MONTHYEARML20212A2471999-09-15015 September 1999 Summary of 990902 Meeting with Westinghouse in Rockville,Md Re Changes That W Plan to Make in Rev 3 of AP600 Design Control Document (Dcd).List of Attendees & Handouts Encl ML20206S6831998-09-0101 September 1998 Summary of 453rd ACRS Meeting on 980603-05 in Rockville,Md Re Appropriate Action on Items Listed in Attached Agenda ML20206S3721998-07-29029 July 1998 Summary of 980707 ACRS Advanced Reactor Designs Subcommittee Meeting in Rockville,Md Re Info on AP600 Test & Analysis Program & Responses to ACRS Questions Asked During Previous Meetings ML20206S3501998-06-26026 June 1998 Summary of 980617-18 ACRS Advanced Reactor Designs Subcommittee Meeting in Rockville,Md Re Review of Advance FSER Chapters 4,5,7,8,11,13 & 18,level 1 AP600 Pra,Itaac & Associated ACRS Open Questions ML20206S3361998-06-22022 June 1998 Summary of 980611-12 Open ACRS Thermal Hydraulic & Severe Accident Phenomena Subcommittee Meeting in Rockville,Md Re Continuance of Review of Results of W Test & Analysis Program in Support of AP600 Design Certification ML20249A7191998-06-16016 June 1998 Summary of 980611 Appeal Meeting W/Westinghouse in Rockville,Md Re Appeal of NRC Position on Use of AP600 Bldg Figures in Section 3.3 of AP600 Tier 1 Matl.Attendance List, handouts,marked-up Page 3.3-1 & Note 2 Encl ML20206S5671998-05-30030 May 1998 Summary of ACRS Advanced Reactor Designs Subcommittee 980513-15 Meeting in Rockville,Md Re Review of AP600 Standard SAR & Associated Advanced FSER Chapters 3,6,14,16 & 17 ML20206S2521998-05-14014 May 1998 Summary of 451st ACRS Meeting on 980402-04 in Rockville,Md Re Items Listed in Attached Agenda ML20217K6281998-04-28028 April 1998 Summary of 980416 Meeting W/Westinghouse in Rockville,Md to Discuss AP600 TS Issues.List of Participants & Handouts & Markups Provided by Licensee During Meeting,Encl ML20217P8441998-04-0707 April 1998 Summary of 980212 Meeting W/Westinghouse in Rockville,Md to Continue Discussion on Level 1 Probabilistic Risk Assessment Insights.Addl Telcon Was Held on 980217,due to Unresolved Issues During Meeting.List of Attendees Encl ML20217J9321998-04-0303 April 1998 Summary of 980211 Meeting W/W in Rockville,Md Re Safety Classification of Coatings Inside Containment & on Exterior of Containment Shell.List of Attendees & Handout Encl ML20216G6071998-03-12012 March 1998 Summary of 980211 Meeting W/Westinghouse in Rockville,Md Re Status of Open Issues Resulting from Design Certification Review of AP600.List of Attendess Encl ML20216B1221998-03-0606 March 1998 Summary of 980122 Meeting W/Westinghouse in Rockville,Md Re Status of Open Issues Resulting from Design Certification Review of AP600.List of Attendees Encl ML20216G1471998-03-0606 March 1998 Summary of 980224 Meeting W/Westinghouse Electric Co to Resolve Issues Re AP600 Fire Protection Design ML20197B9091998-03-0606 March 1998 Summary of 971218 Meeting W/Westinghouse in Rockville,Md Re Open Issues Remaining on Analyses of Radiological Consequences of Design Basis Accidents for AP600 Design. List of Attendees & Handouts Provided at Meeting Encl ML20217A8561998-03-0505 March 1998 Summary of ACRS 448th Meeting on 980205-07 Re Several Matters & Completed Listed Rept & Ltr.Committee Authorized Larkins,Executive Director,To Transmit Memoranda Listed ML20206S2651998-02-23023 February 1998 Summary of 980203-04 ACRS Subcommittee on Advanced Reactor Designs Open Meeting in Rockville,Md Re Review of Chapters 1,4,5,7,8,11,13 & 18 of AP600 Ssar & AP600 Test & Analysis Program ML20203H8691998-02-19019 February 1998 Summary of 980211 Meeting W/W in Rockville,Md Re W Opportunity to Respond to NRC Insp Rept 99900404/97-02,dtd 980128.List of Attendees & Meeting Handouts