ML20211D028

From kanterella
Jump to navigation Jump to search
Advises That Title Will Be Provided on SPDS Iconic Displays to Indicate Wide & Narrow Range,To Correct Human Engineering Deficiency Identified During Audit
ML20211D028
Person / Time
Site: Braidwood  
Issue date: 10/10/1986
From: Miosi A
COMMONWEALTH EDISON CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
2261K, NUDOCS 8610220081
Download: ML20211D028 (1)


Text

,

i Commonwrith Edison C d 72 West Adams Street, Chicago, Illinois

/ KKess Reply to: Post Olfd6cx7bT Chicago, Ilhnois 60690 - 0767 October 10, 1986 Mr. Harold R. Denton U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulatory Washington, DC. 20555

Subject:

Braidwood Station Units 1 and 2 Safety Parameter Display System NRC Docket Nos. 50-456 and 50-457 Reference (a):

October 30, 1985 letter from B.J. Youngblood to D.L.

Farrar

Dear Mr. Denton:

Reference (a) provided an audit report regarding the Byron Safety Parameter Display System (SPDS).

The design of the Byron SPDS is identical to the Braidwood SPDS.

One of the human engineering deficiencies identified during'the Byron audit involved the labeling of the wide and narrow range displays for the SPDS.

To correct this deficiency, a title will be provided on the iconic displays to indicate wide range or narrow range.

This revision to the displays will be completed prior to startup following the first refueling outage for Braidwood Unit 1.

Another item discussed in reference (a) involved the verification and validation review for the SPDS.

A report of this effort for the Braidwood SPDS will be submitted to the NRC prior to startup following the first refueling outage for Braidwood Unit 1.

Please direct any questions regarding this matter to this office.

One signed original and fifteen copies of this letter are provided for NRC review.

Very truly yours, t'

/

j.

W L&

h DO A.

D.

iosi A

Nuclear Licensing Administrator i

cc:j 9c0

/kl J.

Stevens J

2261K go

__