ML20209H933

From kanterella
Jump to navigation Jump to search
Forwards Safety Evaluation Accepting EPRI Rept TR-105696-R1, BWR Vessel & Internals Project:Reactor Pressure Vessel & Internals Examinations Guidelines (BWRVIP-03) Rev 1,
ML20209H933
Person / Time
Issue date: 07/15/1999
From: Strosnider J
NRC (Affiliation Not Assigned)
To: Terry C
NIAGARA MOHAWK POWER CORP.
Shared Package
ML20209H937 List:
References
TAC-M95369, NUDOCS 9907210096
Download: ML20209H933 (2)


Text

f 9

-p%.y 8'

UNITED STATES

{

g NUCLEAR REGULATORY COMMISSION O

WASHINGTON, D.C. 205554 001 July 15,1999 Carl Teny, BWRVIP Chairman Niagara Mohawk Power Company Post Office Box 63 Lycoming, NY 13093

SUBJECT:

FINAL SAFETY EVALUATION OF "BWR VESSEL AND INTERNALS PROJECT, REACTOR PRESSURE VESSEL AND INTERNALS EXAMINATION GUIDELINES (BWRVIP-03) REVISION 1"(TAC NO. M95369)

Dear Mr. Terry,

The NRC staff has completed its review of the Electric Power Research Institute (EPRI) Report TR-105696-R1, "BWR Vessel and intemals Project: Reactor Pressure Vessel [RPV] and intemals Examinations Guidelines (BWRVIP-03) Revision 1," dated March 30,1999. This report was submitted in response to the NRC staff's initial safety evaluation dated June 8,1998, regarding your initial submittal of the BWRVIP-03 report dated November 10,1995, as supplemented by letters dated April 16,1996, and March 12 and July 7,1997. The BWRVlP-03 report, as revised, proposed guidelines for NDE techniques and inspection standards intended for voluntary implementation by BWR licensees in order to effectively examine and ensure the integrity of safety related RPV internal components.

The NRC staff has reviewed the revised BWRVIP-03 report and finds, in the enclosed Safety Evaluation (SE), that the guidance of the BWRVIP-03 report is acceptable forinspection of the subject safety-related RPV intemal components. This finding is based on information submitted by the above letters. The staff has concluded that licensee implementation of the guidelines in BWRVIP-03, Revision 1, will provide an acceptable level of quality for examination of the safety-related components addressed in the BWRVIP-03, Revision 1, document. This letter also closes the open items on the BWRVIP-03 report in the staff's SE's for the following BWRVIP reports:

1 BWRVIP-18, *BWR Vessel and Internals Project, BWR Core Spray Internals inspection and

! f ';

Flaw Evaluation Guidelines," SE dated June 8,1998; l

BWRVIP-26, "BWR Vessel and Intemals Project, BWR Top Guide inspection and Flaw Evaluation Guidelines," SE dated May 18,1999; BWRVIP-42, BWRVIP Vessel and Intemals Project, "BWR Vessel and Intemals Project, LPCI

)

Coupling Inspection and Flaw Evaluation Guidelines," SE dated June 14,1999 BWRVIP-47, "BWR Vessel and intemals Project, BWR Lower Plenum inspection and Flaw

\\j Evaluation Guidelines," SE dated April 7,1999; and, BWRVIP-48, "BWR Vessel and Intemals Project, Vessel [ Inner Diameter] ID Attachment Weld Inspection and Flaw Evaluation Guidelines," SE dated March 21,1999.

01000R

/

_ E FST 9907210096 990715

{\\ pJ ' g DR TOPRP EXIE R u

F i

c C. Terry Please contact _ C. E. (Gene) Carpenter, Jr., of my staff at (301) 415-2160, if you have any further questions regarding this subject.

Sincerely, Jack R. Strosnider, Director Division of Engineering Office cf Nuclear Reactor Regulation

Enclosure:

As stated cc: See next page DISTRIBUTION:

EMCB R/F GHolahan WDLanning, R1 PUBLIC MEMayfield BSMallet, R2 File Center TYChang JGrobe, R3 ACRS KRWichman AHowell, R4 Document Name: G:\\BWRVIP\\BWRVIP03 Rev1 FSER.WPD INDICA 1E IN BOX: "C"mCOPY W/O ATTACHMENTENCLOSURE, *E"= COPY W/ATTENCL. *N"mNO COPY o a EMCB: LPM E

EMCB:SLS (,

EMCB:BC DE:DD DE:D

@/

,n 3

CECarpenter ojjg RAHer.mann$

WHBatemarQPRHWessmaMg/

JRStrosngr 06/16/1999 L" 06/ M1/99

$/1/1999 0$/ 7 /1999 OI/ ($ /1%9 4pg OFFIDIAL RECORD COF1Y')

4b 9/d99 l

L L'