Encl ML20203A8991998-02-11011 February 1998 Summary of 980120 & 21 Meeting W/Westinghouse to Discuss AP600 Structural Calculations to Resolve FSER Open Items. List of Participants & Handouts Encl ML20198Q1471998-01-13013 January 1998 Summary of 971104 Meeting W/Westinghouse in Rockville,Md Re AP600 Nuclear Island Basemat Design,Configuration of Shear Stirrups & Shear Capacity of Deep Slabs.List of Attendees & Handouts Encl ML20198H5621998-01-0707 January 1998 Summary of 971218 Meeting W/Westinghouse in Rockville,Md to Discuss Design Certification Schedule for AP600 Review ML20198A1861997-12-18018 December 1997 Summary of 971117 Meeting W/Westinghouse in Rockville,Md Re Design Certification Schedule for AP600.List of Attendees & Handouts Provided During Meeting Encl ML20199B1211997-11-0606 November 1997 Summary of 971029 Meeting W/Westinghouse in Rockville,Md to Discuss Problems & Progress Affecting AP600 Review Schedule. List of Attendees Encl ML20198R6601997-10-30030 October 1997 Summary of 971109 Telcon W/Westinghouse to Discuss RAI Responses Related to TS & Sys Level Testing ML20198R9261997-10-30030 October 1997 Summary of 971009 Meeting W/Westinghouse in Rockville,Md Re Design Certification Schedule for AP600.List of Attendees & Handouts Encl ML20212B7491997-10-20020 October 1997 Summary of 971007 Meeting W/Westinghouse in Rockville,Md Re AP600 General Design Features & Safety Philosophy.List of Attendees & Presentation Slides Provided by Westinghouse Encl ML20217K7951997-10-17017 October 1997 Summary of 970929 Meeting W/W to Discuss Fire Protection Issues for AP600 Design.List of Attendees & Handouts Provided by Licensee Encl ML20211L2751997-10-0707 October 1997 Summary of 970923 Meeting W/Westinghouse in Monroeville,Pa Re Status of Completion of AP600 Design Documentation in Several Review Areas in Order to Support Final QA Insp ML20217E8141997-10-0202 October 1997 Summary of 970925 Meeting W/Westinghouse in Rockville,Md Re First Interdisciplinary Review of ITAAC for AP600 Design. Agenda & Listed of Attendees Encl ML20217E9961997-10-0202 October 1997 Summary of 970911 Meeting W/Westinghouse Electric Corp Re Fire Protection Issues for AP600 Design ML20211H9691997-09-30030 September 1997 Summary of 970804-15 Meeting W/W in Rockville,Md to Review Structural Design of Nuclear Island Structures.List of Participants & Agenda for 2 Wk Review Encl ML20211G2681997-09-23023 September 1997 Summary of 970910 Meeting W/Westinghouse in Rockville,Md Re Design Certification Schedule for AP600.List of Attendees & Handouts Encl ML20211C4891997-09-18018 September 1997 Summary of 970717,0805,0905 & 0911 Telcons Between Westinghouse & Staff Members Re Severe Accident & PRA Issues.List of Participants,Topics for Discussion & Disposition for Topics Encl ML20198H5421997-09-11011 September 1997 Summary of 970828 Telcon W/W Re Proposed Design Changes to AP600 MCR Habitability Sys.List of Participants & Preliminary Sketch of Modified Design & Associated Temperature Response Encl ML20210Q7641997-08-28028 August 1997 Summary of 970826 Telcon W/Westinghouse Re AP600 Emergency Response Guidelines.Summary of Actions from Telcon Listed. List of Telcon Participants Encl ML20210Q1221997-08-22022 August 1997 Summary of 970807 Meeting W/Westinghouse Re Proposed Containment Spray Design for AP600 Design.List of Attendees & Slides Encl ML20210Q7561997-08-22022 August 1997 Summary of 970808 Meeting W/Westinghouse Electric Corp in Monroeville,Pa Re Fire Protection Issues for AP600 Design. List of Attendees,Agenda & Slides Presented by Westinghouse Encl ML20210M7361997-08-19019 August 1997 Summary of 970807 Meeting W/W in Rockville,Maryland Re AP600 MCR Habitability Sys Operational Parameters of Air Flow