{{#Wiki_filter:_____________________-___ _ __ _ __ kWbb hO, ISHAM. LINCOLN & BEALE COUNSELORS AT LAW DC(K[T(* UiNPC THREE FIRST NATIONAL PLAZA CMCAGO.ILLINotS 60602 EDWmRD $ ISHAM. 1872-1902 TELEPHONE 312 558-7500 EET ROBERT T LINCOLN 1872188g TELEX:2 5288 CHCAGO.lLLINOIS 60603 WILLIAM G EIEALE. 1885 1923 312 558 5500 OCb QNhCTIC dVENUE. N W. BY M a W HNGT N. 20036 202 833-9730 TO CALL WRITER DIRECT (312) 558-BY MESSENGER october-31, 1986 Robert Guild, Esq. ' Business and Professional People for the Public Interest 109 North Dearborn Street Suite 1300 Chicago, Illinois 60602 Re: In the Matter of Commonwealth Edison Company (Braidwood Station, Units 1 and 2),. . Docket Nos. 5 0-4 5 6 an~d 5 0-4 5 7~/~) t-.
Dear Bob:
Enclosed are revised copies of Attachments 2C (Kaushal-3), 2C (Kaushal-4), Attachment 2C (DelGeorge-1 through -6) and Ken Kostal's testimony, which include the results of the latest recount of weld discrepancies and discrepant welds by Sargent & Lundy. I still owe you the corresponding changes to the text of Dr. Frankel's testimony and Mr. DelGeorge's_ testimony. It is my understanding that the substance of their testimony remains the same and only some numbers will change. I also enclose a nine page summary of the primary reasons for the S&L weld discrepancy count changes. On Monday I will provide you and the Staff with a marked up copy of C (Kaushal-3), Attachment 2C (Kaushal-4) and a a computer listing similar to Intervenors' Exhibit 141 which Jg will indicate each change which has been made. As I' informed mom you last Friday, all of S&L's calculations and work papers 38 are'available for your review at S&L's offices. In addition, we will make Mr.Kostal available for an interview early next week at your convenience if you need f r explanation of vu the changes, j $8 Sincere i rn { O PhiEY . dteh PPS:es t m1F enc. t cc Service List w/ enc. psa3 i
2
SUMMARY
OF CHANGES IN WELD DISCREPANCIES AND DISCREPANT WELDS IHE CHANGES
- RESULTING FROM THE OCTOBER 1986 RECOUNT'0F WELD DISCRE-PANCIES AND DISCREPANT WELDS ARE SUMMARIZED BELOW:
WELD DISCREPANCIES DISCREPANT WELDS C0H 1 1 CBP -1 0 CPH 265 343 EIN 159 67 APPROXIMATELY 70% OF THE CHANGES IN THE WELD DISCREPANCIES IN THE CPH CONSTRUCTION CATEGORY ARE DUE TO THE 6. TYPICAL SITU-ATIONS ILLUSTRATED ON PAGES 2-7.- APPROXIMATELY 65% OF THE CHANGES IN THE EIN CONSTRUCTION CATEGORY ARE DUE TO THE 2 TYPI-CAL SITUATIONS ILLUSTRATED ON PAGES 8 AND 9. THE REMAINING CHANGES ARE DUE TO A VARIETY OF REASONS, INCLUDING CLERICAL ERRORS. 'IHE CHANGES DESCRIBED REPRESENT THE DIFFERENCES BETWEEN THE OCTOBER 1986 RESULTS AND THE VALUES WHICH APPEAR IN INTERVENORS Ex, 141, DATED SEPTEMBER 9, 1986. PAGE 1
O UNDERCOUNTING SIMILAR DISCREPANCIES DUE TO ENVELOPING CALCULATIONS S&L DRAWINGS GENERALLY SPECIFY TYPICAL CONNECTION DETAILS FOR VARIOUS CONNECTIONS ON A COMPONENT. BCAP IDENTIFIED SIMILAR DISCREPANCIES ON VARIOUS TYPICAL CONNECTION DETAILS. FREQUENTLY, S&L CALCULATIONS ENVELOPED SUCH DISCREPANCIES TO SAVE ENGINEERING COSTS. INITIAL COUNTS - S&L SOMETIMES COUNTED ONLY THE SPECIFIC DISCRE-PANCIES ADDRESSED IN THE ENVELOPING CALCULATIONS, OCTOBER 1986 COUNT - S&L COUNTED ALL DISCREPANCIES. THIS' SITUATION IS RESPONSIBLE FOR APPROXIMATELY 20% OF THE NET CHANGE FOR WELD DISCREPANCIES IN THE CPH CONSTRUCTION CATEGORY. PAGE 2 J
PORTIONS OF WELD ON STRUT MEMBERS AS BUILT AS SPECIFIED = = rh (_{ [S UNDERLENGTH g OUTSIDE s PERIMETER n j j [ \\0NLY ? !/ 's s g?===y 3 4 h 'I di k b s TYPICALLY THESE ARE SYSTEMS CONTROL WELDS. THE S&L DRAWINGS CALL FOR THE OUTSIDE PERIMETER OF THE STRUT MEMBER TO BE WELDED TO THE ATTACHMENT PLATE. BCAP OBSERVATIONS FREQUENTLY SHOW THAT THE WELD DOES NOT EXTEND COMPLETELY ACROSS THE TOP OF THE LIP OF THE STRUT MEMBER. INITIAL COUNTS - IN MID-1984 AT BYRON, S&L DETERMINED THAT IF THE WELD EXTENDS AT LEAST TO THE CENTERLINE OF THE LIP OF THE STRUT, IT IS ADEQUATE. THIS IS THE CRITERION WHICH WAS USED IN THE S&L AND LKC WALKDOWN OF CABLE PAN HANGERS IN 1985. IN COUNTING BCAP WELD DISCREPANCIES SOMETIMES S&L TREATED UNDERLENGTH WELDS WHICH REACHED THE CENTERLINE AS DISCREPANT CONDITIONS, SOMETIMES NOT. OCTOBER 1986 - S&L ALWAYS TREATED ANY AMOUNT OF UNDERLENGTH IN THE WELD AS A DISCREPANT CONDITION. THIS SITUATION IS RESPONSIBLE FOR APPROXIMATELY 15% OF THE NET CHANGE FOR WELD DISCREPANCIES IN THE CPH CONSTRUCTION CATEGORY. PAGE 3
DV-2 CONNECTION UNDERSIZE WELDS d 5" AS-DESIGNED: I g' 7 1/s" 4 4a fi i I I / TYP. 4 PLACES I V \\EA. CONN. /8 I I 4 PL S EA.CO$N/ I/V 6 AS-BUILT: r y I/g" I I I L d e n I I TYPICALLY THESE ARE SYSTEM CONTROL WELDS. S&L DRAWING 20-E-0-3263, REV. W ACCEPTED A'S-BUILT CONDITION GENERICALLY ON 9/23/83. BCAP DID NOT INVALIDATE THIS CONDITION. INITIAL COUNTS - S&L SOMETIMES TREATED THIS AS DISCREPANT CONDITION - SOMETIMES NOT. OCTOBER 1986 COUNT - ALWAYS TREATED AS DISCREPANT CONDITION THIS SITUATION IS RESPONSIBLE FOR APPROXIMATELY 15% PERCENT OF NET CHANGE FOR WELD DISCREPANCIES IN THE CPH CONSTRUCTION CATEGORY. PAGE 4
DV-1,2,4 85-UNDERLENGTH WELDS AS-DESIGNED : AS-BUILT : Q 8 = (MAIN BUILDING STEEL = 4 m$ 3 6 o UNDERLENGTH DUE -GUSSET PLATE TO EXCESSIVE GAP N: N: 1/8 \\ I% \\ I/! I/8 ! 8 ~%h 'S' STRUT MEMBER TYPICALLY THESE ARE SYSTEMS CONTROL WELDS. THE S&L DRAWINGS SPECIFY A FULL-LENGTH WELD BETWEEN THE GUSSET PLATES AND THE STRUT MEMBER AND SHOW A DIMENSION FOR THE GAP BETWEEN THE STRUT MEMBER AND THE MAIN BUILDING STEEL. THE BCAP OBSERVATIONS SOMETIMES INDICATE THAT THIS WELD IS UNDER-LENGTH. OTHER TIMES THE OBSERVATIONS MERELY INDICATE THAT THE GAP BETWEEN THE STRUT MEMBER AND THE MAIN BUILDING STEEL EXCEEDS THAT CALLED FOR IN THE DRAWINGS (WHICH IMPLIES THE WELDS BETWEEN THE STRUT MEMBER AND THE GUSSET PLATES ARE UNDERLENGTH). INITIAL COUNTS - SOMETIMES S&L IDENTIFIED THESE AS UNDERLENGTH WELDS, SOMETIMES NOT. OCTOBER 1986 COUNT - S&L IDENTIFIED THESE AS UNDERLENGTH WELDS. THIS SITUATION IS RESP 014SIBLE FOR APPROXIMATELY 10% OF THE NET CHANGE IN THE CPH CONSTRUCTION CATEGORY. i PAGE 5
DV-14, DV-19 GUSSET PLATE - COPE GUSSET PLATE HAS BEEN COPED TO CLEAR WELD ON PLATE MAIN BUILDING STEEL r F \\ N' kN i 1 ~ GUSSET PLATE WELDS ARE UNDERLENGTH DUE VERTICAL MEMBER TO THE COPE ON THE GUSSET PLATE AS-DESIGNED: AS - BUILT: 4 S&L DRAWINGS CALLED FOR WELDS RUNNING THE LENGTH OF THE GUSSET PLATE. BCAP OBSERVATIONS' INDICATED THAT THE WELDS WERE "UNDER-LENGTH" DUE TO THE CONSTRUCTION COPE. HOWEVER, A COPE IS REQUIRED TO INSTALL THIS DETAIL. INITIAL COUNTS - S&L DID NOT COUNT THESE WELDS AS UNDERLENGTH BASED ON A JUDGMENT THAT THE DETAIL COULD NOT HAVE BEEN INSTALLED IN ANY OTHER WAY, AND THAT THE WELD WAS NOT DISCREPANT.
- HOWEVER, THIS WAS IMPROPER BECAUSE BCAP HAD NOT INVALIDATED THESE DISCREPAN-CIES.
OCTOBER 1986 COUNT - S&L COUNTED THESE AS WELD DISCREPANCIES. THIS SITUATION IS RESPONSIBLE FOR APPROXIMATELY 5% OF THE NET CHANGE IN THE WELD' DISCREPANCIES IN THE CPH CONSTRUCTION CATEGORY. PAGE 6
AIRLIARY STEEL CO\\N.- OVERSIZE WELDS ~- AS-DESIGNEDi AS-BUILT: rn m a m -c a. c *.. ~ W..oU1 'j?!!E . o. $6 i ? $ b i is 2: i ~ is / l s-TYP. g TYP. \\ N.S. 8 F.S./10 [ f N.S. 8 F.S %[ (WT OF WT. /3 OF WT I ca-O",+ k PER NOTE N.S. i NEAR SIDE F.S.
- FAR SIDE f
WT WIDE FLANGE TEE SECTION j 1 THE S&L DRAWING FOR THIS ITEM CALLS FOR 662 INCH F.!LLET WELDS WITH A MAXIMUM SIZE OF 962 INCH. BCAP OBSERVATIONS SHOW THE SIZE OF THESE WELDS TO BE 1062 INCH. INITIAL COUNTS - S&L DID NOT COUNT THESE WELDS AS DISCREPANT BECAUSE, IN GENERAL ~, OVERSIZED WELDS ARE PERMITTED BY DESIGN DRAWINGS. THIS JUDGMENT WAS INAPPROPRIATE BECAUSE BCAP HAD NOT INVALIDATED THIS OBSERVATION. OCTOBER 1986'C00NT - S8L COUNTED THESE OVERSIZED WELDS AS DISCREP-ANT. / THIS SITUATION IS RESPONSIBLE FOR APPROXIMATELY 5% OF-THE-NET, CHANGE IN THE CPH CONSTRUCTION CATEGORY. f i / PAGE 7 n
O 's USE OF GENERIC MOUNTING DETAIL IN LIEU 0F UNIQUE MOUNTING DETAIL FOR EIN-ll4 S&L DRAWINGS SPECIFY GENERIC AND UNIQUE MOUNTING DETAILS FOR J ELECTRICAL EQUIPMENT. BCAP IDENTIFIED WELD SIZE DISCREPANCIES ON EIN-114, AND FURNISHED A WELD MAP SHOWING WELD SIZES. l INITIAL COUNTS - S&L COUNTED WELD DISCREPANCIES ON EIN-ll4 BASED ON THE GENERIC DETAIL, WHICH SPECIFIED 1/8 INCH FILLET WELDS. OCTOBER 1986 COUNT - S&L COUNTED DISCREPANCIES ON EIN-ll4 BASED ON THE UN!QUE DETAIL, WHICH SPECIFIED 1/2 INCH FILLET WELDS. THIS RESULTED IN COUNTING ADDITIONAL WELD DISCREPANCIES. THIS SITUATION IS RESPONSIBLE FOR APPROXIMATELY.10% OF THE NET CHANGE FOR WELD DISCREPANCIES IN THE EIN CONSTRUCTION CATEGORY. 1 PAGE 8
EQUIPMENT. HOLD-DOWN O SHIM WELDS SHIM 4 WELD) PLAN 2-WELDS l-WELD V /V V 2-WELDS /,, ' ,~ ~ ~ '[ d ' ~h. f ,'d.'{ o.- a p.. c_a o a SECTION: AS DESIGNED-SECTION: AS BUILT SECTION: AS ANALYZED S&L DRAWINGS CALL FOR THE USE OF SHIM PLATES, AS REQUIRED, UNDER PIECES OF EQUIPMENT. THE WELD BETWEEN THE EQUIPMENT AND THE SHIM AND THE WELD BETWEEN THE SHIM AND THE EMBEDMENT PLATE ARE SPECIFIED AS SEPARATE WELDS. FREQUENTLY, BCAP OBSERVATIONS IDENTIFY ONLY ONE LARGE WELD ENTIRELY COVERING THE SHIM PLATE WITH A TYPICAL NOTATION " SHIM PLATE LOCA- ) TION INDETERMINATE." IN ANALYZING FOR DESIGN SIGNIFICANCE, S&L MADE THE WORST CASE ASSUMPTION THAT THE SHIM EXTENDS TO THE FACE OF THE WELD. INITIAL COUNTS - S&L TYPICALLY COUNTED THESE SHIM WELDS AS ONE WELD. OCTOBER 1986 COUNT - S&L COUNTED THESE AS TWO SEPARATE WELDS, WHICH GENERALLY RESULTS IN MULTIPLYING THE NUMBER OF IDENTIFIED WELD DISCREPANCIES BY TWO. THIS SITUATION IS RESPONSIBLE FOR APPROXIMATELY 55% OF THE NET CHANGE IN THE EIN CONSTRUCTION CATEGORY. AGE 9
f O C (DelGeorge-1) i Revision 2 - 10/30/86 .i CSR REINSPECTION RESULTS FOR LKC All Populations, All Samples, Welding and Non-Welding 40000 40000 Number of Inspection Points 30000- -30000 l ~ 20000- -20000 l lEE ) g g -10000 10000 S e-A lie 0 0 .... -100 3 l 100-l 90- -90 E i 80- -80 I 70- -70 )
- s0-
-s0 j Es0- -s0 g l E 40- -40 y 30- -30 g i 20- -20 :: h l 10- -10 8 l Ou,.t.ci i,, i 2 i.iiiai2 ,.;i,,i2 ,4 ii,,i2 ,.,i,,i2 i. 1 i,i ^ 1979 1980 1981 1982 1983 1984 M/ff.
