REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.

NR-8094-D-805-S DATER September 29, 1997 Eh9E 1 OF 4 DEVICE TYPEr Gauge Source Holder MODELt 02-0123 MANUFACTURER / DISTRIBUTOR:

Brun Sensor Systems, Inc.

1150 West Third Street Columbus, OH 43212 SEALED SOURCE MODEL DESIGNATION 1 Nuclear Chicago 890233 ISOTOPE:

MAXIMUM ACTIVITY:

Cesium-137 50 millicuries (1.85 GBq)

LEAK TEST FREOUENCYr 6 months PRINCIPAL USE:

(D) Gamma Gauge CUSTOM DEVICE:

YES X

MO 9710100044 970929 PDR RC SSD PDR

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO..l NR-8094-D-805-S DATE: September 29, 1997 PAGE 2 OP 4 DEVICE TYPE:

Gauge Source Holder DESCRI!.10N:

The device is cylindrical in shape, 7-5/16 inches (185.7 mm) in height, and 4-1/2 inches (114.3 mm) in diameter with a 4-3/4 inch (120.7 mm) square base plate.

The steel base plate, 1/4 inch

( 6. 4 mm) thick, includes 4 mounting holes 5/16 inch (7.9 mm) in diameter.

The steel cylinder has a 1/8 inch (3.2 mm) wall and a top plate 3/16 inch (4.8 mm) thick.

These components are joined by welds.

The cylinder is filled with lead shielding, which includes two cavities.

A rectangular beam port, 1-1/4 inches (31.8 mm) by 1-5/16 inches (33. 3 mm) at. the outer surface of the device, tapers to its apex at the approximate position of the source in the "on" position.

The other cavity consists of a vertical hole lined with H_ inch (12.7 mm) inside diameter steel tubing.

This hole is 5-1/4 inches (133.4 mm) deep and is located on the vertical axis of the cylinder..The source is mounted at the bottom end of a source rod which is raised a distance of 2-7/16 (61.9 mm) inched to expose the source at the apex of the beam port.

The bottom portion of the source rod, 3/8 (9. 5 mm) inch in diameter and 2-1/4 (57.2 mm) inches in length, consists of a Mallory-1000 metal.

This is threaded to the upper portion of~the source rod consisting of a 1/4 inch (6.4 mm) square, steel piece topped by a knob.

A stop secured to the top plate by two screws has a 17/64 inch (6.7 mm) square hole allowing passage of the 1/4 inch square portion of the rod only.

This prevents removal of the source and positions it at the apex of the beam port.

A pin is used to " lock" the source in either the "on" or "off" position.

The pin is inserted through a. hole in the stop and a hole in the source rod.

A cable passing through the locking pin and looped at each end may be padlocked in place to prevent

- movement of the source.

I i

n..

REGISTRY OF RADIOACTIVF SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.: NR-8094-D-805-S DATEt September 29, 1997 PAGE 3 OF 4 DEVICE TYPE:

Gauge Source Holder LABELING:

A metal label 3-3/8 inches (85,7 mm) by 2-3/16 inches (55.6 mm),

attached to the outside of the device 180" from the radiation beam bears the following:

CAUTION:

RADIOACTIVE MATERIAL Cesium-137 mc Date of Measurement Model No.

02-0123 BRUN CORPORATION, COLUMBUS, OHIO The label is basically yellow in color with black lettering and a magenta radiation symbol.

A label attached to the device, opposite the beam port, indicates the source position as " SOURCE OPEN" and " SOURCE CLOSE" by arrows.

EXTERNAL RADIATION LEVELSt The radiation levels at one foot (304. 8 mm) from the surface of the device containing 50 millicuries (1.85 GBq) of cesium-137 are generally less than 1.5 mR/hr (15 ySv/hr) with a maximum of about 2-1/2 mR/hr (25 pSv/hr) at a fcot from the top of the surface of the device.

This includes radiation levels for both the "on" and "off" positions of the source.

LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USEt Handling, storage, use, transfer, and disposal: To be determined by the licensing authority.

The device shall be leak tested at intervals not to exceed 6 months using techniques capable of detecting 0.005 microcurie (185 Bq) of removable contamination.

REVIEWER NOTE:

The Brun Corporation had stated that they would install, survef, and leak test each device.

They had also indicated a willingness to provide maintenance and repair services including relocation.

i L

[

l REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE l

HQ 1 NR-8094-D-805-S DATE: September 29, 1997 PAGE 4 OF 4 i

DEVICE TYPE 1 Gauge Source Holder l

LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE (cont.)t REVIEWER NOTES-The Brun Corporation had not described any guards or shielding inherent in the device installation.-

Therefore, each individual application proposed use of the device will have to be individually evaluated.

SAFETY ANALYSIS

SUMMARY

This device was originally approved for licensing purposes on May, 27, 1966, by the Atomic Energy Commission (AEC).

The Model 02-0123 Gauge Source Holder is no longer manufactured and distributed by Brun Sensors Systems.

Brun Sensor Systems materials license terminated January 23, 1973, and the company was acquired by Industrial Nucleonics that same year.

