Text
{{#Wiki_filter:$~/hb w g Tech / Ops, Inc. g g RECEWED g ~oe. ~..on s e sonn x nu. ~ c
- sumnsts-w.menuun.oisos g gg9 885 > E icgf August 12, 1985
' Tannon. tair) 272-2000 g x_j nG Wsits # " g, Mr. Charles E. MacDonald, Chi Transportation Certification Branch Division of Fuel Cycle and Material Safety Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555
Dear Mr. MacDonald:
We request amendment of USNRC Certificate of Compliance Number 9006 issued for our Type B(U) package Model AI 500 SU, USA /9006/B(U). We ask that this amendment reflect a modification to the design of the source holddown arrangement. This modification is designed to provide a greater degree of safety to the operator during the loading and unloading of this package. We are enclosing eight copies of the revised safety Analysis Report for this package. We are also enclosing a check for $150.00 as the application Fee for this request. 7 ( ) We trust that this application contains the information necessary for your review. If we can provide any additional information, please contact us. gincerel,t,,f / NN r x gu, s. Av '., Joh'n J. Munro III y[3 Technical Director N goc W D usMG h E SEP 1O GB5' r .2 %[siclet JJM/ged 9 e ** enclosures y 0 cn 91 h h 6 B hb
~ e. i INSERTION INSTRUCTIONS FOR REVISION 2 TO SAFETY ANALYSIS' REPORT FOR TECH /0PS, INC. M0CEL AI 500 SU TYPE B(U) PACKAGE USA /9006/B(U) 8 AUGUST 1985 REMOVE PAGE INSERT PAGE 1-2 Rev 1 1-2 Rev 2 1-3 Rev 1 1-3 Rev 2 1-4 Rev 0 1-4 Rev 2 1-5 Rev 0 1-5 Rev 2 1-6 Rev 0 1-6 Rev 2 1-6a Rev 2 1-6b Rev 2 1-9 Rev 0 1-9 Rev 2 0-1-10 Rev 0 1-10 Rev 2 2-3 Rev 0 2-3 Rev 2 7-13 Rev 0 7-13 Rev 2 7-14 Rev 0 7-14 Rev 2 7-14a Rev 2 8-1 Rev 1 8-1 Rev 2 0 1 L
I -( 2 1 i l i 1 i s e l 0 i i i. j I l l t SAFETY ANALYSIS REPORT l TECH / OPS, INC. MODEL Al 500 SU i r TYPE B(U) PACKAGE l I USA /9006/B (U) l l i t t i I i G I Revision 2 I f i 6 August 1985 i { l l l l i l 1 i l I l O I i w
10 GtDt1R1 1DLDIED%isD /^\\ 3.1. IDLI9 dust 19D d Tech / Ops, Inc. Model AI 500 SU is designed for use as a radiographic exposure device and a transport package for Type B quantities of radioactive material in special form. The Model AI 500 SU conforms to the criteria for Type B(U) packaging in accordance with le CFR 71 and IAEA Safety Series No. 6, 1973 Revised Edition (as amended). 1.2 ERChDSD DREGriptiDD 1.2.1 EashasiDS The Model AI 500 SU is 279 millimeters (11.00 inches) Icng, 124 millimeters (4.88 inches) wide, and 141 millimeters (5.56 inches) high. The packaging incorporates a handle which extends 38 millimeters (1.5 inches) from the top surface and is 190 millimeters (7.5 inches) long. The total mass of the package is 27 kilograms (65 pounds). The radicactive material is sealed in a source capsule which ccnforms to the requirements for special form radioactive naterial. This source capsule is installed onto a source holder assembly. The source holder assemblies used in conjunction with the Model AI 500 SU are listed in the appendix. The source holder assembly is housed in one of two titanium source tubes. Each source tube has an outside diameter of 11.3 millimeters (0.438 inch) and an inside diameter of 9.5 millimeters (0.375 inc h). One end of the source tube is enciesed by means of a plug which is soldered to the source tube. The cpposite end of the source tube is inserted in the lockbox which is welded to the front plate. The source tubes are surrounded by uranium metal as shield-ing material. The uranium shielding is cast in place around the scurce tubes. The mass of the uranium shield is 18 kilograms (39 pounds). The uranium shield is encased in a Type 304 stainless steel housing. The housing is 3.4 millimeters (0.135 inch) thick. Mounted on the f ront plate is the lockbox assemblies. The locking assembly is used to secure the radioactive source and source holder assembly in the shielded position during transport. 1-1 Revision 0 1 March 1985
Surrounding the lockbox osesmbly is the protectivo cover. This cover is fabricated from Type 3E4 stainless steel and is attached to the package shell by means of a hinge and a seal bolt. The head of the seal bolt is drilled to provide a means for attaching tamperproof seal wire during transport. On certain
- packages, additional shielding plates are installed to reduce the surface radiation level.
Thesc plates are 6.4 mm (0.25 inch) thick and welded to the out-side of the package as described on drawing AI 5ee SU 93. 4 The outer packaging is designed to avoid the collection and retention of water. The package has a
- smooth, unpainted stainless steel finish to provide for easy decontamination.
The radioactive material is sealed inside a stainless steel source capsule. This capsule acts as the containment vessel for the radioactive material. 1.2.2 Opexational Esstyxes The source holder assembly is secured in the proper shielded storage position by means of the locking assembly. The source assembly is held in the shielded storage position i by means of a lock slide. The lock slide creates an interference with the stop ball, preventing its movement out of the shielded position. The lock slide 'i s held in position by a latch pin and by a key operated lock. The i lock slide cannot be moved from the lock position until both i the key operated lock is unlocked and the latch pin is depressed by the insertion of a source guide tube into the lock body. Additionally, a cap is installed over the source holder assembly and attached to the lockbox. This cap is seal wired to prevent inadvertent loosening. The cap also t provides an additional means to prevent movement of the lock slide. An outer protective cover is installed over the lock box and is locked in the closed positin to prevent unauthorized access. 1.2.3 CanggD1s 91 gbg gaggsgg The Model AI See SU is designed for the transport of iridium-192 in quantities up to 128 curies in Tech / Ops source assemblies listed in the appendix. The source cap- ) sule used with each of these source assemblies satisfies l the criteria for special form radioactive material in accor-dance with le CFR 71 and IAEA Safety Series No. 6, 1973 Revised Edition (as amended). i 1-2 Revision 2 8 August 1985 O
i i 1.3 AEH FDIE Drawing A15005090 Sheets 1 through F 1 Drawing AI500SU91 Drawing 42402-1 l i l Drawing 42402-4 r Drawing AI 5005092 i l Drawing AI 5005093 i i a l i i l t 1 i i { l l 1 1 t 4 I I i i 5 l l i l i 1 1 ) i 1 1 [ j e .\\ I i 1-3 Revision 2 8 August 1985 3 i l 1 4 1 .I 1 f r
Is\\ / g ($ o q j[I
- c. e Ie 9
g g Ch 1 q, x # f 4 ~ ) ,4 ?k '~ e-r y N !~ ll $- 'e /t l [9' fO y / 1, e ,,8w, r l, E
- c2
- uff
) s a s? 5 r e se a s me w ~ s s., ~ 1 \\ k; } E~
- 7., n i
D 3 \\ gy / y I i ~ l ;o [ z'n,r-3 j ./'..# ~- /. \\ I '*' ora,,> / >< Ty ~/ p y ' ' 'i o fgg p['. k:,7' j/ / y l!l. I{N/N '~
- ** 0 ngl y t o E3
~~
E,! 1 1 9 ]I g,l ' s. .< s 2 ,m x Y h ~ g e i: V l gg / i / / / /t g3 ? i v / / / 7 i sr l \\ s' s \\v 4 v,..
- s
_[ )_ sN- _ l _I 3 .I. 3 s ra l s 0 {,' 5 y i.!) N w[=&i 1 o_ e t j i j l >/j l ll # i (j . i c 5 [ j i u N, t t-h k. m ss ()) d'- G n ~4 L Q EE 9 t-m W i l r 1 i 7 d'h H 6 L. i y c i, / % ,l gI -{-(*/ Ql Q4 s .c e ' J l c; sJ ;3 I, R i -p En c j 9 ($ lT.J@/rijbl ii id_..,,. _ __l. l l I _l.1 f ~
-~_--,.-- -- -
- 7 Ec
~ i' > ( ( 3, L g i, 8 s' t-g' rL s,
- 3. $
5 k,,k I21 1 t .e c e-gb L e W CL N,,g 'k " b_T 5, l. 9 l' ' h 5 $. c t' EA k<.N2..M o 65 e* u a >9$ 7 ' d b, EOR C' 9 x 4 i h. NNE ?$ 55<!= E, 8& I l A 1 'N e., w% !2 + & "> 5 \\' kN l .( \\ dO Rep t u nS p 5 ga i g "I a 2 8 s 5 i I -m x a y i \\ b u. x 5 Q 1 i N al. C'- 5 s/ C u- ~ n a c ('b & ( f E S b. \\ a l !.,. l uv b'a, 8 C A y
- ~
~ s sf s S s c N l s ~. ll o'L_a -C e O \\ a 8 h i ~ e 4 .g @ h "f"" I ~ V'M)%' t-t-e / \\lb.N '\\ C$ 'i 8 p s \\ \\ p.' C / z' ./ ~, Fh a s / l E C t?l / I f $3 5 w -,,, e / 'N' ' vs, '% b Q. ~ < j!! h r o 2-N / h E E. N(- 0 t-e p D
- - Mb 5
h. 9 25 i 6 E! w a c :- w 6 5 age n mQ c Es R RR + a $8C is c g gJ 'c @
- s of c
h DC"-C5 e d 8 p-w CLEW u ~
m ae l g. o ',a ~ i
- u. P 88
$ 9 f n v -c G ,N 3 I teE ll o' M e' (' s-I i e b k 2 b i x, t. p gg $ a f L it e = .i e 8. i:. j l N 1 "' l"' ' g 9 f l k! U_h- > q_ e ,~ r 'f /, Cd ' "; ' d s '.' ' 67 l bn i 3 @,(- k ( x *- r O s 1g*o g-g f ;- u 1 E E)) g[ O y Q o ' l t-3 O E N $ =., 5 r n \\b c 4 r ( ) ( a. b Y 0 ') k ~ s' i ' g gg l M' y
- f. c-S
< m-v ~,., 7.
- E b
- h.. 3E
_.1 ' *e m a D L et nq /' m ',8 t;l' fd-f u n t 9e b-y cu ga g l [b ( 4 N. \\ O b E2 Ls l s*e s% r' 2 *~ F' s E5i EF l L; cp E.aa p.$ Fe 5 'k>". g 5 w In) 3 10, i 9S 1 s 3 g a 1 v g o
l! ! If l \\._ {, R L i ig i 12 I i Ni - 3 .11 3 k = I ~ ng e m w w ap zuv "y u Oe[ 3T y .Ee Yff/////Ad )- V[/M 'f .g 43 E i N i g Q / )j/f J W /c. L / L
- p
/0 h Y V[" A
- A sx 3
a r DS k S E
- t ud l-41
Il FH i (] iG HIGH HIGM fg / i n / R RADIOACTIVE MATERIAL S2h 5 PECIAL FORK 3 1RIDIUM-192 120 CURIES MAX. [M $ $ MODEL500 SU n T YPE 1(U) PAC KAGE. WEIGHT: O LB/27KG. z)ggg-6d PACKAGE IDENT. NO: _;T{O USA /.9006/B(U ) p vqt iw usa, - PROPERTY OF a E, fe./0z \\ Tech / Ops,As 1C G i.:,um g e_=.. ecn, v4 u.s.a. 9
- THE NAMEPLATE IS THE TOP PLATE OF THE SOURCE CHANGER BEJGRE WELDING OCTET 1.ALL M A 'c % PA"U:* @1 S M ( trtc E7 N I itf70 p MuiDAE.OlO OEEc MnT E RIALS TECHN'C AL optR ATIONS INC.
10 CA E2/Ed ST 57L RADIATION PMODUCTS DIVISION B U R U N G T O N. MA 01903 F6N.59 D*G TITLE nome m~=>
- c.n: r.n:,,...
N AME PLATE W/ m ,N _. me er ,o h C J55triCAfiON Silt D*G ND m[ ,u g x A AI5009U91 A m.tD., .Ns.t, ...:113s s, s:.c Nms is cn i or 2
C. E V. DATE DESCRIPTION l -GMRACTER5 d LOGO-BLACX ON 1ATitiSMKGROUHD If e LOCATED ON TDP r / PLATE OF SOURCE Ulnt16ER 1 %/Onl Tech / Opt,AW lnc.. 8 1.0 NORTH R.F.Mth, VA U.S.A. M 4f = =, CWWAGER) 4 SYMfM. wanm on aw ~ si. ~ BACKGECUnD ,z / v q 4.4 CAUTION g RADIOACTIVE MATERIAL 'l LOCATED On front FIATE OF 70RCE CHANGER WATL .005 THX ALUMINUM WITH ACHE 51VE FKK l " II N TECH / OPS, INC. [1 0T D Tec.h Ops RADIATION PRODUCTS DIVISIO*4 SURLINGTON. MA 0l803 FIMfSH DW G TITLE =. v = m.,... NAMEPLATE s h b,/ Z u M Jar / 2 g [ CMLCRED SY g 3 1,
- ;f-A AI?005U91 CLAS510 CATION SIZE DwG. No.