. C (DelGeorge-2) Revision 2 - 10/30/86 CSR REINSPECTION RESULTS FOR LKC All Populations, All Samples, Welding Only 40000 40000 Number of Inspection Points 30000- -30000 20000 20000 I 10000- -10000 0 0 l -100 3 100- .T go- -go E 80- -s0 t j 70- -70 ) j
- s0-
-s0 Es0- -s0 ; j e 40- -40 30- -30 g
- g l
20-s0- -10 1 0 0 4 j GU8Pterl iI 2 I 3 I 4 I iI 2 I 3 1 4 I iI 2 I 3 I 4 I iI 2 I 3 I 4 I I I 2 1 3 I 4 I i I 2 I i 1979 1980 1981 1982 1983 1984
(
- C (DelGeorge-3)
Revision 2 - 10/30/86 i CSR REINSPECTION RESULTS FOR LKC All Populations,- All Samples, Welding Only Number of Welds ~ 1500-1500 1000- -1000 2 's00 s00 d d EEEE Pi E Ill m_ 0 100- -100 -90 90-l 80- -80 f, l 70- -70 E y 60- -60 T i y50- -50 ) E 40- -40 j 30- -30 3 20- -20 E l 10- -10 0 0 QugpterI iI 2 I 3 I 4 I iI 2 1 3 I 4 I i I 2 I 3 I 4 I iI 2 I 3 I 4 I iI 2 I 3 I 4 I 1 I 2 1 1979 1980 1981 1982 1983 1984 Wsok-
/
- C (DelGeorge-4)
Revision 2 - 10/30/86 CSR REINSPECTION RESULTS FOR LKC 24 LKC Inspectors, All Samples, Welding Only 2000o 20000 Number of Inspection Points { 15000- -1s000 10000- -10000 5000- -5000 g' b b b g 100- ~-100 90-Inspection Point -90 Agreement Rate -80 so. 70- -70 y 60- -60 [so- -se g 40- -40 30- -30 20- -20 -10 10-I 0 0 QugptepI iI 2 I 3 I 4 I iI 2 I 3 I 4 I iI 2 I 3 I 4 I i I 2 I 3 I 4 I i I 2 I 3 1 4 1 1 I 2 I 1979 1980 1981 198a 1983 1984 Woln
' Attachment 2C (DelGeorge - 5) Revision 2 - 10/30/86 CSR REINSPECTION RESULTS FOR LKC 24 LKC Inspectors, All Samples, Welding Only 2000 2000 Number of Welds 1500f ,-1500 l t 1000- -1000 i ) 500- -500 M VA M WA 5 i 0 0 100- -100 90-Weld Agreement Rate -90 80- ~80 ] 70- -70 y 60- -80 i 50- -50 j' 40- -e l 30- -30 'l l' 20- -20 l 10- -10 2. 0 0 Guartert i1 2 1 3 i 4 iii2 1 3 1 4 i iiai3 1 4 1 1 1 2 1 3 1 4 I 1 1 2 1 3 I 4 I i I ai 1979 1980 1981 1982 1983 1984 I W&
- C (DelGeorge -6) j Revision 2 - 10/30/86 \\ CSR REINSPECTION RESULTS FOR LKC 24 LKC Inspectors, All Samples i acooo aoooo j Number of Inspection l Points Welding 1 15000- -15o0c 10000- -10000 J 5000 -5000 o YA $ V o 2o000- -20o0c Number of Inspection l Points Non-Welding 15000- -15o0c j e l 10000-a Insp. -10000 i iii nnnni 5000 22 Insp. .soon l l lim SEI O sma l QuartepI i I 2 I 3 I 4 1 1 I 2 I 3 I 4 I i1 2 I 3 I 4 I iI 2 I 3 1 4 I iI 2 I 3 1 4 ! i I 2 I i 1979 1980 1981 1982 1983 1984 I w
ATTACHMENT 2C (KAUSHAL-3) Revision 2 CSR Reinspection Results For Electrical Construction Categories ~ Total Notable Design Construction Population Total Inspection insignificant Discrepancies Sigrtificant Category Size Reinspected Points Discrepancies (%) Discrepancies Conduits 2,828 122 5,800 136 10 (0.17) O Corduit Hangers 10,676 133 32,700 189 103 (0.31) O Cables 2,722 120 20,100 305 0 (0.00) O Cable Pans 893 90 30,400 264 24 (0.08) O' Cable Pan Hanger 3,769 130 129,000 1,308 532 (0.41) O Electrical Equipnent Installation 1,843 138 58,000 591 540 (0.93) 0 'IMAL 22,731 733 276,000 2,793 1,209 (0.44) 0 =
Attachnent 2C (Kaushal-4) i Revision 2 30-Oct-86 CSR DATABASE VERSION 10/30/06 PAGE 1 <m k ITEM R INSP DATE ATT IP DP WI WD () 1 CBL-002 R FJR 16-Jun-82 P 302 0 0 0 2 CBL-OO2 R .NK 16-Sep-83 T 40 0 0 0 3 CBL-002 R' NK 12-Jul-82 T 40 1 0 0 (). 4 CBL-OO3~ R MSS 22-Feb-84 T 26 0 0 0 5 CBL-003 R TS 03-Feb-84 P 84 0 0 0 6 CBL-OO3 R MSS 16-Feb-84 T 26 0 0 0 () 7 CBL-004 R GF 15-Aug-83 P 93 1 0 0 8 CBL-OO4 R DS 12-Sep-83 T 45 0 0 0 9 CBL-004 R DS 18-Aug-83 T 45 0 0 0 [] 10 CBL-OO5 R FJR 10-Mar-82 P 232 O O O 11 CBL-005 -R NK 21-Feb-84 T 30 0 0 0 12 CBL-OO5 R NK 24-Feb-84 T 30 0 0 0 () -13 CBL-006 R TS 19-Mar-84 P 111 0 0 0 14 CBL-OO6 R MSS 07-Jun-84 T 100 0 0 0 15 CBL-006 R NK 06-Apr-84 T 100 2 0 0 () 16 CBL-OO7 R GF 25-May-83 P 36 O O O 17 CBL-007 R JMH 07-Jun-83 T 11 0 0 0 18 CBL-OO7 R DS 29-Jul-83 T 11 O O O g 19 CBL-008 R NK 17-Feb-84 T 35 0 0 0 20 CBL-OO8 R NK 08-Mar-84 T 35 0 0 0 21 CBL-008 R MDL 06-Jan-86 P 120-1 0 0 g 22 CBL-OO9 R DS 14-Jul-82 T 16 O O O 23 CBL-009 R FJR 14-Jul-82 P 62 2 0 0 24 CbL-OO9 R DS 21-Jul-82 Y 16 O O O 8 25 CDL-010 R DS 15-Oct-83 T 25 0 0 0 26 CBL-010 R JLL 09-May-83 P 267 2 O O 27 CBL-010 R DS 24-Feb-83 T 25 0 0 0 g 20 CBL-011 R KMC 11-Apr-84 T 40 0 0 0 29 CBL-011 R TS 06-Feb-84 P 98 3 0 0 30 CBL-011 R NK 05-Mar-84 T 40 0 0 0 g 31 CBL-012 R NK 30-Jun-83 T 10 0 0 0 32 CBL-012 R FJR 24-Feb-83 P 89 0 0 0 33 CBL-012 R DS 13-Jul-83 T 10 0 0 0 g 34 CBL-013 R NK 15-Dec-82 T 10 0 0 0 35 CBL-013 R FJR 27-Oct-82 P 115 3 0 0 36 CBL-013 R NK 05-May-83 T 10 0 0 0 g 37 CBL-014 R FJR 04-Mar-83 P 60 0 0 0 38 CBL-014 R KMC 08-May-84 T 10 0 0 0 39 CBL-014 R KMC 08-May-84 T 10 0 0 0 ( 40 CBL-015 R DS 08-Mar-82 T 20 0 0 0 41 CBL-015 R FJR 24-Feb-82 P 134 1 0 0 42 CBL-015 R NK 08-May-84 T 20 0 0 O ( 43 CBL-016 R DS 08-Mar-82 T 55 0 0 0 44 CBL-016 R JMH 15-Feb-82 P 206 O O O 45 CBL-016 R NK 26-Apr-83 T 55 0 0 0 ( 46 CBL-017 R NK 11-Oct-83 T 30 6 0 0 47 CBL-017 R NK 03-Apr-84 T 30 0 0 0 48 CBL-017 R JMH 30-Mar-83 P 62 4 O O ( 49 CBL-018 R DS 07-Apr-83 T 60 0 0 0 50 CBL-018 R NK 01-Dec-83 T 60 3 0 0 51 CBL-018 R FJR 11-Mar-83 P 83 0 0 0 ( 52 CBL-019 R DS 26-Feb-82 T 40 0 0 0 53 CBL-019 R FJR 12-Feb-82 P 193 0 0 0 54 CBL-019 R DS 19-Mar-82 T 40 0 0 0 ( 55 CbL-020 R DS 11-Apr-83 T 35 0 0 0
30-Oct-C6 CSR DATABASE VERSION 10/30/86 PAGE 2 ITEM R INSP DATE ATT IP DP WI WD 56 CBL-020 R KMC 09-Apr-84 T 35 O O O 57 CBL-020 R NK 02-Mar-83 P 77 0 0 0 58.CBL-021 R JMH 11-Apr-83 P 184 41 O O 59'CBL-021 R MDL 21-Jul-83 T 40 0 0 0 60 CBL-021 R MDL 30-Jun-83 T 40 0 0 0 61 CBL-022 R NK 28-Jan-82 P 85 1 0 0 t 62 CBL-022 R DS 06-Jan-82 T 20 5 O O-63 CBL-022 R DS 16-Jun-82 T 20 0 0 0 64 CBL-023 R DS 27-Jun-83 T 13 O' O O 65 CBL-023 R JMH 21-Apr-83 P 82 0 0 0 66 CBL-023 R DS 15-Jul-83 T 13 0 0 0 67 CBL-024 R FJR 11-Jul-82 P 51 2 0 0 68 CBL-024 R NK 20-Sep-83 T 25 0 0 0 69 CBL-024 R NK 30-Jul-82 T 25 0 0 0 70 CBL-025 R NK 15-Jul-83 T 10 0 0 0 i 71 CBL-025 R NK 15-Apr-83 T 10 0 0 0 72'CBL-025 R MDL 07-Apr-83 P 123 0 0 0 73 CBL-026 R FJR 12-Jul-82 P 264 0 0 0 74 CBL-026 R KMC 10-May-84 T 45 0 0 0 75 CBL-026 R DS 05-Aug-82 T 45 0 0-O 76 CBL-027 R JMH 13-Nov-81 P 121 O O O 77 CBL-027 R DS 02-Dec-81 T 10 0 0 0 78 CBL-027 R DS 13-Jan-82 T 10 0 0 0 79 CBL-028 R DS 04-Mar-82 T 35 0 0 0 80 CBL-028 R MSS 17-Feb-82 P 330 0 0 0 81 CBL-028 R DS 19-Mar-82 T 35 0 0 0 82 CBL-029 R MDL 03-Nov-83 T 10 0 0 0 83 CDL-029 R KMC 10-May-84 T 10 0 0 0 84 CBL-029 R JMH 17-Mar-83 P 93 1 O O 65 CBL-030 R MDL 19-Oct-83 T 20 0 0 0 86 CBL-030 R JMH 14-Jul-82 P 231 2 O O 87 CBL-030 R DS 27-Aug-82 T 20 0 0 0 88 CBL-031 R NK 19-Apr-84 T 23 O O O 89 CBL-031 R JNH 30-Dec-82 P 54 2 0 0 90 CBL-031 R NK 05-Mar-83 T 23 0 0 0 91 CBL-032 R MDL 20-Feb-84 P 25 0 0 0 92 CBL-032 R-MSS 24-Feb-84 T 10 0 0 0 93 CBL-032 R MSS 19-Apr-84 T 10 0 0 0 94 CBL-033 R DS O2-Dec-83 T 25 0 0 0 95 CBL-033 R MDL 07-Nov-83 P 204 0 0 0 96 CBL-033 R DS 12-Apr-83 T 25 0 0 0 97 CBL-034 R NK 14-Feb-83 T 1 0 0 0 98 CBL-034 R-FJR 22-Jan-82 P 175 4 0 0 99 CBL-034 R DS-14-Nov-83 T 1 0 0 0 100 CBL-035 R DS 11-Aug-83 T 10 0 0 0 101 CBL-035 R NK 01-Feb-84 T 10 0 0 0 102 CBL-035 R FJR 04-Aug-83 P 27 0 0 0 l 103 CBL-036 R NK 16-Dec-82 T 35 0 0 0 104 CBL-036 R JLL 21-Sep-82 P 130 0 0 0 105 CBL-036 R NK 27-Sep-83 T 35 0 0 0 1 106 CBL-037 R NK 14-Jul-83 T 20 0 0 0 1 l 107 CBL-037 R DS 14-Jul-83 T 20 0 0 0 108 CBL-037 R FJR 21-Jun-83 P 141 1 O O 109 CBL-038 R DS 22-Jun-83 T 132 0 0 0 l 110 CBL-038 R JMH 18-May-83 P 60 0 0 0 l l l l
