,,,,, August 18, 1997 Mr. David J. Firth Program Director Generic License Renewal Program Framatome Technologies, Inc.
P.O. Box 10935 Lynchburg, Virginia 24506-0935
SUBJECT:
ACCEPTANCE FOR REFERENCING OF GENERIC LICENSE RENEWAL PROGRAM TOPICAL REPORT ENTITLED, " DEMONSTRATION OF THE MANAGEMENT OF AGING EFFECTS FOR THE PRESSURIZER," BAW 2244, AUGUST 1995 l
Dear Mr. Firth:
1 The staff of the U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Reactor Regulation (NRR), has reviewed your topical report entitled," Demonstration of the Management of Aging Effects for the Pressurizer," BAW 2244, for reference by Babcock and Wilcox owners Group (B&WOG) Generic License Renewal Program (GLRP) member plants. The resultant final I
safety evaluation report (SER) is transmitted to you as an enclosure to this letter.
As indicated in the SER, the staff found your tepical report acceptable for referencing in a license renewal application to the extent specified and under the limitations delineated in this staff SER and the associated topical report. The limitations include committing to the accepted aging rnanagement programs defined therein, completing the action items described in the SER, Section 4.1, and resolving the two remaining open items described in Section 4.2 of the SER. In referencing the topical report and meeting these limitations, an applicant will provide sufficient information for the staff to make a finding that there is reasonable assurance that the applicant will adequately manage the effects of aging so that the presstrizer intended function within the scope of the report will be maintained consistent with the current licensing basis during the period of extended operation.
The staff does not intend to repeat its review of the matters described in the report and found acceptable in the SER when the report appears as a reference in license renewal applications, except to ensure that the material presented applies to the specified plant, in accordance with the procedures established in NUREG-0390, " Topical Report Review Status,"
the staff requests that the B&WOG publish the accepted version of BAW 2244 within 3 months after receiving this letter. The published version shall incorporate this letter and the enclosed SER between the title page and the abstract. ' 47lb 7 h3 i mLm RW. f%ITS EEN 9708210252 970018 DR TOPRP ENVF A
-a4
. ll[zlL..[IG. lH. I.
c ._, ,. 4 . .
f j f
. s 6,
Mr. David J. Firth 2 i
To identify the version of the published topical report that was accepted by the staff, the B&WOG shall include an '.A' following the topical report number (e.g., BAW 2244 A).
Sincerely,
/Marylee M. Slosson, Acting Director l
Division of Reactor Program Management Office of Nuclear Reactor Regulation ,
Project No. 683
Enclosure:
Final Safety Evaluation cc: w/ encl: See next page
. 4 i
To identify the vers'on of the published topical report that was accepted by the staff, the B&WOG shallinclude an " A' following the topical report number (e.c , RAW 2244 A).
Sincerely, Original signed by: Seymour H. Heiss for Marylee M. Slosson, Acting Director Division of Reactor Program Management Office of Nuclear Reactor Regulation Project No. 663
Enclosure:
Final Safety Evaluation i cc:
l DISTRIBUTION:
RZimmerman, 0-12G18 f6D/b'IY' Project No. 683 TMartin,012G18 PUBLIC LShao, T 10D20 PDLR R/F BSheron,0-7D26 ACRS (4 copies)
MMayfield, T-10D20 OGC GHolahan,0-8E2 PDLR Staff SPeterson, 0-7026 GBagchl,0 7H15 RWessman,0 7E23 JLyons, 0-8E23 JStrosnider,0 7D4 DOCUMENT NAME: A:\PZR FSE3.wpd (RPrato/ AVL Disk) t . .i. . copy .f this ..omnt bhM. b th. bot 'C' s Copy wMhom .tt.chen.nU.ncksw. *E' s Copy wMh
.et h.n.nu.new... n a w..opy s.. e.. + u. c - .nc. ,4,? _ , o OFHCE OGC Mo l D:PDLR(7/l7 l AD:/Aff /) l AD:DRPM l NAME t YhoA vs CGrimd I & '
TMa MF MSlossoni//W DATE i/9/97 s l'/h97 / X//]Ti7 7 D5/97 T OFFICIAL RECORD COPY t,I #f [ 4.j Y
- Cu'1 puv e
- 1
0 t Project No. 683 Babcock & Wilcox owners Group Generic License Renewal Program ec:
Mr. Robert B. Borsum Regional Administrator, Region IV Framatome Technologies U.S. Nuclear Regulatory Commission 1700 Rockville Pike 611 Ryan Plaza Drive, Suite 1000 Suite 525 Arlington, TX 76011 Rockville, MD 20852 Michael Laggart Mr. James J, Fisicaro
, Manager, corporate Licensing Director, Licensing GPU Nuclear Corporation Entergy Operations, Inc.
- One Upper Pond Road Route 3, Box 137G l Parsippany, NJ 07054 Russolville, AR 72801 Chairman Eamest L. Blake, Jr., Esq.
Board of County Commissioners Shaw, Pitiman, Potts of Dauphin County and Trowbridge Daughin County Courthouse 2300 N. Street, NW Harrisburg, PA 17120 Washington, D.C. 20037 l
Mr. J. W. Hampton William Domsife, Acting Director Nuclear Generation Vice President Bureau of Radiation Protection Duke Power Company Pennsylvania Department of Oconee Nuclear Station Environmental Resources MC: ONO1VP P.O. Box 2063 P.O. Box 1439 Harrisburg, PA 17120 Seneca, SC 29679 Mr. John R. McGaha Regional Administrator, Region i Vice President, Operations Support U.S. Nuclear Regulatory Commission Entergy Operations, Inc. 475 Allendale Road P.O. Box 31995 King of Prussia, PA 19406 Jacksonville, MS f"286 Regional Administrator, Region 11 Chairman Board of Supervisors U.S. Nuclear Regulatory Commission of Londonderry Township 101 Marietta St., N.W. Suite 2900 R.D. #1 Geyers Church Road Atlanta, GA 30323 Middletown, PA 17057 Mr. R. L. Gill Mr. J. E. Burchfield, Compliance GLRP Licensing Coordinator Duke Power Company clo Duke Power Company EC-12R Oconee Nuclear Site P.O. Box 1006 P.O. Box 143g Charlotte, NC 28201 1006 Seneca, SC 29679