REY. t R ACitom! SCALI fKr#E l SHEET 2 OF 1
g- ^? g d ) q )0 S / [/ ^ 2 EIM 4 9 ^ ". [ w-3 6 d 1 ( l l E7 m,, B I aA "E ? S L U .l %-BD 4 _ ~ '3 r QV " " " / A N t 9 P a - TI c J ( )N ) N I 9 m _LL( )R gR4 )E M7 MR+ I7 6 EO NO OO8 7 O 7 f e_ t m t f (C 6 ( (7 2 I ' y U U 0 CT r ( 4lU 72U u, U 9 ST )69 3 )'
- ) 4 RA
= es 2 67 265 1 9 7 4 4 [,g 00 00 00 UM Z R Ol9
- 5O 08-O8 o6-1?D 0
0 0 OD = p 5-t 0 i l4 44O 44( 2R 7R 7R g O O O g "] R Oy0 'f o0"J 00 5 7 C I O A A E Y2 7 f p S I 0 I M t ( ~ E 5 n E R R C "g D. H V D T T C O R E E 7 7 j M7 U R P S U T A S6 A 9 C a G . 7<J f f A B 8 C, l f 78 E T r I. R O 0 fC P g U OA f 2 4, O u ) 0 g 4 A N m I0 "/ 6 /, M h o. L2 B L6 H f E m D,AB g OC E9 A u A r. C0 M r M E A D t OA f0l M6 T4 GG G m N MIQ0 1 f s . Bl 1 4 3 7-l 4 y 5 3 21 2-1 N [ ) 2 I 2 2 g l 3 s N 4 1 4 4 5 i f 1 2 2 2 2 M 2 2 7 5 7 2 2 2 2 N M 7 7 2 ? s 1 R 7 J 7 7 T 7 7 Y 9 T T 7' 3 7 4 ? W 5 5 7 7 3 M2 G I 2 2 2 2 J 2 2 2 2 2 2
- y 7
K X M K G M x K T K R K K p K M mM S t) 5 S 9 S 2 5 5 i S A / A A A A M M A B s V 4 4A A ? a t_ I / ] 0 0 5 f 9 9 5 y 5 7 0 0 0 0 21 2 mg l 2 2 2 2 2 2 2 2 2 2 2 3 3 2 2 2 8 8 8 8 8 B 8 8 9 9 9 9 1 9 1 9 j 2 y sC 6 Vp . l 1 4 f, X, 2. X. f, g 2 r, 4 4 M 4 M M 6 2 2 2 X.; 7 7 X. 2 7 2 J 2 2 2 2 2 ll 2 [ G 6 6 0 y 1 1 f l '. 2. 9 9 8 6 6 8 4 0 2 l 1 1 5 5 2 2 7, 7 E. 6 J wT l 2 }f 2 2 2 2 2 f H 2 6 9 4 2 7 8 0 4 G 5 46 6 4 s E 9 6 1 ) 4 6 8 6 9 4 A0 9 5 9, 4 ] l 6 6 1 81 4 M 5 21 6 6 6 G7 6 6 6 1 J wY l 1 l 1 1 1 %. 6 4 6 1 J ) 6 4 9 7 2 -{ 7 68 6 6 9 5 4 0 0 0 1 0 2 7 e 9 8 7 1 0 l. 7 7 E_6 7 17 7 7 7 7 2 2 8 1 'l s G_ I M 4 6 1 h s m Ld p W w W D 5p E D m S5 r W* w s m T w N i O m I 7 r O u N H t i s T E r T c 7 P F S 7 o t % P S u 7 d J'1 O t C w t i 1 / r y f L ff y }U )r M D U / i P H t f r t f l ff T 0 l t t E u o 1 r 0 7 5 u K 7 i m C 3 T U ( T I t G i K A C T. m % *S. Y. NM T t w p N u M m W F R 7 r W M A A 4 f eA E f T_ d 0 I I e A R e m C a IU D M W( M L U I I. m I. I. H / U U 4 U l u T f / E L 6 A A 6 A G A 4 A G A A AG G C S S O t Uo l 7 7 7 7 7 7 7 7 7 7 7f7 7 7 E n j 7 7 E + 8 8 s s r x e r s s s r : s CEt t 7 7 7 7 7 T 7 7 7 7 7 7 7 7 7 7 RSc 3 7 A 2 mC I M l 0 O O 0 0 O O O O O O D D C D D D U O D D D c 0Vv D D $ % I'y fy %$ 3/g 0D E g 8 gg V Sf'@7$VV 97 m h l 7 o O 0 U PR O0 r T 9 A o l W W W W W lw W W W W W W l l W W W W W - C2 R R R R R R R R R R p R R R R R R 0 O 0 O O 0 O O O O 0 O O O 0 C C C 0 N4 w 5Wn W_S D 8 9 S 9 8 8 8 6 B 8 8 8 3 9 8 8 8 I - ] M W W W O W W W V W W W W W W W v W N 2 I. Dw T FL M 2 8 9 9 D 7 ? l 8 36 M 4 0 1 dos 7 J 2 1 '3, 1 A 2 3 1 2 O H C 2 D R 2 2 2 2 M 5{ 2 5 2 2 s 2 2 2 5 Y 7 1 7 5 9 5 9 7 3 2 I 8 C 9 7 Y 7 y } 9 5 7 7 9 7 7 7 7 5 f f R 2 2 0 2 G 2 2 2 2 2 G f HT 2 2 2 2 N AP K M K K M E X M s K T l F y 7 K M-5 5 9 9 FCM 5 5 5 5 5 5 5 5 T 5 5 l B S 3 8 B B B 5 8 E 8 8 9 e e8 0 F Cd VI YR D'n D MC 5 0 0 0 0 O 0 0 0 0 O 0 0 0 O 0 0 0 f t N 2 g E f L l / 1 21 2 2 S 2 21 2 2 2 2 2 2 2 2 2 2 0 I g 2 1 I 1 w 5 1 1 I 1 1 7]s ,g A A) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 N5 t E 9 9 9 S 9 9 9 9 9 9 9 3 9 9 9 1 9 i f I 1 1 1 1 1 s 1 1 1 r 1 9 1 G (U T ,a 9 R 1 I I I I 1 I 1 I E w R1 R 91 R RI I R R R R R RI 8 P 9 Rl R Y [4 *a; I I Sl _a A D )- 2 T C S n N W O l 2 7 2 7 mon 2 7 A A 2 B C C H J C E. M I 2 I l I I I 9 I; T 7 G G G R s 9D I I E a C G C 7. M'm-1 0 e le 6 O 3 E 6 8 9 9 5 r-T T 0 7 E
- t. e. E 9
1 C 0 0 0 3 4 T 9 c 0 7 7 7 7 s 9 9 9 9 9 L[S 1 y i 4 4 4 Al 0! 0 v 0 1 9 9 9 r r 1 % N t 1 ? 4 4 a 2 02 3 3 7 p 3tu. L. T. L L L. I. I I. 4 I I. I I I I. I. 1 A A A A A A A A A A A A A A A A A rt; I R Uwn O i 2 7 4 i 6 T 8 9 O 2 3 H SI 6 7 t 7r I 1 1 1 1 f lI
- (N Y
- d. ' t,C
'y q t 4 E !. 7.t s :c g "e9 $. 5 7 1," f q Ld B mt %g TF 8 -g e e E23i=a e i tst Ni,;I $
- de n_
- s 9 li 5 el I o c ,9 oms - m e ~3 - S k. v I ( [ E o Ow m o oe On ow% i j,< [8 EEE EQ, SS b EEf.$ g S i-- { s_ m - e kb o r sc 5 E c l q.h O h ,oe Eb N,b g
- s VQ
? I e y ve e s e I .a, h, _ _ _ _. j g 'Wr % g s ,R a 3 l. 8,3 c, E,8,,58 i n i s SS. E E i e k yl.,,.I. l s n s e , hh o e n m ~1 ~ k w (py;~ H e g e h z ._1 -..u,O e = 3 m i -"I l g E F 4 R E 6 ^i i O d 7 6 6 I o e o el8 h N b Q N N y! e z e e o 'O C h $I n L, I n l O n-2 = b d ),i ( Eea = 7 8 u q F s n 2 F .} e e e e s e cW> l f 'O t G E Rd 8 E. N. "e ~ g ~ c- ~ w k h hihI k k h. !S ~D $I$ I i$'
- t
} - %g g@ c x e t > r E 3 4 e5 as EE E E E E E $ Rq.c p. %e e. i a- .a as ac a s an cp2 y[2 a 5 cs 3 g w ; w w e - w e E Ep l g{E h; o 1 -e o O-O- k 0 -'N y m a' dtc I C D E o 3 e. e e ao eem = tf j %x i ggo a -\\ *% I E g p' 4 3 s E B E l a*g i s a I! a5 V a ss i l 4 E 4 m o g_I i
- i o
o a o O a a a cm '.i' ' t, R e a R 5 {p i 0, E E E E E E E E d 4 8'I i i s 4 s 4 4 e s [ db l %b T Y 9 [ $ f., c. i te. h 3 h h k- { )"w I Ys 3 0 L I E o m 55 a E l i, n. s y e i e s n
L_ h) W ~~ 2 g S k, 8 <g ! y* P e e e (V j, y t.; c. 5% F ? a y Rw i i
- r.
?? 5* .fk ps r [ ip l,r,ill r< t 1 i, iL .t k e b ,' g t k p! l;l'll! T Qlg~ 4 {A y <e t sk ,./ Ei 9 e-Y j sk. a ?s , -f,,'? t I r ./ bt n.! / /,s-ff ,Y 's. - // b I ( ez / =. 44 i e, 8 '[', ) a-y 6 O 4 '. &'4 2 2
- e
[s ,M., ( s w T. 'f - l E. M.;w
- s g
i a s y,;.. / o n >a f c / ~, - ,x:.. h, g\\- / \\ t I ny b .,',' y: t g m ? ~ j j p -- 5!x. y[ 5 ( s ,c s p_ .s ,.A 3 L . p; ' .m 1 " a L a V i 6 / k N r ki< L. = ~ ^ M/g $ Nef t I-tI
iia i b 8 v a 1 M L i IN _1 t N g - s al i ws S t j;; g Ny g ) i o / y\\ / / .ik Q / k o/' l. 4 4 9 i 1 / + \\} 1 s, to Dd 5 o !? i t see
2.0 Structural EsalvatiDD 2.1 Structural DesisD 2.1.1 DisguggicD The Model AI 500 SU is comprised of five structural compo-nents: a source capsule, source holder assembly, shield assembly, outer housing assembly and locking assembly. The source capsule is the primary containment vessel. It satis-fies the criteria for special form radioactive material. The shield assembly provides shielding for the radioactive material and, together with the source holder assembly and locking assembly, assures proper positioning of the radio-active source. The outer housing is f abricated f rom 3.4 millimeter (0.135 inch) thick Type 304 stainless steel. The housing provides the structural integrity of the package. The package outer cover, also f abricated f rom 3.4 millimeter (c.13 5 inch) Type 304 stainless steel provides protection to the lockbox assembly. The lockbox assembly secures the source holder assembly in the shielded position at the bottom of the source tube and assures positive closure. 2.1.2 DRSigD Criteria The Medel AI 500 SU is designed to comply with the require-ments for Type B(U) packaging as prescribed by 10 CFR 71 and IAEA Safety Series No. 6,1973 Revised Edition (as amended). All design criteria are evaluated by a straightforward application of the appropriate section of le CFR 71 or IAEA Saf ety Series No. 6. 2.2 b'tightB RDC C9DttxD Di Grasity The total mass of the Model AI 500 SU is 30 kilograms (65 pounds). The shield assembly consists of 18 kilograms (39 pounds) of depleted uranium. The center of gravity was located experimentally. It is located 90 millimeters (3.56 inches) f rom the rear, 70 millimeters (2.75 inches) above the bottom surf ace, and 62 millimeters (2.44 inches) from the right surface. 2-1 Revision 0 1 March 1985
.?. 3 MEGbnDiCal 219991119s Di MRLRKinlE b The outer housing of the Model AI 500 SU is fabricated from V Type 304 stainless steel. This material has a yield strength of 207 MPa (30,000 ps i). Drawings of the source capsules used in conjunction with the Model AI 500 SU are enclosed in Section 2.10. These source capsules are f abricated f rom either Type 304 or Type 304L stainless steel. 2.4 GRDRzal SLADdaKCB 191 bil Easkages 2.4.1 Cbggical acQ gglyanig Egaggigos The materials used in the construction of the Model AI 500 SU are uranium metal, stainless steel, brass, titanium, and epoxy. There will be no significant chemical or galvanic action between any of these components. The possibility of the formation of the eutectic alloy iron uranium at temperatures below the melting temperatures of the individual metals has been considered. The iron uranium eutectic alloy temperature is approximately 725 C (1337 F). However, vacuum conditions and extreme cleanliness of the surfaces are necessary to produce this alloy at this low temperature. Due to the conditions in which the shield is O mounted in the Model AI 500 SU, sufficient contact for this effect would not exist. In support of this conclusion, the following test results are presented. On 28 November 1973, a thermal test of a sample of bare depleted uranium metal was performed by Nuclear Metals, Inc., Concord, MA. The sample was placed in a ceramic crucible and inserted in a furnace preheated to 800 C (1475 F) and remained there for thirty minutes. The sample was then removed and allowed to cool. The test indicated thLt the uranium sample oxidized such that the radial dimension was reduced by 0.18 millimeters (0.007 inch). i On 25 January 1974, a subsequent test was performed by Nuclear Metals, Inc. In this test, a sample of bare depleted uranium metal was placed on a steel plate and subjected to the thermal test conditions. The test revealed no melting or alloying characteristics in the sample and the degree of oxidation was the same as experienced in the earlier test. 2-2 Pevision 0 1 March 1985 OV t
Notwithstanding these test results, there are not iron-uranium interfaces in the Model AI 500 SU. 2.4.2 E9211i22 212221s The source assembly in the Model Ai 500 SU cannot be moved to an unshielded position without movement of a holddown cap. The holddown cap is held in the engaged position by a seal wire. Access to the holddown cap requires opening of the outer cover. The outer cover is bolted to the package and the bolt is padlocked in the engaged position. Additionally, the source assembly is held in the shielded storage position by means of a lock slide which is secured by an independent key operated lock. Therefore, positive closure is maintained during transport. 2.4.3 Lifting Daylsaa The Model Ai 500 SU is designed to be lifted by its handle. The handle is attached to the package by means of handle balls at each end of the handle. A static tensile test of this handle arrangement was made. A report of this test is included in section 2.10. This test demonstrates that the lifting device can support five times the weight of the package without exceeding the yield strength of the material. 2.4.4 Tisdswa Dayists () The Model AI 500 SU can be tied down by means of the handle. An analysis of this tiedown arrangement under the load conditions of le CFR 71.4E(b) is presented in Section 2.10. This analysis demonstrates that the maximum stress generated in the handle would be less than the yield strength of the material. Therefore, we conclude that the Model AI 500 SU satisfies the tiedown condition of le CFR 71.45(b) (1). Additionally, if the handle were to fail under excessive
- load, the ability of the package to maintain its structural integrity and shielding efficiency would not be
- impaired, i
Therefore, the package tiedown design satisfies the criteria of 10 CFR 71.45 (b) (3). i 2.5 StandBxdB 101 Ty99 D EDskastR 2.5.1 Load EnsistADc2 Considering the package as a simple beam supported on both 2-3 Revision 2 8 August 1985
ends with a uniform load of five times the package weight evenly distributed along its length, the maximum stress can be computed from
- U F1 W ax =
8z where 7 max = maximum stress F
- assumed load (1448N or 325 pounds) 1
- length of beam (279mm or 11.90 inches) 3 z
- Section Modulus (76,851mm or 4.67 in')
(Ref: Machinery's Bandbook, 22nd Edition, p. 294 & 261) The load is assumed to be 1,448 newtons (325 pounds). The container is assumed to be a rectangular solid 141 milli-meters (5.56 inches) high, 124 millimeters (4.88 inches) wide, a wall thickness of 3.4 millimeters (8.135 inch) and a length of 279 millimeters (11.0 inches). 3 Consequently, the 3 section modulus of the beam is 76,051 mm (4.67 in ). Therefore, the maximum stress generated in the beam under these conditions would be 0.135 MPa (95 lb/in') which is far below the yield strength of the material. 2.5.2 ExterDal Exsssurg The Model AI 500 SU is open to the atmosphere. Thus there will be no differential pressure acting on it. The collap-O, sing pressure of the source capsule is calculated assuming 1 that the capsule is a thin wall tube with a wall thickness equal to the minimum depth of weld penetration which is 0.5 millimeter (0.020 inch). The collapsing pressure is calcu-lated from: P = 597.6 t/d - 9.556 where P: Collapsing Pressure in MPa t: Wall Thickness (E.5mm or E.02 inch) 6: Outside Diameter (6.4 mm or 0.250 inch) (Ref: Machinery's Handbook, 22nd Edition, p. 330) From this relationship, the collapsing pressure of the source capsule is calculated to be 37.1 MPa (554 8 psi). Therefore, the source capsule could withstand an external pressure of 0.17 MPa (25 psi). 2.6 E9Iral f9pd111CDS 91 TIADEP9It i 2-4 Revision 9 1 March 1985 O