30-Oct-86 CSR DATABASE VERSION 10/30/86 PAGE 3 5' ITEM R INSP DATE ATT IP DP WI WD '( 111 CBL-038 R MSS 25-Jan-84 T 132 0 0 0 112 CBL-039 R TS 06-Jan-84 P 45 O O O 113 CBL-039 R NK 12-Jan-84 T 13 3 0 0 ( 114 CBL-039 R DS 12-Jan-84 T 13 3 0 0 115 CBL-040 R KLB 12-Nov-83 P 38 1 0 0 116 CBL-040 R DC 22-Dec-83 T 6 O O O ( 117 CBL-040 R DS 02-Feb-84 T 6 1 0 0 118 CBL-041 R NK 18-Jul-83 T 15 O O O 119 CBL-041 R MDL 31-May-83 P 49 0 0 0 ( 120 CBL-041 R JMH 07-Jun-83 T 15 0 0 0 121 CBL-042 R JTR 11-Feb-83 P 149 0 0 0 122 CBL-042 R KMC 21-Mar-84 T 10 0 0 0 { 123 CBL-042 R DS 24-Feb-84 T 10 0 0 0 124 CBL-043 R KMC 08-May-84 T 35 O O O 125 CBL-043 R JMH 20-Apr-83 P 96 0 0 0 { 126 CBL-043 R JMH 13-Dec-82 T 35 O O O 127 CBL-044 R NK 23-Mar-83 T 15 0 0 0 128 CBL-044 R NK 11-Apr-83 T 15 O O O { 129 CBL-044 R MGS 02-Mar-83 P 35 0 0 0 130 CBL-045 R GF 18-Dec-83 P 144 0 0 0 131 CBL-045 A NK 19-Jan-84 T 25 0 0 0 _[ 132 CBL-045 R NK 27-Dec-83 T 25 O O O 133 CBL-046 R DS L1-Apr-83 T 30 6 0 0 134 CBL-046 R MSS O2-Mar-83 P 48 O O O [ 135 CBL-046 R NK 26-Mar-83 T 30 0 0 0 136 CBL-047 R DS 05-Feb-82 T 10 0 0 O L37 CBL-047 R NK JG-Feb-82 T 10 0 0 0 ( 138 CBL-047 R FJR 26-Jan-82 P 96 0 'O O 139 CBL-048 H NK 09-Jan-84 P 49 0 0 0 140 CBL-048 R NK 18-Jan-84 T 20 0 0 0 [ 141 CDL-048 R NK 19-Jan-84 T 20 0 0 0 142 CBL-049 R FJR 03-May-84 P 47 O O O 143 CBL-049 R NK dd-May-84 T 22 0 0 0 .[ 144 CBL-049 R NK 22-May-84 T 22 i O O 145 CBL-050 R NK 19-Aug-82 .T 11 0 0 0 146 CBL-050 R DS 23-Nov-83 T 11 3 0 0 ( 147 CBL-050 R JLL 05-May-83 P 51 4 0 0 148 CBL-051 R JTR 12-Aug-82 P 117 3 O O 149 CBL-051 R DS 27-Aug-82 T 10 0 0 0 [ 150 CBL-051 R DS 28-Dec-82 T 10 0 0 0 151 CBL-052 R NK 22-Feb-82 T 20 0 0 0 152 CBL-OG2 R JMH 12-Feb-82 P 247 0 0 0 [ 153 CBL-052 R ERB 02-Mar-82 T 20 0 0 0 154 CBL-053 R GF 27-Jan-84 P 108 1 O O 155 CBL-053 R NK 02-Feb-84 T 10 0 0 0 [ 156 CBL-053 R NK 17-Feb-84 T 10 0 0 0 157 CBL-054 R KMC 08-May-84 T 50 0 0 0 158 CBL-054 R MDL 02-May-83 P 154 O O O l 159 CBL-054 R DS 21-Mar-83 T 50 0 0 0 160 CBL-055 R NK 10-Aug-82 T 10 1 O O 161 CBL-055 R NK 02-Aug-82 T 10 0 0 0 l 162 CBL-055 R JTR 13-Jul-82 P 106 0 0 0 163 CBL-056 R MDL 29-Jun-83 T 30 0 0 0 164 CBL-056 R JMH 12-Apr-83 P 158 14 0 0 { 165.CBL-056 R NK 07-May-83 T 30 0 0 0
F } 30-Det-86 CSR DATABASE VERSION 10/00/86 PAGE ITEM R INSP DATE ATT IP DP WI WD 166 CBL-057 R FJR 16-Jul-82 P 139 0 0 0 167 CBL-057 R NK 17-Sep-82 T 20 0 0 0 168 CBL-057 R NK 18-Aug-82 T 20 0 0 0 l .j 169 CBL-058 R NK 03-Nov-82 T 15 0 0 0 l 170 CBL-058 R JMH 08-Oct-82 P 233 14 0 0 171 CBL-058 R DS 22-Oct-82 T 15~ O O O ~ 172 CBL-059 R RMS 15-Mar-83 P 233 2 O O 173 CBL-059 R FJR 21-Apr-83 T 25 O O O 174 CDL-059 R KMC 08-May-84 T 25 O O O 175 CBL-060 R NK 05-Jul-83 T 56 0 0 0 176 CBL-060 R DS 30-Apr-84 T 56 0 0 0 177 CBL-060' R JMH 21-Jun-82 P 134 1 O O 178 CBL-061 R NK 03-Dec-82 T 50 0 0 0 179 CBL-061 R JLL 27-Oct-82 P 197 O O O 180 CBL-061 R DS 03-Jan-83 T 50 0 0 0 t f 181 CDL-101 E MSS 26-Jan-84 T 6 O O O 182 CBL-101 E MSS 24-Oct-81 T 6 0 0 0 183 CDL-101 E NSS 24-Apr-81 P 36 0 0 'O 184 CBL-102 E JTR 10-Sep-82 P 112 i O O 185 CBL-102 E DS 11-Jan-83 T 18 i O O 186 CBL-102 E NK 09-Nov-83 T 18 i O O i 187 CDL-103 E NK 08-Sep-8? T 13 0 0 0 188 CBL-103 E JMH 13-Aug-8c P 68 1 O O 189 CDL-103 E NK 08-Gep-82 T 13 1 O O _f 190 CBL-104 E FJR 08-Mar-83 P 83 0 0 0 191 CDL-104 E NK 11-Mar-83 T 18 O O O 192 CBL-104 E NK 28-Feb-83 T 18 1 O O ( 193 CDL-105 E KMC 08-May-84 .T 40 0 0 0 194 CbL-105 E NK G3-Dec-83 T 40 0 0 0 195 CDL-105 E JLL 22-Nov-82 P 105 7 0 0 ( 196 CBL-106 E NK 25-Jan-83 T 18 1 O O 197 CDL-106 E DS 14-Sep-83 T 18 O O O 198 CDL-106 E JTR 24-Nov-82 P 98 1 O O ( 199 CDL-107 E JMH 23-Jun-G2 P 85 0 0 0 200 CBL-107-E NK 28-Jun-82 T 18 3 0 0 201 CDL-107 E NK 06-Jul-82 T 18 O O O ( 202 CBL-108 E NK OG-Apr-83 T 13 0 0 0 203 CBL-108 E MSS 25-Apr-84 T 13 0 0 0 204 CBL-108 E MSS 30-Mar-83 P 91 O O O ( 205 CDL-109 E NK 07-Dec-81 T 16 O O O 206 CBL-109 E JMH 03-Dec-81 P 120 0 0 0 207 CBL-109 E NK 08-Dec-81 T 16 0 0 O ( 208 CBL-110 E DS 21-Feb-83 T 17 2 O O 209 CBL-110 E MSS 17-Feb-83 P 85 3 O O 210 CBL-110 E DS 17-Feb-84 T 17 O O O ( 211 CBL-111 E DS 31-Dec-82 T 18 0 0 0 212 CBL-111 E DS 28-Dec-82 T 18 3 0 0 213 CDL-111 E FJR 05-Aug-82 P 114 O O O ( 214 CBL-112 E FJR 12-May-83 P 125 1 O O 215 CDL-112 E NK 17-Jun-83 T 16 1 O O 216 CBL-112 E DS 22-Dec-82 T 16 0 0 0 { 217 CDL-113 E JPH 15-Mar-83 P 144 3 O O 218 CBL-113 E MSS 25-Apr-84 T 25 0 0 0 219 CDL-113 E NK 20-Jun-84 T 25 i O O l 220 CBL-114 E DS 27-Sep-83 T 13 0 0 0
30-Oct CSR DATABASE' VERSION 10/30/86 PAGE.E ITEM R INSP DATE ATT IP DP WI WD 221 CBL-114 E DS- 07-Apr-83 T 13 0 0 0 222 CBL-114 E MSS 09-Mar-83 P 121 1 O O 223 CBL-115 E DS 05-Nov-83 T 25 1 0 0 224 CBL-115 E JMH 03-Nov-82 P 110 1 0-0 225 CBL-115 E NK 01-Nov-82 T 25 0 0 0 226 CBL-116 E MSS 12-Jan-83 P 81 1 O O 227 CBL-116 E DS 15-Jun-83 T 13 0 0 0 228 CBL-116 E DS 21-Jan-83 T 13 2 O O 229 CDL-117 E MSS. 12-Jan-83 P 84 0 0 0 230 CBL-117 E NK 14-Feb-83 T 35 0 0 0 231 CBL-117 E DS.21-Jan-83 T 35 2 O O 232 CBL-lia E KMC 10-May-84 T 10 0 0 0 233 CBL-118 E IM3 07-Jul-83 T 10 2 O O 234 CBL-118 E MDL 02-May-83 P 88 O O O 235 CBL-119 E.MDL 12-May-83 P 78 O O O 236 CBL-119 E DS 17-May-83 T 60 16 0 O 237 CBL-119 E NK 05-Aug-83 T-60 0 0 0 238 CBL-120 E DS 09-Mar-83 T 13 0 0 0 239 CDL-120 E JTR 03-Mar-83 P 70 0 0 O 240.CBL-120 E NK 26-Sep-83 T 13 O O O 241 CEL-121 E NK 01-Dec-81 T 18 0 0 0 242 CBL-121 E JMH 12-Jan-82 P 117 0 0 0 243 CBL-121 E NK 04-Dec-81 T 18 0 0. O 244 CBL-122 E NK 08-Mar-84 T 17 1 'O O 245 CBL-122 E NK 17-Aug-82 T 17 O O O 246 CBL-122 E MDL 07-Mar-84 P 108 1 0 0 l 247 CDL-123 -E NK 29-Nov-83 T 13 0 0 0 248 CDL-123 E MSS 15-Mar-83 P 72 O O O 249 CDL-123 E DS 30-Jun-83 T 13 0 0 0 250 CDL-104 E NK 13-Jul-82 T-45 0 0 0 251 CDL-124 E JMH 30-Jun-82 P 146 0 0-0 252 CDL-124 E NK 08-Jul-82 T 45 0 0 0~ l 253 CBL-125 E NK 22-Feb-82 T 45 0 0 0 254 CDL-125 E JLL 02-Feb-82 P 137 1 O O 253 CDL-125 E NK Feb-82 T 45 0 0 0 256 CBL-126 E NK 14-Apr-83 T 60 0 0 0 257 CDL-126 E DS 21-Nov-83 T 60 0 0 0 l 258 CBL-126 E KLB 11-Apr P 85 2 O O 259 CBL-127 E NK 08-Dec-83 T 40 0 0 0 260 CBL-127 E MSS 16-Feb-82 P 299 4 0 0 261 CEL-127 E NK 18-Mar-82 T 40 0 0 0 262 CBL-128 E DS 16-Jun-84 T 13 0 0 0 263 CDL-128 E JMH 17-Jan-83 P 69 .0 0 0 264 CBL-128 E KMC 08-May-84 T 13 O O O 265 CBL-129 E ' INK 10-Oct-83 T 18 1 O O 266 CBL-129 E JMH 21-Jan-83 P 47 4 -O O 267 CBL-129 E NK 27-Jan-83 T '18 0 0-0 268 CBL-130 E NK 10-Oct-83 T 18 3 0 0 269 CBL-130 E NK 27-Jan-83 T 18 0 0 0 1 270 CBL-130 E JTR 21-Jan-83 P 45 4 0 0 271 CDL-131 R NK 01-Feb-83 T 41 0 'O O 272 CBL-131 R JLL 26-Jan-83 P 195 0 0 0 l 273 CBL-131 R DS 31-May-83 T 41 0 0 0 274 CDL-132 R KMC 08-May-84 T 10 2 O O 275 CDL-132 R FJR 07-Oct-82 P 96 1 0 0
e 30-Oct-86 CSR DATABASE VERSION 10/30/86 PAGE'6 O ITEM R INSP. .DATE ATT IP DP WI WD + {} 276 CBL-132 R DS 14-Sep-83 T 10 0 0 0 277 CBL-133 R NK Jan-84 T 10 0-0 0 278 CBL-133 R GF 20-Jan-84 P 44 O O O (} 279 CBL-133 R DS 23-Feb-84 T 10 3 0 0 280 CBL-134 R JMH 03-Dec-82 T 35 0 0 0 281 CBL-134 R NK 12-Nov-83 T 35 7 O' O ()' 282 CBL-134 R FJR 22-Nov-82 P 65 2 O O 283 CBL-135 R MSS 07-Apr-83 P 387 0 0 0 284 CBL-135 R NK 11-May-83 T 45 O O O .() 285 CBL-135 R DS 14-Jun-83 T 45 0 0 0 286 CBL-136 R DS 19-Sep-83 T 10 0 0 0 287 CBL-136 R DS 30-Aug-83 T 10 0 0 0 () 288 CBL-136 R THS 13-Jul-83 P 209 O O O 889 CBL-137 R MSS 13-Jan-83 P 158 0 0 'O 290 CBL-137 R NK 14-Jun-83 T 10 1 O O (') 291 CBL-137 R NK 09-Dec-83 T 10 0 0 0 292 CBL-138 R DS 15-Feb-82 T 20 1 O O 293 CBL-138 R JLL 03-Feb-82 P 107 1 0 0 () 294 CBL-138 R DS 09-May-83 T 20 0 0 0 295 CBL-139 R .DS 25-Jun-82 T 25 0 0 0 296 CDL-139 R NK O2-Jul-82 T 25 0 0 0 (} 297 CBL-139 R NK 16-Jun-82 P 215 4 0 0 298 CBL-140 R DS 14-Mar-83 T 66 0 0 0 299 CBL-140 R JTR 04-Mar-83 P 130 1 0 0 (] 300 CBL-140 R.KMC 08-May-84 T 66 0 0 0 301 CBL-141 R DS 04-Jan-84 T 10 0 0 0 302 CDL-141 R NK 10-Feb-84 T 10 0 0 0 g 303 CBL-141 R GF 16-Dec-83 P 116 0 0 0-304 CBL-142 -R DS 29-Nov-83 T 5 0 0 0 305 CBL-142 R DS 20-Doc T 5 0 0 0 g 306 CBL-142 R KLB 12-Nov-83 P 31 O O O 307 CBL-143 R NK 18-Apr-84 T 10 0 0 0 308 CBL-143 R GF 20-Jan-84 P 61 1 O O g 309 CBL-143 R MSS 08-Feb-84 T 10 0 0 0 310 CBL-144 R GF 30-Jan-84 P 139 0 0 0 311 CBL-144 R MSS 08-Feb-84 T 30 0 0 0 g 312 CBL-144 R MSS 09-Feb-84 T 30 0 0 0 313 CBL-145 R FJR 22-Apr-83 P 108 7 0 0 314 CBL-145 R NK-25-Apr-83 T 25 0 0 0 g 315 CBL-145 R NK 21-Apr-83 T 25 0 0 0 316 CBL-146 R NK 31-Aug-82 T 20 4 O O 317 CBL-146 R JTR 27-Aug-82 P 232 2 0 0 g 318 CBL-146 R NK O2-Sep-82 T 20 0 0 0 319 CBL-147 R MSS 28-Mar-84 T 22 0 0 0 320 CBL-147 R DS 25-Apr-83 T 22 O O O ( 321 CBL-147 R MSS 28-Mar-84 P 40 2 0 0 322 CBL-148 R MDL 13-Dec-83 P 51 O O O 323 CBL-148 R NK' 19-Dec-83 T 15 0 0 0 g 324 CBL-148 R NK 19-Dec-83 T 15 0 0 0 325 CBL-149 R NK 05-Nov-82 T 15 0 0 0 326 CBL-149 R NK 27-Oct-82 T 15 O O O ( 327 CBL-149 R JMH 08-Oct-82 P 179 16 0 0 328 CBL-150 R NK 01-Dec-82 T 40 0 0 0 329 CBL-150 R JMH 29-Oct-82 P 110 0 0 0 f 330 CbL-150 R NK 17-Sep-82 T 40 0 0 0
