ML20210G289

From kanterella
Jump to navigation Jump to search
Forwards Addl Info Re Procedure Changes to Emergency Plan Per Transmittals LIC-86-614 & LIC-86-635
ML20210G289
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 02/03/1987
From: Andrews R
OMAHA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
EP-87-39, LIC-87-073, LIC-87-73, NUDOCS 8702110253
Download: ML20210G289 (3)


Text

a Omaha Public Power District 1623 Harney Omaha, Nebraska 68102 402/536 4000 February 3, 1987 LIC-87-073 EP-87-39 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Gentlemen:

SUBJECT:

Emergency Plan Changes / Explanations Enclosed is the additional information you requested concerning a brief explanation of procedure changes to the Emergency Plan for our transmittals LIC-86-614 and LIC-86-635.

Si r

y, R. L. Andrews Division Manager Nuclear Production RLA/rh Enclosures cc:

Mr. Nemen Terc U.S. Nuclear Regulatory Commission l

Region IV 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 LeBoeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, N.W.

i Washington, D.C.

20036 l

Mr. P. H. Harrell, NRC Senior Resident Inspector

$2Q$h $

f tj[

ween 4gngugocoouunw 4s s,24

4

_s

_a:w_.

Transmittal:

LIC-86-614 Title Description of Chanaes RERP - Section J Pg. 1 & 2:

Changed Emergency Duty Officer Protective Response title to Site Director.

Pg. 3:

Added statement about half face respirators, "Normally Not Used For Fort Calhoun Station Operation."

Pg. 6:

Added statement, "In addition to projected doses, plant conditions and estimated i

evacuation times should also be considered during the formulation of Protective Action 4

Recommendations."

Pg. 7:

Added statement, " Plant Conditions are evaluated using EPIP-E0F-7, Figure E0F-7-2, prior to issuing final l

Protective Action Recommendations."

4 RERP Replaced Pg. 1, 2 and 3 with those found in Definitions and RERP, updated this section with terms Abbreviations currently used in the Emergency Procedures.

RERP Changed revision date and number for Section J

- Table of Contents and Definitions and Abbreviations.

9 4

>;,e

,.--.,-,,-m-,------,-

..n-.-

,~e

,..--,,----,-,,-,--,-r

-,-- --,---~--,, - -,~----,

Transmittal:

LIC-86-635 Title Descriotion of Chanaes RERP - Section 0 Pg. 1:

Specified the type of First Aid R1diological Emergency Training and the persons Response Training requiring training.

Pg. 4,5 & 6: Corrected typographical errors.

RERP - Section H Pg. 20 & 32: Updated Table H-1, " Fort Calhoun Emergency Facilities and Station Emergency Kits" for New Equipment Emergency Personnel Carrier and related equipment.

RERP - Section L Pg. 3:

Changed order of preference of Medical and Public Health contamination control method for Support contaminated injured personnel.

Pg. 4:

Deleted Shift HP Technician as one of the Emergency Team members who accompanies contaminated person to hospital. Added Lapel Air Sampler to equipment taken to hospital.

RERP Changed revision date and number on Sections Table of Contents H, L and O.

i

-m-- - -

-