2.6.1 B2c% The thermal evaluation of the Model AI 500 SO is presented in Section 3. From this evaluation, it is concluded that the Model AI 500 SU will maintain its structural integrity y and shielding effectiveness under the normal transport heat condition. 2.6.2 Cold The metals used in the manuf acture of the Model AI 590 SU can all withstand a temperature of -40'C (-40 F). The outer package housing and the primary containment are all fabri-cated f rom Type 304 stainless steel. As stated in Draft Regulatory Guide, Division 7, Task MS 144-4, austenitic stainless steels are not susceptible to brittle fracture at temperatures encountered in transport. The epoxy used in the Model AI 500 SU have an operating temperature range of -43'C to 194*C, From this data, it is concluded that the Model AI 500 SU will maintain its struc-tural integrity and shielding effectiveness under the normal transport cold condition. 2.6.3 Enduggd 212s5vz2 An external pressure test of the Model AI 500 SU was conduc-ted by Automation Industries, Inc. The device was placed in a pressure chamber and the pressure was reduced to 0.25 Q kg/cn. and u.aintained its shielding efficiency and struc-C/ tural integrity. A report of this test is presented in a letter to Mr. R. Raul f rom Mr. M. Santcro dated 4 December 1981 and included in Section 2.10. A demonstration of the ability of the source capsules to withstand an external press ~ure of 0.5 atmosphere is presented in Section 3.5.4. On the basis of these data, it is concluded that the Model AI 500 SU will maintain its structural integrity and shield-ing effectivenest under the normal transport pressure condi-tion. 2.6.4 Y1brailta. The Model AI 500 SU has been in use for more than ten years. In this period, there has been no evidence of vibration-induced failure. 2-5 Revision 0 1 March 1985 O
On the besis of this history, it is cenclud:d that the Mcdol AI 500 SU will maintain its structural integrity and shielding effectiveness under the normal transport vibration A condition. 2.6.5 k'a.tgI Eprny The water spray test was not acually performed on the Model AI 500 SU. The materials used in the construction of the Model AI 500 SU are highly water resistant. Therefore, it is concluded that the Model AI See SU will maintain its structural integrity and shielding effectiveness under the normal transport water spray condition. 2.6.6 EIng Disp A prototype Model AI 500 SU was subjected to the hypotheti-cal accident free fall condition. This is described in S ec t ion 2.7.1. On the basis of this test, it is concluded that the Model AI 500 SU will maintain its structural inte-grity and shielding effectiveness under the normal transport free drop condition. 2.6.7 CpIngI DImp Not applicable 2.6.8 EsDstIat19D ,A prototype Model AI 500 SU was subjected to a penetration test by Automation Industries. The package was impacted by the penetration bar in three different attitudes. As a result of these impacts, there was no loss of structural integrity nor reduction of shielding efficiency. A report of this test is presented in a letter to Mr. R. Rawl f rom Er. M. Santoro cated December 1981 and included in Section 2.10. On the basis of this test it is concluded that the Model AI 500 SU will maintain its structural integrity and shielding effectiveness under the normal transport penetration condi-tion. 2.6.9 CDcpIsssipD A prototype Model AI 500 SU was subjected to the compression condition. The total mass of the package is 30 kilograms 2-6 Revision 0 1 March 1985 O
(65 pounds). The maximum cross sectional area of the 2 package is 0.04 m (61.2 in - ). Thus, five times the weight of the package (1448 newtons or 325 pounds) is greater than 13.8 KPa (two pounds per square inch) times the maximum g cross sectional area (545 newtons or 123 pounds). g The package was subjected to a compressive load of 1515 newtons (340 pounds). The load was applied for a period of 24 hours. At the conclusion of this test, there was no loss of structural integrity nor reduction of shielding efficiency. A report of this test is presented in a letter i to Mr. R. Rawl f rom Mr. M. Santoro dated 4 December 1981 and on the basis of this test, it is concluded that the Model 865 will maintain its structural integrity and shielding effectiveness under the normal transport compression condi-tion. 2.7 Bypothetical bggiggog ConditipDs 2.7.1 Esse Dxgy The Model AT 500 SU was subjected to the conditions of the free drop by Automation Industries, Inc. The~ target used in this free drop test consisted of a solid concrete apron with a thicknesE of 0.2 meters (8 inches). A cteel plate with a thickness of 16 millimeters (0.63 inches) was placed in intimate contact with the concrete apron. Euring test, the package fell f rom a height of 10.3 meters (34 feet) onto the target. As a result of this test, there was nc loss of structural integrity nor loss of shielding efficiency. A report of this test by Mr. M. Santoro dated 24 July 1973 is presented in Section 2.10. On the basis of this test, it is concluded that the Model AI 500 SU will maintain its structural inte-grity and shielding effectiveness under the hypothetical free drop accident condition. 2.7.2 EyDcture At the conclusion of the free drop test, the prototype Model Ai 500 SU was twice subjected to the puncture condition by Automation Industries. The target for the puncture test was a steel billet 76 mm (3 inches) in diameter and 203 mm (8 inches) high mounted on the target used in the free drop test. 2-7 Revision 0 1 March 1985 m .L. ho +-
During this test, the packaged dropped f rom the height of one meter (40 inches) onto the billet. As a result of this test, there was no loss of structural p()s integrity nor reduction in shielding efficiency. A report of this test by Mr. M. Santoro dated 24 July 1973 is pre-sented in Section 2.10. On the basis of these tests, it is concluded that the Model AI 500 SU will maintain its struc-tural integrity and shielding effectiveness under the hypo-thetical puncture accident condition. 2.7.3 Ib2Iral At the conclusion of the f ree drop and puncture tests, the prototype Model AI 500 SO was subjected to the thermal condition by Automation Industries. The package was placed into a kerosene and fuel oil fire. The package remained there for 47 minutes. At the conclusion of the test, the fire was extinguished and the package was allowed to cool only by natural convection and radiation. No artificial cooling methods were used. As a result of this test, there was no loss of structural integrity nor reduction in shielding efficiency. A report of this test by M r. M. Santoro dated 24 July 1973 is presented in Section 2.10. On the basis of this test, it is concluded that the Mcdel AI 500 SU will maintain its struc-tural integrity and shielding effectiveness under the hypo-thetical thermal accident condition. U 2.7.4 b'a. tex 1cugxsicD Not Applicable. 2.7.5 Syczaxy 91 Datage The tests designed to induce mechanical stress (f ree drop, puncture) caused minor deformation but no reduction in structural integrity nor impairment of any safety features. The thermal test had no adverse affect on the package. As a result of these tests, there was no loss of structural integrity nor release of any contents. Prior to the conduct of these tests and subsequent to the conduct of these tests, measurements of the radiation inten-sity in the vicinity of the package were made. The results of these measurements demonstrate that there was no reduc-tion in shielding efficiency as a result of these tests. 2-8 Revision 0 1 March 1985
2.8 Spes131 EDIE The Model AI 500 SD is designed to transport Tech / Ops source capsules. These source capsules have been certified as a I i special form radioactive material under IAEA Certificate of i Competent Authority Number USA /0154/S and USA /0279/S. These i certificates are presented in Section 2.10. 1 i 2.9 Ensl BDCs Not applicable 4 O i r l 2-9 Revision 0 1 March 1985
- O
2.10 bpsendiz IAEA Certificate of Competent Authority USA /0154/S () IAEA Certificate of Competent Authority USA /0279/S Drawing 60050 Drawings SK2332-7, -8, -9, -10 i Test Report: Model AI 520 SU Holddown Arrangement Report: Analysis of Model AI 500 SU Tiedown Arrangement Letter to Mr. R. Rawl, U. S. Department of Transportation from M r. M. P. Santoro, Automation Industries, Dated 4 December 1981, describing the results of the Model 500 SU Penetration Reduced Pressure and Compression Tests. Automation Industries Test Report by Mr. M. P Santoro, dated 24 July 1973, describing the results of the Model 500 SU Free Drop, Puncture and Thermal Tests. O F 2-10 Revision 0 1 March 1985 O 1 1
O U5 Deportmen- .. s... - r.. u. ory m i e v.,. r i.t u. (m. Reseorth and ) 'V 5secpWe* lAE A CERTIFICATE OF COMPETENT AUTHORITY s Adm6nistratton i Speciot Form Rodiooetive Moterio! E~ncopsulation Certificate Number USA /Ol54/5 (Revision 4) This certifies that the encapsulated sources, as described, when loaded with the authorized rodioactive contents, have been demonstrated to meet the regulatory requirements for special form radiooctive materials os prescribed in IAEA l/ ond USA 2/ regulations for the transport of radioactive materials. 1. Source Description - The source capsules described by this certificate ore identified as the Technical Operations, Inc., Models which are described and constructed as follows: Copsule Model Approximate Size (in inches, diameter x length) 6000I .25 x.97 60004 .25 x.97 60006 Pellet, Wofer or Large .25 x.90 Wofer 68310 Pellet or Wofer .25 x.78 O 60017 .25 x.97 \\ 60018 .25 x.97 60020 .25 x.97 60021 .25 x.97 All capsules are constructed of either 304 or 304L stainless steel and conform with the following design drawings: Copsule Model Drawing Number 60001 60001 - 1, Rev. M and 60001-5 60004 60004 - 1, Rev. E and 60004 - 2 60006 Pellet 6000) - 5 and 60006 - 3 60006 Wofer 60006 - 1, Rev. H ond 60004 - 1, Rev. E 60006 Large Wofer 60006 - 1, Rev. H ond 60001 - 5, Rev. F 68310 Pellet 68310 - 9 and 68310 - 10, Rev. A 68310 Wofer 68310 - 1, Rev. F ond 68310 - 2, Rev. G 60017 60017 - 1, Rev. A and 60001 - 2 60018 60017 - 1, Rev. A and 60004 - 1, Rev. E 60020 60020 - 3 and 60001 - 5 60021 60020 - I and 60004 - 1, Rev. E II. Radioactive Contents - The authorized radioactive contents consist of metallic Iridium-192 with not more than 240 Curies in models 60001, 60004, 60006 Pellet, Wofer and Large Wofer or 120 Curies in models 60017, 60018, 60020, 60021, 68310 l Pellet and Wofer. OV 1 4
2 Certificate Number US A/0154/S, Revision 4 Ill. This certificate, unless renewed, expires December 31,1989. This certificate is issued in occordoncI with porogroph 803 of the IAE A Regulations I/ and in response to the November I,1984, petition by Technical Operations, Inc., Bu,rlington, Mossochusetts, and in consideration of the associated information therein. Cerfified by: /000nn AkwAn.9 /9M' Richard R. Rowl (Date) Chief, Rodioactive Materials Bronch Of fice of Hazardous M.ateriots Regulation Materials Tronsportation Bureau 1/ "Sof ety Series No. 6, Regulations for the Safe Transport of Radiooctive Materials, 1973 Revised Edition", published by the International Atomic Energy Agency (IAE A), Vienna, Austria. 2/ Title 49, Code of Federal Regulations, Ports 170- 178, US A. Revision 4 -incorporated new drawing nos; extended expiration date. O
j-? (Mh) m US Department .x s, ,n si,,,i s
- Of Troption wa w t on 0 C 20590 7
, IAEA CERTIFICATE OF COMPETENT AUTHORITY Administrotum Special Form Radioactive Material Encaosulation _ Certificate Number USA /0279/S Revision 0 This certifies that the encapsulated sources, as described, when loaded with the authorized radioactive contents have been demonstrated to meet the regulatory requirements for special form radioactive material as prescribed in IAEA I/ Snd USA 2] regulations for the transport of radioactive materials.
- 1. Source Descrir> tion - The sources described by this certificate are identified as Automation Industries Models 500-W8 and 500-W10 which are tungsten-inert-gas welded 316 stainless steel encapsulations which measure 0.25 inches (G.4 mm) in diameter by 0.75 inches (19 mm)in length (Al drawing 500-W8 & W10).