~20-Oct-86 CSR DATABASE VERSION 10/30/86 PAGE 7 't ITEM R INSP DATE ATT IP DP WI WD g 331 CBL-151 R DS 26-Mar-83 T 20 0 0 0 332 CBL-151 R MSS O2-Mar-83 P 46 0 0 0 333 CBL-151 R DS 06-Apr-83 T 20 0 0 0 ( 334 CBL-153 R NK 22-Jun-82 T 10 0 0 0 335 CBL-153 R. JMH 09-Jun-82 P 150 18 O O 336 CBL-153 R DS 17-Jun-82 T 10 0 0 0 ( 337 CBL-154 R DS 23-Mar-83 T 11 0 0 0 338-CBL-154 R DS 24-Mar-83 T 11 O O O 339 CBL-154 R MS3 11-Mar-83 P 59 1 0 0 ( 340 CBL-155 R MDL 14-Jun-83 P 126 2 O O 341 CDL-155 R NK 30-Jul-82 T 10 0 O-0 342 CBL-155 R NK O2-Aug-82 T 10 0 0 0 g 343 CBL-156 .R DS 23-Apr-83 T 10 0 0 0 344 CBL-156 R FJR 17-Jun-82 P 27 0 0 0 345 CBL-156 R NK 28-Jun-82 T-10 0 0 0 ( 346 CBL-157 R NK 26-Aug-82 T 60 1 O O 347 CBL-157 R DS 31-Aug-83 T 60 0 0 0 348 CBL-157 R MSS 04-Apr-83 P 73 0 0 0 g 349 CBL-158 R JTR 09-Aug-82 P 56 0 0 0 350 CDL-158 R DS 18-Aug-82 T 13 1 O O 351 CBL-158 R NK 26-Aug-82 T 13 0 0 0 g 352 CBL-159 R JLL 22-Sep-82 P 224 1 O O 353 CBL-159 R NK 30-Sep-82 T 35 O O O 354 CBL-159 R NK 01-Oct-82 T 35 0 0 0 ( 335 CBL-160 R DS 27-Dec-83 T 18 1 0 0 356 CBL-160 R DS 12-Sep-83 T 18 O O O 357 CBL-160 R FJR 08-Mar-83 P 79 0 0 0 .( 358.CBL-161 R TS 10-Aug-83 P 61 O O O 359 CBL-161 R OS 15-Aug-83 T 11 0 0 0 360 CBL-161 R NK 23-Aug-83 T 11 O O O ( 361 CDP-001 R DJS 02-May-83 C 386 3 0 0 451 CDP-OO1 R DRH 19-Aug-83 W 93 0 6 0 362 CDP-002 R KLB 21-Jan-83 C 24 0 0 0 ( 452 CBP-OO2 R LKB 04-Apr-84 W 33 0 2 0 363 CDP-003 R DJS 02-Sep-83 C SG5 5 0 0 453 CDP-OO3 R RLM 11-Sep-81 W 213 0 14 0 ( 364 CDP-004 R DJF 18-Aug-83 C 221 4 0 0 454 CBP-OO4 R DJS 10-Oct-83 W 93 0 6 0 455 CDP-004 R DB 28-Nov-83 W 93 0 6 0 ( 365 CBP-OO5 R DJF 18-Jan-84 C 255 4 0 0 456 CDP-005 R CNT 09-Dec-83 W 63 0 4 0 456.1 CDP-OO5 R HWS 13-Aug-84 W 63 0 4 0 ( 366 CDP-006 R KLB 26-Jun-82 C 177 21 0 0 457 CBP-OO6 R KK2 19-Jul-82 W 33 0 2 0 367 CDP-007 R DJF 18-Jan-84 C 114 4 0 0 ( 368 CBP-COB R DJF 31-Jan-84 C 402 9 0 0 458 CBP-008 R SL 24-Apr-81 W 183 0 la 0 369 CBP-OO9 R DJS 07-Jul-83 C 98 3 0 0 ( 459 CBP-009 R SL 02-Jun-81 W 93 0 6 0 370 CBP-010 R DJS 11-Jul-83 C 322 3 0 0 460 CDP-010 R SL 02-Jun-81 W 123 0 8 0 g 461 CDP-010 R IFD 02-Jul-81 W 153 0 10 .O 371 CDP-011 R DJS 07-Jul-83 C 21 0 0 0 462 CDP-011 R SL 02-Jun-81 W 33 0 2 O ( 372 CDP-012 R DJS 06-Nov-81 C 283 5 0 0
30-Oct-86 CSR DATABASE VERSION 10/30/86 PAGE 8 6 ITEM R INSP DATE ATT IP DP WI WD .( 373 CDP-013 R KLB 21-Jan-83 C 2S6 1 O O 463 CBP-013 R TML 02-Nov-83 W 33 0 2 O~ 4G3.1 CBP-013 R LKB 11-Apr-84 W 33 0 2 O ( 374 CBP-014 R DJS 09-Nov-81 C -25G O O O 464 CDP-014 R IFD 04-Jun-81 W 63 1 4 1 375 CBP-015 R KLB 07-Jul-82 C 168 0 0 0 _(. 465 CBP-015 -R DLP 31-Mar-84 W 93 0 6 0 376 CBP-016 R KLB 26-Jun-82 C 167 0 0 0 466 CBP-016 R RLM 14-Sep-83 W 33 0 2 O ( 466.1 CBP-016 R MSS 30-Jun-81 C 167 0 0 0 377 CBP-017 R TS- 07-May-84 C 108 O O O 467 CDP-017 R CT 25-Nov-83 W 153 0 10 O ( 378 CDP-018 R DJS 12-Mar-82 C 86 2 O O 468 CDP-018 R MK 09-Feb-81 W 63 0 4 0 379 CBP-019 R DJS 31-Aug-83 C 275 5 0 0 ( 469 CDP-019 R RLM 07-Dec-81 W 123 0 8 0 380 CDP-020 R TS 06-Dec-83 C 23 0 0 0 470 CBP-020 R DB 19-Nov-83 W 63 0 4 0 ( 381 CDP-021 R KLB 21-Jan-83 C 169 O O O 382 CDP-022 R FJR 18-May-81 C 331 O O O 383 CDP-023 R DJS 11-Mar-82 C 21 O O O ( 384 CBP-024 R DJF 16-Apr-84 C 53 0 0 0 471 CDP-024 R FJR 22-Oct-81 W 33 3 2 1 385 CBP-025 R DJS 18-Nov-81 C 34 2 O O ( 472 CBP-025 R IFD 02-Jul-81 W 33 0 2 0 473 CDP-025 R RLM 12-Nov-81 W 33 0 2 0 386 CDP-026 R DJF 18-Jan-84 C 107 O O O ( 474 CBP-026 R BEB 15-Jul-82. W 123 3 8 2 387 CBP-027 R DJF 30-Nov-83 C 24 0 0 0 388 CDP-028 H DJF 26-Mar-84 C 532 10 0 0 ( 4/5 CDP-028 R SL 26-Mar-81 W 273 0 18 0 389 CDP-029 R KLB 25-Oct-82 C 26 2 O O 390 CBP-030 R DJS 31-Aug-83 C 126 O O O ( 476 CBP-030 R BEB 09-Mar-84 W 63 0 4 0 391 CBP-031 R DJF 08-Dec-83 C 415 4 0 0 477 CDP-031 R FJR 01-Sep-82 W 33 0 2 O ( 477.1 CBP-031 R IFD 10-Jun-81 W 63 0 4 0 477.2 CDP-031 R FJR 27-Oct-81 W 63 0 4 0 392 CBP-032 R DJS 09-Nov-81 C 238 O O O ( 393 CBP-033 R DJF 16-Feb-84 C 405. 2 O O 478 CBP-033 R WJH 17-Feb-84 W 123 0 8 0 479'CBP-033 R BEB 14-Apr-83 W 123 0 8 0 g 394 CBP-034 R BEB 08-Sep-82 C 562 4 0 0 480 CBP-034 R IFD 12-Jan-81 W 213 5 14 4 395 CBP-035 R TS 12-Dec-83 C 165 3 0 0 g. 396 CBP-036 R DJS 11-Mar-82 C 161 O O O 396.1 CBP-036 R FJR 23-Sep-81 C 161 O O O 397 CBP-037 R KLB 08-Sep-82 C 80 6 0 0 ( 398 CDP-038 R DJS O2-Sep-83 C 344 8 0 0 481 CDP-038 R RLM 01-Feb-82 W 123 0 8 0 399 CBP-039 R TS 17-Nov-83 C 243 2 O O ( 482 CDP-039 R KK2 28-Jun-82 W 93 9 6 6 400 CBP-040 R DJS 07-Jul-83 C 56 0 0 O 483 CDP-040 R TLB 23-May-84 W 33 0 2 O ( 401 CBP-041 R TS O2-Nov-83 C 197 4 0 0
l 30-Oct-86 CSR DATABASE VERSION 10/30/86 PAGE 9 o \\> i. ITEM R INSP DATE ATT IP DP WI WD ' (}- 484 CBP-041 R RLM 29-Jan-82 W 93 3 6 3 402 CBP-042 R DJS 12-Jul-83 C 22 O O' O 485 CBP-042 R IFD 02-Jul-81 W 33 0 2 0 (} 403 CBP-043 R DJS 17-Nov-81 C 428 2 O O 486 CBP-043 R IFD 12-Jan-81 W 93 0 6 0 404 CBP-044 R DJF 09-Feb-84 C 67 4 O O (}. 487 CBP-044 R DT 19-Jan-82 W 33 0 2 0 488 CBP-044 R FJR 17-Dec-81 W 33 0 2 0 405 CBP-045 R DJF 12-Jan-84 C 320 0 0 0 {} 489 CBP-045 R CNT 30-Nov-83 W 243 0 16 0 406 CDP-046 R DLP 27-Apr-84 C 20 0 0 0 407 CBP-047 R DJF 28-Dec-83 C 184 0 0 0 ' (} 408 CBP-048 R DJF 10-Feb-84 C 303 7 0 0 490 CDP-048 R IFD 11-Jun-81 W 78 0 5 O l 491 CDP-048 R BEB 15-Jul-82 W-138 0 9 0 [ (} 492 CDP-048 R SL 26-May-81 W 33 0 2 0 409 CDP-049 R DJS 22-Jun-82 C 61 0 0 0 493 CBP-049 R RLM 01-Feb-82 W 33 0 2 O (} 410 CDP-050 R BED 10-Mar-82 C 836 0 0 0 l 494 CBP-050 R BEB 08-Jul-82 W 63 0 4 0 l 494.1 CDP-050 R MK 10-Feb-81 W 63 0 4 0 g 411 CBP-051 R DJS 11-Mar-82 C 327 2 0 0 l 495 CDP-051 R IFD 02-Dec-80 W 213 0 14 0 l 412 CDP-052 R DJF 16-Apr-84 C 166 O O O .g 496 CDP-052 R DLP 17-Mar-84 W 63 1 4 1 497 CBP-052 R FJR 17-Dec-81 W 63 1 4 1 413 CDP-053 R DJS 08-Jul-83 C $9 0 0 0 g 498 CBP-053 R TLB 23-May-84 W 33 1 2 1 414 CDP-054 R DJS 11-Mar-82 C 28 0 0 0 499 CBP-054 R IFD 02-Dec-80 W 63 0 4 0 g 415 CDP-055 R MK 17-Nov-81 C di 0 0 0 t 500 CBP-055 R RAP 30-Aug-84 W 33 0 2 0 415.1 CDP-055 R FJR 29-Jul-81 C 21 0 0 0 l g 416 CEP-056 R DJF 29-Aug-83 C 122 O O O. 501 CDP-056 R MH 29-Nov-83 W 33 0 2 0 417 CBP-057 R DJF 10-Feb-84 C 264 0 0 0 g 502 CBP-057 R IFD 17-Apr-81 W 153 0 10 0 l 410 CDP-058 R DJS 05-Det-81 C 180 0 0 0 l 503 CBP-058 R IFD 26-Mar-81 W 123 0 8 0 g 419 CBP-059 R KLB O2-Jo' 82 C 288 0 0 0 420 CBP-060 R DJS 28-Sep-81 C 144 0 0 0 421 CBP-101 E DJF 13-Dec-83 C 176 2 O O l g 504 CBP-101 E SL 04-Jun-81 W 93 0 6 0 422 CDP-102 E DJS 22-Jun-82 C 154 0 0 0 423 CDP-103 E DJF 06-Mar-84 C 258 2 0 0 ( 505 CDP-103 E DRH 26-Oct-82 W 93 0 6 O l 506 CDP-103 E KK2 15-Dec-82 W 93 0 6 0 507 CDP-103 E KK2 22-Jun-82 W 33 0 2 0 j ( 424 CBP-104 E DJS 12-Jul-82 C 882 5 0 0 l 508 CDP-104 E KK2 12-Jul-82 W 243 0 16 O l 425 CDP-105 E TS 09-Jun-84 C 552 2 0 0 l { 509 CDP-105 E SL 03-Jun-82 W 198 7 13 7 l 509.1 CDP-105 E DT 10-Jul-81 W 198 7 13 7 l 426 CDP-106 E MEW 04-Jun-84 C 274 6 0 0 j ( 510 CDP-106 E MAK 26-Oct-82 W 63 0 4 0 I
$h 30-Oct-86 CSR DATABASE VERSION 10/30/86-PAGE 1 m/ L ITEM R INSP DATE ATT IP DP WI WD , () 511 CBP-106 E CMG 27-Apr-84 W 123 1 8 1 427 CBP-107 E TS 14-Nov-83 C 196 3 0 0 512 CBP-107 E MK 04-Dec-80 W 183 0 12 O (3 428 CBP-108 E FJR 30-Jun-81 C 938 4 0 0 513 CBP-108 E BEB 06-Dec-82 W 93 4 6 4 514 CDP-108 E RLM 10-Oct-81 W 123 0 8 0 (} 429 CDP-109 E..DJS O2-Sep-83 C 459 1 O O t j -430 CBP-110 E DJS O2-Sep-83 C 345 2 O O 515 CBP-110 E RLM 01 -J u l W 63 0 4 0 (} 515.1 CDP-110 E RLM 29-Jan-82 W 33 0 2 O l 431 CDP-111 E DJF 10-Feb-84 C 105 0 0 0 516 CBP-111 E SL 26-May-81 W 93 0 6 0 -{} 517 CBP-111 E IFD 30-Apr-81 W 93 0 6 0 432 CDP-112 E DJS 09-Nov-81 C 176 0 0 0 433 CDP-113 E DJS 22-Jun-82 C 539 1 O O {} 434 CDP-114 E TS 09-Nov-83 C 435 15 0 0 518 CDP-114 E FJR 09-Aug-82 W G3, 0 4 0 435 CDP-115 E KLB 26-Jun-82 C 1033 8 0 0 (} 519 CDP-115 E FJR 08-Jun-82 W 303 6 20 6 435.1 CDP-115 E MSS 30-Jun-81 C 1033 8 0 0 I 436 CDP-116 R DJS 09-Nov-81 C 241 O O O I{} $20 CDP-116 R IFD 02-Jul-81 W 33 0 2 0 l 437 CBP-117 R TS 01-Sep-83 C 22 0 O O i 438 CDP-lid R MK 17-Nov-81 C 22 2 0. O i (} 521 CDP-118 R RAP 11-Sep-84 W 63 2 4' 2 439 CDP-119 R DJF 29-Nov-83 C 10G 4. 0 0 522 CbP-119 R IFD 08-May-81 W 63 0 4 0 () 440 CDP-120 R DJS 05-Oct-81 C 92 4 0 0 523 CDP-120 R SL 13-Jul-82 W 63 0 4 0 441 CDP-121 R TG 07-May-84 C 95 0 0 0 ' (} 524 CDP-121 R DRH 13-Dec-83 W 33 0 2 0 442 CDP-122 R MK 05-Oct-81 C 136 2 0 0 525 CBP-122 R IFD 17-Apr-81 W 33 0 2 0 ' (} 526 CDP-122 R SL 13-Jul-82 W 33 0 2 0 526.1 CBP-122 R SL 10-Apr-81 W 33 0 2 0 443 CBP-123 R DJF 05-Jun-84 C 334 1 O O (} 527 CBP-123 R TMD 22-Nov-83 W 33 0 2 0 528 CDP-123 R DN 28-Nov-83 W 33 0 2 0 529 CBP-123 R LHD 01-May-84 W 33 0 2 0 (} 530 CDP-123 R RLF 30-Apr-84 W 33 0 2 0 l 444 CBP-124 R DJS 09-Nov-81 C 52 O O O i 444.1 CBP-124 R DJF 28-Mar-84 C 52 0 0 0 () 445 CDP-125 R KLB 08-Jul-82 C 78 O O O 531 CDP-125 R SAS 21-Dec-83 W 33 0 2 0 531.1 CDP-125 R MH 03-Dec-83 W 33 0 2 0 () 446 CDP-126 R KLB 20-Oct-82 C 164 0 0 0 532 CBP-126 R SL-26-Mar-81 W 63 0 4 0 533 CDP-126 R RLM 24-Jun-82 W 63 0 4 0 () 447 CDP-127 R KLB 17-Aug-82 C 373 11 O O 448 CDP-12d R DJS 11-Jul-83 C 50 4 0 0 449 CDP-129 R DJF 10-Feb-84 C 200 0 0 0 t ' (} 450 CDP-130 R FJR 12-May-81 C 69 2 0 0 534 CBP-130 R IFD 09-Feb-81 W 93 1 6 1 j 535 CND-001 R KW 02-Feb-83 C 18 4 0 0 l1 536 CND-OO2 R KLB 19-Aug-82 C 59 1 O O j