rates,CO2 Levels,Temperature & Humidity Needed to Establish Personnel Habitability of Design ML20217K6741997-08-12012 August 1997 Summary of 970806 Safeguards Meeting W/Westinghouse to Discuss Safeguards Issues on AP600 Design ML20217G8621997-07-31031 July 1997 Summary of 970708 Meeting W/Westinghouse in Rockville,Md to Discuss Design Certification Issues for AP600.List of Attendees & Handouts Encl ML20151J6501997-07-31031 July 1997 Summary of 970723 Telcon W/W to Discuss 970709 Submittal of NSD-NRC-97-5227 Re Site Parameters.List of Attendees & Comments Prior to Telcon Encl ML20151J6081997-07-31031 July 1997 Summary of 970709 Meeting W/Westinghouse in Rockville,Md Re Discuss Design Certification Issues for AP600.List of Attendees & Handouts Encl ML20141D4321997-06-23023 June 1997 Summary of 970425 Meeting W/Westinghouse in Rockville,Md Re Resolution of Open Items for Reactor Sys AP600 Pirt/Scaling Closure rept,(WCAP-14727).List of Attendees,Meeting Agenda & Westinghouse Meeting Presentation Matl Encl ML20141C4971997-06-23023 June 1997 Summary of 970609 Meeting W/W in Rockville,Md to Discuss Open Item Tracking Sys Issues Involving Instrumentation & Control Section of AP600 TSs Section 3.3.Highlights from Meeting & Summary of Results Listed ML20149J2181997-06-16016 June 1997 Summary of 970416-18 Meeting W/Westinghouse in Monroeville, MD Re AP600 Piping Design Analysis.Meeting Attendees Listed in Encl 1 ML20140G4541997-06-12012 June 1997 Summary of 970520 Meeting W/Westinghouse in Monroeville,Pa Re AP600 Containment Hydrogen Control Sys.List of Attendees & Action Items Identified During Meeting Encl ML20140B4251997-06-0404 June 1997 Summary of 970519 Meeting W/Westinghouse Re AP600 Fire Protection Issues ML20141G5421997-05-15015 May 1997 Summary of 970422 Meeting W/W in Rockville,Md to Discuss Design Certification Issues for AP600.List of Meeting Attendees Encl ML20141G3801997-05-15015 May 1997 Summary of 970414-18 Meeting W/W in Monroeville,Pa to Discuss W Ssar Sections 3.7 & 3.8 Re Design & Analysis of Structural Modules,Review Structural Design Calculations & Resolve Remaining Dser Open Items.List of Attendees Encl ML20141D0361997-05-15015 May 1997 Summary of 970513 Meeting W/W to Discuss Safeguards Issues on AP600 Design.List of Attendees Encl 1999-09-15
[Table view] Category:MEETING SUMMARIES-INTERNAL (NON-TRANSCRIPT)
MONTHYEARML20212A2471999-09-15015 September 1999 Summary of 990902 Meeting with Westinghouse in Rockville,Md Re Changes That W Plan to Make in Rev 3 of AP600 Design Control Document (Dcd).List of Attendees & Handouts Encl ML20206S6831998-09-0101 September 1998 Summary of 453rd ACRS Meeting on 980603-05 in Rockville,Md Re Appropriate Action on Items Listed in Attached Agenda ML20206S3721998-07-29029 July 1998 Summary of 980707 ACRS Advanced Reactor Designs Subcommittee Meeting in Rockville,Md Re Info on AP600 Test & Analysis Program & Responses to ACRS Questions Asked During Previous Meetings ML20206S3501998-06-26026 June 1998 Summary of 980617-18 ACRS Advanced Reactor Designs Subcommittee Meeting in Rockville,Md Re Review of Advance FSER Chapters 4,5,7,8,11,13 & 18,level 1 AP600 Pra,Itaac & Associated ACRS Open Questions ML20206S3361998-06-22022 June 1998 Summary of 980611-12 Open ACRS Thermal Hydraulic & Severe Accident Phenomena Subcommittee Meeting in Rockville,Md Re Continuance of Review of Results of W Test & Analysis Program in Support of AP600 Design Certification ML20249A7191998-06-16016 June 1998 Summary of 980611 Appeal Meeting W/Westinghouse in Rockville,Md Re Appeal of NRC Position on Use of AP600 Bldg Figures in Section 3.3 of AP600 Tier 1 Matl.Attendance List, handouts,marked-up Page 3.3-1 & Note 2 Encl ML20206S5671998-05-30030 May 1998 Summary