f [Michele Burgess-99-38 pg]

1 From: Michele Burgess To: Traci Kime Date: Tue, Jul 27,199912:28 PM

Subject:

99-38 Please close action 99-38. I spoke with the State of WI, the dose rates provided were for the device containing a radium source, and were sent to NRC by the State of WI. WI is going to clarify the situation with Seaman Nuclear. If Seaman Nuclear wishes to amend the NR certificate to add a radium source, then Seaman Nuclear will apply directly to the NRC.

In the meantime, since there was no fee charged for 99-38, and since at this point, we do not know for sure whether Seaman Nuclear will submit an application, nor how soon we would get it, we will close out 99-38, then if Seaman Nuclear sends in an application, we will log it in as a new action.

hI h I )

280063 9907200260 990727 PDR RC *

,,@SD _

PDR

NRC FORM 667 U.S. NUCLEAR REGULATORY COMMISSION

~ n. m >

REQUEST FOR A SEALED SOURCE OR  !

DEVICE EVALUATION INSTRUCTIONS: Send this terquest AND a copy of all related letters /apphcations and drawings to the Chief, Sealed Source Safety Section, OWFN M:il Stop O-6 H3. Change the License Tracking Systern rnilestone to 19 and assign to reviewer code 1-5.

NOTE: Retain a copy of this request with the application and background files.

8<toutstER KEGION/ LOCATION.

Seaman Nuclear Corporation Ill TELEPHONE NUMBER ~~ ~ ~ "DATE ~ ~ ~ ~ ~ ~ ~ ' '

I ~l 11

~ ~

IV 'HQ 'LFARB

~~ ~ ~ ~ "

TYPE OF ACTION REQUESTED (Check as appropriate)

NAuE OF APPUCANT~ ~ '~ ~ ~

~ ~ ~ ~ ~ ~ ~

Pcul Schmidt ~] SOURCE REVIEW g AMENDMENTOF uAit CONTROL NuuBERcS) EGMMEM ME

_' DEVICE REVIEW NUMBER (S)

LETTE%APPUCATION DATE LICENSE NUMBER (S)

-- CUSTOM REVIEW NR-587-D-104-S 05/12/1999 COMMLNIS P.O. Box 2659 Madison, WI 53701-2659

__. FOR SSSS USE ONLY_ ___ . _ _ _ _

REVIEWER. - _ _ . . _ _ _ . _ _ . _ . _ - - _ _MODEL NUMBERS . NUMBER ASGIGNED_

g John Jankovich ,

C-300 99-38 DATE RECEIVED DATE ASSIGNED DATE 10 FEES 05/21/1999 05/21/1999 05/21/1999

\ TYPE OF ACTION (Indicate the number of each type)

COMME,RCIAL DISTRIBUTION (FORMAL) USE BY A SINGLE APPLICANT (CUSTOM)

SOURCE (9C) I SOURCE (9A) SOURCL (9D) SOURCE (9B)

~

.'NEW ~~ NEW NEW

. _'NEW -

l l

f~~~

AMENDMENT y AMENDMENT '~ AMENDMENT ~ AMENDMENT '

NO SAFETY EVALUATION REQUIRED ~~ LICENSING ACTION ~~ YES

" NO FEES REQUIRED REQU' RED  :

NO (IF KNOWN)

OTHER (Specify)

' - ~ ~ ~ ~~ ~ ~ ~ '

_ _ _ _ _ . _ _ _ . _ - . . . _ _ . ~ TOTA [ NUMBER OF'- ENOTES--

REVIEW HOURS  : Modification of C-300 portable moisture density gauge.

