GPU Nuclear Corporation sp y,

ow Je sey 07054 201 263-6500 TELEX 136-482 Writer's Direct Dial Number:

October 3, 1986 5000-86-1050 5211-86-2174 Office of Nuclear Reactor Regulation Attn:

J. F. Stolz, Director PWR Projects Directorate No. 6 Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Mr. Stolz:

Three Mile Island Nuclear Station Unit 1 (TMI-1)

Operating Licensing No. DPR-50 Docket No. 50-289 Regulatory Guide 1.121 Extent of Applicability to OTSG's This letter is a follow-up to prior discussions regarding the applicability of Regulatory Guide 1.121 to Once Through steam Generators (OTSG's).

The once through steam generators employed on B6W designed plants use a vertical vessel with a straight tube fixed at both a lower and upper tubesheet. Characteristic of this design is that any differential thermal expansion between the tubes and the steam generator shell, during either steady state or transient modes of operation, give rise to axial strain in the tubes and hence axial tube loads.

In addition, any pressure differential between the primary and secondary sides can also produce axial loads, although these are always much smaller than the thermal expansion induced loads. The pressure differential on the tubes also produces tube stresses oriented in the circumferential (hoop) direction. All analyses for once through steam generators show that the axial loads are controlling, and where there have been instances of in service cracking, as at TMI, the cracks are circumferential1y oriented as would be expected because of the critical loading (axial) conditions.

In contrast to once through steam generators, recirculation steam generators of the type used in Westinghouse and Combustion Engineering designed plants are vertical shell vessels with a U-tube design in which both inlet and outlet ends of each tube are fixed to a single tubesheet. The tubes are not 8610150033 861003 j

PDR ADOCK 00000289 P

PDR 0j k\\

GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation

J. F. Stolz, Director October 3, 1986 Page Two axially restrained to any significant degree and are free to expand.

Temperature differences between inlet and outlet legs give rise to modest bending moments in the U bends, but no.significant axial loads are produced.

The dominant and controlling tube loads, and therefore stresses, are in the

' hoop direction due to internal pressure. This direction of dominant stress is confirmed in the recirculation steam generators in which observed cracks have been predominantly in the axial direction.

In summary, both recirculation and once through steam generators have pressure induced tube loading which cause circumferential tube stresses, but the once through steam generators uniquely have a dominant axial tube load.

The axial tube load, however, is not force or pressure driven but rather thermally driven and hence, self limited. This latter type load is described in the ASME Section III Code as a secondary type stress. For the purposes of reviewing the applicability of Regulatory Guide 1.121 to once through steam generators, the subsequent discussion uses the nomenclature, definitions and underlying methodology contained in the ASME Section III Code.

ASME Code - Primary and Secondary Stresses The ASME Boiler and Pressure Vessel Code,Section III, Subsection NB, provides definitions for the categorization of loads and stresses into primary, secondary and peak stress components. Code allowable stresses are dependent upon the load effects considered (i.e., primary stresses alone or in combination with secondary stresses) and the frequency of the stress occurrence.

A thermal stress is classified as a secondary stress and not classified as a primary stress, (NB-3213.8, NB-3213.9). A,econdtry_ stress is a normal or shear stress developed by the constraint of adjace.nt material or by self constraint of the structure (i.e., the thermal induced axial tube load in OTSG's). A basic characteristic of a secondary stress is that it is self limiting. Local yielding and/or minor strsin can relax the loads which originally caused the stress to occur, and failure f rom one application of 1such secondary stresses is not expected. Thermal insluced stress (secondary stress) is developed in a solid body (i.e., the composite OTSG shell and fixed. tubes) whenever a volume of material is prevented from assuming the size and shape that it freely should take under a change 'in temperature.

General thermal stress is associated with Jistortion of the structure in which it occurs (NB-3213.13).

These Code definitions are applicable to pressure vessels (i.e., UTSG) and to penetrations.

