ML20211G846
| ML20211G846 | |
| Person / Time | |
|---|---|
| Site: | Prairie Island |
| Issue date: | 09/29/1997 |
| From: | Wetzel B NRC (Affiliation Not Assigned) |
| To: | Richard Anderson NORTHERN STATES POWER CO. |
| References | |
| NUDOCS 9710030271 | |
| Download: ML20211G846 (3) | |
Text
g kn at a.
p*
k UNITE 3 STATIES
+
g j
NUCLEAR REGULATCRY CIMMISSIEN o
WASHINGTON D.C. anama aaat
%,*.'..+/
September 29, 1997 fo-28A 11r. Roger 0. Anderson Director Nuclear Energy Engineering Northern States Power Company 414 Nicollet Mall Minneapolis, Minnesota 55401
SUBJECT:
EXEMPTION FROM THE REQUIREMENTS OF 10 CFR 70.24 - PRAIRIE ISLAND NUCLEAR GENERATING PLANT. UNITS 1 AND 2
Dear Mr. Anderson:
It is our understanding that Prairie Island Nuclear Generating Plant. Units 1 and 2. does not meet the requirements of 10 CFR 70.24 and does not have an exemption from this rule.
You may apply for an exemption under the provisions of 10 CFP 70.14.
Your exemption application should verify that Prairie Island Nuclear Generating Plant. Units 1 and 2. meets the following criteria:
1.
Plant procedures do not permit more than one pressurized-water reactor fuel assembly to be in transit between their associated shipping cask and dry storage rack at one time.
2.
The k-effective of the fresh fuel storage racks filled with fuel of the maximum permissible U-235 enrichment and flooded with pure water does not exceed 0.95, at a 95% probability. 95% confidence level.
3.
If optimum moderation of fuel in the fresh fuel storage racks occurs when the fresh fuel storage racks are not flooded, the k-effective corresponding to this optimum moderation does not exceed 0.98, at a 95%
probability. 95% confidence level.
4.
The k-effective of s)ent fuel storage racks filled with fuel of the maximum permissible J-235 enrichment and filled with pure water does not
/
exceed 0.95. at a 95% probability. 95% confidence level.
5.
The quantity of forms of special nuclear material, other than nuclear fuel, that are stored on site in any given area is less than the
{)h, quantity necessary for a critical mass.
6.
Radiation monitors, as required by General Design Criterion 63, are provided in fuel storage and handling areas to detect excessive radiation levels and to initiate appropriate safety actions.
7.
The maximum nominal U-235 enrichment is 5 weight percent.
lllllllllIWi!qllijilllllll IY!$ !".
M
c.
T' Mr, Roger 0. Anderson. Director september 29.11997 For each criterion that you do not meet, please explain why that criterion should_not apply to Prairie Island Nuclear Generating Plant'. Units 1 and 2.
Sincerely.
ORIGINAL SIGNED BY Beth A. Wetzel. Senior Project Manager Project Directorate III-1 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation Docket Nos. 50-282 and 50-306 cc:
See next page
'0ISTRIBUTION:
Docket File PUBLIC PDIII-1 RF EAdensam OGC.-
ACRS JMcCormick-Barger. RIII GWunder DOCUndNT NAME: G:\\WPDOCS\\ PRAIRIE \\PIEXEMP.LTR To receive a copy of this document, indicate in the box C-Copy w/o attachment / enclosure E-Copy with attachment / enclosure N = No copy 0FFICE PM:PD31 E
LA:PD31 E
D:PD31
,a, BWetzel:dbN CJamersonk JHann N NAME DATE 9 /)(, /97 9.//2./d et/ 8 /97-0F ICIAL RECORD COPY
_ Mr. Roger O. Anderson, Director Prairie Island Nuclear Generating l
Northem States Power Company Plant cc:
. J. E. Silberg, Esquire Site Licensing Shaw, Pittman, Potts and Trowbridge Prairie Island Nuclear Generating l
2300 N Street, N. W.
Plant Washington DC 20037 Northem States Power Company 1717 Wakonade Drive East Plant Manager Welch, Minnesota 55089 Prairie Island Nuclear Generating Plant Tribal Council Northem States Power Company Prairie Island Indian Community
.1717 Wakonade Drive East ATTN: Environmental Department Welch, Minnesota 55089 5636 Sturgeon Lake Road Welch, Minnesota 55089 Adonis A. Neblett Assistant Attomey General Office of the Attomey General 455 Minnesota Street Suite 900 St. Paul, Minnesota 55101-2127 U.S. Nuclear Regulatory Commission Resident inspector's Office 1719 Wakonade Drive East Welch, Minnesota 55089-9642 Regional Administrator, Region ill U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, lilinois 60532-4351 Mr. Jeff Cole, Auditor / Treasurer Goodhue County Courthouse Box 408 Red Wing,- Minnesota 55066-0408 Kris Sanda, Commissioner Department of Public Service