Proposed Tech Spec 3.1.1.3,reflecting Footnote for Mode 1 Applicability That Refs Special Test Exception 3.10.2 for Moderator Temp Coefficient
ML20210U938
Person / Time
Site: Waterford 
Issue date: 02/12/1987
From:
LOUISIANA POWER & LIGHT CO.
To:
Shared Package
ML20210U912 List:
References
NUDOCS 8702180640
Download: ML20210U938 (4)


Text

w NPF-38-58 ATTACHMENT B 0702180640 870212 PDR ADOCK 05000392 P

PDR NS20604

~

. REACTIVITY CONTROL SYSTEMS MODERATOR TEMPERATURE COEFFICIENT LIMITING CONDITION FOR OPERATION 3.1.1.3 -The moderator temperature coefficient (MTC) shall be:

-4 a.

Less positive than 0.5 x 10 delta k/k/*F whenever THERMAL POWER is < 70% RATED THERMAL POWER, and

-4 b.

Less positive than 0.0 x 10 delta k/k/*F whenever THERMAL POWER is > 70% RATED THERMAL POWER, and

~4 c.

Less negative than -3.3 x 10 delta k/k/*F at all levels of thermal power.

APPLICABILITY: MODES 1 and 2*#

ACTION:

1 With the moderator temperature coefficient outside any one of the above limits, be in at least HOT STANDBY w.ithin 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.1.1.3.1 The MTC shall be determined to be within its limits by confirmatory measurements. MTC measured values shall be extrapolated and/or compensated to permit direct comparison with the above limits.

4.1.1.3.2 The MTC shall be determined at the following frequencies and THERMAL POWER conditions during each fuel cycle:

Prior to initial operation above 5% of RATED THERMAL POWER, after a.

each fuel loading.

b.

At greater than 15% of RATED THERMAL POWER, prior to reaching 40 EEPD core burnup.

At any THERMAL POWER, within 7 EFPD of reaching two-thirds o'f c.

expected core burnup.

i "With K,ff greater than or equal to 1.0.

  1. See Special Test Exception 3.10.2.

i WATERFORD - UNIT 3 3/4 1-4 AMEN 0 MENT NO. 13

,i

NPF-38-58 ATTACHMENT C l

l NS20604

=

a REACTIVITY CONTROL SYSTEMS o

MODERATOR TEMPERATURE COEFFICIENT LIMITING CONDITION FOR OPERATION 3.1.1.3 The moderator temperature coefficient (MTC) shall be:

~4 a.

Less positive than 0.5 x 10 delta VV'F whenever THERMAL POWER is i 70% RATED THERMAL POWER, and

~4 b.

Less positive than 0.0 x 10 delta UV'F whenever THERMAL POWER is > 70% RATED THERMAL POWER, and

-4 c.

Less negative than -3.3 x 10 delta UV'F at all levels of thermal power.

APPLICABILITY: MODES 1 and 2*#

)

ACTION:

With the moderator temperature coefficient outside any one of the above limits, be in at least HOT STANDBY w.ithin 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

5 SURVEILLANCE REQUIREMENTS 4.1.1.3.1 The MTC shall be determined to be within its limits by confirmatory measurements. MTC measured values shall be extrapolated and/or compensated to permit direct comparison with the above limits.

4.1.1.3.2 The MTC shall be determined at the following frequencies and THERMAL POWER conditions during each fuel cycle:

a.

Prior to initial operation above 5% of RATED THERMAL POWER, after each fuel loading.

b.

At greater than 15% of RATED THERMAL POWER, prior to reaching 40 EEPD core burnup.

c.

At any THERMAL POWER, within 7 EFPD of reaching two-thirds of expected core burnup.

"With K,ff greater than or equal to 1.0.

  1. See Special Test Exception 3.10.2.

WATERFORD - UNIT 3 3/4 1-4 AMENDMENT NO. 13 6