Mr. G:ry R. P;t;rs September'22, 1997 Sit] Vice President Catawha Nucley Station Duke Energy Corporation 4800 Concord Road York, South Carolina ?9745-9635
SUBJECT:
CATAWBA NUCLEAR STATION, UNIT 1 - EVALUATION OF THE SECOND 10-YEAR INTERVAL INSPECTION PROGRAM PLAN, REQUEST FOR RELIEF 96-04 (TAC NO M97465)
Dear Mr. Peterson:
The staff, with technical assistance from its contractor, the Idaho National Engineering and Envhonmental Laboratory (INEEL), has reviewed and evaluated the Information provided by your letter dated December 12,1996, related to the Second 10-Year Interval Inservice inspection Program Plan Request for Relief 96-04 for Catawba Nuclear Station, Unit 1.
Additionalinformation was provided by your letter dated May 5,1997. The staff's evaluation and conclusions are contained in the enclosed Safety Evaluation, with INEEL's Technical j
Letter Report attached.
The staff concludes that the Code coverage requirements are impractical for the subject Safety injection System welds at Catawba Nuclear Station, Unit 1, and that reasonable assurance of the structural integrity has been provided by the examinations that were completed. Therefore, relief is granted pursuant to 10 CFR 50.55a(g)(6)(i). The granting of this relief will not endanger life, property, or the common defense and security, a' d is otherwise in the public interest, giving due consideration to the burden upon the licensee that could result if the reautrements were imposed on the facility.
Sincerely,-
ORIGINAL SIGNED BY L. WHEELER FOR:
Herbert N. Berkow, Director Project Directorate 11-2 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation j
3 Docket No. 50-413 m
mN@
Enclosure:
Safety Evaluation
)/
"8' hh h @@}] gty ko cc w/ encl: See next page ao r':c DISTRIBUTION
$g
$9eshutfiip3.
B.Boger T. Harris (e-mail to TLH3-SE only) 0,4 PUBLIC T. McLellan, O-7 H15 M. Tschiltz, EDO (Rll plants) g GHill (2)
OGC w
ACRS J. Jo;inson, Ril S$o PDil-2 Reading C. Ogle, Ril
.lf lf lll lf ll f DOCUMENT NAME: G:\\ CATAWBA \\ CAT 97465.RR To receive a copy of this document, indicate in the box: "C" = Copy without attachment / enclosure "E" = Copy with attachment /enclosqre "N" = No copy OFFICE PM:PDil-2 LA:PDil[2g OGC,Q6 D:PDR n
NAME PTam:en @ L LBerry y/t) gjWm,um/q HBelWDw F
DATE C/ /(j /97
'-l / /o/97 t y /g /97 9 ly /97
/ /97
/ /97
..j OFFICIAL RECORD COPY ua g
_. -. - _ _... - _. -. _ ~,
..... n. _.. - - -
i
. useg m
i k
p UNITED STATES
~j P;
NUCLEAR REGULATORY COMMISSION p
f WASHINGTON, D.C. 3000H001 September 22, 1997 L Mr. Gary R. Peterson j.
Site Vice President l
Catawba Nuclear Station i
Duke Energy Corporation i
4800 Concord Road York, South Carolina 29745-9635
SUBJECT:
CATAWBA NUCLEAR $TATION, UNIT 1 - EVALUATION OF THE SECOND i
10-YEAR INTERVAL INSPECTION PROGRAM PLAN, REQUEST FOR RELIEF j
96-04 (TAC NO. M97465)
[
Dear Mr. Peterson:
}
The staff, with technical assistance from its contractor, the Idaho National Engineering and i
Environmental Laboratory (INEEL), has aviewed and evaluated the information provided by your letter dated December 12,1996, related to the Second 10-Year Interval inservice -
i inspection Program Plan Request for Relief 96-04 for Catawba Nuclear Station, Unit 1.
i Additional information was provided by your letter dated May 5,1997. The staffs evaluation i
and conclusions are contained in the enclosed Safety Evaluation, with INEEL's Technical Letter Report attached.
i l
The staff concludes that the Code coverage requirements are irrrrectical for the subject j
Safety injection System welds at Catawba Nuclear Station, Unit 1, and that reasonable assurance of the structural integrity has been provided by the examinations that were l
completed. Therefore, relief is granted pursuant to 10 CFR 50.55a(g)(6)(l). The granting of l
this relief will not endanger life, property, or the common defense and security, and is i
otherwise in the public interest, giving due consideration to the burden upon the licensee that could result if the requirements were imposed on the facility.
I Sincerely, M
,/
Hei N. Berkow, irector 4
F roject Directorate 11-2 Division of Reactor Projects - 1/ll Office of Nuclear Reactor Regulation
- [
Docket No. 50-413
Enclosure:
Safety Evaluation
)-
cc w/ encl: See next page
)
1.
M 2
Catawba Nuclear Station I
cc:
l Mr. M. S. Kitlan North Catclina Electric Membership Regulatory Compliance Manager Corporation i
_ Duke Energy Corporation P. O. Box 27306 4800 Concord Road Raleigh, North Carolina 27611
. York, South Carolina 29745 l
Senior Resident inspector Mr. Paul R. Newton 4830 Concord Road Legal Department (PB05E)
York, South Carolina 29745 l-Duka Energy Corporation l
_422 South Church Street Regional Adr.istrator, Reg!on ll j
Charlotte, North Carolina 28242 U. S. Nuclear Regulatory Commission Atlanta Federal Center J. Michael McGarry, Ill, Esquire 61 Forsyth Street, S.W., Suite 23T85 L
Winston and Strawn Atlanta, Georgia 30303 1400 L Street, NW l
Washington, DC 20005 Max Batavia, Chief North Carolina Municipal Power
. Bureau of Radiological Health South Carolina Department of 4'
- Agency Number 1 Health and Environmental Control 1427 Meadowwood Boulevard 2600 Bull Street P. O. Box 29513 Columbia, South Carolina 29201 Raleigh, North Carolina 27626 Mr, G. A. Copp Mr. Peter R. Harden, IV Licensing - EC050 Account Sales Manager Duke Energy Corporation i
Westinghouse Electric Corporation 526 South Church Street Power Systems Field Saies Charlotte, North Carolina 28242-0001 4
(
P. O. Box 7288 i
Chariotte, North Carolina 28241 Saluda River Electric
[
_ County Manager of York County.
Laurens, South Carolina 29360-P. O. Box 929 -
t York County Courthouse L
York, South Carolina 29745 Ms. Karen E. Long L
Assistant Attomey General -
l Richard P. Wilson, Esquire North Carolina Department of Justice Assistant Attomey General-P. O. Box 629 L
South Carolina Attomey General's Raleigh, North Carolina 27602 i
Office P, O. Box 11549 Elaine Wathen, Lead REP Planner i
Columbia, South Carolina 29211 Division of Emergency Management 116 West Jones Street
[
Piedmont Municipal Power Agency Raleigh, North Carolina 27603-1335 121 Village Drive y
Greer, South Carolina 29651 l-
. _... _.. _ _. _ ~.. _ _.
Catawba Nuclear Station cc:
Mr. T. Richard Puryear Owners Group (NCEMC) -
Duke Energy Corporation 4800 Concord Road 4
York, South Carolina 29745 Richard M. Fry, Director.
Division of Radiation Protection North Carolina Department of i
Environment, Health, and Natural Resources 3825 Barrett Drive Raleigh, North Carolina 27609 7721 4
]
i W
1 Y
I 4
--