Fsbruary 20, 1987 Docket No. 82091102 General Electric Company Nuclear Energy Business Operations ATTN: Mr. Noel Shirley, Senior Licensing Engineer Licensing and Consulting Services 175 Curtner Avenue San Jose, California 95125 Gentlemen:

SUBJECT:

QUESTIONS RESULTING FROM DQAVT STAFF REVIEW 0F GE TOPICAL REPORT, NED0-30368, "GE PRODUCT DEPARTMENT QUALIFICATION PROGRAM" The subject report has been reviewed for quality assurance (QA) adequacy by the staff of the Quality Assurance Branch, and for equipment qualification (EQ) technical adequacy by the EQ Section of the Vendor Program Branch of the Division of Quality Assurance, Vendor, and Technical Training Center Programs, Office of Inspection and Enforcement.

This review was the culmination of a process of discussions of our various EQ concerns and your proposed resolutions to them over the past year. QA concerns have been resolved by GE's commitment to QA Topical Report NEB 0-11209 (with exceptions noted). The enclosure to this letter formally documents our EQ con-cerns (as areas requiring clarification) as discussed during the review process.

Upon satisfactory resolution of the issues, the staff intends to issue a safety evaluation report (SER) approving NED0-30368.

Sincerely, original signed by:

Brian K. Grimes, Director Division of Quality Assurance, Vendor, and Technical Training Center Programs Office of Inspection and Enforcement

Enclosure:

Areas Requiring Clarification DISTRUBUTION:

ODMB:IE:09 SAlexander JTaylor JGilray Elmbro BGrimes QAVTReading RBernero, NRR HMiller VPBReading UPotapovs EMerschoff

  • see previous page for concurrence VPB:DQAVT* SC/VPB:DQAVT* ABC/VPB:D0AVT* QAB:DQAVT* SC/QAB:DQAVT* D/DIR:DQAVT*

SAlexander UPotapov EWMerschoff JGilray Elmbro HMiller 1/21/87 1/2 {7, 1/28/87 2/2/87 2/2/87 2/ /87

/NRR

  • Q VT RBernero

.g/87

[go9 i es 2/ /87 8702250207 870220 I

PDR TOPRP EMVGENE O

C PDR

k

.a i

Enclosure General Electric Company Areas Requiring Clarification:

1.

Describe how the topical addresses each applicable provision of the 650.49 rule ard justify neglecting those points you consider not applicable.

(Suggest organizing information keyed to 10 CFR 50.49.)

2.

Describe how the topical report assigns responsibilities for the various functions and processes covered by the program.

3.

Describe how the topical report specifies the format and content of Product Quality Certificates and Certificates of Qualification.

4.

Describe how the topical report commits to industry standards and regulatory guides on equipment qualification such as IEEE Std. 323-74 (Regulatory Guide 1.89, Rev 1),.IEEE Std 323-83, R/G 1.97, etc.

What procedures are there for determining under which set of rules (i.e.,

5.

D0R Guidelines, NUREG 0588, or 10 CFR 50.49) a replacement component must be qualified?

6.

In similarity analyses, what specific technical considerations such as radiation performance, thermal performance, wet electrical performance for various types of equipment will the topical require in considering form, fit, function, process and materials?

For replacement equipment, how will changes in required test environment 7.

severity (e.g., reevaluation for main steam line break conditions) since the original installation be taken into account as well as changes in functional performance requirements due to source term changes or plant modifications?

8.

How will the program ensure that non-identical but qualifiable replacement equipment is suitable for its application under normal operating conditions and how will it address any EQ ramifications of other associated modifications which may be required to make the new component suitable or to make the system compatible?

- -.