30-Oct-86 CSR DATABASE VERS 20N 10/30/36' PAGE'& t ITEM R INSP DATE ATT IP DP WI WD g 537 CND-003 R DJS 24-Aug-83 C 18 4 0 0 538 CND-OO4 R SBD 19-Mar-84 C 23 O O O 539 CND-005 R SBD 10-Nov-83 C 34 0 0 0 ( 540 CND-OO6 R KLB' 19-Nov-82 C 84 4 0 0 541 CND-007 R KW 22-Oct-83 C 32 O O O 542 CND-OO8 R KW 24-Oct-83 C 35 2 0 0 g 543 CND-009 R KW. 09-May-84 C 47 0 0 0 544 CND-010 R KW 01-Dec-82 C 47 0 0 0 544.1 CND-010 R KLB 16-Nov-82 C 47 O O O g 545 CND-011 R KW 24-Mar-83 C 31 3 0 0 546 CND-012 R KW 08-Jul-83 C 38 2 0 0 547 CND-013 R SBD 06-Sep-83 C 25' 2 O O g 548 CND-014 R KW 26-Apr-83 C 15 1 O O 549 CND-015-R SBD 26-May-83 C 65 2 O O 550 CND-016 R DJS 22-Oct-83 C 27 2 O O ( 551 CND-017 R SBD 19-Jun-84 C 75 0 0 0 552 CND-018 R BAR 08-Jun-83 C 33 1 0 0 553 CND-019 R MK 15-Jun-81 C 23 1 O O ( 554 CND-020 R KW 18-Nov-83 C 68 0 0 0 555 CND-021 R SBD 20-Feb-84 C 18 2 O O 556 CND-022 R DJS 25-Feb-82 C 227 0 0 O ( 557 CND-023 R SBD 07-Nov-83 C 66 O O O 558 CND-024 R KLB 22-Dec-82 C 86 2 0 0 559 CND-025 R DJS 24-Jan-83 C 18 2 O-O g UGO CND-026 R DJS 05-Jan-64 C 21 0 0 0 561 CND-027 R BEB 05-Mar-82 C 60 0 0 0 SG2 CND-028 R BEB OS-Mar-82 C 43 0 0 0 ( 563 CND-029 R SBD 17-Nov-83 C 40 2 O O 564 CND-030 R KLB 06-Nov-81 C 32 1 0 0 565 CND-031 R SBD 26-May-83 C 92 5 O O ( 566 CND-032 R KW 08-Jul-83 C 38 2 0 0 567 CND-033 R KW 21-Feb-84 C 37 1 O O 568 CND-034 R SBD 19-Jun-84 C 33 0 0 0 ( 569 CND-035 R KW 22-Oct-83 C 31 O O O 570 CND-036 R SBD 28-Feb-84 C 44 0 0 0 571 CND-037 R DJS 26-Apr-83 C 29 1 O O ( 572 CND-038 R BAR 16-Jc.n-84 C 23 0 0 0 573 CND-039 R KW 26-Apr-83 C 54 0 0 0 574 CND-040 R KLB 28-Dec-82 C 43 3 0 0 ( 575 CND-041 R SBD 29-Dec-83 C 59 3 0 0 576 CND-042 R KW 03-Oct-83 C 18 3 0 0 577 CND-043 R SBD 25-Oct-83 C 67 0 0 O ( 578 CND-044 R MDL 14-May-84 C 37 0 0 0 579 CND-045 R KW 31-Oct-83 C 18 2 O O 580 CND-046 R KW 11-Oct-83 C 37 0 0 0 ( 581'CND-047 R KW 25-Apr-84 C 18 2 O O 582 CND-049 R SDD 02-Dec-83 C 66 1 0 0 583 CND-050 R SBD 07-Dec-83 C 46 0 0 0 ( 584 CND-051 R DJS 28-Jul-83 C 57 0 0 0 l 585 CND-052 R KW 16-Nov-83 C 24 0 0 0 l 586 CND-053 R SBD 19-Dec-83 C 29 0 0 0 ( 587 CND-054 R WCB 12-Jun-84 C 26 0 0 0 588 CND-055 R BAR 16-Jul-83 C 52 0 0 0 588.1 CND-055 R KW 12-May-83 C 52 O O O '( 589 CND-056 R KLB 02-Oct-82 C 71 0 0 0
30-Oct-86 CSR' DATABASE VERSION 10/30/86 PAGE 1 1 ~ ' ITEM R INSP DATE ATT IP DP WI WD ( 590 CND-057 R KLB 16-Nov-81' C .48 2 O O 591 CND-058 R DJS 25-Apr-83 C 24 3 0 0 592 CND-059 R CJP 29-May-84 C 15 2 O O .( 593 CND-060 R KW 13-Sep-83 C 39 1-0 0 594 CND-061 R KW 11-Apr-84 C 64 1 O O 595 CND-062 E KLB 10-Aug-82 C 49 2 O O ( 596 CND-063 E SBD O2-Dec-83 C 28 1 O O 597 CND-064 E KW 15-Feb-84 C 32 4 0 0 598 CND-OG5 E KLB 13-Oct-82 C 43 O O O ( 599 CND-066 E SBD 24-Aug-83 C 26 0 0 0 600 CND-067 E KW 21-Oct-83 C 72 3 0 0 601 CND-068 E KLB 18-Nov-81 C 35 2 O O ( 602 CND-OG9 E KLB 27-Aug-82 C 53 2 O O 603 CND-070 E 'DJS 1G-Aug-83 C 89 2 O O 604 CND-071 E KLB 07-Mar-83 C 42 2 O O g 605 CND-072 E 'DJS 19-Apr-83 C 44 0 0 0 606 CND-073 E KLD 05-Nov-82 C 79 5 0 0 607 CND-074 E SBD 20-Jan-84 C 60 2 0 O' { g 608 CND-075 E KW 07-Jun-84 C 33 1 O O l 609 CND-076 E DJS 17-Jan-84 C 26 0 0 0 l 610 CND-077 E KLB O2-Sep-82 C 65-1 O O ( Gli CND-078 E DJS 16-Mar-32 C 42 0 0 0 611.1 CND-078 E MK 11-Aug-81 C 42 O O O 612 CND-079 E KLB 03-Mar-83 C 22 1 0 0 ( 613 CND-OBO E KLD 27-Sep-82 C 84 3 O O 614 CND-081 E KLB G2-S u p-- 82 C 105 1 0 0 615 CND-082 E-KW 15-Jun-84 C 72 1 O O g 616 CND-083 E DJS 01-Dec-83 C 43 2 0 0 617 CND-084 E KLB 07-Oct-82 C 31 1 O O 618 CND-085 E KW 14-Nov-83 C 33 1 0 0 ( 619 CND-086 E KW 23-Feb-84 C 32 4 0 0 620 CND-087 E KW 16-Dec-82 C 32 1 0 0 621 CND-088 E KLB 21-Jan-83 C 70 1 O O ( 622 CND-088 E. DJS 20-May-33 C 70 1 O O 623 CND-089 E KW 25-Jul-83 C 59 0 0 0 624 CND-090 E SBD 07-Mar-G4 C 44 1 0 0 1 625 CND-092 E DJS 25-Feb-82 C 198 O O O 626 CND-093 E KW 14-Jun-84 C 54 2 0 0 627 CND-094 R KW 10-Feb-84 C '40 0 0 0 628 CND-095 R KW 01-Aug-83 C 25 3 0 0 629 CND-096 R -DJS 17-Dec-83 C 17 2 O O 630 CND-097 R KW 08-Sep-83 C 53 1 O O 631 CND-098 R WCB 15-Jun-84 C 33 4 0 0 631.1 CND-098 R SBD 05-Jun-84 C 33 4 0 0 632 CND-099 R KLB 03-Dec-81 C 52 O O O 633 CND-100 R DJS 23-Aug-83 C 29 O O O 634 CND-101 R KW 08-May-84 C 37 3 0 0 G35 CND-102 R MK 15-Jun-81 C 52 0 0 0 636 CND-103 R DJS 16-Mar-82 C 42 O O O 636.1 CND-103 R MK 11-Aug-81 C 42 0 0 0 637 CND-104 R KW 20-Sep-83 C 33 0 0 0 638 CND-105 R SBD 15-Dec-83 C 69 0 0 0 639 CND-106 R KLB 03-Dec-81 C 52 O O O G40 CND-107 R KW O2-Dec-83 C 61 O O O 641 CND-108 R KLB 30-Oct-81 C 57 O O O
30-Oct-86 CSR. DATABASE VERSION 10/30/86 PAGE 1 ITEM R INSP DATE ATT IP DP WI WD 642 CND-109 R SDD 12-Mov-83 C 28 O O O 643 CND-110 R SBD 02-Nov-83 C-58 3 O O 644 CND-111 R KW 11-Oct-83 C 18 O O O 645 CND-112 R KW 14-Feb-84' C-65 _O O O 646 CND-113 R KLB 20-Aug-82 C 44 .2 O O 647 CND-114 R KW 08-Dec-83 C 18 2 O O 648'CND-115 R DJS 25-Feb-82 C. 87 1 O O 649 CND-116 R SBD 29-Oct-83 C 53 0 0 0 650 CND-117 R KW 13-Sep-83 C 51 1 O O 651 CND-118 R KW 22-Nov-83 C 18 O O O 652 CND-119 R' KW 08-Apr-83 C 63 1 O O 653 CND-120- R SBD 07-Nov-83 C 27 0 0 0 654 CND-121 R SBD 06-Mar-84 C 76 2 O O 655 CND-122 E KLB 16-Nov-82 C 18 1 O O G56 CND-123 R KLB. OG-Apr-83 C 43 i O O 657 COH-001 R CNT 02-Mar-84 C 19 0 0 0 715 COH-OO1 R CNT 23-Feb-84 W 183 0 12 0 658 COH-OO2 R JLL 23-May-84 C 10 0 0 0 716 COH-003 R FJR 07-Sop-82 W 273 0 18 0 717 COH-OO4 R MK 06-Feb-81 W 123 4 8 2 659 COH-OO5 R JPH 07-Jan-82 C 10 1 O O 718 COH-OO6 R RLM 08-Jan-8d W 63 0 4 0 ~ 303 2 20 1 719 COH-OO8 R HLM 22-Oct-81 W 660 COH-OO9 R RLM 18-May-83 C 14 0 0 0 720 COH-OO9 R RLM 19-May-83 W 63 0 4 0 661 CCH-011 R CNT 29-Oct-82 C 17 0 0 0 722 COH-011 R WW 18-Jul-81 W G3 0 4 0 723 COH-012 R JVW 03-Apr-84 W 273 3 18 3 724 COH-015 R WW 30-Jun-81 W 273 1 18 1 725 CCH-017 R MK 18-Sep-82 W 363 0 24 0 726 COH-Old R WJH 15-Feb-84 W 48 0 3 0 727 COH-020 R RAS 16-Feb-84 W 273 0 18 0 728 COH-021 R LKB 10-Feb-84 W 153 0 10 0 729 COH-021 R GGN 08-Feb-84 W 153 0 10 0 730 COH-024 R AG O2-Oct-82 W 183 2 12 2 662 COH-026 R JPH 15-Jun-83 C 10 1 O O 731 COH-026 R IFD 09-Feb-81 W 63 4 4 4 732 COH-027 R WJB 30-Mar-84 W 303 2 20 2 733 COH-028 R RAG 03-May-84 W 63 0 4 0 734 COH-029 R RLM 26-Oct-81 W 123 O 8 0 735 COH-030 R KK2 13-Nov-82 W 363 1 24 1 663 COH-031 R RLM 04-Nov-82 C 10 1 O O 736 COH-032 R SL 11-Jan-82 W 183 5 12 5 737 COH-033 R FJR 25-Sep-82 W 123 0 8 0 664 COH-034 R MM 23-Nov-84 C 31 O O O 738 COH-034 R RAG 23-Jun-84 W 33 0 2 0 739 COH-034 R RLW 20-Mar-84 W 123 0 8 0 740 COH-036 R NPC 20-Jan-84 W 63 0 4 0 665 COH-037 R JPH 29-Jul-82 C 5 O O O 741 COH-038 R MPW 17-Feb-84 W 303 0 20 0 742 COH-039 R LOW 08-Feb-82 W 123 0 8 0 666 COH-041 R JPH 20-Oct-81 C 30 2 O O 743 COH-041 R IFD 05-Mar-81 W 243 0 16 0 744 COH-041 R DT 30-Jul-81 W 243 0 16 0 667 COH-042 R CNT 13-Oct-82 C 19 0 0 0 e
m-
