Text
,
- o TECHNICAL SPECIFICATIONS Rhode Island Nuclear Science Center Docket 50193, License R 95 P.evision 1 reactor operation, fuel movement and handling of radioactive materials in the reactor building.
Objective:
To assure that radiation monitoring equipment is-available 'for evaluation of radiation conditions and that the release of airborne radioactive material is - maintained below the limits established in 10CFR20.
-)
Specification:
1.
-When the reactor. is operating, gaseous and I
particulate sampling of the stack effluent shall be monitored by a stack monitor with a readout in the control room.
The particulate activity monitor and the l
gaseous activity ' monitor for the facility j
exhaust stack shall. be operating..
If either unit is out of service for more than one shift (6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />), either. the reactor. shall be shut down or the _ unit. shall.be replaced by one of 3
comparable monitoring capability.
- 2. - When the reactor : is operating, at-least one constant air monitoring unit (Table 3.2.11) located in the confinement building shall be operating.
Temporary shutdown of-this unit shall be limited as in 3.7.1 above.
i j
3.
The reactor shall not be continuously
- operated without a minimum of one area radiation monitor (Table - 3.2.8) on the s.
experimental-level of the reactor building and -
one area monitor (Table 3.2.6) over the L
reactor pool (reactor bridge) operating and capable of warning personnel of high radiation levels.
1.
-9710070283 971002 I
PDR ADOCK 05000193:
Page 29 Admendment 24 P
PDR s
~ -