCES:

DWG 208-060 WD-15. WD-74 SENSING ELEMENT: CS/SC+CS/0 42B AR-952 Rev. 8 Page 15

1

(

ENCLOSURE 1 O'-

(Page 15 of 15)

RADWASTE DISPOSAL ANNUNCIATOR RESPONSE WD-WP-2-8 B-2-8

--~""""---- MISC RAD WASTE TRANSF PUMP 3A TRIP INDICATED CONDITION:

- PUMP CONTROL SWITCH IN NOR-AFT-START POSITION AND WDP-6A NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

- PUMP RUN INDICATING LAMPS ON WD PANEL .

OPERATOR ACTION FOR A VALID ALARM:

- CHECK VALVE LINEUP AND DETERMINE CAUSE OF PUMP MOTOR OVERLOAD TRIP

( CONDITIONS DISCUSSION:

-THIS PUMP DOES NOT AUTO SHUT DOWN ON LOW MISCELLANEOUS WASTE STORAGE TANK (MWST) LEVEL. IF PROCESSING TO THE ECST'S, CARE SHOULD BE TAKEN TO PREVENT RUNNING WDP-6A WITH NO LEVEL IN THE MWST.

REFERENCES:

DWG 208-060 WD-16 SENSING ELEMENT: CS/SC+CS/0 42B

\

n)

L AR-952 Rev. 8 Page 16 (LAST PAGE)