r-30-Oct-86 CSR DATABASE VERSION 10/30/86 PAGE 1 ITEM R INSP-DATE ATT IP DP WI WD 745 COH-042 R DRH 14-Oct-82 W 273 0 18 0 746 COH-042 R KK 26-Nov-82 W 273 0 18 0 747 COH-043 R MAK 20-Oct-83 W 48 0 3 0 748 COH-043 R TMD 27-Sep-83 W 48 0 3 0 668 COH-044 R CNT 30-Dec-82 C 12 O O O 749 COH-044 R KK2 03-Nov-82 W 123 2 8 2 g 750 COH-044 R DRH 11-Oct-82 W 123 2 8 2 751 COH-045 R DGC-30-Aug-83 W 123 0 8 0 669 COH-046 R DP 12-Feb-83 C 6 0 0 0 .g 753 COH-046 R .DP 13-Dec-82 W 63 0 4 0 754 COH-047 R GGN 13-Apr-84 W 123 0 8 0 670 COH-048 R JLL 29-Feb-84 C 15 0 0 0 ( 755 COH-048 R GGN 24-Jan-84 W 123 0 8 0 75G COH-049 R GGN 23-Feb-84 W 33 3 2 3 671 COH-050 R JPH 16-Oct-81 C 23 1 O O g 757 COH-050 R SL 15-Jul-81 W 153 1 10 1 672 COH-052 R RLM 15-Sep-82 C 11 0 .O O 753 COH-052 R MK 16-Jul-81 W 93 2 6 2 g 673 COH-053 R CNT 16-Mar-83 C 10 0 0 0 759 COH-053 R MAK 10-Jan-83 W 63 0 4 0 674 COH-054 R JPH 08-Feb-84 C 14 0 0 0 760 COH-054 R TMD 03-Feb-84 W 123 0 8 0 761 COH-055 R SL 10-Feb-81 W G33 16 42 12 675 COH-058 R JPH 04-Jan-82 C 30 2 0 0 762 COH-058 R RLM 09-Oct-81 W 273 0 18 0 763 COH-059 R HWS 31-May-G4 W 273 0 18 0 764 COH-060 R RLM 04-Jan-82 W 93 5 6 5 765 COH-062 R AG 21-Oct-82 W 03 6 6 5 766 COH-063 R BEB 25-Sep-82 W 63 0 4 0 676 COH-064 R MH 23-Mar-84 C 20 0 0 0 767 COH-064 'R MAK 13-Mar-84 W 123 0 8 0 G77 COH-065 R KLB iS-Mar-82 C 32 0 0 0 769 COH-065 R KK2 10-Dec-81 W 363 5 24 4 770 COH-066 R DEB 09-Oct-82 W 63 4 4 4 678 COH-067 R DRH 22-Jun-84 C 21 2 O O 771 COH-067 R DRH 22-Jun-84 W 123 1 8 1 679 COH-068 R CNT 16-Mar-83 C 22 O O O 772 COH-068 R MAK 10-Jan-83 W 93 0 6 0 773 COH-069 R MK 23-Apr-81 W 453 6 30 6 774 COH-070 R BEB 25-Aug-82 W 153 0 10 0 680 COH-071 R MM 18-Jun-84 C 5 0 0 0 681 COH-072 R LP 09-Feb-82 C 55 1 0 0 775 COH-072 R SL 08-Aug-81 W 393 3 26 3 682 COH-073 R KLD 03-Nov-83 C 21 0 0 0 776 COH-073 R MAK O2-Nov-83 W 153 0 10 0 683 COH-074 R CNT 22-Dec-82 C 16 0 0 0 777 COH-074 R KK2 23-Dec-82 W 123 0 8 0 684 COH-075 R CNT 29-Mar-83 C 11 0 0 0 778 COH-075 R SL 10-Sep-82 W 33 0 2 0 685 COH-076 R MH 24-Aug-83 C 5 0 0 0 686 COH-077 R CNT 18-Jul-83 C 28 4 0 0 780 COH-077 R TML 13-Sep-83 W 333 4 22 4 781 COH-101 E RLM 03-Dec-81 W 33 0 2 0 782 COH-102 E RLM 23-Oct-81 W 123 1 8 1 687 COH-103 E RLM 08-Apr-83 C 21 O O O
30-Oct-86 CSR DATABASE VERSZON 10/30/86 PAGE 1 ITEN H INSP DATE ATT IP DP WI WD 783 COH-103 E DHH 20-Jan-83 W 123 0 8 0 784 COH-104 E DT 28-Sep-81 W 93 0 6 0 G88 COH-105 E CNT 04-Nov-81 C 90 0 0 0 688.1 COH-105 E RLM 20-Jul-81 C 90 0 0 0 785 COH-105 E DT 18-Sep-81 W 543 5 36 4 689 COH-106 E RLM 16-Sep-82 C 35 0 0 0 786 COH-106 E RLM 17-Feb-82 W 243 2 16 2 787 COH-107 E RLM 03-Dec-81 W 273 2 18 2 690 COH-108 E RLM 19-Oct-82 C 11 0 0 0 788 COH-108 E IFD 27-Jun-81 W 63 0 4 0 691 COH-109 E BEB 12-Mar-83 C 21 0 0 0 789 COH-110 E RLM 05-Oct-81 W 183 5 12 5 790 COH-111 E RLM 05-Oct-81 W 273 0 18 0 692 COH-112 E LP 10-May-83 C 73 .1 O O 791 COH-112 E LOW 11-Feb-82 W 603 18 40 14 693 COH-113 E JPH 20-Aug-82 C 20 0 0 0 792 COH-113 E DP 19-Aug-82 W 93 0 6 0 793 COH-114 E SL 22-Nov-82 W 153 0 10 0 794 COH-115 E RLM 26-Oct-81 W 243 0 16 0 694 COH-116 E MK 03-Dec-81 C 21 O O O 795 COH-116 E DT 12-Nov-80 W 153 0 10 0 695 COH-il7 E CNT 18-Jul-83 C 38 1 O O 796 COH-117 E IFD 23-Fuo-81 W 423 3 28 3 696 COH-118 E EL 12-Apr-82 C 32 O O O 797 COH-118 E IFD 20-Mar-81 W 363 7 24 7 798 CCH-119 E KK2 14-Oct-82 W 483 0 32 O G97 COH-120 E GED 13-Jan-82 C 145 1 0 0 799 COH-120 E IFD 16-Dec-80 W 603 3 40 3 800 COH-122 E FJR 30-0ec-82 W 183 4 12 4 801 COH-122 E FJR 29-Sep-82 W 183 4 12 4 802 COH-123 E FJR 29-Sop-82 W 393 2 26 2 698 COH-124 E JPH 10-Feb-83 C 13 0 0 0 803 COH-124 E FJR 05-Oct-82 W 33 0 2 0 804 COH-125 E RLM 05-Oct-81 W 163 0 10 0 805 COH-127 E RLM 26-Oct-81 W 303 0 20 0 30G.1 COH-128 E RLM 26-Oct-81 W 203 1 20 1 699 COH-129 E MAK 16-Mar-84 C 17 0 0 0 807 COH-129 E MAK 16-Mar-84 W 123 0 8 0 809 COH-129 E DP 24-Mar-83 W 123 0 8 0 810 COH-130 E RLM 05-Oct-81 W 423 0 28 0 811 COH-131 E DT 12-Aug-81 W 333 0 22 0 812 COH-132 E MAK 29-Jul-83 W 153 0 10 0 813 COH-133 E TML 28-Nov-83 W 423 2 28 2 815 COH-134 E FJR 18-Sep-82 W 363 0 24 0 816 COH-135 E FJR 13-Sep-82 W 303 0 20 0 700 COH-136 E CNT 03-Mar-83 C 28 1 O O 817 COH-136 E MAK 28-Feb-83 W 423 2 28 2 l 818 COH-137 E KK2 03-Nov-82 W 393 1 26 1 701 COH-138 E MH 22-Mar-34 C 32 2 0 0 819 COH-138 E MH 22-Mar-84 W 303 0 20 0 702 COH-139 E LP 27-Jan-82 C 45 5 0 0 820 COH-139 E IFD 12-May-81 W 543 0 36 0 821 COH-139 E JAM 14-Mar-84 W 543 0 36 0 703 COH-140 E SL 12-Apr-82 C 47 0 0 0 822 COH-140 E IFD 20-Mar-81 W 573 0 38 0 l
30-Oct-86 CSR DATABASE VERSION 10/30/86 PAGE 1 0 ITEM R. INSP DATE' ATT IP DP WI WD (} 823 COH-140 E DGC 20-Sep-83 W 573 0 38 0 824 COH-141 E BEB 11-Sep-82 W 123 0 8 0 825 COH-142 E KK2 03-Nov-82 W 423 0 28 0 () 704 COH-143 E JLL 07-Feb-84 C 24 0 0 0 826 COH-143 E MAK 02-May-83 W 273 2 18 1 705 COH-144 E THS 10-Jan-84 C 31 3 0 0 () 827 COH-144 E DN 01-Nov-83 W 393 1 26 1 828 COH-145 E WJH 11-Apr-84 W 123 0 0 0 829 COH-146 E TML 08-Dec-83 W -453 4 30 4 () 706 COH-147 E KLB 27-Sep-83 C 29 0 0 0 830 COH-147 E KK2 18-Jan-83 W 363 1 24 1 831 COH-148 E KK2 01-Nov-82 W 213 2 14 2 () 832 COH-149 E FJR 07-Jun-84 W 393 0 26 0 833 COH-149 E RLM 21-Jan-82 W' 393 0 26 0 707 COH-150 E JLL 12-Mar-84 C 12 O O O {} G34 COH-150 E TMD 06-Mar-84 W 123 0 8 0 708 COH-151 E AG O2-Jun-83 C 24 0 0 0 708.1~CCH-151 E CNT 22-Apr-83 C 24 0 0 0 ()' 835 COH-151 E MAK 29-Apr-83 W 318 0 21 0 836 COH-152 E TML 08-Duc-83 W 453 4 30 4 709 COH-153 E MH 13-Sep-83 C 24 0 0 0 g 837 COH-153 E MH 13-Sop-83 W 303 1 20 1 '710 COH-154 E LP 15-Jan-82 C 33 2 O O 838 COH-159 E RLM 19-Oct-81 W 333 1 22 1 ( '711 COH-155 E DRH 28-Feb-84 C 33 3 O O 839 COH-155 E DRH 28-Feb-84 W 273 0 18 0 840 COH-156 E IFD 11-May-81 W 393 0 26 0 g 841 COH-15/ E NAK 29-Jun-83 W 273 8 18 6 712 COH-158 E CNT 25-Jan-84 C 34 2 O O 842 COH-158 E HAK 27-May-83 W 393 0 26 0 g 713 COH-159 E CNT 13-Oct-82 C 16 O O O 843 COH-159 E KK2 18-Oct-82 W 123 0 8 0 844 COH-160 E RLM 26-Oct-81 W 273 1 18 1 g 714 COH-161 E THS 24-Jan-84 C 31 0 0 0 845 COH-161 E RLM 22-Oct-81 W 273 0 18 0 846 COH-161 E RAS 05-Jan-84 W 27.3 0 18 0 g 847 CPH-001 R MK 12-Jan-81 W 963 1 64 1 848 CPH-002 R BEB 14-Oct-82 W 108 0 7 0 849 CPH-GO3 R RY 22-May-79 W 633 10 42 9 g 850 CPH-004 R IFD 15-Jan-81 W 603 0 40 0 851 CPH-005 R TLB 21-Dec-83 W 93 0 6 O G53 CPH-006 R GY 13-Jun-78 W 543 8 36 5 ( 854 CPH-007 R GY 16-May-78 W 1683 20 112 17 855 CPH-008 R RLM 19-Feb-82 W 303 5 20 3 856 CPH-OO9 R WCB 27-Jan-84 W 1833 41 122 36 ( 857 CPH-010 R DRH 18-Feb-83 W 483 0 32 .O 858 CPH-011 R JBH 31-Jul-79 W 363 2 24 2 859 CPH-Old R DN 26-Oct-83 W 513 4 34 4 ( 860 CPH-012 R MAK 14-Sep-83 W 513 4 34 4 861 CPH-013 R IFD 11-Feb-81 W 543 25 26 17 862 CPH-015 R IFD 24-Jun-81 W 393 4 26 4 ( 863 CPH-016 R GY 21-Feb-78 W 1563 17 104 15 864 CPH-017 R BEB 03-Sep-82 W 468 0 31 0 865 CPH-019 R RY 30-Jun-80 W 513 0 34 0 j 866 CPH-020 R RY 12-Jun-79 W 1083 10 70 10
.. ~. _. - -. 30-Oct-86 CSR-DATABASE VERSION 10/30/86 PAGE 1 ITEM .R INSP DATE ATT IP DP WI WD g _867 CPH-020 R DRH..16-Apr-83 W 243 2 16 2 868 CPH-021 R RLM 01-Dec-81 W "213 0 14 0 869 CPH-022 R SL 28-Jul-81 W 1533 9 102 7' g 870 CPH-023 R RLM 18-Feb-82 W 633 2-42 2 871 CPH-025 R GY 31-May-78 W 1233 22 82 22 872 CPH-026 R DT- 02-Jul-81 W 813 3 54' 3 Lg 873 CPH-026 R SL 20-Jun-81 W 813 3 54 3 874 CPH-027 R BEB 26-Oct-82 W 303 2 20 1 675'CPH-028 R IFD 22-Dec-80 W 693 6 4G 5 '( 876 CPH-029 R RY O2-Jul-79 W 183 1 12 1 877 CPH-030 R.DRH 18-Feb-83 W 453 2 30 2- -877.1 CPH-030 R DRH 01-Dec-82 W 243 8 16 4 ,( 878 CPH-031-R GY 21-Mar-78 W 123 1 8 1 879 CPH-032 R TLB 21-Dec-83 W 123 4 8 4 880 CPH-033 R GY 22-Nov-78 W 903 34 60 32 <g 881 CPH-034 R RLM-18-Feb-82 W 393 0 26 O l 882 CPH-034 R EEB 13-Aug-82 W 393 0 26 0 883 CPH-035 R TLB 10-Jan-84 W 1023-13 68 12 '.( 884 CPH-036 R JBH 31-Jul-79 W 2283 7 152 7 885 CPH-036 R IFD 27-Jan-81 W 2283 7 152 7 886 CPH-037 R MAK 01-Dec-82 W 1113 26 74 13 l fg 887 CPH-037 R DRH 28-Dec-82 W 1113 26 74 15 888 CPH-038 R DED 20-Duc-84 W 108 0 7 0 839 CPH-039 R IFD 30-Jan-81 W 1143 35 7G 32 'l 690 CPH-039 R DY 09-Jul-80 W 1143 35 76 a2 891 CPH-040 R RLM 05-Jan-82 W 1113 19 74 in 892 CPH-041 R RY 08 --M ay-79 W 1216 20 81 17 893 CPH-042 R GY 21-Feb-78 W 2613 73 174 58 894 CPH-043 R GY 18-Jan-79 W G48 8 43 8 895 CPH-043 R RY 22-May-79 W 648 8 43 8 i t 896 CPH-044 R RY 08-May-79 W 873 8 58 8-897 CPH-045 R RLM 27-Nov-81 W 1053 17 70 16 898 CPH-046 R RLM 01-Dec-81 W 153 0 10 0 f l, 899 CPH-047 R RLM 10-Dec-81 W 423 4 28 4 900 CPH-048 R MAK 12-Jul-83 W 1233 9 82 7 l 901 CPH-049 R DT 21-Sep-81 W 183 0 12 0 902 CPH-050 R RY 08-May-79 W 903 16 60 1G l 903 CPH-051 R TML 17-Aug-83 W 693 10 46 6 904 CPH-051 R NPC 13-Apr-84 W 693 10 46 6 i 905 CPH-052 R DT 10-Jul-81 W 483 5 32 4 906 CPH-053 R IFD 20-Jan-81 W 843 1 56 1 907 CPH-053 R IFD 22-Dec-80 W 843 1 56 1 -s 908 CPH-054 R SL 15-Jul-81 W 813 19 54 16 909 CPH-055 R BL 10-Mar-81 W 483 4 32 4 910 CPH-055 R RY 06-Aug-80 W 483 4 32 4 i 911 CPH-056 R BEB 30-Sep-82 W 273 0 18 0 912 CPH-057 R 1FD 22-Dec-80 W 603 6 40 6 913 CPH-058 R KK2 22-Nov-82 W 1203 16 80 10 s. 914 CPH-059 R GY 22-Nov-78 W 63 3 4 3 915 CPH-060 R GY 27-Mar-78 W 123 0 8 0 916 CPH-101 E IFD ~03-Apr-81 W 1263 19 84 1G 917 CPH-102 E IFD 20-Jan-81 W 1143 13 76 13 918 CPH-103 E IFD 22-Dec-80 W 543 0 36 0 919 CPH-104 E IFD 15-May-81 W 1923 41 128 36 920 CPH-104 E RLM 08-Feb-82 W 1923 41 128 36 i .s.