of ACRS Advanced Reactor Designs Subcommittee 980513-15 Meeting in Rockville,Md Re Review of AP600 Standard SAR & Associated Advanced FSER Chapters 3,6,14,16 & 17 ML20206S2521998-05-14014 May 1998 Summary of 451st ACRS Meeting on 980402-04 in Rockville,Md Re Items Listed in Attached Agenda ML20217K6281998-04-28028 April 1998 Summary of 980416 Meeting W/Westinghouse in Rockville,Md to Discuss AP600 TS Issues.List of Participants & Handouts & Markups Provided by Licensee During Meeting,Encl ML20217P8441998-04-0707 April 1998 Summary of 980212 Meeting W/Westinghouse in Rockville,Md to Continue Discussion on Level 1 Probabilistic Risk Assessment Insights.Addl Telcon Was Held on 980217,due to Unresolved Issues During Meeting.List of Attendees Encl ML20217J9321998-04-0303 April 1998 Summary of 980211 Meeting W/W in Rockville,Md Re Safety Classification of Coatings Inside Containment & on Exterior of Containment Shell.List of Attendees & Handout Encl ML20216G6071998-03-12012 March 1998 Summary of 980211 Meeting W/Westinghouse in Rockville,Md Re Status of Open Issues Resulting from Design Certification Review of AP600.List of Attendess Encl ML20216B1221998-03-0606 March 1998 Summary of 980122 Meeting W/Westinghouse in Rockville,Md Re Status of Open Issues Resulting from Design Certification Review of AP600.List of Attendees Encl ML20216G1471998-03-0606 March 1998 Summary of 980224 Meeting W/Westinghouse Electric Co to Resolve Issues Re AP600 Fire Protection Design ML20197B9091998-03-0606 March 1998 Summary of 971218 Meeting W/Westinghouse in Rockville,Md Re Open Issues Remaining on Analyses of Radiological Consequences of Design Basis Accidents for AP600 Design. List of Attendees & Handouts Provided at Meeting Encl ML20217A8561998-03-0505 March 1998 Summary of ACRS 448th Meeting on 980205-07 Re Several Matters & Completed Listed Rept & Ltr.Committee Authorized Larkins,Executive Director,To Transmit Memoranda Listed ML20206S2651998-02-23023 February 1998 Summary of 980203-04 ACRS Subcommittee on Advanced Reactor Designs Open Meeting in Rockville,Md Re Review of Chapters 1,4,5,7,8,11,13 & 18 of AP600 Ssar & AP600 Test & Analysis Program ML20203H8691998-02-19019 February 1998 Summary of 980211 Meeting W/W in Rockville,Md Re W Opportunity to Respond to NRC Insp Rept 99900404/97-02,dtd 980128.List of Attendees & Meeting Handouts Encl ML20203A8991998-02-11011 February 1998 Summary of 980120 & 21 Meeting W/Westinghouse to Discuss AP600 Structural Calculations to Resolve FSER Open Items. List of Participants & Handouts Encl ML20198Q1471998-01-13013 January 1998 Summary of 971104 Meeting W/Westinghouse in Rockville,Md Re AP600 Nuclear Island Basemat Design,Configuration of Shear Stirrups & Shear Capacity of Deep Slabs.List of Attendees & Handouts Encl ML20198H5621998-01-0707 January 1998 Summary of 971218 Meeting W/Westinghouse in Rockville,Md to Discuss Design Certification Schedule for AP600 Review ML20198A1861997-12-18018 December 1997 Summary of 971117 Meeting W/Westinghouse in Rockville,Md Re Design Certification Schedule for AP600.List of Attendees & Handouts Provided During Meeting Encl ML20199B1211997-11-0606 November 1997 Summary of 971029 Meeting W/Westinghouse in Rockville,Md to Discuss Problems & Progress Affecting AP600 Review Schedule. List of Attendees Encl ML20198R6601997-10-30030 October 1997 Summary of 971109 Telcon W/Westinghouse to Discuss RAI Responses Related to TS & Sys Level Testing ML20198R9261997-10-30030 October 1997 Summary of 971009 Meeting W/Westinghouse in Rockville,Md Re Design Certification Schedule for AP600.List of Attendees & Handouts Encl ML20212B7491997-10-20020 October 1997 Summary of 971007 Meeting W/Westinghouse in Rockville,Md Re AP600 General