H. Radioactive Contents - The authorized radioactive contents of these sources consist of not more than 300 curies of Iridium-192 metal wafers. III. This certificate, unless renewed, expires April 30,1988. This certificate is issued in accordance with paragraph 803 of the IAi_ Regulations 1/, and in response to the October 19, 1983 petition by AutomE-Industries,Inc. Phoenixville, PA and in consideration of the associated informain therein. Certified by: 46bf & !M23. - Richard R. Rawl (Date) U Chief, Radioactive Branch Office of Hazardous Materials Regulation Materials Transportation Bureau 1/ " Safety Series No. 6, Regulations for the Safe Transport of Radioactive 7.laterials,1973 Revised Edition", published by the International Atomic Energy Agency (IAEA) Vienna, Austria. 2/ Title 49, Code of Federal Regulations, Part 170-178, USA. W
A600%-l R EY. CCi/L( DESCRJiArtWJ A l2- & 78 Cg,,Rc j Q f ff, y,5 f() }fa f f - 0 B 0 0-al 60006 PEMOVEDJ AppED 60GIO( 64W pgg 3yg ~C INOVM murp 600/7 i 600/83MRspSMT3 260 249 ALL CAPSULES l p 'c-7 j, eh 60004-2 {~1 j[ l h / 7 ] .i :pm
- > 685-97 REF
/ G M 'N / )GMO=IC 7 . PELLET WAFER J 6000J 600C4 y 068310 O ( d Q 9 d , w., 3, emo., q f *'7-' 3 7 '7-3 j 6oo .970 REF k 7 b/ / / ?g, ,(,ew., ywQe--, i / = / E G0020 60021 60017 6 0018 MATERIALS TECHNICAL OPERATIONS INC. '"v"- RADIATION PRODUCTS DIVISION f SURUNGTON. MA 01303 FINISH DWG TITLE ovwN
==n.... IRIDIUM SOURCE REFERENCE
- ho.= w e =x HECKED'BY y
\\ p CLASSIFICATION SIZE DWG. NO RET ) APPROVED BY A LES FRACTIONS - ( SCALE 7 :l l SHEET 2 OF J gg 7,9 .paut;.%; : o.. i=:. a i..: e. c
REY. DATE DESCmPTION _l A 4-8 M ADOED 25"r.195 DW twF, ( f l RETAIN FMRP ECGE 49 x.195 DIA 01/>M, f ,ar ffME/. P- / h 4 g -- - - 9 g I 5O 5 / t N m 800 y / x i h o -w o \\\\ n { N \\ ( f .0R0t.002 + = 4.M o ,4 jlB DRILL PT mIA O% .m = l l - BREAK COENER EXCEPT YlHERE NOTED 1 AT.# C900 A48 4Wlo ~ i MATERIALS % bee. l TYPE 716 ST. STL Tech Ops RADIATION PRODUCTS DIVISION SURUNGTON, MA 01803 6l3^ ER ~ IRIDIUM-192 CAP, HELl-ARCTAL DWG TITLE FINISH DRAWN SY y,y,s ppgg,igct,,,t w g Nk M I.@hl[O N YJU00W8 7
- ~# ~# -x CK(D BY y
3 ~/(. -h g ,,gg CLASSIFICATION SIZE DWG NO. REY. O*JC $R ROVED BY ANGLES A ./.., 4 FRACTIONS A J/g SCALE + l SHEET I OF i 37AUL0i=G CE. i=L 2804304
~ a mi wt I ocsca...im j ' H +' l 60%C G' a.i% > CHAT.fr~. gf, c i ~ 7 RETAIN 51MRP EEGE ~:Af.43.lTO DIA G%MF,.. ) .;.f i' 1] kM 2-SM A- ,is . L' ODa tudL$$5ED.;. I ..,, e ...,.e : %g,.w .. y .u..., .. a. n m c / VEoi s m W2 o; / .v... ~ / l$ S T +9'k inw5 (I l I N. I I llB DRbLl.PT =--OROt.0@ AF4 i "MO = _y
- n..
... s. ..,...7.-. 'h.7 mL b ' h.'kt [,$i, Y *$,N ^. *'. . d[;[ I f .s 1,,* tis .. w.: m..,.,. y,',' + b.:e+,. E 'f,* p J,x h 's r;e' .M* % * '. is ". %;;,e !<h. e
- s sJ ::*.
q. sjtit*.=a$.h- ',.....3 w .e ,.s -- .....:,.~s Nk W.';Q
- e; ' **<.
h . '.:;;r ~^ P .s b. _ h h ? tri L'% ; % :.F : WP: %:ivtMui.'. ? ~',9?q'~ ~, ~ Q(fls .13 ,x g' cgfQ g,.
- =
.,g K ? y,. m' DLME.9NGTON, 94A 01518 g[A2 *R 1Rl00M-l92 CAP, Hell'-AT TAL M TITLE. FIM!SH v
- 3. _ B,
f k & $hk g, $ f $$*Wf 3 ' * 'E *ff i .x s . _,ED 8' .XX a j C, /,/ p g gy C'.A! ' IFICAT60M SIZE OWG. MO. REY. p,,...'; ,, n - A SK2H2-8 4 . - ~, - - _ - imm i ~.,.
==. ' O.%.** G CG.. ser. 3:44304 j
g '..J C 9 i _h$. m m n w - li es r s L m, er 8lid! = N,_ E !o e OMS W,T M s t x s. s q 4 2 rh 5 !O I pe.ru - e88 + 4 I k."o] L h L l l-j. I i1'** 5 a i I x 3 e 8 't I l v i !'f I l 3 !m j i gg a s .gJ l !" ! lk ! sy L____J 1 - Q" / at.3 ~ wya we-g_ 4 r- -- i .L i I 6.g l l-i- t gsi i ~R '(i i i s Il l I 8 R i S I 5". ^ se y r
- -W/g97/*-*
Cup 9 f ~ ?0 9'9/ 'm MA
- -wa?.otz'---
f O 1
m m -wO 6 pq i.' p!s. '; E J9 w .M rd
- i..
- 5 4_
- m
, jf Ek; .. -,,. 3 '~ syg's.; j; Q-r jy M 5 r $ y at a :,. x : w y i,.3 i[ Yy' l i I k, et
- s. - q - p.%. -S M W= 4g m__
~ + w at q;..
- '6fgidh. h 't
$ % C c-- y e%[....$tI?.p-g4 _. , l" s.. - t. v w i/IG *bt' ..J Q i I' i , pt "2 . ~ ', [ ISM t{. -tyt'i;4.j,,wr.m egn' - t wq/4 fC f,-
- 1. :.
R ' 6 nr- ... t u 9gde 4 l1 ..;a y. p g g t.o.1 l t.~ . 3,: y ...l e Y R, a EI g 8E W inie. .w; jy g ]; .-J.. ,qq y T ,,p_ w 4-1 ?. qq j pjI.j l p. 4 I. 'llthf b - - - - -l I _ ~ - j . w.,;., ln e, . wy. . p, a. p.,m... y.4..,w,,,.. g ;,p u ya c ou,u.., , a. 1 :,,,.'.' e 'di hMQg4 w.i s 2 Mumps y %f.4> :rui;(W, pt = ~ e nq> .z. q;- a d 1 I g i B' g, s. ~ g' h, 'h3I E( e Ihl c) i I LI 4' \\f I u ' 40 9//'e g $5
- iT'* ** Ol
- F 74 g Tfdh$p h MM
.M(s'@.- d W 'I ra. - rx. l l i ,.r,=u~
r l TEST RE:C T RADIATION PRODUCTS DIVISION .I. h. Ey: Ge:r;e L'. Farsent J:hn J. Monrc I:I Dete: 21 Mer:h IEEE Suba :t: Model A! 500 SU Pa:Kage Tiedown Test e i 4 i I I A M: del AI 500 SU Type B(U) Ea:6a;e, Serial Number 570. was subje:tec to the tied:wn load standerd o' 10 CCF 71.45: D). The package was tied d:wn by means l j of cables atta:mec 1: each side of each be11 connectin; the handle t the pa:6a;e. i A f:r:e cf ter t1*e5 the wei;*t Of the pa 6a;e (E50 peancs) in the h:rt: ental l i d i e : t i c e-1r.ha:P tre se*1:le tresels end e fcrce of five t ir e5 the wel;ht of tFe ;3:6e;e ::5 p;snt: 1-the trars,erse h:rt:Ontal direct 1:n prod ce a res.! tent ": 1:: tc; f:r:c :' '2E p:.nc:. It was c ncluced that the m:st
- ese e e;;11:at;;n cf ttis f: ce was alor.; the directicn of the Ic ; a.1 of l-tre ;c:Le;t.
Inc ac t el h: ;;;-te! #: ( a;;11ec in th15 cirec t ;:n durin; t he l test.es 750 c;s-0;. Tre 3 : 0. se-ti;31 force a; plied tc the pa;6 a;e during tr;5 te:*.e: :.: ;;.rr; :" ti.(
- Ime! the wel;*t of the ;e:6a;e.
1 r 1 1 The :e:'s;e et t.:.' e ; t t : :: trege f: :et f:- :ne neu. l i# b At trc : -;. :.:' ;' t"1: telt, t*e-* wes
- fe.lvre :' er y com;;aert cf the Tee e was n: e=icen:e cf er, yleid ;f La:6 e;e :- :' tre t iec;.
e-aa;e er en. ::*::ne-* Tre e': e. It 11 ::n;1 ace: tret the pa:*0;e con witnttend the tae::.- 1;2: ; ;-. t i: -! . i t ". : e t ;ece etir; en, strete ir
- e. ets f the ylel:
j et en;t- ' tne ta .e;. i; l- [ i I I i i l' { + I t I t l i i 1 i 1 t
1 a l i O M s g 4 \\ i \\ \\ s t M 70 LBS l / / 4 / / \\ / ')M LB1 ~1 9M LB9 I n I i e i f l i 0 =.7301m l i 4 I I i I O h i _.__,..,n-.,--,,,_..--_,,_--m ~ m, _ nw
TS$i CEPCci RADIATION PRODUCTS DIVISION Ey. Ge: ;e W. Pa sens, p" / - J c h r. J. Mun-c !!I-Date: 21 Me ch 1S55
Subject:
M: del AI 500 SU Pac 6 age Lifting Test A Model Al 500 SU Type E(U) Pa:6a;e, Serial Number 572. was subjected to the li ting lead standa-d of 10 CFR 71.45( a ). The package was secured to a f platf:rr, with a mass in excess of ten times the mass of the package, by means of cables ettached ic ea:h side cf es:h ball that ccnne:ts the handle to the package. A f:-ce ir e.:ess :f te ee times the weight cf the pa:Fage (250 pounds) was e;;11er t: t*e cc:le;e handle in the se-tice directicr.. This f rce was e;;11e; f"
- t h
- o".
At the ::a:. s.:-
- ta;:
'e:*. trere wes no fallare Of er., component of the pa:la;s c" C' ins handle. I"e c .e m: ewidence cf any yleld cf an ccmponent. y
- :":..:e that the pe:+ age :an withsterd the lifting load Tr.ere' re.
ield stre.;th cf the c:nd.ti:rs u.tr:.t gene ctin; c. 3et ; r. e, cess Of the f P2te lel, b l
AUTOMATION INDUSTRIES, INC. ,/' SPERRY PRODUCTS DIVISION PO Boa 245 PHOENIXVittE.PA 19460 L (215) 933 8961 December 4, 1981 Mr. R. R. Rawl Office of Hazardous Materials Regulation Materials Transportation Bureau U.S. Department of Transportation 400 Seventh Street, S.W. Washington, D.C. 20590 Re: Application For B(U) Certification Of Two (2) Of Automation's Existing Type "B" Packages Raving Assigned Identification Numbers As Follows: USA /9006/B Model 500-SU, IR-192 Source Changer i USA /9007/B Model 520 Iriditron Exposure Device
Dear Mr. Rawl:
The above referenced packages were originally certified as Type "B" ('s packages by your office in 1973. Automation Industries has recently s,) subjected both of these packages to the basic and specific additional l test requirements for Type B(U) packages. All additional tests were performed in accordance to, and in sequential or.:er as outlined in the IAEA Safety Series No. 6, 1973 Revised Edition (as amended 1979). .I. SPECIAL NOTES AND CONDITIONS RELATING TO ADDITIONAL TESTS: A. There have been no design changes to either package such 63 size, mass, structural configuration, or shielding medium since the original Type "B" approvals were issued in 1973. B. Each package was subjected to the additional tests separately; and during each test, the test package contained the same en-capsulated source of Iridium-192. C. The contained source of Iridium-192 had a calibrated strength of 17.0 curies on September 1, 1981, and is identified by Automation's serial no. IR-14361. D. One test specimen of each package design was used throughout all of the additional test requirements. O l l L
O w (j Mr. R. R. Rawl Page - December 4, 1981 E. Each test package was surveyed for external surface radia-tion levels and radiation levels measured at one (1) meter from any external surface; both prior to, and after each test. To further insure structural and containment integ-rity, an intimate wipe test of the contained IR-192 sealed source and container "S" or "J" tube was performed both prior to and after each test. Af ter the WATER IMMERSION TEST, Sect. VII, Par. 721, the residual water after each 8 hour hydrostatic test was col-lected and the volume determined. Two (2) 10ml samples of each batch were assayed by well-counting for a 10 minute period. This procedure was to further assure the integrity of containment. After completion of all tests covering additional requirements for Type B(U) packaging, the contained source of Iridium-192, serial no. IR-14361 was further leak tested to meet the require-ments of Appendix "A" of ANSI Standard N542, Sections: A2.1.1. Wipe (Smear) Test A2.1.3. Im:rersion with Boiling Test. [mV} an internal void volume of less than 0.10 ml. NOTE: All of Automation's sealed sources of Iridium-192 have F. Considering the materials of construction, compact design con-figuration, and relatively light mass of both packages, some of the additional test (such as water spray or internal heat generation) were omitted by reasoned consideration or where con-servative and reliable engineering judgement clearly oviates the need for testing. These particular tests will be referenced in this report with the notation-- " Test Not Required". Reference to the cumulative effects of the mechanical tests and thermal test performed in 1973 for qualifying as Type "B" Pack-ages will be included in this report with the notation-- "Com-pliance Demonstrated, 1973". G. A set of photographs will be included as part of this test report to illustrate the various equipment and apparatus used in per-forming the applicable tests. H. All of the additional tests for B(U) packaging were performed during the period September 1, 1981 through September 11, 1981. CN U Q Mr. R. R. Rawl Page December 4,1981 II. _ EQUIPMENT AND INSTRUMENTS EMPLOYED A. TEST EQUIPMENT 1. Vacuum Pump Welch Duo Seal Model 1400, S/N 112839 2. Hydrostatic Pump Neptune Model HP-1, 750 PSIG Max. 3. Pressure Vessel Fabricated from 8" std. vt., sch. 40, seamless steel pipe, fitted with 300 lb. RF slip-on blind flange as removable top, and two pressure taps. Internal Dimensions: 7.981" I.D. X 14" high 4. Dead weight for compression test. Cylindrical, lead shielded, Cobalt-60 transport container. Container S/N SC-204 7-s Cross weight " Empty": 340 Lbs. (_- 5. Cylindrical Steel Bar for Penetration Test Bar diameter: 3.2 cm (1.25") Bar weight: 6.0 kg (13.25 Lb.) Bar length: 97.2 cm (38.25") Striking end: Hemisherical B. TEST INSTRUMENTS 1. Survey Meter Radiac Set, Model 68-27R S/N I-130, Calibrated 6-5-81 & 9-7-81 2. Well Counter For leak test analysis Eberline Mini Scaler Model MS-2, S/N 151 with bicron 2"X2" crystal 6 1" diam. X 1-1/2" deep cavity Bicron Model 2MW2-PQ 3. Rate Meter For calibrating source Victoreen Model 555 S/N 279 J -
O 84- / ) Mr. R. R. Rawl -/ Page December 4, 1981 4. Pressure Gauge Marshaltown #G27477 2-1/2" Dial, 0-400 PSIG Calibration: ANSI Grade B, 2% 5. Vacuum Cauge Marshaltown #G14489 2-1/2" Dial, 0-30" Hg. Vac. Calibration: ANSI Grade B, 2% 6. Various laboratory supplies such as hot plate, beakers, burettes, syringes, radiac wash, dis-tilled water, rinse bottles, etc...for leak test-ing and evaluating radioactive concentrations. C. TEST SPECIMENS 1. Model 500-SU Source Changer Type "B" Certificate No. USA /9006/B Serial No. 670 2. Model 520 Iriditron, Exposure Device Type "B" Certificate No. USA /9007/B Serial No. 831 ("') \\'s' 3. Sealed Source of Iridium-192 Encapsulation: Special Form Calibrated Strength: 17.0 Curies (9-1-81) Automation's S/N IR-14361 III. RADIATION SURVEYS OF PACKAGES A 17 curie source of Iridium-192 was inserted into the Model 500-SU source changer and also into the Model 520 Iriditron. Both packages were surveyed for surface radiation levels and for rad-iation levels measured at one (1) meter from any external surface of the package. These surveys were performed prior to subjecting the packages to the basic and specific additional tests for B(U) packaging. Results of these initial surveys also established a baseline for comparison of radiation levels and integrity of con-tainment prior to and after each sequential test. Results of these initial " baseline" surveys are tabulated below: A. Model 500-SU source changer, S/N 670 ~ Results of " baseline" radiation surveys Area Surveyed mrem /h at Surface mrem /h at 1 Meter L. Side 2.5 0.1 R. Side 11.0 0.15 Front 1.5 0.1 N Rear 10.5 0.15 b Top 2.3 0.1 Bottom 9.5 0.1 l l i f l
