h B,

gggna Electric & Gas Company n Na umb 29218 Nuclear Operations SCE&G

" " ~ ' " "

June 6, 1986

', iG e 3. U" Dr. J. Nelson Grace Regional Administrator U. S. Nuclear Regulatory Commission Region II, Suite 2900 101 Marietta Street, N.W.

Atlanta, Georgia 30323

SUBJECT:

Virgil C. Summer i4uclear Station Docket No. 50/395 Operating License No. NPF-12 Special Report (SPR 86-008)

Dear Dr. Grace:

Attached is a Special Report for the Virgil C. Summer Nuclear Station.

This report is submitted pursuant to the requirements of Technical Specification 3.3.3.1. Table 3.3-6, Action Statement 30, Item 2 and Technical Specification 6.9.2.

Should there be any questions, please call us at your convenience.

t

ours,

\\

. A. kau an RMF: DAN / led Attachment pc:

0. W. Dixon, Jr./T. C. Nichols, Jr.

K. E. Nodland E. H. Crews, Jr.

R. A. Stough E. C. Roberts G. O. Percival J. G. Connelly, Jr.

R. L. Prevatte W. A. Williams, Jr.

J. B. Knotts, Jr.

Group Managers S. D. Hogge

0. S. Bradham I&E Washington D. R. Moore Document Management C. A. Price Branch W. T. Frady INPO Records Center C. L. Ligon (NSRC)

ANI Library R. M. Campbell NPCF File 8606190428 860606 PDR ADOCK 05000395 I

q

A b

Dr. J. Nelson Grace SPR 86-008 June 6, 1986 ENCLOSURE 1 EVENT DESCRIPTION On May 25, 1986, RMG-19C, the Noble Gas Effluent Monitor on Main Steam Line "C", was declared inoperable due to spiking above the high radiation setpoint with no detectable radiation present.

ACTION TAKEN The channel was not returned to an operable status in 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />; therefore, the preplanned alternate method of monitoring was implemented.

The cause of the inoperability was determined to be an adjustment problem in the timing circuit of the auxiliary circuit board. The necessary adjustments were made and the channel was returned to service on June 6, 1986.

l l

l

- - -. -, -,.,,