Design Features & Safety Philosophy.List of Attendees & Presentation Slides Provided by Westinghouse Encl ML20217K7951997-10-17017 October 1997 Summary of 970929 Meeting W/W to Discuss Fire Protection Issues for AP600 Design.List of Attendees & Handouts Provided by Licensee Encl ML20211L2751997-10-0707 October 1997 Summary of 970923 Meeting W/Westinghouse in Monroeville,Pa Re Status of Completion of AP600 Design Documentation in Several Review Areas in Order to Support Final QA Insp ML20217E8141997-10-0202 October 1997 Summary of 970925 Meeting W/Westinghouse in Rockville,Md Re First Interdisciplinary Review of ITAAC for AP600 Design. Agenda & Listed of Attendees Encl ML20217E9961997-10-0202 October 1997 Summary of 970911 Meeting W/Westinghouse Electric Corp Re Fire Protection Issues for AP600 Design ML20211H9691997-09-30030 September 1997 Summary of 970804-15 Meeting W/W in Rockville,Md to Review Structural Design of Nuclear Island Structures.List of Participants & Agenda for 2 Wk Review Encl ML20211G2681997-09-23023 September 1997 Summary of 970910 Meeting W/Westinghouse in Rockville,Md Re Design Certification Schedule for AP600.List of Attendees & Handouts Encl ML20211C4891997-09-18018 September 1997 Summary of 970717,0805,0905 & 0911 Telcons Between Westinghouse & Staff Members Re Severe Accident & PRA Issues.List of Participants,Topics for Discussion & Disposition for Topics Encl ML20198H5421997-09-11011 September 1997 Summary of 970828 Telcon W/W Re Proposed Design Changes to AP600 MCR Habitability Sys.List of Participants & Preliminary Sketch of Modified Design & Associated Temperature Response Encl ML20210Q7641997-08-28028 August 1997 Summary of 970826 Telcon W/Westinghouse Re AP600 Emergency Response Guidelines.Summary of Actions from Telcon Listed. List of Telcon Participants Encl ML20210Q1221997-08-22022 August 1997 Summary of 970807 Meeting W/Westinghouse Re Proposed Containment Spray Design for AP600 Design.List of Attendees & Slides Encl ML20210Q7561997-08-22022 August 1997 Summary of 970808 Meeting W/Westinghouse Electric Corp in Monroeville,Pa Re Fire Protection Issues for AP600 Design. List of Attendees,Agenda & Slides Presented by Westinghouse Encl ML20210M7361997-08-19019 August 1997 Summary of 970807 Meeting W/W in Rockville,Maryland Re AP600 MCR Habitability Sys Operational Parameters of Air Flow rates,CO2 Levels,Temperature & Humidity Needed to Establish Personnel Habitability of Design ML20217K6741997-08-12012 August 1997 Summary of 970806 Safeguards Meeting W/Westinghouse to Discuss Safeguards Issues on AP600 Design ML20217G8621997-07-31031 July 1997 Summary of 970708 Meeting W/Westinghouse in Rockville,Md to Discuss Design Certification Issues for AP600.List of Attendees & Handouts Encl ML20151J6501997-07-31031 July 1997 Summary of 970723 Telcon W/W to Discuss 970709 Submittal of NSD-NRC-97-5227 Re Site Parameters.List of Attendees & Comments Prior to Telcon Encl ML20151J6081997-07-31031 July 1997 Summary of 970709 Meeting W/Westinghouse in Rockville,Md Re Discuss Design Certification Issues for AP600.List of Attendees & Handouts Encl ML20141D4321997-06-23023 June 1997 Summary of 970425 Meeting W/Westinghouse in Rockville,Md Re Resolution of Open Items for Reactor Sys AP600 Pirt/Scaling Closure rept,(WCAP-14727).List of Attendees,Meeting Agenda & Westinghouse Meeting Presentation Matl Encl ML20141C4971997-06-23023 June 1997 Summary of 970609 Meeting W/W in Rockville,Md to Discuss Open Item Tracking Sys Issues Involving Instrumentation & Control Section of AP600 TSs Section 3.3.Highlights from Meeting & Summary of Results Listed ML20149J2181997-06-16016 June 1997 Summary of 970416-18 Meeting W/Westinghouse in Monroeville, MD Re AP600 Piping Design