O [~h Mr. R. R. Rawl N-- Page December 4,1981 B. Model 520 Iriditron, S/N 831 Results of " baseline Radiation Surveys Area Surveyed mrem /h at Surface arem/h at 1 Meter L. Side 26.0 0.1 R. Side 28.0 0.15 Front (lock end) 14.0 0.1 Rear 6.0 0.1 Top 26.0 0.1 Bottom 8.0 0.1 IV.. ADDITIONAL PERFORMANCE TESTS Each package was tested separately while containing the 17 curie sealed source of Iridium-192. Each package was subjected sequen-tially to the following prescribed tests required by IAEA Safety Series #6. A. Reduced Pressure - Sec. II, Par. 221 Specimens placed in pressure vessel and chamber air pressure reduced to 0.25 kg/cm2 (3.56 F/in2 Ab.). Specimens were held this reduced pressure for a period of 3 hours. at ~. (,) 1. Evaluation---Visual examination after reduced pressure tests to containers revealed no apparent damage to co=- ponents. 2. Radiation surveys on all exterior surfaces and at I meter distance showed no significant variation from " baseline" surveys. 3. Post contamination wipe (smear) test results on both con-tainer surfaces and source capsule were less than 0.0001 micro curies /sq. cm. B. k'ater Spray Test---Sec. VII. Pars. 710 6 711 " Test Not Required" C. Free Drop Test---Sec. VII, Par. 712 " Compliance Demonstrated,1973" D. Compression Test---Sec. VII, Par. 713(a) Since the vertical projected area of the test packages are rather small, a load in excess of five (5) time the actual weight of either package was used in performing this test. (s - s 1 l \\,_ l 1 I
O ,o [b] Mr. R. R. Rawl Page Dec.e.eber 4, 1981 The Model 500-SU source changer Geighs 58 pounds. The Model 520 Iriditron weighs 40 pounds. We employed a cylindrical, lead shielded transport container weighing 340 pounds for performing the compression test. Each package was placed in its normal upright position with the base supported by a flat concrete floor. The 340 pound load was positioned on the top surface of each package, and the compressive load applied for an uninterrupted period of 24 hours. 1. Evaluation---Visual examination of each container after the 24 hour load period revealed no apparent damage to containers or components. 2. Radiation surveys on all exterior surfaces and at 1 meter distance showed no significar.t variation from " baseline" surveys. 3. Post contnination wipe (smear) test results on both con-tainer surfaces and source capsule were less than 0.0001 micro curies /sq. cm. E. Penetration Test---Sec. VII, Par. 714 Each package was subjected to the folloving penetration test. Each package was placed on flat, horizontal concrete floor. Each package received three (3) impacts from the penetrating bar. The height of free fall of the bar was one meter, mea-sured fro = the lower hemispherical end of the bar to the upper surface of the test specimen. The penetrating bar consisted of cylindrical steel rod having a 3.2 cm. (1.25") diameter, and a hemispherical striking end. The overall length of the bar was 38-1/4", and the total weight was 13-3/8 pounds. The Model 500-SU source changer was subjected to a total of three (3) impacts; one each to the following exterior surfaces: (a) Center of top surface (b) Center of right side (c) Center of rear surface The Model 520 Iriditron was subjected to a total of three (3) impacts; one each to the following exterior surfaces: (a) Center of left side (b) Center of rear end plate (c) Rear of locking mechanism l V i l O r? gs. ('/ Mr. R. R. Rawl Page December 4, 1981 1. Evaluation---Visual examination revealed that the penetration test results in little or no damage to either package. A small indentation, barely discern-ible was noted at each point of impect. There was no deformation of container surf aces, and all welds and locking devices remained intact. 2. The penetrating bar was not deformed as a result of the 6 drops. 3. Radiation surveys on all exterior surfaces of the pack-ages, and at 1 meter distance showed no significant var-intion from " baseline" surveys. 4. Post contamination wipe (smear) test results on both container surfaces and source capsule were less than 0.0001 micro curies /sq. em. F. Free Drops (I & II)---Sec. VII, Par. 719 " Compliance demonstrated, 1973" / G. Thermal Test---Sec. VII, Par. 720 \\ " Compliance demonstrated, 1973" H. k'ater Immersion Test---Sec. VII, Par. 721 Both packages were tested separately while containing the 17 curie source of Iridium-192. A pressure vessel was used in conjunction with a hydrostatic pump to exert an external water pressure of 1.5 kg/cm2 (gauge). The actual test pres-sure used for these tests was 30 PSIG maintained for a period of 18 hours. 1. Evaluation---Visual examination revealed that the water immersion test resulted in no physical damage to either package. 2. Radiation surveys on all exterior surfaces of the pack-ages, and at 1 meter distance showed no significant var-iation from " baseline" surveys. 3. Post contamination wipe (smear) test results on both l container surfaces and source capsule were less than 0.0001 micro curies /sq. em. l l l l a _7-
O . hh r~~x v i Mr. R. R. Rawl \\-- Page December 4,1981 4. The total volume of pressure vessel equals 700 cu. l l in. - 11.47 liters. Residual water after Model 500-SU source changer was removed from pressure vessel = 7.78 liters. Residual water after-Model 520 Iriditron was removed from pressure vessel = 7.99 liters. For purpose of calculations lets use 8 liters of residual water for both packages. A 10 mi sample (1/800 of total residual water) from each test package was assayed by well counting over a 10 minute period. Results of these assayes showed no activity levels above background. V. INTEGRITY OF CONTAINMINT AND SHIELDING A. Our well counting instrument is sufficiently sensitive to detect the presenge of gamma emission down to 0.005 nei over a 10 minute counting period. B. Af ter each perforniance test both peckages were evaluated for extent of non-fixed removable surface contamination. /] This was determ$ned by hand wiping a 300 sq. cm. area of (_,/ the container surface using a dry cotton wad. Results of well counting demonstrated that in no instrnce did concen-trations of non-fixed contamination exceed 0.0001 micro curies /sq. ceu C. After each performance test the contained sealed source of Iridium-192 was leak tested by using the wipe (smear) test method described in Appendix "A" of ANSI-N542, Section A2.1.1. All exterior surfaces of the capsule were wiped thoroughly with cotton pipe stem cleaners moistened with a 5% solution of radiac wash. The amount of radioactivity removed from the source before and af ter each performance test was used as an indicator in evaluating the integrity of the package in restricting the loss of radioactivescontents. In no case were results of capsule wipe tests in excess of 0.0001 micro curies. D. To further assure the packages ability to restrict loss of radioactive content, an additional leak test was performed on the contained sealed source of Iridium-192 after the packages had been subjected to the required curaulative tests. This test consisted of " Immersion with Boiling" as specified in Appendix "A" of ANSI-N542, Section A2.1.3. f3 fI
O (V) Mr. R. R. Rawl Page December 4, 1981 Immersion with boiling was accomplished by using a stand-ard radiographic exposure device which was equipp,ed with a source guide tube fitted with a perforated " screen-type" end cap which terminated into a 1000 ml beaker containing a 500 m1 solution of 5% radiac wash. This arranRement per-mitted remote handling and positioning of the source during the test. The Iridium-192 source was expo' sed and immersed into the 500 ml of solvent. The solvent.was then boiled for a period of 10 minutes. The sealed source was then re-moved and allowed to cool. The~ boiling solvent was retained. The test source was then rinsed in a 150 ml fresh solution of solvent. The rinse solvent was then added to the origi-nal boiling solvent---This operation was repeated twice, for a total of three tests, using the originil solvent for the boiling. Two 10 m1 samples of the original solvent were each assayed by well counting for a 10 minute period. Results of these assays showed no concentrations above 0.002 nei/ml of solvent. Since the total residual solvent after boiling was equal to 600 m1, then the total activity in the solvent is (0.002 nei/ml X 600 ml) equals 1.2 nei total act-ivity. s VI.
SUMMARY
AND COMMENTS A. Test results demor. strate that the two (2) packages have successfully met the basic and specific additional test requirements for Type B(U) packaging relating to: (1) Structural integrity. (2) Retention of shielding and shielding integrity. (3) Restricting loss of radioactive contents to less than: A X 10-6 per hour 2 and X 10-3 per week A2 where A2 = 20 ci. for Iridium-192. B. A set of 8 photographs are included as part of this test re-port which illustrate the various equipment and test appara-tus employed. C. Automation Industries, Inc. requests that both of the above referenced containers be certified as type B(U) packages, and that appropriate Certificates of Competent Authority be established. Sincerely, $4 sd (2 (] Michael P. Santore, (,/ Nuclear Products 12-4-81 !PS: deb Enc: (8) Photographs
$ AUTOMATION INDUSTRIES, INC. SPERRY DM840N ,o non us / \\ PDCOEMut PA 19440 cns meses ( TEST RESULTS-FOR TYPE "B" PACKACING IRIDIUM SOURCE CHANCER-SPENT URANILH TYPE AND MODEL 520 IRIDITRON EXPOSURE DEVICE In an effort to reduce transportation costs and also as an effort towards product icprovement, Automation Industries, Inc has de-signed and constructed a new Iridium Source Changer for servicing our Iridium-192 customers. Our new Source Changer will use Spent Uranium as the shielding medium. By utilizing Spent Uranium, our new changer is approxi-mately one quarter the volume and one-third the weight of our present lead shielded Changers, n e gross shipping weight of the new Sw rce Changer will be sixty (60) pounds. This reduction in size and weight renders a very cou: pact, rugged, and structurally sound design, capable of withstanding severe abuse encountered during shipcent and in field use. The container design consists of t. rectangular box, approximately 5" wide x 7" high x 11" long, fitted with a hinged cover to permit access to the internal coc;partment. De entire unit is fabricated f ro,: type 16-8 Stainless Steel sheet, #10 Gage, (0.140" thick), with all corners and seac:s continuously welded. D e Spent Uranium shield is completely encased in an all-welded leak tight compart-n ce n t. The shield is fixed in the compartment by seal welding the ( ) two (2) exit tubes through the partitioning sheet, and then potting (_/ with a high temperature solid epoxy. De unit is designed to cret the requirecents of D.O.T.-55 Specification. In essence, this new changer is a miniature version of our present lead shielded changer. All threaded connections, threaded seal caps, transfer tubes, cethod of packaging, securing and sealing are the same for both units. The procedures to be followed for effect-ing a source change in the field are also the same for both units. The same operating instructions will apply for both Source Changers. As designed, the Spent Uranium Changer is a D 0.T.-55 shipping :on-tainer; however, at this time, Automation Irdustries, Inc. would also like to qualify it as a Type "B" shipping container. In order to substantiate this qualificatior., the Spent Uranium Source Changer was subjected to the following test requirements of the International Atomic Energy Agency. Tests were performed sequentially in the order listed below: A. }iECHANICAL TEST Free Drop fl The package was dropped from a height of thirty-four (34) feet onto a flat, horizontal, 5/8 inch thick steel plate. m e July 24, 197 ) Michael P. Santoro [ 9 Prcduct Manager, Nuclear Rev. *! Dated 5-8-80 Rev. #2 Dat ed 1-27-83 s y ...u.o m eu u ,,,. 8 s. s.,.u,,..u m...,.,,,,ts,.i3. <m s l \\
(2) $ AUTOMATION INDUSTRIES, INC. manyomsioN eononto,Aweo ,s 3 n<warvia j QS 93M9ea t 't,/ Free Drop #2 The package was dropped from a height of forty (40) inches onto the upper end of a steel circular bar which was perpendicular to the concrete pad. The target surface of the circular bar was flat with its outer edges rounded off to a radius of six (6) mm. Deviations: (a) For the Free Drop fl, the 5/8" steel plate was not wet floated onto the concrete pad. However, the eight (8) inch thick concrete apron was flat and horizontal, as was the steel plate, and the contact interface was intimate. (b) For the Free Drop #2, the circular steet bar was three (3) inch diaceter in lieu of the fif teen (15) cm. diaceter called for. OBSERVATIONS: Subsequent to Drops #1 and #2, visual in-spection and radiation surveys indicate, that the container and/or containers, as presently designed, would have sustained more severe test conditions, and still maintained integrity. Results of the s drop tests showed negligible effects. f ) \\s / B. THE RMAL TE ST The container and/or containers were suspended by wire rope from an "A" frame, centered over a 66 inch by 66 inch fuel pan, having five (5) inch sides. The container and/or containers were positioned approximately twelve (12) inches above the surface of the fuel. The fuel consisted of a 50/50 percent mixture of Kerosene and #2 Fuel 011. Tota' time of exposure to flace was fourty-seven (47) minutes. This exceeded the required test period by saventeen (17) minutes, since we were unable to extir.grish the flame by use of three (3) conventional CO2 extin-guishe rs. Two (2) local Fire Companies arrived with suitable foam generating equipment to blanket the fla me. The container and/or containers were allowed to cool naturally for a period of three (3) hours. l Deviations: Total time of exposure to flame was fourty-seven (47) minutes, due to difficulty encountered in attempting to extinguish the fire at the thirty (30) minute mark. M M July 24, 1973 Michael P. Santoro Product Manager, Nuclear l l q l l