r 1 l i l 30-Oct-C6 CSR DATABASE VERSION 10/30/86 PAGE 1 lI l l ITEM R INSP DATE ATT IP DP WI. WD (( 921 CPH-105 E SL 01-May-81 W 873 20 58 15 l 922 CPH-108 E SL 30-Jun-81 W 1023 5 68 5 I 923 CPH-110 E RY 22-May-79 W 1173 2 78 2 ( 924 CPH-110 E GY. 18-Jan-79 W 1173 2 78 2 925 CPH-111 E SL 27-Apr-81 W 1248 8 83 7 926 CPH-112 E IFD 17-Dec-80 W 843 9 56 9-( 927 CPH-113 E GY 09-Oct-78 W 1293 35-BG 31-928 CPH-114 E RY 08-May-79 W 903 19 60 15 l 929 CPH-115 E SL 17-Feb-82 W 663 19 .44 19 ( 930 CPH-116 E SL 18-Feb-81 W 1143 13 76 12 931 CPH-116 E RY 28-Jun-79 W 1143 13 76 12 932 CPH-117 E GY 09-Oct-78 W 903 3 60 3 '( 933 CPH-118 E GY 22-Nov-78 W 1563 8 104 7 934 CPH-119 E RLM 07-Oct-81 W 873 20 58 18 935 CPH-119 E DT 02-Jul-81 W 873 20 58 18 ll 936 CPH-120 E. RAG 19-Jun-84 W 723 7 48 7 937 CPH-121 E MK 05-Feb-81 W 393 0 26 -O 938 CPH-122 E SL 05-Mar-81 W 1533 28 102 22 l( 939 CPH-122 E RY 06-Aug-80 W 1533 28 102 22 940 CPH-123 E MK 08-Dec-80 W 2433 32 162 28 l 941 CPH-125 E DT 07-Aug-81 W 1143 36 76 26 ( 942 CPH-126 E GY 18-Jan-79 W 693 5 46 4 943 CPH-126 E HY 22-May-79 W 693 5 46 4 944 CPH-127 G RY 22-May-79 W 813 7 54 G i( 945 CPH-127 E GY 18-Jan-79 W 813 7 54 6 94G CPH-128 .E RY 08-May-79 W 1083 14 72 12 947 CPH-129 E RY 08-May-79 W 1443 8 96 8 ( 948 CPH-129 E MK 09-May-81 W 1443 8 96 8 949 LPH-130 E RY 07-AuG-80 W 1743 36 116 25 l 950 CPH-130 E DT 22-Fsb-82 W 1743 36 116 35 t 951 CPH-130 E RLM 14-Oct-81 W 1743 36 116 3S 952 CPH-131 E DT 05-Jan-82 W 1413 22 V4 22 953 CPH-132 E GY 21-Feb-78 W 1323 31 88 28 934 CPH-132 E SL 01-Apr-81 W 1323 31 88 2d 955 CPH-133 E DT 11-Jan-82 W 2043 29 136 23 956 CPH-135 E DT 25-Feb-02 W 453 18 30 18 I t 957 CPH-136 E GY 18-Jan-79 W 873 21 58 18 960 CPH-138 E GY 17-Apr-78 W 1203 20 60 19 961 CPH-139 E MK 04-May-81 W 303 4 20 4 l 962 CPH-139 E IFD 17-Apr-81 W 993 16 66 13 963 CPH-140 E GY 18-Jan-79 W 1293 8 86 6 964 CPH-140 E RY 22-May-79 W 1293 8 86 6 i ( 965 CPH-141 E SL 02-May-81 W 3033 88 202 75 966 CPH-141 E IFD 26-Mar-81 W 3033 88 202 75 l 967 CPH-142 E SL 20-Mar-81 W 678 2 45 2 ( 968 CPH-144 E RLM 01-Feb-82 W 1443 2 96 2 969 CPH-146 E RY 14-Jun-79 W 1203 11 80 10 970 CPH-147 E IFD 24-Apr-81 W 1323 14 08 14 e 971 CPH-149 E DT 18-Feb-82 W 993 1 66 1 972 CPH-150 E SL 09-Feb-81 W 783 26 52 25 973 CPH-150 E DT 16-Jun-80 W 783 26 52 22 ) 974 CPH-150 E MK 11-Mar-81 W 303 4 20 4 975 CPH-151 E RY 13-Jun-79 W 1323 41 88 34 i 976 CPH-153 E SL 05-Aug-81 W 933 20 G2 16 977 CPH-154 E RLM 13-Nov-81 W 2043 26 136 25
(- m ~ ~ l j 's 30-OctL86' CSR DATABASE VERSION 10/30/86 PAGE 1 !C l N.. -N ITEM. R INSP-DATE ATT IP DP WI WD l g 978 CPH-154 E SL 18-Sep-82 W 2043 26 ' 136 25 979 CPH-155 E SL 20-Mar-81 W 678 3 45 3 ( 980 CPH-156 E' DED 27-Aug-82 W 1263 4 84 4 l g-981 CPH-156 C TLB 10-Jan-84 W 1263 4 84 4 l 982 CPH-157 E, RY 27-Aug-80 W 1393 10 93 10 l 983 CPH-158 E 'IFD 15-Jan-81 W 843 8 56 7 l ( 984 CPH-158 E RY 08-Aug-79 W 843 8 56 7 l , 985 CPHJ159.. E RLM 19-Oct-81 W 1353 10 90 10 1 987 CPH-161 E ~RLM 11-May-83 W 1893 49 126 46 ( 988 CPH-162 E MK 29-Jar.-81 W 1338 43 89 36 l 989 CPH-164 E RLM 05-Oct-81 W 543 2 36 2 l 990 CPH-165 E BEB 13-Aug-82 W 543 0 36 0 ,( '991 CPH-165 E RLM 18-Dec-82 W 543 0 36 0 993 CPH-166 E RY 06-Aug-80 W 1863 16 124 15 994 CPH-166 'E SL 27-Feb-81 W 1863 16 124 15 , g' 995 LPH-167 E RY 22-May-79 W 783 2 52 2 996 CPH-167 E IFD 15-Apr-81 W 783 2 52 2 I 997 CPH-168 E SL 18-Sep-82 W 963 32 64 32 l g 998 CPH-16G E RLM 13-Nov-81 W 963 32 64 32 999 CPH-169 E SL 11-Mar-81 W 1443 20 96 11 1000 CGH-170 E IFD 19-Jun-81 W 2073 31 138 25 ( 1001 CPH-171 E RLM 01-Feb-82 W 2493 2 166 2 1002 CPH-171 E IFD 06-Jan-80 W 2493 2 166 2 1003 LPH-172 E SL 11-May-81 W 963 18 64 14 l g 1005 EIN-001 R TW Z Apr-84 C 11 0 0 0 1006 EIN-OO2 R KLB 06-Jun-83 C 102 4 0 0 1141 EIN-002' R MK 18-Sop-82 W 873 0 58 0 ( 1007 EIN-OO3 R FJR 27-Oct-83 C 113 5 0 0 114e EIN-003 R DGC 19-Jul-83 W 423 0 28 0 1008 EiN-OO4 R TWZ O2-May-64 C 33-0 0 0 l ( 1t43 EIN-004 R TWZ 03-May-34 W -127 0 8 0 1009 EIN-OO5 R TWZ 23-Apr-84 C 9 4 0 0 l 1010 EIN-006 R M'_ B7 07-May-84 C 49 13 0 0 ' l 1011 EIN-007 R TWZ' 17-Feb-84 C 9 0 0 0 1012 EIN-008 R DAR 25-Aug-83 C 41 3 0 0 1144 EIN-OO8 R DP 25-Aug-83 W 71 0 5 0 ~ ( 1145 EIN-008 R DGC 31-Aug-83 W 71 0 5 0 1013 EIN-O:0 R KLD 16-Dec-81 C 35 2 0 0 1014 EIN-011 R MLb 12-Dec-83 C 68 1 0 0 l (- 1147 EIN-011 R.FJR 12-Dec-83 W 453 5 30 4 1015 EIN-012 R MLB 10-Mar-84 C 10 0 0 0 1016 EIN-013 R MLB 10-Mar-84 C 9 0 0 0 . ( 1017 EIN-014 R DJS 03-Feb-82 C 13 0 0 0 1018 EIN-015 R MLB 14-Mar-84 C 5 1 O O 1019 EIN-016 R DAR 12-Jan-84 C 13 1 0 0 l ( 1148 EIN-017 R FJR 09-Jun-84 W 723 3 48 3 1021 EIN-018 R TW2 10-Mar-84 C 9 0 0 0 i 1022 EIN-019' R DJS 05-Feb-82 C 45 5 O O g 1149 EIN-019 R RLM 29-Jan-82 W 397 2 26 2 1023 EIN-020 R MLB 13-Mar-84 C 33 4 0 0 l 1150 EIN-020 R FJR 26-Oct-83 W 183 0 12 0 ll 1024 EIN-022 R JVW 08-Jun-84 C 13 0 0 0 1025 EIN-023 R TWZ 10-Jan-84 C 16 1 0 0 1151 EIN-023 R JVW 09-Jun-84 W 303 2 20 2 [ 1152 EIN-001 R KK 20-Aug-82 W 303 2 20 2 t
) 30-Oct-86 CSR DATABASE VERSION 10/30/86 PAGE 2 C) f} 1C126 EIt-4 R fW 06-J 84 C 9 0 0 0 1027 EIN-025 R MLB 18-Jun-84 C 39 4 0 0 1155 EIN-025 R SL 21-Feb-83 W 123 0 8 0 (3 1028 EIN-Od6 R TWZ 21-Mar-84 C 19 2 0 0 { 1029 EIN-027 R TWZ 05-May-84 C 61 O O O I 1156 EIN-027 R TWZ 05-May-84 W 603 0 40 0 (} 1030 EIN-028 R MLB 07-Jun-84 C 9 4 O O 1031 EIN-029 R KLB 29-Sep-81 C 54 0 0 0 1157 EIN-029 R WW 20-Jul-81 W 303 12 20 9 {} 1032 EIN-030 R MLB. 25-Feb-84 C 13 0 0 0 1033 EIN-031 R TWZ 04-Jun-84 C 63 3 0 0 1158 EIN-031 R MAK 25-Jan-83 W 123 5 8 5 (} 1034 EIN-032 R FJR 01-Dec-83 C 5 2 O O 1035 EIN-033 R JVW 31-Mar-84 C 9 0 0 0 1036 EIN-034 R KLB 22-Sep-82 C 51 1 O O () 1159 EIN-034 R DP 07-Feb-83 W 243 0 16 0 1037 EIN-035 R MLB 06-Mar-84 C 23 O O O 1160 EIN-035 R FJR 10-Nov-83 W 63 0 4 0 {} 1161 EIN-035 R MLB 06-Mar-84 W 63 0 4 0 1038 EIN-036 R MLB 13-Mar-84 C 71 8 0 0 1162 EIN-036 R WJH 16-Aor-84 W 243 0 16 0 {} 1163 EIN-036 R FJR 22-Nov-83 W 183 10 12 9 1039 EIN-037 R NK 16-May-83 C 11 1 0 0 1040 EIN-038 R MLB 10-Mar-84 C 30 6 0 0 j{} 1041 EIN-039 R MLb 13-Mar-84 C 33 0 0 0 1164 EIN-039 R FJR 26-Oct-83 W 183 3 12 3 1042 EIN-040 R JLL 24-Jan-84 C 51 O O O
- (}
1043 EIN-041 R FJR 13-Jun-84 C 30 0 0 0 1165 EIN-041 R FJR 13-Jun-84 W 123 0 8 0 1044 EIN-042 R DJS 22-Sep-83 C 74 5 0 0 () 1166 EIN-042 R DJS 22-Sep-83 W 783 0 52 0 1045 EIN-043 R DJS 09-Nov-82 C 9 1 0 0 1046 EIN-044 R FJR 13-Sep-83 C 56 0 0 0 () 1167 EIN-044 R FJR 12-Apr-84 W 453 0 30 0 1047 EIN-045 R~ FJR 12-Apr-84 C 9 0 0 0 1048 EIN-046 R MLB 27-Apr-34 C 6 0 0 0 ,l(} 1168 EIN-046 R SL 29-Sep-82 W 63 0 4 0 1049 EIN-047 R TWZ 16-Jun-84 C 33 2 0 0 l 1169 EIN-047 R KK2 05-Mar-82 W 63 0 4 O () 1050 EIN-048 R BAR 07-Nov C 5 0 0 0 l 1051 EIN-049 R KLB 22-Sep-82 C 58 O O O 1170 EIN-049 R DP 17-May-83 W 423 11 28 6 g 1052 EIN-050 R BAR 01-Nov-83 C 5 O O O l 1053 EIN-051 R MLB 26-Mar-84 C 9 0 0 0 1054 EIN-052 R BAR 04-Oct-83 C 19 0 0 0 g 1171 EIN-052 R FJR 04-Oct-83 W 63 2 4 2 1055 EIN-053 R TWZ 13-Jun-84 C 33 0 0 0 1172 EIN-053 R MAK 10-Feb-83 W 63 0 4 0 g 1056 EIN-054 R' BAR 06-Sep-83 C 31 2 O O 1173 EIN-054 R CNT 06-Sep-83 W 183 0 12 0 1057 EIN-055 R DJS 10-Feb-82 C 61 3 0 0 ( 1174 EIN-055 R LOW 09-Feb-82 W 423 6 28 6 t 1058 EIN-056 R DJS 10-Feb-82 C 62 3 0 0 1175 EIN-056' R LOW 09-Feb-82 W 573 20 38 19 ( 1059 EIN-057 R BAR 06-Jan-84 C 5 0 0 0 l