Analysis.Meeting Attendees Listed in Encl 1 ML20140G4541997-06-12012 June 1997 Summary of 970520 Meeting W/Westinghouse in Monroeville,Pa Re AP600 Containment Hydrogen Control Sys.List of Attendees & Action Items Identified During Meeting Encl ML20140B4251997-06-0404 June 1997 Summary of 970519 Meeting W/Westinghouse Re AP600 Fire Protection Issues ML20141G5421997-05-15015 May 1997 Summary of 970422 Meeting W/W in Rockville,Md to Discuss Design Certification Issues for AP600.List of Meeting Attendees Encl ML20141G3801997-05-15015 May 1997 Summary of 970414-18 Meeting W/W in Monroeville,Pa to Discuss W Ssar Sections 3.7 & 3.8 Re Design & Analysis of Structural Modules,Review Structural Design Calculations & Resolve Remaining Dser Open Items.List of Attendees Encl ML20141D0361997-05-15015 May 1997 Summary of 970513 Meeting W/W to Discuss Safeguards Issues on AP600 Design.List of Attendees Encl 1999-09-15
[Table view] |
Text
_ _ - -- - - - - - - -
arg t UNITED STATES gf ' )
s (- ,j- NUCLEAR REGULATORY COMMISSION
% g WASHINGTON, D.C. 3068H001
'% # August 28, 1997 APPLICANT: Westinghouse Electric Corporation PROJECT: AP600
SUBJECT:
SUMMARY
OF TELEPHONE CONFERENCE TO DISCUSS WESTINGHOUSE RESPONSES TO AP600 EMERGENCY RESPONSE GUIDELINE COMMENTS On August 26, 1997, the Nuclear Regulatory Comission (NRC) staff, an NRC contractor, and Westinghouse (see Attachment) conducted a telephone conference-(telecon) concerning the AP600 Emergency Response Guidelines (ERGS). NRC
- coments on the ERGS were provided to Westinghouse via NRC letters dated February 6, March 13, and April 9,1997. Westinghouse subsequently revised the ERGS and the Adverse System Interactions (ASI) evaluation report to address the NRC coments. The purpose of the telecon was to discuss how the NRC coments were addressed in the revised ERGS.
The following is a sumary of actions from the telecon:
Westinghouse agreed to formally document its responses to the three NRC ERG coment letters.
Westinghouse will revise the introduction to the ERG background document to discuss the need for the E0P writers to identify the continuous action steps. Westinghouse will provide some examples of ERG steps which are subject to continuous action.
Westinghouse will revise the introduction to the ERG background document to explain what is meant by the statement " Evaluate Long Term Plant h
Status" which appears in a number of ERGS. -This discussion will include g
the COL applicants development of an accident management plan and its relationship to the ERGS /EOPs. 3 Westinghouse will place a statement in the introduction to the ERG background document which directs the E0P writer to consider the insights identified in Chapter 3 of the ASI report, WCAP-14477.
Westinghouse will include a discussion in its response to coment #1 of the NRC February 6,1997, letter which will address that adverse interactions from the pressurizer spray and reactor head vent were reviewed but that no interactions were found.
Westinghouse will revise ERG procedures-AES-0.1 and AES-0.2 as comented in its response to coment #7 of the February 6,1997, NRC letter.
Westinghouse will revise its response to coment #8 of the NRC Febru-ary 6, 1997, letter by noting that the ERG background document discusses the role of automatic trip of the pressurizer heaters.
I2 iN llIlllllkll), l, l oy.f77 9709020142 970828 8 PDR ADOCK 05200003 A PDR
=; .
- =
= August 28, 1997 Westinghou'se'will revise information in the background document for AES-1.2, ste) 15, to be-consistent ^with the ASI evaluation report concerning t te isolation of-accumulators to )revent nitrogen injection cinto the RCS. Westinghouse will also make tiis.rev.ision in other ERG step backgrounds-where appropriate.