(3) $ AUTOMATION INDUSTRIES, INC. SPERRY DMSiON _x concase ( ) E" v For ecological reasons and also potential fire haz-ards, the same fire was used to expose two (2) dif-ferent containers sinultaneously. (he Spent Uranium Source Changer and Our mdel 520 Iridieron Exposure Device.) An attempt to monitor the flame temperature, using a Weed Model 8000 Tenperature Indicator with platinum resistance probe (0 to 1600 *F) failed, due to a malfunction in the instrument or a short in the probe ele men t. OBSERVATIONS: Af ter the three (3) hour cooling period, both contain-ers were inspected visually for structural damage, and also monitored for any radiation hazards. Were were no apparent high surface radiation levels. Both con-tainers exhibited bulged or " pregnant" attitudes, due to extrecely high internal pressures resulting from the decocposition of the trapped epoxy potting resins at the elevated temperatures. The internal gas pres-sures had to be exceedingly high in order to permanently set a convex bow on all surfaces of the containment shells (#10 Gage 0.140 inch thick, type 304 Stainless Steel Plate). The Spent Uranium Source Changer showed no structural failure, nor any loss of shielding integrity, as a fm ( } result of the fire test. \\.s The Model 520 Iriditron.:id spring about 507, of the weld seac on the bottom portion of the rear end plate, (Lock Box End). This occurred at approximately the fourty (40) minute elapsed tice mark, while the firemen were preparing to blanket the fire with foam. The weld failure was clearly evidenced by a cuffled explosion, followed by a rapid release of expanding gases or epoxy vapors. Close up inspection showed that the lower seguent of the rear end plate had pulled away from the shell tube, forming an angle of approxic.ately 15'off the perpen-dicular. Accordingly, this rotation of the rear end plate caused the lockbox to be cocked upward approxi-cately 15' off the horizontal. One end of each hold down tube on either side of the Ndel 520 base, had separated from the end plates. These separations are not relevant to containment of shielding integrity, however, they do attest to the tremendous forces that were built up and released, in order to cause these weld failures. / / "M. MAbu ' July 24, 1973 Michael P. Santoro P-et Manager, Nuclear ? \\ \\vl
(4) AUTOMATION INDUSTRIES, INC. SPERRY DMSiON ('~ _,) E m Te 1 to som as n/ It was also noted that the leather handles, and alumi-num Radiation Warning Tags and labels, had coupletely disintegrated. Stainless Steel Nameplates and chemi-cally etched engravings remained legible. On the mdel 520, the aluminum Source Identification Plate was 607. melted away, and the remaining portion not legible. C. COVTAINMENT AND SHIELDING IhTECRITY D2 ring each test, each container was loaded with a sealed source of Iridium-192 of following strengths: 1. SPENT URANIUM SOURCE CHANGER Drop Tests 1 and 2, 34 Curies of Iridium-192 (See Chart "A ") 30 Minute Fire Test. 30.7 Curies of Iridium-192 (See Chart "C") 2. MODEL 520 IRIDITRON (EXPOSURE DEVICE) Drop Tests 1 and 2, 24 Curies of Iridium-192 (See Chart "B") 30 Minute Fire Test, 21.5 Curies of Iridium-192 (See Chart "D") p ( ) Radiation Surveys were performed on both containers, U prior to and af ter being subjected to each test. Dose rates were measured and recorded for surface levels; at six (6) inches from external surface, and at one (1) meter from the external surface. Se e Cha rt s "A" t o "D" for radiation survey results. (a) he Spent Uranium Source Changer did not exhibit in any significant change in dose rates af ter each and cu::ulative tests. (b) D e Model 520 Iriditron did not exhibit any significant change in dose rates af ter Drop Tests 1 and 2. However, af ter the Thermal Test, some of the surface and six (6) inch dose rates increased, while others directly opposite in location decreased (see Chart "D"). De cuculative average of dose rates did not shif t more than 15L his could be considered negligible. This change in radia-tion dose levels can be attributed partly to the complete loss of epoxy resin, when the rear end plate seal weld ruptured and reliev-ed the internal pressure. It was calculated 3 /' July 24, 1973 c Michael P. Santoro Product Manager, Nuclear u-
(5) AUTOMATION INDUSTRIES, INC. s SPERRY DMSiON t'% ro son us I( J PHOENUn%L PA Wee 0 f Ots tauvea v that the epoxy offered approximately 17. of the shielding value. D e major cause of shift in dose levels was caused when the lockbox cocked upwards. Bis motion of the lockbox pulled the Iridium-192 source capsule out of center position in the shield; approximately 3/16" off center. De source pigtail is positioned and fixed into the shield by means of the lock prongs and limiting orifice when the unit is in locked position. Accordingly, then the locking mechanism rotated upward, the source pigtail was displaced an equal' amount. This explains why some dose read-ings increased, while others decreased. Since the Model 520 Shield is overdesigned, with resulting good safety factor; and a 1/2" safe dwell position in the center of the "S" tube, the source capsule can be translated at least 1/4" to eigher side of the theoretical center before appreciable changes in radiation dose levels are noticed. This feature was designed into the unit. D. PHOTOCRAPHS ne following photographs numbered one (1) through s T twenty-three (23), illus trate the set-up, progress, C,/ and effects of tests on the containers:
- 1- - - - - - - - - - - - - - - - - - 30 Foo t Free Drop
- 2------------------ Spe n t Uranium Change r -
Prior To Test
- 3.................. Ndel 520 Iridieron -
Prior To Test
- 4,
- 5-------------- Nde l 520 Iridieron -
Af ter 3a Foot Free Drop
- 6------------------ Spen t Uranium Change r -
After 34 Foot Free Drop
- 7------------------ Ndel 52 0 And Sou rce Change r -
After All &chanical Tests
- S,
- 9-------------- Ndel 520 Iriditron -
Before And Af ter Drop Onto Circular Pin
- 10, ill------------ Source Change r -
Before And After Drop Onto Circular Pin
- 12, fl3------------Close Up Of Fuel Pan -
Prior To Thermal Test
- 14, #15, #16-------Progress Of Bermal Test
- 17, #18------------Source ChanSer And Ndel 520 -
Af ter Thermal Test IJote Source Pigtail Connectors Protruding From Lockboxes. Note Seam Weld Rupture On Ndel 510 Iriditron. )# July 24, 1973 Michael P. Santoro Product Nnager, Nuclear n v I l
(6) $ AUTOMATION INDUSTRIES, INC. SPERRY DMSION Po tom 345 PMotNUMLJ, PA tree 0 / OnSi F314*e4 \\ / s ~
- 19-----------------Side View Of N del 520 -
Af ter Thermal Test Note Cocked Position Of lockbox
- 2 0, #21------------Radiation Surveys
- 22 f2 3------------ Radia tion Survey s E.
INTEGRITY OT SOURCE CAPSULE (ENCAPSUIATION) After coupletion of all tests, both source capsules were leak twsted to determine whether there was any leakage of radioactive contents. Both leak test re-suits were negative with respect to leakage. Source Serial Number IR-6964, contained in Ndel 520 Iriditron. Leak Tested on June 6, 1973 After Fire Test Recovable Contamination: Less than 0.001 micro curies Source Serial Number IR-7056, contained in Spent Uranium Source Changer. leak Tested on June 6, 1973 After Fire Test Removable Contamination: Less than 0.001 micro curies Visual inspection of the two (2) Source Pigtails when inspected under magnification while viewing through our Hot-Cell viewing window, indicated that there was no mechanical damage imparted to n either capsule assembly as result of tests. ( I ( F. PICOMMENDATIONS Due to the severity of the 'Ihermal Test, (011 Fire), we would suggest that anyone performing this test, do so in a very isolated area, removed f rom any flam-mable equipcent or buildings. It is also recommended that trained professional fire-fighting personnel and equipment, be on hand to terminate the test, and for obvious safety reasons. Ihe heat intensity of this test is so overwhelming, that it is impossible to approach the flame with conventional hand held fire extinguishers, when atten:pting to extinguish the flame after the thirty (30) minute exposure. C. CONCLUSION It is our opinion that both of these containers satis-factorily met the Type "B" test requitecents of The International Atomic Energy Agency, and that they be certified as such by assignment of individual Certifi-cation N rks as issued by the U.S. Department Of Trans-portation, (D.O.T.). We desire that this certification 9-dlI-July 24, 1973 Michael P. Santoro Product Nnager, Nuclear (, \\ ,J
T-(7) $ AUTOMATION INDUSTRIES, INC. SPEMRY DMSON p s eononus. N _,) T5'" or permit be acceptable for both domestic and export shipments. Since the Model 520 Iriditron is an Exposure Device, used in Industrial Radiography, and the Spent Uranium Source Changer is a shipping Container for transport-ing new replacement sources to our customers, and the returning of decayed sources to our Phoenixville faci-lity for ultimate disposal, it is M that this type "B" certification will not require that our docestic customers register with the D.O.T. to enable authorized receipt, use, or transshipcent of these containers. (They are D.O.T. 55 Spec. containers, and we do not feel that our domestic customers should be burdened with additional registration, simply be-cause we tested and proved that the containers will withstand the more rigorous tests of Type "B" packaging. ) H. SPECIAL FORM PATERIAL (a) The Spent Uranium Source Changer and the Model 520 Iriditron, will be used only as shielded containers for the isotope Iridium-192 in solid metallic form. The wafers of Iridiuc-192 are encapsulated into stainless steel capsules using a 1770*F silver braze, (Eutectic Welding Alloys Coc:pany, f1807), (p) for the sealing process. The sealed sources are decontaminated and leak tested prior to insertion into the -hielding units. (b) To date we have distributed over 7400 Iridium-192 Sealed Source Capsules of this design to licensed recipients. (c) The isotope Iridiun-192 in solid metallic fom, is an noble metal and meets all the require-ments of melting point, sublimation, percussion friability, low solubility or dissolution, and chemical stability tests, as outlined in the International Atomic Energy Agency regulations. Since we encapsulate no wafers of metallic Iridium-192 which have any dimension less than
- 0. 5 cs::, the radioactive material in itself is Special Form.
I. REQUEST FOR APPROVALS (a) We request that the Spent Uranium Source Changer be certified as a Type "B" package for shipping Special Fom, Sealed Sources of Iridium-192, up to, but not exceeding, 300 Curies. Specific Activity Range: 300 To 400 Curies / gram
- N
.I July 24, 197 Michael P. Santoro Product Manager, Nuclear p h v l l
(8) $ AUTOMATION INDUSTRIES, INC. SPEARY DfVISION Po son las PHOemerviut PA ledeo Dm** /,1 %s'l \\ (b) We request that the Ndel $20 Iriditron be certified as a Type "B" package for shipping Special Form, Sealed Sources of Iridium-192, up to, but not ex-ceeding,120 Curies. Specific Activity Range: 300 To 400 Curies / gram. (c) Ve request that our Iridium-192 Isotope be certified as Special Form Shipment and/or Special Form Haterial. ~ July 24, 1973 e Michael P. Santoro Product Manager, Nuclear R n 1910N #1. APPENDIX "A" (ADDID 5-8-83) AD.7!!!OVi DROP TEST PERFORMED TO MODEL $20 SHIELD TO ins *M THAT FORtt OT ITACT 00 t*kREE TO MOST VL'LNERABLE PAPT OT THE DEVICE. (a) Date of Test: April 2, 1975 (b) Descriptien of Test 30 ft. f ree drop cnto unvielding target consisting of e inch thick flat steel pl. ate. (c) Orientation of Device: A gay wire was espleved to maintain proper orientation to assure tnat ma x imura damage occurred to the locking mechaniss and protruding seal plug connector. ( ]/ [ (d) Test Speciment The $20 shield was the same unit which had previously been ) sutjected to sequential drcp. puncture, and fire exposure when qualifying the 'w unit for Type "B" Packaging. RI51*iT5 6 OBSERVATIONS (a) After lapact: The locking mechanism remained locked---The prntruding seal flus connector was slightly deformed---And the guy wire still saintained the 520 shiel in a vertical attitude. (b) Af ter removing guy wire, deformed seal plus connector bas temoved--- There was te evidence cf any damage to the source rigtail connector---And the source pigtail assembly was still retained in the proper locked. store / position. (c) Ce ne l u s i e n : Results of this test clearly desenstrates the inherent stability cf tne Adel 320 shield and that the device would withstand tests of this severit?. p 6/ew ' May 8,1980. Michael P. $sntoro General Manager, Aclear Products. /3 / i 1 l
(9) $ AUTOMATION INDUSTRIES, INC. N SPERRY DIVISION i to son 2as ,"y PHOParvtt PA weeo ass. eusses REVISION #2. APPENDIX "B" (ADDED l-27-83) 1. SCOPEt TO DoctHENT RESL*LTS OF MECHANICAL TESTS PERFORMED ON THE C0w3!KATION PACKAGE CONSISTING OF AUTO uTION INDUSTRIES MODEL 500-st' IRIDIL%I92 SOURCE CHANGER (CONTAINwENT VESSEL) VMEN ENCASED WITHIN A STEEL DRUM OVERPACK. A. PACKAGE DESCRIPTION: The complete package assembly consists of Automation Industries Model 500-SU 1ridium-192 Source changer (Containment Vessel) completely encased within a #18 gage steel drum which measures 15-1/8" outside diameter and a total height of 13-3/4". The drum is fitted with a top opening lid which is secured with a cleap ring and seal bolt. Two (2) close fitting molded hair-packs are fitted within the drum to receive and main-tain the containment vessel in a fixed position during transport. (See Automation's Dwg. No. D-3005U-0P for complete specifications.) B. CROSS WETCir? 0F COMPLETE PACKACE (CONTAINwtNT VESSEL PLUS DDLH OVERIACK): 80 Pounds. C. MODEL N'JWEER OF CCNFLETE PACKACE tbdel 5005U-OP. D. TYTE AND FORM OT RAD 10ACTTVE COV'ENT! Metallic wafers of Iridiu-- 192 as sealed sources which meet the require'sents of sp :ial. ort encapsulation; and depleted uranium shield casting of the 500-St. E. MAXIMLH OCANTITY OF RAD 10ACTIVF CONTENT PER PACKAF.Et 300 Curies cf Iridiur-192, plus 39 pounds of depleted uranium (shield cast-ing of the 300-50 containment vessel). ./m ) II. PERFORMANCE TESTINC - CENERAL FOR ALL PACKACINC - Sl'IPART C s v A. 71.3!(c)(1) LIPTINC DEVICEst The complete package assembiv was supported by the two (2) lifting handles and a static load of 260 pounds was distributed over the top surf ace of the package. Load-ing was maintained for a period of 5 minutes. At completion of test, visual inspection revealed no evidence of systeri f ailure or deformation to any of the supporting components that would indi-cate stresses in excess of the yield strength. (See attached photograph #1). E.
- 71. 31(c)(4) LirTINC DEVICES. EJCES$1VE LOAD (Test performed by t ne testing laboratories of W.E. Coleman Company. Philadelphia, PA).