NUMBER OF DEFICIENCY LETTERS DEFICIENCY CALLS

~

U-

~~ ~ ~ ~ ~ ~~~ ~-~ - ' ' ' ~ ~ ~~ ~ ~~- ~

TYPE OF FEE'~ -

FEE T GO Y AMOU T R ElVE

~~

r f6 CHECK NUMBER ~

[3 ~ ~ ~ '

'^ 9A

~

DATE OF CHECK 9B LOG 9C 9D APPROVED BY

.. f -(-

. . . W ..'- . -

. -- . lM -

,.DATE OF RETU fl .-

_ ,,, _ _ _ _ _ _ _ _ _ - - /.FL-- . --&/MY7 -. -

NHL F OHM W p.utW) FR.NTLD ON RLL(LLL U FAPER Thea form was owagnero weerg soiurma t

,,c6

' fic 6 Ror Measurements of the C-300 Density Gauge, Seaman Nuclear Area Distance Reading mR/hr Source Position Top 0' 23.0 closed Top l' 4.8 closed Top 2' l.5 closed Top 3' O.8 closed Top 0' 4.4 open Top l' l.1 open Top 2' 3.5 open Top 3' O.32 open R Side O' 28.0 closed R Side l' 6.4 closed R Side 2' 2.1 closed R Side 3' O.91 closed R Side O' 10.1 open R Side l' 4.8 open R Side 2' 2.1 open R Side 3' 1.2 open l Back O' 24.0 closed Back I' 4.3 closed Back 2' l.95 closed i

Back 3' l.0 closed  ;

l

Page 2 C-300 Area Distance Reading - mR/hr Source Position Back O' 8.1 open Back l' 3.0 open Back 2' l.8 open Back 3' l.0 open L. Side O' 7.6 closed L. Side l' l.5 closed L. Side 2' O.67 closed L. Side 3' O.39 closed L. Side O' 4.5 open L. Side l' l.45 open L. Side 2' O.47 open L. Side 3' O.26 open Bottom O' 22.0 closed Bottom l' 4.5 cbsed Bottom 2' l.5 closed Bottom 3' O.86 closed Bottom O' 300* open Bottom l' 27.0 open Bottom 2' 11.0 open Bottom 3' 5.0 open Neutron O' 20.4 mrem /hr* closed Neutron O' 48.0 mrem /hr* open

  • Bottom contact measurement was not corrected for beam area vs. detector size. The beam area was about 2 inch diameter at the bottom plate.

t REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (CORRECTED COPY i ssued Aprii 19, 1995)

NO. I L - 1 3 6 - S - 3 2 70kTFS: February 26, 1979 PAGE - 1of4 SOURCE TYPF: General Application Neutron Source MODEL RAN.C1. RAN.C2 ClSTRIBUTOR: Amersham Corporation 2636 South Cl earbrook Drive Art i ngton Hei ghts. IL 60005-4692 MANUFACTURER- Amersham International Pl c Whi te Li on Road Amersham Bucki nghamshi re, Engl and HP79LL i 50 TOPE: MAXIMUW ACTI VI TY:

Rcdi um-226 204 kBq (5. 5 mi l I i curi es) - RAN.Cl Radi um-226 til kBq (3. O mi I i i curi es) - RAN. C2 i FAK TEST FREQUENCY: 6 months PRINClPAL USE: . (G) Portabi e Moi sture Densi ty Gauges CUSTOM SOURCE: YES x NO

-- f 5 0 5 / 5 0 i S

REGISTRY OF RADIDACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (CORRECTED COPY issued April 19, 1995) 10: IL-136-S-327-S E February 26, 1979 PACE 2of4 SOURCE TYPE: General Application Neutron Source DESCRI PTl ON:

Thoso sources are designed for incorporation into moi sture/ density gauges.

Radi um bromi de power i s i nti matel y ml xed and compacted wi th berylIi um metal powder to form a peliet. The radicactive pelIet i s then doubt y encapsulated within reactor grade stalniess steel capsules which are sealed by argon arc wel di ng. The dimensions of the RAN.C1 capsul e are approximatel y 7 mm i n length by 10 mm in diameter. The dimensi ons of the RAN.C2 capsule are approxi matel y 14 mm i n I ength by 9 mm i n di ameter.

t ABEti NG:

Sources are I abelod by permanent engraving on the capsule with detalI s of the foi l owi ng:

1. Ituclide i
2. Activity
3. Model number
4. Serial number
5. The word " Radioactive'
6. The word " Amersham" (The date of assay i s givon on the unique certi ficate which i s supplied wi th I cach source. )

The sources are suppli ed in Iead pots. A typical I abel which would appear on the Icad pot contal ns the foi)owlng informati on: "Cauti on Radl oacti ve I Material" statement, trefoii symbol. number of sealed sources i n the contai ner, model number, activity per source, Ra-226, date and di stributor's name address and Iogo.

