Mi p[- Q9(b;gogy REGISTilY Of RADIOACTIVE SEALED-SOURCES'AND DEVICES

' SAFETY EVALVATION OF DEVICE-(Corrected Page).

~

OUlI0 5 19g9 NO. ::

NR192D1050-DATE:

tiay 27.1966-

,PAGE-I'0F 3-DEVICE TYPE:

Gauge Source Holder f100EL: 02-0123 NANUFACTURER/ DISTRIBUTOR:-

Brun Corporation Columbus, OH MANUFACTURER / DISTRIBUTOR:

SEALED SOURCE MODEL DESIGNATION:

Nuclear _ Chicago 850?33 J

ISC'E: Cesium-137 MAXIMUM ACTIVITY:

50 millicuries 4

i.

[

LEAK TEST'FRE00ENCY:

PRINCIPAL USE:- (D) camma cause t

CUSTOM OEVICE:

YES

'X NO-e I

9710100054 970929 PDR RC i

-SSD PDR.

l 3

N w

.c REGISTRYLOF RADI0 ACTIVE SEALED SOURCES AND DEVICES

= SAFETY-EVALUATION OF-DEVICE NO.:

NR1920105U DATE:-

May 27, 1966' PAGE 2 0F 3-

"DEVltE TYPE:

Gauge Source Holder DESCRIPTION:

The device-is cylindrical in sha.pe, 7-5/16 inches in height, and 4-1/2 inches in aiameter with a 4-3/4 inch square base plate.

The steel base plate, 1/4 of an.

inch thick,. includes 4 mounting holes 5/16 inch in diameter.

The steel cylinder i

has.a 1/8 inch wall and a top = plate 3/16 inen thick.

These components are joined-l by welds.

~

The cylinder is-filled with lead shielding, which includes two cavities.

A rectangular beam port,1-1/4 inches by 1-5/16 inches at the outer surface of the device, tapers to its apex at the approximate position of the source in the "on" position.- The other cavity consists of a vertical hole lined with 1/2 inch inside diameter steel tubing.-

This hole.is 5-1/4 inches deep and is located on the vertical axis of the cylinder.

The-source is mounted at the bottom end of a source rod which is raised a distance of 2-7/16 inches to expose the source at the apex of the beam port.

The bottom portion-of the source rod, 3/8 inch in diameter and 2-1/4 inches in length, consists of a Mallory-1000 meta).

This is threaded to the upper portion of:the source rod consisting.of a 1/4 inch square, steel piece topped by.a knob. A stop secured to the: top plate by two screws has a 17/64 inch square hole allowing passage of the 1/4 inch square portion of the rod only.

This prevents removal of the source and positions it at the apex of the bean port..

A pin is used to " lock" the source in either the "on" or "off" position. -The pin j

is inserted through a hole in the stop and a hole in the source rod. A cable passing through the locking pin and looped at each end may be padlocked in place so as to prevent movement of_the source.

LABELING:.;

A metal label =3-3/8 inches b'y 2-3/16 inches attached to the outside of the device.

- 180* :from the radiation ' beam _ bears the following:

" CAUTION:-'RADI0 ACTIVE MATERIAL Cesium-137J 50 mc-Date of Measurement

~ Model: 02-0123 BRUN CORPORATION, COLUMBUS, OHIO" r

1

-~

b g% [

We,,

' REGISTRY OF RADI0 ACTIVE ~ SEALED' SOURCES AND DEVICES SAFETY EVALUATION 0F DEVICE'

' ' NO.:

NR1920105U DATE:

May 27, 1966 PAGE 3 0F 3

' DEVICE' TYPE:

Gauge Source Holder LABELING (CONT'0):

-The-label is-basically yellow in color with black lettering and a magenta 3

radiationLsymbol.

A= label attached to the device, opposite the beam port, indicates the source position:as " SOURCE OPEN" and " SOURCE CLOSE" by arrows.

EXTERNAL RADIATION LEVELS:

The radiation-levels at one foot from the surface of the device containing 50 millicuries of cesium-137 are generally less than 1.5 mr/hr with a maximum of about 2-1/2 mr/hr at a inot from the top surface of the device.

This includes radiation levels for both +he "on" and "off" positions of the source.

I LIMITATIONS AND/0R OTHER CONSIDERATIONS OF USE:

The Brun Corporation has ststed that they will install, survey, and leak test each device.-.They have also indicated a willingness to provide maintenance and repair services _ including relocation.

The Brun Corporation has not described any guards or shielding inherent in the-device installation.- Therefore, each individual applicant's proposed use of the device will have:to be individually evaluated.

ISSUING AGENCY:

U.Si Nuclear Regulatory' Commission 4

y x

,.,-,