The package was fixtured onto a tensile testing pedine and an up-ward vertical force was applied to one of the lif tist handles and gradually increased until failure. The handle grip loop failed at 2 M pounds. Failure consisted of the grip loop separating and pull-ing out of the handle mounting bracket. Visual inspection revealed that the excessive load to the handle did not generate excessive stress to the drum housing nor impair the containment or shielding properties of the package. (See attached photogrank J'). [ 70 Jan. 27, 19' M.P. Santoro, Mgr, Engr., Eclear Products. n t
(10) g AUTOMATION INDUSTRIES, INC. I PC sOR24s SPERRY DMSION ' m PHottaKvtt, FA tsaeC (2Lla e334%i C. 71.31(d)(1) TIE-DOWN DEVICES: A static force applied through the center of gravity of the package having a vertical component equal to two (2) times the weight of the package (160 pounds), a hort-tontal component equal to ten (10) times the weight of the package (800 pounds), and a horisontal component in the transverse direc-tion equal to five (5) times the weight of the package (400 pounds). Since we cannot control the orientation of the package in relation to the direction of vehicle travel, we have selected the centerline passing through the two (2) handles as the direction of the 800 pound horizontal vector. The resultant of these components is equal to a static f orce of 910 pounds rotated through 27 degrees of f the centerline passing through the handles, and having an angle of de-clination equal to 10 degrees. (This test was performed by the test-ing laboratories of W.B. Coleman Company, Philadelphia, PA). The package was fixtured onto a tensile testing machine with steel banding straps securely tightened to the hold-down loops to main-tain proper orientation of the package and also support the pack-age during the test. A one (1) inch diameter rae was attached to the crosshead to transfer and direct the 910 pound force in line with the center of gravity of the package. This load was maintained for five (5) ainutes. At full loading (910 pounds) there was no failure in the tie-down syst em---The tie-down straps remained intact as did the handle loops. Further inspection revealed that the test load did net generate ex-cessive stress to the drum body nor to the tie-down system. (See attached photograph #3). D. 71.3 tid)(3) TIE-DOWN DTV!CES, EXCES$tVE LOAD: (Test performed by the testing laboratort s of W.b. Coleman Company. Philadelphia, PA). The package was fixtured onto the tensile testing machina so that loading would be applied to the tie-down loop at approximately 45 /' s degrees f rom the horizontal when the package vauld be in its normal ( ) upright shipping attitude. Leading was gradually increased until (_ failure. Tne tie-down handle loop f ailed at 1385 pounds. Failure consisted of the handle loop eeparating and pulling out of the han-dle sounting bracket. Visual inspection revealed that excessive loading to the tie-down device te point of failure did not generate excessive stress to the drum housing not tapair the containeent or shielding properties of the packaFe. (See attached photograph f 6). E. 71.32fa) LOA 3 PESISTANCE: (Test performed by the testing labora-tories of W.B. Coleman Company, Philadelphia, PA). The package was tested as a simple beam supported at its ends along both its vert 1-cal axis and hertsental axis. A static load of 400 pounds was applied neraal to a.d uniformly distributed alor.g the largth of its upper surface. lor both tests the lead was maintained f or a duration of five (S) minutes. Visual examination at completion of tests showed no evidence that any surf ace of the package was stressed to its yield point. (See attached photograph F5). s--- /- / // M fMy,_ Jan. 27, 195) M M.P. Santoro, Mgr. Engt., Nuclear Product s. n m.
O 4 s ( ! ! $ AUTOMATION INDUSTRIES, INC. SPERRY DIVISION m. eo aos 349 i ~ pHornermr, pa, waac tats enasei s III. PERFORRNCE TESTING = FOR MORMA1. CONDITIONS OF TRANSPORT " APPENDIX "A" A. APPENDIX "A-6" FREE DROP The package was subjected to three (3) f ree drops through a distance of four (4) f eet onto a flat hort-sontal surface (blacktop roadway). The points of Lapact were to the top clasping ring, the bottom rLa and to the side well of the d rum. These tests imparted very little damage to the drum other than re-noval of paint and slight surface scratches to the metal at points of impact. (See attached photograph #6). B. APPEWDIX "A-7" CORNER DROPT The package was subjected to one (1) ffJE Corner drops 0010 each quarter of the top clasping ring, and onto each quarter of bottom ria (total of eight drops). The sur-f ace of tapact was a flat horisontal blacktop roadway. Again, damage was very minimal consisting of paint removal and slight surface scratches to the metal at peints of impact. (See attached photograph #7). C. APPEMDIX "A-8". PEKITRATION: The package was supported by a flat horirontal blacktop roadway. The package was subjected to t wo (2) impacts from the penetrating bar. One (1) drop onto the center of the top lid, and the second drop onto the center of the drum's bot-tot with the drum resting in the inverted pos!*1ct. The penetrating bar consisted of a cylindrical stee: rod having a 1-1/4" diameter, and a hemispherical striking end. The overall length of the bar was 38-1/4". and the total weight was 13-3/8 pound s. The height of free fall of the bar was 40 inches seasured f rom the lower hemispherical end cf the bar to the upper surf ace of the test package, m [ } Visual examinattor revealed that the penetration drops resulted in very little damage to the two (2) surfaces of impact. Damage to both surfaces at point of impa.t consisted of a hee 1 spherical de-pression approstaately 3/4" in diameter and 1/6" deep. There was no piercing or tearing of either test surface. (See attached photo-graph #8). D. APPENDIX "A-9". C3HPRE5910N A static Iced of 460 pounds was equally distributed over the top surface of the drue while the drue was in its normal upright t rans po r t position and supported by a flat hort-rental concrete floor slab. The compressive load was mair.tained continuously for a period of 24 hours. Visual examinations af ter testing revealed no evidence of any damaFe to the package resulting from this loading nor any indications of deformation to any of supporting components which would indicate stresses in excess of the yield strength. (See attached photograph
- 9).
44 Jan. 27, 1983 M.F. Santoro, Mgr. Engr., Nuclear Products. ,a
(12) h AUTOMATION INDUSTRIES, INC. SPERRY DIVISION ( mos.OEbd PO b 's 4 vait, PA waac De ena*as IV. PERFORMANCE TESTINC - HTPOTHETICAL ACCIDENT COC1110NS "APPTNDIX-P" A. APPENDIX "B-1", FRIE DROP TMROUCH 30 FEET: A sealed source of IR-192, serial number 15202, having a calibrated strength of 8.5 curies on January 12, 1983 was loaded into and secured within a Model SOD-SU Source Changer, serial number $U-644 This will be designated as the containment vessel. The containment vessel was then inserted into the drum overpack and properly positioned and secured within the cavity of the molded hair-packs. The drum was then closed with the top removable lid and secured and locked by the clamp ring and seal bolt assemb1v. This complete assembly will be designated as the Model 50050-Op overpack assembly, and will have a gross shipping weight of 8C po und s. Prior to drop, the package was surveyed for external surface radiation levels and radiation levels sensured at three (3) feet f rom all external surf aces of the package. Results of these surveys indicated the highest levels recorded on anv en-terior surface of the drum was 1.9 MR/HR and 0.1 KR/HR when mea-sured at a distance of three (3) feet from any enterior surface. The package was holsted to the roof top of a 34 f oot higt build-ing, and allowed to drop onto a flat horizontal essentially un-yielding blacktop roadway. lapact occurred at the lowe' side surf ace of the drue between the area of the lower chine bead and the bottom rim. Essentially it approximated a bottom corner drop. The damage to the package was sintaal considering the amount cf energy absorbed. The structural soundness of the package was fN, unchanged and the integrity of closures and containment remained ( l intact. The only physical damage consisted of flattening of the bottoe ria of the drum at surface of impact and a slight perfora-x_- tion of the side wall also wl.hin the area of tapact. The perfora-tion resembled a right angle slit having a width of 3/32" and u9-equal legs of I-1/2" 1 1". The perforation was actually the in-print of the rear lower corner of the containment vessel which compressed the hair pack at the instant of tapact with suffielent force to locally shear the side wall of the drum by the combined actions of shear, elongation, and forging. Radiation surveys on all esterior surf aces of the package, and at a distance of 3 feet frra all exterior surfaces demonstrated that there was no increase la eurface radiation levels of t r ans po r t inden resulting f rom the f ree drop test. The highest surface radiation level remained at 1.8 KR/HD as did the transport inden at 0.1 MR/HR. Upon removal of the seal F :lt, clasping ring, top lid, and upper f air-pack sold f rom the ps.c kage, we noted that containment vessel was att11 properly positioned by the orientation bracket and pro-perly nested within the 1;eer hair-pack cavity. This demonstrated t ha t the hair-packs have an escellent capacity for energy absorb-tion, combined with good elasticity and resiliency. Emaninatinn of the containment vessel revealed no damage to any of enterior surfaces, seal wires or closures. (see attached photograph #10). //# Jan. 27, 1969 = M.P. Santoro, Lngr. Ngt., Nuclear Products. ,n.
(13) $ AU10MATION INDUSTRIES, INC. ,m SPERRY DMSION / i e o. som 145 kx _- ' pe0DaNvs,4 PA 19440 mis,ess.e es B. APPENDIX "B-2" PUNCTURE The package was subjected to four (4) drops through a distance of 40 inches measured from the lowest surf ace of the package to the top of a cylindrical alid steel bar which was mounted vertically on a flat horizontal unytelding sur-face. The bar was 6 inches in diameter, 8 inches in length, with a flat horisontal top surf ace whose edge was rounded to a 1/4" radius. The four (4) drops were so directed so that impacts would occur to the following surf aces of the package: Center of top lid, center of botton, aid-point of side with drus falling horisontal-ly, and onto the seal bolt and locking lugs of the clamp ring assembly. Visual examinations after testieg indicated that damage to the package resulting from these drops were very minimalg consist-ing of very slight crescent shaped indentations to the flat sur-f aces of drum lid and bottos. (See attached photograph #11). V. S N.ARY AND COMwtNTS: A. Test resalta demonstrate that the combination containment vessel and drum overpack assembly, Automation Industries, Inc. Ndel 5005U-OP has successfully met the test requirements for both normal and accident conditioes of transport relating tot (1) Structural integrity (2) Retention of shielding and shielding intearity (3) Restricting loss of any radioactive centent 5. The above radioactive saterial packases will continue to be de- [m\\ signed and fatricated in accordance te Automation Industries' ( ') Quality Assurance Program, NRC Docket ho. 71-0264, approved Octoter 9, 1979. C. All tests covered by Revision #2. Appendin "F" cf this report were conducted during the period of January 4 through January 21, 1953. D. Automation Industries, Inc. requests that the combination con-tsinment vessel and drum overpack assestly, Model $005U-OP be certified as a Type "B(U)" package fer transporting sealed sources of special-fort, Iridium-192 up to a maximum of 300 curies per package, and that the appropriate certificates cf competent aathorities be established. M Jan. 27, 16-Michael P. Santoro, Mgr. Engt., Nuclear Products l 'h .sd
3.0 Ibaxsal Evalu211sn 3.3 Discuss 19D () The Model AI 500 SU is a completely passive thermal device and has no mechanical cooling system nor relief valves. All cooling of the package is through f ree convection and radiation. The heat source is 12e curies of iridiur.-192. The corresponding decay heat generation rate is 1.83 watts. 4 3.2 Susanzy ni Zhazani Excysztiss 91 Batszials The melting temperatures of the metals used in the con-struction of the Model AI 500 SU ares Brass 939*C (17 86 'F) Uranium 1133*C (2870'F) Steel 1345'C (2453* F) Tungsten 3370*C (60988F) i Titanium 1820*C (3308'F) l j l The epoxy used in this device has an operating temperature range of -43 C to 104 C (-45 F to 220 F). 3.3 TecbDical 29tcificatiDDs 91 29g99DtDts i Not applicable 1 3.4 Scstal CcDCitigDs of 1xacgypit 3.4.1 Ib2Iral Esdsl s The heat source in the Model AI 500 SU is a maximum of 120 curies of iridium-192. Iridium-192 decays with a total energy liberation of 1.45 MeV per disintegration or 8.58 milliwat ts per curie. Assuming all the decay energy is transformed into heat, the heat genera:.on rate for the 120 curies of iridium-192 would be 1.03 watts. Tc demonstrate compliance with the requirements of le CFR 71.43 (g) and paragraph 230 of I AEA Saf ety Series No. 6, a separate analysis is presented in Section 3.6. The thermal model employed is described in that analysis. To demonstrate compliance with the requirements of paragraph 240 of IAEA Safety Series No. 6 f or Type B(U) packaging, a separate analysis is presented in Section 3.6. The thermal model employed is described in that analysis. 3-1 Revision 9 17 November 1983 9 i . _ ~ _..
3.4.2 Eazicgg Tcgp3xatyzca l The maximum temperatures encountered under normal conditions of transport will have no adverse effect on the ' O structural integrity or shielding efficiency of the package. As presented in Section 3.6, the maximum tempera-ture in the shade would not exceed 43*C (119'F) and the maximum temperature when insolated would not exceed 64 C (146*F). 3.4.3 51Dimus TarpsIatuIsa The minimum normal operating temperature of the Model AI 5 0 0 SU is -4 0'C (-4 0'F). This temperature will have no adverse effect on the structural integrity or shielding efficiency of the package. 3.4.4 Ea21sur InteIDal PIssasIss Normal operating conditions will generate negligible internal pressures. Any pressure generated is signifi-cantly below that which would be generated during the hypothetical thermal accident condition, which is shown to result in no reducticn in structural integrity or shielding efficiency. 3.4.5 Enzity Tbsical 25L22222 The maximum temperatures which will occur during normal transport are sufficiently low to assure that thermal j gradients will cause no significant thermal stresses. i 3.4.6 E2D1DatiDD DL EDGhngt 22119158DC2 MDdtz E91531 CCDQitiDDR DL TIRDEGD1% l The normal transport thermal condition will have no adverse ef fect on the structural integrity or shielding ef ficiency of the package. The applicable conditions of IAEA Saf ety Series No. 6 for Type B(U) packages are shown to be satisfied by the Model A1 500 SU. 3.5.0 ByGDLbstical Tbt1En1 bCCidRDL EynluatiDD 3.5.1 Tb2IEal EDd21 A prototype Model AI 500 SU package was subjected to the hypothetical thermal accident condition by Automation Industries Inc. 4 3-2 Revision 0 1 March 1985 i O l t. - - ~_-.