b 30-Oct-C6 CSR DATABASE VERSION 10/30/0G PAGE 2. O = ITEM R INSP DATE ATT IP DP WI WD {} 1177 EIN-057 R JVW 14-Apr-84 W 633 0 42 0 1178 EIN-057 R RY 10-Nov-80 W 633 0 42 0 1060 EIN-058 R DJS 14-Jan-84 C 5 0 0 0 {} 1179 EIN-058 R MLB 24-Feb-84 W 303 2 20 2 1061 EIN-059 R MLB 16-Jun-84 C 37 1 O O 1180 EIN-059 R RLM 29-Jan-82 W 63 6 4 4 {} 1062 EIN-060 R KLB 27-May-83 C 35 0 0 0 1181 EIN-060 R DP 06-Apr W 63 0 4 0 1063 EIN-061 R MLB 25-Feb-84 C 9 0 0 0 {} 1182 EIN-061 R MLB 25-Feb-84 W 63 0 4 0 1064 EIN-062 R FJR 08-Nov-83 C 33 3 0 0 1183 EIN-062 R FJR 08-Nov-83 W 123 0 8 0 () 1065 EIN-063 R MLB 26-Jan-84 C 96 27 0 0 1184 EIN-063 R MLB 26-Jan-84 W 363 0 24 0 1004 EIN-064 R MSS 04-May-81 A 24 2 O O {} 1066 EIN-064 R MK 13-Jul-81 C 31 O O O 11Q5 EIN-064 R WW 13-Jul-81 W 63 4 '4 4 1067 EIN-065 R JVW 05-Jun-84 C 5 0 0 0 {} 1068 EIN-066 R TWZ 16-Feb-84 C 42 2 O O 1186 EIN-066 R TWZ 16-Feb-84 W 243 0 16 0 1187,EIN-066 R FJR 26-Apr-84 W 103 0 12 O (} 1069 EIN-067 R JVW. 02-Apr-84 C 66 O O O 1070 EIN-068 R DJS 15-Oct-81 C 49 2 O O 1071 EIN-069 R KLB 29-Sep-81 C' 35 O O O {} 1188 EIN-069 R DT 30-Sep-81 W 423 0 28 0 1072 EIN-070 R BAR 01-Nov-83 C 71 2 O O 1073 EIN-071 R FJR 13-Sep-83. C 97 11 O O (} 1189 EIN-071 R FJR 03-Neiv-83 W 603 0 40 0 1074 EIN-072 R DJS 10-Feb-82 C 26 1 O O 1075 EIN-073 R DJS 03-Feb-82 C 26 5 0 0 (} 1076 EIN-074 R DJS 14-Oct-81 C 29 0 0 0 1077 EIN-075 R TWZ 12-Apr-84 C 63 1 O O 1190 EIN-075 R FJR 27-Apr-84 W-423 0 28 0 (} 1078 EIN-076 R KLB 09-Sep-82 C 5 1 O O 1079 EIN-077 R MLB 24-Feb-84 C 157 0 0 0 1192-EIN-077 R SL 27-Jul-82 W 1278 0 85 0 (} 1080 EIN-078 R BAR 04-Aug-83 C 87 6 0 0 1193 EIN-078 R DJA 03-Jul-84 W 363 4 24 4 1081 EIN-079 R MLB 05-Jun-84 'C 5 1-0 0 ,(} 1082 EIN-080 R MLB 20-Mar-84 C 5266 i O O 1083 EIN-081 R BAR 10-Feb-84 C 13 0 0 0 1196 EIN-081 R IFD 23-Dec-80 W 513 0 34 0 () 1197 EIN-081 R TWZ 12-Mar-84 W 513 0 34 0 1084 EIN-101 E BAR 12-Jan-84 C 24 O O O 1198 EIN-101 E FJR 10-Jan-84 W 153 2 10 2 () 1085 EIN-102 E KLB 23-Feb-82 C 123 O O O 1199 EIN-102 E RLM 08-Oct-81 W 693 1 46 1 1200 EIN-102 E DP Feb-83 W 693 1 46 1 () 1086 EIN-103 E JLL 24-Jan-84 C 51 O O O 1087 EIN-104 E BAR 10-Jan-84 C 16 1 O O 1201 EIN-104 E MAK 12-Apr-83 W 123 9 8 8 l () 1202 EIN-104 E KK2 19-Aug-82 W 123 9 8 8 1088 EIN-105 E KLB 09-Jul-82 C 1464 44 0 0 l l'089 EIN-106' E MLB 24-Feb-84 C 36 0 0 0 ' () 1203 EIN-106 E MLB 12-Jan-84 W 483 0 32 O t o-
e 3 30-Oct-86 CSR DATABASE VERSION 10/30/86 PAGE 2. w ITEM R INSP -DATE ATT IP DP WI WD 1204 EIN-106 E..KK2 19-Aug-82 W 483 0 32 0 1090 EIN-107 E DJS 20-Feb-84 C 28 0 0 0 1207 EIN-107 E FJR 27-Jan-83 W 363 4 24 4 1091 EIN-108-E DJS 20-Feb-84 C 28 0 0 0 1208 EIN-108 E FJR 27-Jan-83 W 273 6 18 6 1092 EIN-110 E MLB 03-Mar-84 C 4 O O O 1209 EIN-110 E LKB 17-Nov-84 W 183 0 12 0 1093 EIN-111 E MLB 06-Mar-84' C 710 51 .0 0 1210 EIN-111 E RY 14-Aug-80 W 3003 4 200 4 1094 EIN-112 E MLB 22-May-84 C 2540 116 O O 1095 EIN-113 E BAR 10-Jan-84 C 40 1 O O 1212 EIN-113 E KK2 19-Aug-82 W 273 12 18 9 1213 EIN-113 E JVW 09-Jun-84 W 273 12 18 9 1096 EIN-114 .E MLB 20-Mar-84 C 40 1 0 0 1097 EIN-115 E MLB 20-Mar-84 C 4 1 O O 1216 EIN-115 E ,T W Z 18-Jan-84 W 243 5 16 5 1098 EIN-116 E MLB 16-Jon-84 C 366 14 0 0 1217 EIN-116 E IFD 18-Jul-81 W 813 8 54 8 1099 EIN-117 E FJR 01-Dec-83 C 4 0 0 0 1210 EIN-117 E DP 03-Feb-53 W 363 1 24 1 1100 EIN-119 E FJR 15-Dec-83 C 48 O O O 1100.1 EIN-119 E HLM 15-Jan-82 W 858 80 57 69 1101 EIN-120 E MLB 16-Dec-83 C 4 0 0 0 1221 EIN-120 E LMB 13-Sep-79 W 453 0 30 0 1102 EIN-121 E FJR_ 21-May-84 C 4 O O O 1103 EIN-122 E TWZ 24-Jan-84 C 59 i O O 1225 EIN-122 E TWZ 23-Jan-84 W 303 1 20-1 1104 EIN-123 E MLB 24-Feb-84 C 94 0 0 0 1226 EIN-123 E DRH O2-Feb-84 W 678 0 45 0 1105 EIN-124 E TWZ 16-Jan-64 C 24 0 0 0 1828 EIN-124 E TWZ 16-Jan-84 W 303 0 20 0 1106 EIN-125 E MLB 16-Jan~84 C 26 1 O O 1230 EIN-125 E MLB 12-Jan-84 W 363 15 24 15 1107 EIN-126 E MLD 20-Mar-84 C 38 6 0 0 1233 EIN-126 E TWZ 03-Aug-84 W 513 41 34 17 1108 EIN-127 E MLB 20-Mar-84 C 30 7 O O 1108.1 EIN-127 E TWZ 03-AuG-84 W 393 41 26 13 1237 EIN-128 E LAP 28-Feb-84 W 123 13 8 8 1109 EIN-129 E MLB 24-Feb-84 C 14 2 O O 1239 EIN-129 E JVW 16-May-84 W 198 10 13 8 .1110 EIN-130 E TWZ 10-Jan-84 C 6 1 O O 1240 EIN-130 E RLM 21-Oct-81 W 168 0 11 0 1241 EIN-130 E KK2 24-Aug-82 W 168 0 11 O l 1111 EIN-131 E DJS 18-Feb-82 C 289 15 0 0 1242 EIN-131 E RLM 16-Feb-82 W 258 0 17 0 1 1243 EIN-131 E FJR 26-Jul-82 W 258 0 17 O 1112 EIN-132 E MLB 24-Feb-84 C 4 2 O O 1244 EIN-132 E MLB 12-Jan-84 W 183 5 12 5 1113 EIN-133 E MLB 24-Feb-84 C 16 2 O O 1245 EIN-133 E KK2 20-Aug-82 W 303 1 20 1 1246 EIN-133 E JVW 09-Jun-84 W 303 1 20 1 1114 EIN-134 E JVW 10-Jan-84 C 2545 3 0 0 1247 EIN-134 E JVW 09-Jun-84 W 153 2 10 2 1248 EIN-134 E KK2 19-Aug-82 W 153 2 10 2 1115 EIN-135 E BAR 10-Jan-84 C 4 2 O O J
k 30-Oct-86 CSR DATADASE VERSION 10/30/86 PAGE d O ITEM R INSP DATE ATT IP DP WI WD () 1251 EIN-135 E KK2 21-Aug-82 W 153 0 12 0 1252 EIN-135 E JVW OS-Jun-84 W 183 0 12 0 1116 EIN-136 E MLB 16-Jan-84 C 4 1 0 0 (1 1253.EIN-136 E JVW 16-May-84 W 228 5 15 5 1117 EIN-137 E MLB 24-Feb-84 C 4 0 0 0 1254 EIN-137 E KK2 13-Jan-82 W 243 9 16 9 (# 1118 EIN-138 E MLB 20-Mar-84 C 76 2 O O N 1255 EIN-138 E TWZ 03-Aug-84 'W 63 16 4 12 1119 EIN-139 E MLB 24-Feb-84 C 4 0 0 0 . {} 1257 EIN-139 E MLB 16-Jan-84 W 93 0 6 0 1258 EIN-139 E MAK 24-May-83 W 93 0 6 0 1120 EIN-140 E MLB 24-Feb-84 C 4 0 0 0- {} 1260 EIN-140 E MLB 16-Jan-84' W 93 0 6 0 1121 EIN-141 E MLB 20-Mar-84 C 4 0 0 0 1262 EIN-141 E MLB 17-Jan-84 W 93 0 6 0 (} 1122 EIN-142 E MLB 20-Mar-84 C 4 0 0 0 1263 EIN-142 E MLB 17-Jan-84 W 93 0 6 0 1123 EIN-143 E MLB 20-Mar-84 C 4 0 0 0 {} 1266 EIN-143 E MLB 19-Jan-84 W 153 0 10 0 1124 EIN-144 E MLB 12-Mar-84 C 40 4 0 0 1868 EIN-144 E MLB 22-Oct-84 W 183 35 12 12 (} 1125 EIN-145 E MLB 24-Feb-84 C 40 1 O O 1270 EIN-145 E JVW 02-Mar-84 W 1083 27 72 19 1126 EIN-146 E KLB 29-Sep-81 C 97 18 O O () 1271 EIN-146 E WW 20-Jul-81 W 723
- 4 48 4
1127 EIN-147 E KLB 29-Sep-81 C 73 3 O O 1272 EIN-147 E WW 20-Jul-81 W 543 10 36 9 {} 1128 EIN-148 E FJR 15-Sep-83 C 74 4 0 0 1273 EIN-148 E-SL 26-Aug-82 W 663 0 44 0 1129 EIN-149 E MK 13-Jul-81 C 61 1 O O {} 1130 EIN-150 E DJS 27-Jan-82 C 9 1 O O 1131 EIN-151 E JLL 24-Jan-84 C 51 O O O 1132 EIN-152 E KLB 16-Jun-82 C 54 6 O O (} 1133.EIN-153 E MLB 04-May-84 C 64 O O O 1134 EIN-154 E FJR 20-Jun-84 C 74 7 0 0 1135 EIN-155 E DJS 08-Mar-82 C 10 1 O O (} 1136 EIN-156 E MLB 21-Nov-83 C 9 0 0 0 1274 EIN-156 E MLB 21-Nov-83 W 93 0 6 0 1137 EIN-157 E JLL 24-Jan-84 C 51 O O O (} 1138 EIN-158' E MLB 30-Mar-84 C 89 10 0 0 1138.1 EIN-158 E JVW 08-May-84 W 573 0 38 0 1139 EIN-159 E DJS 03-Feb-82 C 9 3 0 O () 1140 EIN-160 E FJR 16-Feb-84 C 9 0 0 0 0 0 0 0 ..}}