In the application of Regulatory Guide 1.121 to OTSG's, it is not proposed to simply disregard therral stress as is done in Section XI

n i

p e

(J.F.Stolz, Director October 3, 1986 Page Three of the Code where, for ductile materials only, primary stresse's are considered when performing flow stability evaluations. Rather,.we should extract the physical understanding that is the basis for Code Conceptually, if a less stiff part of a structure (i.e., tube) guidance.

is displaced i

to its yield strength by a more massive part of a structure (i.e., shell),

solely because of there being a temperature difference between them, an increase in stress in the less stiff structure much beyond the yield strength will not occur because strain deformation of the less stiff member-will bring it into size conformance with the more massive member. With reasonable ductility of materials (metals) usually encountered, parting or l'

other mechanical failure of the less stiff member will not occur.

i Regulatory Guide 1.121 Applicability

_In assessing the integrity of steam generator tubes, with or without flaws, Regulatory Guide 1.121 makes use of margins to be applied to calculated tube loads to assure sufficient conservatism exists in comparing predicted to l

required tube capacity. These margins are based upon factoring normal loads by 3 and accident loads by 1.428. For recirculation steam generators, these factors have been applied to pressure effects (a primary load) in assessing repair limits. Since pressure effects are the predominant and critical recirculation generator load, this application of load increase by 3 or 1.428 provides the necessary margin.

For the case of OTSG's, application of Regulatory Guide 1.121 factors is l

equally appropriate for primary stresses as for recirculation generators.

l We show the results of this factor application to OTSG primary stresses in Table 1, attached. Code allowables are never exceeded. Since OTSG's have a significant axial tube load (stress) which is not a primary but rather a secondary stress, a treatment of this secondary stress in a manner consistent with the underlying development of the Code would not involve application of safety factors to these secondary stresses. These secondary stresses are more significant in considering fatigue resistance. A Code consistent, and conservative approach is to apply the Regulatory Guide 1.121 margins to strain and determine the new load in recognition of the load redistribution that occurs. This redefined load could then be used in assessing tube failure and the impact of tube flaws.

Stannary In summary, we believe Regulatory Guide 1.121 is a technically sound l

approach when applied to evaluating steam generators with predominant primary stresses.

In the case of once through steam generators, meaningful strain-limited or secondary stresses exist.

In this latter case, we conclude

A e

J. F. Stolz, Director October 3, 1986 Page Four that Regulatory Guide 1.121 is not directly applicable in cases where significant secondary stress exists. We believe a proper approach is to put margin on total strain and demonstrate that the component has the capacity to resist the resulting stress and not fail. This approach will ensure a high reliability of tube integrity under all normal and accident loading conditions, a

'yt m1y yours, T2 ih R. F. Wi son Vice President Technical Functions

/ama Attachment cc:

R. Conte l

J. Thoma l

e

1 f

I TABLE 1 OTSG TUBING DESIGN BASIS l

AXIAL STRESSES (based on unflawed tube)

Maximum Normal Operating Stress j

Design Basis (DB) 3XDB Sect. III Allow.

II) 6,809 20,427 23,000 Mechanical (Primary)

Mechanical + Thermal (2) 17,571 52,713 69,000 (Primary + Secondary)

Maximum Accident Stress I

Design Basis (DB) 1.42808 Sect. III Allow.

Mechanical (3) 8,920 12,666 27,600 (Primary)

Mechanical + Thermal (3) 49,841 No Limit; Evaluation (Primary + Secondary) not required for secondary stresses i

(1) O to 15% power change I

i (2) Cooldown from 15% power (3) Main steam line break b

I

e GENERAL REFERENCES 1.

ASME Code - Section III 2.

Lang, J., F., et al, Analysis of Leak-Before Break for Steam Generator Tubes, Proceedings of Third International Topical Meeting on Reactor Thermal Hydraulics, Vol. 2, Sessions 13 -21, C.:Chong and G. Brown, Eds, Newport, Rhode Island, October 15-18, 1985.

3.

Griesbach, T., et al, Analysis Methods for Evaluating Leak-Before-Breaks in U-Tube Steam Generators, Ibid.

4.

Babcock & Wilcox Topical Report No. BAW-10146, Determination of Minimum Required Tube Wall Thickness for 177-FA Once-Through Steam Generators, Oct.1980.

s