There is insufficient information on file for this device to perform a safety evaluation.

Therefore, this certificate is being taken to inactive status without further review based on the original review and approval issued by the AEC.

REEERENCES' The-following supporting documents for the Model 02-0123 Gauge Source Holder are hereby incorporated by reference and are made a part of'this registry document.

Brun Corporation's application dated March 29, 1966.

Brun Corporation's letter dated March 21, 1966, and May 2, 1966.

ISSUING AGENCY:

U.S. Nuclear Regulatory. Commission

. c.

.,...______.a_

. c.

u,,._..

.--- _....,u. _._ _ _ _ _.

pe nso 8%

UNITED STATES y*

g j

NUCLEAR REGULATORY COMMISSION p

g WAf HINGToN, D.C. Po66HXct

'9,

September 29, 1997 NOTE TO:

FILES LISTED BELOW MICHELE BURGESS 79/l[

FROM:

DATE:

SEPTEMBER 29,1997 Brun Sensor Systems' materials license terminated January 23,1973, and the company was acquired by industrial Nucleonics that same month.

The following devices were originally approved for licensing purposes by the Atomic Energy Commission (AEC) during the late '60s and early '70s. These devices are no longer manufactured and distributed bv Brun Sensor Systems.

There is lasufficient information on file for th6se device to have performed a safety evaluation.

Therefore, these registration certificates have been taken to inactive status without further review based on the original review and approval issued by the AEC.

Old Reaistration Number inactive Reaistration Number NR 192 D-101 U NR 8094 D-801 S NR 192 D 102 U NR 8094 D 802 S NR 192 D 103-U NR 8094 D-803-S NR 192 D 104 U NR 8094 D 804 S NR 192 D 105 U

NR-8094-D-805 8 NR 192 D 106 S NR 8094 D 806-S NR 192-D 107 U NR-8094 D-807 S NR 192 D-108 U NR-8094-D-808 S NR 192 D 109-U NR 8094 D-809-S NR 192 D 110-U NR 8094 D-810-S NR 192 D-111 U NR 8094 D-811-S "For edditional information conceming Brun Sensor Systems and these devices, including drawings, refer to the NRC archive file: Job R023, Shelf 10196, Box 05.

}

l IllRIlljllllIlllli A-Tic) vuo 3 3 Ajy'-

PAGE1 NRC FORM $67 U. 8, NUCLEAR REGULATORY COMMISS40N ite4 REQUEST FOR A SEALED SOURCE OR yp/97 DEVICE EVALUATION INSTRUCTIONS: Send true request AND a copy of en reisted letters /appicatsono and drawings to: The Seeled Source Safety Section, ATTN: Ctwof, OWFN Mel Stop 6 H3. Chav the License Tracking System milestone to 19 and esenen to revlower code I-5.

NOTE: Retain a copy of this request with the apphcation and background files.

REGION / LOCATION:

RwvEs TER br% *1 1' " 4. -

1, ; C11~

]l R ll R ll1 R IV RV HQ LFDCB treuuuHE NVWutR DAtt TYPE OF ACTION REQUESTED (Check as appropriate)

J Arncurt s NAME SOURCE REVIEW AMENDMENT OF

/

REGISTRATION SHEET N MBER )

MAIL CONTROL NUMBENS)

DEVICE REVIEW g,,,.

LaTvER/AIMCPION DATE LcENSE NLTABE R(S)

CUSTOM REVIEW a sr L e) n ) s i9 L c1 i s 't V Louen Nta qy p n r s' f w j W.

,,.y

(, (.mls clt y ) E'

11, s u

.a FOR SSES USE ONLY REvitwtse stouE.L NUMilERS NUWeER ASSIONED 9)7-te/,

um,

-,.s

.v.

v.-

DatE Rtztiv00.

DATE ASSaGNLD DATE TO FEE 8 N/[

/

TYPE OF ACTION (Ind6cate the number of each type)

/

/

,{ COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPUCANT(CUSTOM)

SOURCE (9C)

DEVICE (9A)

SOURCE (90)

DEVICE (90)

NEW NEW NEW NEW AMENDMENT AMENDMENT AMENDMENT AMENDMENT N ING ACTm REQuRED W mown OF EQU D NO

] DTHER (Spec #y)

TOTAL NUMBER OF NOTES I g,s,1 p

REVIEW HOURS

(, f *7 NUMBER OF A1 d '

t' ' " *

  • DEFICIENCY LETTERS

~

NUMBER OF DEFICIENCY CALLS FOR 94LLING PURPOSES ONLY j NEW REGISTRATION -

gRODUCT INACTM -

NAME CHANGE ADDRFSS CHANGE ADD TO BILUNG REMOVE FROM BILLING FOR FEE USE ONLY vvet os ein FEE CATEGORY

~

]9A GB 9C 90 mw Roctivtp 6L cHEcM NUMBER MATANN UPDATED

.g [

gjM

- AS REQUIRED part w cHeca

(' '

Loo S $M j MATSYS UPDATED

}4h M AS REQUIRED j

_o.,

g om -

De DI h Wecfidtwter pea

- _.