]
Westinghouse will clarify its res)onse to comment #18 of NRC letter dated April 9. 1997, to explain t1at there is no backup for the accumu-i lators and none needed when they are isolated in step 25 of AE-3.
Westinghouse will issue an errata on the ASI evaluation report, WCAP-14477, Section 3.2, Subsection 2.2.1, which clarifies that ERGS permit restart of the RCPs after reset on an SI signal - and do not allow the operator to block the CMT actuation, original signed by:
William C. Huffman, Project Manager Standardization Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket-No.-52-003-
Attachment:
- As stated cc-w/att: .See next page DISTRIBUTION w/ attachment: .
Docket File PDST R/F TKenyon PUBLIC- BHuffman- JSebrosky DJackson-DISTRIBUTION w/o attachment:
.Scollins/FMiraglia, 0-12 G18 BSheron, 0-12 G18 JRoe DMatthews TQuay WDean,'0-5 E23 ACRS (11) JMoore, 0-15 B18 ACubbage, 0-8 E23 JBongarra, 0-9 H15 Alevin, 0-8 E23 TCollins, 0-8 E23 DOCUMENT NAME: -A:TLCON-1. ERG =
- x. .w. . ..,y .e m. we m m. wm c . c , ui .n nu.nei e . copy wem eu.comi.nu.ncw.w. r . No copy 0FFICE PM:PDST:DRPM l D:PDST:DRPM -l -l l NAME WCHuffman:ut/ w - TRQuay T Q-DATE y/o y97 V 8/2.3/97 0FFICIAL RECORD COPY w
Westinghouse Electric Corporation Docket No.52-003 cc: Mr. Nicholas J. Liparulo, Manager Mr. Frank A. Ross Nuclear Safety and Regulatory Analysis U.S. Department of Energy, NE-42 Nuclear and Advanced Technology Division Office of LWR Safety and Technology Westinghouse Electric Corporation 19901 Germantown Road P.O. Box 355 Germantown, MD 20874 Pittsburgh, PA 15230 Mr. Russ Bell Mr. B. A. McIntyre Senior Project Manager, Programs Advanced Plant Safety & Licensing Nuclear Energy Institute Westinghouse Electric Corporation 1776 Eye Street, N.W.
Energy Systems Business Unit Suite 300 Box 355 Washington, DC 20006-3706 Pittsburgh, PA 15230 Ms. Lynn Connor Ms. Cindy L. Haag Doc-Search Associates Advanced Plant Safety & Licensing Post Office Box 34 !
Westinghouse Electric Corporation Cabin John, MD 20818 I Energy Systems Business Unit Box 355 Dr. Craig D. Sawyer, Manager Pittsburgh, PA 15230 Advanced Reactor Programs ,
GE Nuclear Energy Mr. M. D. Beaumont 175 Curtner Avenue, MC-754 Nuclear and Advanced Technology Division San Jose, CA 95125 Westinghouse Electric Corporation One Montrose Metro Mr. Robert H. Buchholz 11921 Rockville Pike GE Nuclear Energy Suite 350 175 Curtner Avenue, MC-781 Rockville, MD 20852 San Jose, CA 95125 Mr. Sterling Franks Barton Z. Cowan, Esq.
U.S. Department of Energy Eckert Seamans Cherin & Mellott NE-50 600 Grant Street 42nd Floor 19901 Germantown Road Pittsburgh, PA 15219 Germantown, MD 20874 Mr. Ed Rodwell, Manager Mr. S. M. Modro PWR Design Certification Nuclear Systems Analysis Technologies Electric Power Research Institute Lockheed Idaho Technologies Company 3412 Hillview Avenue Post Office Box 1625 Palo Alto, CA 94303 Idaho Falls, ID 83415 Mr. Charles Thompson, Nuclear Engineer AP600 Certification NE-50 19901 Germantown Road Germantown, MD 20874
WESTINGHOUSE /NRC AP600 EMERGENCY RESPONSE GUIDELINES TELECONFERENCE PARTICIPANTS AUGUST 26, 1997 l
E ORGANIZATION ROBIN NYDES -
WEFTINGHOUSE MIKE CORLETTI WESTINGH0dSE RICH PROK0POVICH WESTINGHOUSE AMY CUBBAGE NRC l BILL HUFFMAN NRC JIM HIGGINS BNL l
Attachment
. . . .. . . .