PROTOTYPF EVALUATION: 4 l

Both capsules meet the requi rements of the I AEA Special Form Regulations.

Based on these resul ts and on ANSI tests on simii ar capsules, the manufacturer estimates that these source models would achieve at I cast an ANSI rating of 43344.

I

l REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (CORRECTED COPY issued April 19, 1995)

N0: IL-136-S-327-S NTE - February 26, 1979 PAGE: 3of4 SOURCE TYPE: General Application Neutron Source FXTERNAL RADI ATI ON LEVELS:

Dose rates were calcul ated by the manufacturer for neutrons and gamma rays at 5 cm and 30 cm from-sources contai ni ng 2.7 mci and 4.1 MCI radi um-226 beryl l i um. The resul ts are tabul ated bel ow.

Acti vi ty (mci ) Dose Rate (mrem / hour)

(5 cm) (30 cm)

O E G E l 27 17 891 0. 5 25 4.1 27 1350 0. 8 38 l OVAllTY CONTR0l:

Duri ng manufacturc, stri ct process and quali ty control procedures are empl oyed. The raw materi al s are very carefull y checked agai nst speci fi cati on, i ncl udi ng an exhausti ve check of the hi ghest grade stai nl ess steel for chemi cal puri ty, mechani cal proporti es, physi cal form, freedom from porcs, cracks. stri ngers, etc. A bubble test i s performed on both the i rner and outer capsul e foll owi ng wel di ng.

Usi ng a BF(3) counter array and paraffin wax moderator assembly, the neutron emi ssi on of each source i s compared with the emi ssion from a standard radium-l 226/beryll i um source. The standard source has been cali brated by further compari son wi th standards measured at the Nati onal Physi cal Laboratory, Teddi ngton, Engl and.

Each source i s l eak tested by wi pe, bubbl e, and emanati on tests.

i The customer i s provi ded wi th a certi fi cato documenti ng the source content and I the resul ts of the l eakage and contamination tests performed on each source.

l l

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEV1CES SAFETY EVALUATION OF SEALED SOURCE (CORRECTED COPY issued April 19, 1995) 11 0 : 1L-136-S-327-S DATE : February 26, 1979 PAGE- 4of4 SOURCE TYPE: General Appiication Neutron Source LIWITATIONS AND OTHER CONSIDERATlONS OF USE:

The source shalI be distributed on!y to persons speci ficalIy Iicensed by the Department, the Nuclear Regulatory Commission (NRC), an Agreement State, or a Licensing State.

Thi s source shalI be ieak tested at six-month interval s using techniques capabt e of detecti ng 0. 005 mi crocuri e of removabt e contami nati on.

Handli ng, storage, use, transfer, and di sposal": To be determined by the I i cens. ng authority. Consi deri ng thi s source exhi bi ts bi ght surface dose rates when unshielded, the sources shout d be handled oniy by ,

experi enced, Iicensed personnel using proper engineering controls and  !

procedures.  !

The source shalI not be subJ ected to environmental or other conditions l of use whi ch exceed ANSI N542-1977 C43344, '

. Thi s registration sheet and the information contained withi n the references shalI not be changed wi thout the written consent of the l Department.

LICENSING RECOMMENDATI ONS:

These sources meet the criteri a of NARM Gui de 2 enti tled " Scal ed Sources" and should be speci ficalIy Iicensed.

REFERENCES:

The rolI owi ng documents for the Amersham Corporati on Model RAN.C1 and iMN.C2 are hereby incorporated by reference and are made a part of this registry document:

1. Letters wi th attachments dated September 1, 1978 and October 30, 1978.

ISSUING AGENCY: IIli nois Department of Nuct car Safety DATE /1 95 REVIEWED BY:_- ~_. wa Daren Perrero DATE /4/ 4 CONCURRENCE:  !