5 3.5.2 fachass EsDdliisDs and ED211sDEsDi The prototype Model AI 500 SU package which was subjected p to the hypothetical thermal accident condition had ( previously been subjected to f ree drop test and puncture test. The package had suffered minor structural deformation during these mechanical tests, but suffered no reduction in structural integrity or shielding efficiency. 3.5.3 Rackass Zss2ssalutts During the hypothetical thermal accident test, the package was placed into a kerosene and fuel oil fire. The package remained there for 47 minutes. The possibility of the formation of an iron-uranium eutectic allow was addressed in Section 2.4.1 where it was concluded that the formation of the alloy was not a likely possibility. There was no indication of any melting or alloy formation as a result of this thermal test. 3.5.4 Eazigur IniszDal PresspIss i The maximum internal pressure generated during the thermal test is described in the Automation Industries Test Report by Mr. M. Santoro, dated 24 July 1973 and presented in Section 2.10. In Sectier. 3.6.3, an analysis of the source capsule, which O,' s serves as the primary containment, under the thermal test condition is presented. This analysis demonstrates that the maximum internal gas pressur e at 80C*C would be 373 kPe (54 psi). The critical location for failure is the source Capsule weld. The analysis shows that an internal pressure of 373 kPa (54 psi) wculd generate a maximum stress of 1.96 MPa (2E4 psi). At E7 0 *C (16 0 0'F), the yield strength of Type 304 stainless steci is 69 MPa (10,000 psi). Therefore, if the source capsule were to reach a temperature cf 800*c, the maximum stress in the capsule would be only 31 of the yield strength of the material. 3.5.5 Enzitys Zbssgal Sizesses There were no significant thermal stresses generated during the thermal test. A description is presented in the Automation Industries Test Report by Mr. M. Santoro dated July 1973 and presented in Section 2.10. 3-3 Revision 0 1 March 1985 O
3.5.6 ExaluatiCD CL Rackagt 221191CnDCt As a result of the hypothetical thermal accident test, there was no significant deformation or damage. There was (' no impairment of any design or safety features. There was no damage to the locking assembly or package closure. There was no release of the package contents. A shielding efficiency test was performed at the conclusion of the thermal test. This shielding efficiency test demonstrated that there was no reduction in shielding efficiency as a result of the thermal test condition. A report of the thermal test by Automation Industries' Mr. M. Santoro dates 24 July 1973 is presented in Section 2.10. O 3-4 Revision 9 1 March 1985 O
l 1 3.6.0 8S93D413 3 { 3.6.1 Model AI 500 SU Type B(U) Thermal Analysis: le CFR 71.4 3 (g) and paragraph 230 of IAEA Safety Series No. 6 ] 3.6.2 Model AI 500 SU Type B(U) Thermal Analysis: Paragraph 240 j of IAEA Safety Series No. 6 i j 3.6.3 Iridium-192 Source Capsule Thermal Analysis I 4 I l i i i l l ) i !!O i i i i 1 4 i I l i l i i l i 3-5 Revision 0 2 1 March 1985 j i i i 1 ? j i 4 --n,. .n- .n~,-.- ,,.n,. e,-n,-n,- m.-,,, _ n _ m.,,,,,n
3.6.1 M: dol AI 500 SU Typ3 B(U) Thorcal Anclysis if CFR71.43 (g) and paragraph 230 of f IAEA Safety Series No. 6 f This analysis demonstrates that the maximum surface temperature of the Model AI 500 SU will not exceed 50' C v with the package in the shade and an ambient temperature of 38'C. To assure conservatism, the following assumptions are used: (a) The entire decay heat (1.03 watts) is deposited in the exterior surfaces of the package. (b) The interior of the package is perfectly insu-lated and heat transfer occurs only f rom the exterior surface to the environment. (c) Because each face of the package eclipses a different solid angle, it is assumed that twenty-five percent of the total heat i s deposited in the smallest face. (d) The only heat transfer mechanism is free convection. Using these assumptions, the maximum wall temperature fcund from q = h A (T - T,) wherc q = Heat depccited per unit time in t interest (0.26 watts) h = Free convection heat transfer coef ficlu.i for air = 1. 3 2 t,T j\\ watt /m o L *C A = Area cf the face of interest (0.0175m' ) T,= Eoximun temperature of the surface of the package l T,= Ambient Temperature (38*C) From this relationship, the maximum temperature of the su r f ace is 4 2.6*C. This satisfies the requirement of 10 CFR 71.43 (g) and paragraph 230 of IAEA Safety Series No. 6. 3-6 Revisicn 0 1 March 1985 I .c_
3.6.2 Medal AI 500 SU Typ2 B(U) Tharac1 Anslysis paragraph 240 of IAEA Safety Series No. 6 i This analysis demonstrates that the maximum surface p) temperature of the Model AI 500 SU will not exceed 82*C s, l when the package is in an ambient temperature of 38'C and is insolated in accordance with le CFR 71.71(c)(1) and Table III of IAEA Safety Series No. 6. The calculational model consists of taking a steady state heat balance over the surface of the package. In order to assure conservatism, the following assumptions are used. (a) The package is insolated at the rate of 775 W/m' (800 cal /cm' -12 hr) on the top surf ace,194 W/m' (200 cal /cm' -12 hr) on the side surf aces and no insolation on the bottom surface. J (b) The decay heat load is added to the solar heat load (c) The package has an unpainted stainless steel surface. The solar absorptivity is assumed to be C.9. The solar emissivity is assumed to 0.8. (d) The package is assumed to undergo free convection from the sides and top, and undergo radiation f ron the sides, top and bottom. The inside faces are considered perfectly insulated so there is no j conduction into the package. The faces are consi- \\s-dered to be suf ficiently thin that no temperature gradients exist in the faces. (c) The package is approximated as a rectangular Fara11cle piped 279mm (11 in) long,141 mm (5.56 in) wide, and 124 mm (4.88 in) high transported 1 i on the bottom. The surf ace area of the top and bo t tom a r e 0.0 3 9 3 m'. The total surf ace area of t h e s id e s i s 0.10 4 n '. s The xaxinum surf ace temperature is computed f rom a steady sta'.e heat balance relationship: Nin " Nout 3-7 Revision 0 1 March 1985 V - ~ +, .mr ~ - - - - - - ,r- - -,,,- - - - - -, _ -, - - 7 ,---o--
,g
---w-wn,,,
The heat load applied to the package is 1n " # 9 +9 9 [} s d where x: solar absorptivity (0.9) q, : solar heat load (50.63 watts) gg: decay heat load G.03 watts) l The heat dissipation is expressed as i 9
- 9 gout e
r where gj convective heat transfer q, : radiative heat transfer The convective heat transfer is (hA) + (hA) q = ~ sides w a where h : convective heat transfer coefficient As area of the surface of interest q T, Temperature of the surface T : Ambient Temperature (3 8*C) The radiative heat transfer is q = cr C A ( T -T ) r j where o's StefanBoltzmann Constant (5.669 x 10 -8W/ m' Y) E: Emissivity (0.8) Interation of this relationship yields a maximum wall temperature of 63.3 C which satisfies the requirements of paragraph 240 cf IAEA Safety Series No. 6. 3-8 Revision 8 1 March 1985 i O I 1
3.6.3 Model AI 500 SU Type B(U) Source Capsule Thermal Analysis Paragraph 238 of IAEA Safety Series No. 61973 This analysis demonstrates that.the pressure inside the source capsule used in conjunction with the Model AI 500 SU, when subjected to the hypothetical thermal accident condition, does not exceed the pressure which corresponds to the minimum yield strength at the thermal test temperature. The source capsule is fabricated from stainless steel, either Type 304 or 304L. The outside diameter of the capsule is 6.35 mm (0.250 inch). The source capsule is seal welded. The minimum weld penetration is 0.5 mm (0.02 inch). Under conditions of internal pressure, the critical location for failure is this weld. The internal volume of the source capsule contains only iridium metal (as a solid) and air. It is assumed at the time of loading the entrapped air is at standard temperature and pressure (208C and 100 kPa). This is a conservative assumption because, during the welding process, the internal air is heated, causing some of the air mass to escape before the capsule is sealed. When the welded capsule returns to ambient temperature, the internal pressure would be somewhat reduced. Under the conditions of paragraph 238 of IAEA Safety Series Q No. 6, it is assumed that the capsule could reach a temper-V ature of 800*C (1475 F). Using the ideal gas law and requiring the air to occupy a constant volume, the internal gas pressure could reach 373 kPa (54 psi). The capsule is assumed to be a thin walled cylindrical pressure vessel with the wall thickness equal to the depth cf weld penetration. The maximum 1cngitudinal stress is calculated from: pap l 01 A j = where v : Longitudinal Stress 3g: Stress Area p: Pressure Pressure Area Ap : From this relationship, the maximum longitudinal stress is calculated to be 900 kPa (129 psi). 3-9 Revision 0 1 March 1985 O
i The hoop stress is calculated fror. i 2a LL = Pdi Q n where c : Hoop Stress 3 i t: Length of the Cylinder t : Thicknessof the Cylinder (0.5 mm ore.02 inch) From this relationship, the hoop stress is calculated to be 1.96 MPa (284 psi). 0 At a temperature of 879 C (1688 F), the yield strength of Type 304 stainless steel is 69 MPa (18,000 psi). Therefore, under the conditions of paragraph 238 of IAEA Safety Series No. 6, the stress generated is less than 3% of the yield strength of the material. 4 l O a i i l 3-10 ' Revision 0 1 March 1985 lO
4.0 C9DhalDEgDL 4.1.0 CDDiniDESD1 EDMDdaIY 4.1.1 CDDLalDEgDL Mg&stl The containment system for the Model AI 500 SU is the radioactive source capsule as described in Section 1.2.3 of this application. This source capsule is certified as special form radioactive material in IAEA Certificate of Competent Authority Number USA /0279/S or USA /0154/S. 4.1.2 CDD%alDERDL ERDRLEntiDDR There are no penetrations of the containment. 4.1.3 Egals aDC Egids The containment is seal welded by a tungsten inert gas welding process which is described in Tech / Ops Standard Source Encapsulation Procedure presented in Section 7.4. The Itinumum weld penetration is 0.5 mm (0.02 inc h). 4.1.4 C19 suis Not applicable. 4.2.0 ERGui1952DLE 191 591Enl CDDditlDDE Di TERD2p91% 4.2.1 Eglgang gi Eadi9a91kyg Eatgxial The source capsules used in conjunctivn with the Model AI 500 SU have satisfied the requirements for special form ra61oactive material as prescribed in IE CFR 71.77 and IAEA Safety Series No. 6. There will be no release of radioactive material under the normal conditions of transport. 4.2.2 Ext 229112atiDD si %bt C9DhalDERDL Nssnel Pressurization of the source capsules under the conditions of the hypothetical thermal accident was demonstrated to generate stresses well below the yield strangth of the capsule material as described in Section 3.6.3. Therefore, the containment will withstand the pressure variations of normal transport. l 4-1 Revision 0 1 March 1985 l
4.2.3 C991DDL CQDLLEiDatiDD Not applicable. () 4.2.4 C991ADL L9EE Not applicable. 4.3 C9DLBiDERDL BRQDLERERDLR 191 kb2 BX99tbRhiCR1 b991dRDL l 29Ddik19D 4.3.1 EinsisD Gas 2194y91s Not applicable. 4.3.2 BR1gast Di C9DLSDh2 The hypothetical accident conditions of le CFR 71.73 will result in no loss of package containment. This conclusion is based on information presented in Sections 2.7.1, 2.7. 2, 2.7.3, 2.7.4, and 3.5. i O 1 l l I 4-2 Revision 0 1 March 1985 O
5.0 Shielding Eyaly3119D 5.1 Discussico and Essnits The principle shielding of the Model AI 500 SU is the uranium shield assembly. The mass of the uranium shield is 18 kilograms (39 pounds). A shielding efficiency test of a Model AI 500 SU was made. The package contained le6 curies of iridium-192. A report of this test is presented in Section 5.5. Extrapolation of these data to a capacity of 120 curies of iridium-192 is presented in Table 5.1. Since the Model AI See SU contains ~ no neutron source, the gamma dose rates are the total does rates which are presented. As shown in Table 5.1, the maximum dose rates are below the regulatory requirements. Table 5,1 SMEEnzy DL Ea%iE95 DDDe EateE DElbx At Surface At One Meter from Surface TDs Eide 291%95 19; Eids D9519m 1 164 172 189 1.1
- 1. 3 1.1 5.2 Scurcs EpscificatiDD 5.2.1 gaEEa Egyrge The gamma source it iridium-192 in a sealed capsule as special forn radioactive material in quantities up to 120 curies.
5.2.2 EggtIso Spurse Not applicable. 5.3 Ecdel Eggsification l Not applicable. 5.4 Sbisiding Eyaluation A shielding ef ficiency test of a Model AI 500 SU containing 106 curies of iridium-192 was perf ormed. The results of i 5-1 Revision 9 1 March 1985 O 1 1 6 _ _ - _.. _. _. _ ~.. _.. _ _ _. _. _... _.. - _ _...
i l this test, which are presented in Section 5.5, demonstrate that the does rates surrounding this package are within the regulatory limits. i 1 ] i b l 1 1 i I i l t i i 4 i i e 4 i l-I t i I i i i t l l i l i l i ( [ i l 5-2 Revision 8 l 1 F. arch 1985 l l 1 b \\ l i f f I
-..- - _-.~.- - - - ~.- -...-. 1 5.5 Appendix t 5.5.1 Test Report: Shielding Efficiency Test Model A1500 SU Serial Number 688 j I 4 I i i t l l 1 I 1 J i I I i i 1 i G i ( t l f I i 5-3 Revision 0 l 1 March 1985 i
TEST REPORT RADIATION PRODUCTS DIVISION BY: John J. Munro III DATE: 15 February 1985
SUBJECT:
Model AI 500 SU Shielding Efficiency Test On 19 October 1984 Model AI See SU serial number 688 was subjected to a shielding efficiency test. The package contained source assembly Model A424-9 serial number 6319 with an activity of 106 curies of iridium-192. The package tested was prepared as for transport including installation of the outer package cover. I The test consisted of measuring the radiation intensity in the vicinity of the package using a small remote probe survey instru-ment. The instrument used in this test was an AN/PDR-27(J). The radiation detector has an active diameter of 6.4 mm and an active leng th o f 11.1 mm. The detector is installed in a housing with a diameter of 15.9 mm. The instrument was most recently calibrated on 5 August 1983. The first phase of the test consisted of measuring the radiation intensity at the surf ace of the package. A slow scan survey was made over the entire surface of the package with the detector [m housing in contact with the surface. The maximun radiation inten-sity indicated on each surf ace was recorded. This measured value was corrected for the surf ace intensity by multiplying the measured result by the square of the ratio of source-to-detector axis dis-tance te source-to-surface distance. This result is presented in the following tabic. The second phase of the tr.st consisted of measuring the radiation intensity at a distance of one meter from the surface of the package. A slow scan survey was made adjacent to the entire sur-face of the package with the detector axis located one meter from the package surface. The maximum radiation intensity indicated at one meter f rom each surf ace was recorded and is presented in the following table. This test demonstrated that the radiation intensities associated with the Model AI 500 SU, when extrapolated to a capacity of 120 curies of iridium-192 are within the regulatory limits as specified in 10 CFR 71.47,10 CFR 34.21 and I AEA Saf ety Series No. 6. 5-4 Revision 0 1 March 1985 I
_ _ _ = RADIATION PROFILE MODEL AI 500 SU SERIAL 688 () 19 October 1984 1 I i Containing Source Assembly Model A424-9 Serial No. 6319 Activity of 106 Curies of Iridium-192 1 Maximum Dose Rates (mR/hr) 1 l At Surface At One Meter From Surface Tc 145 1.0 Front Side 123 1.0 i Right Side 152 1.0 Rear Side 44 1.0 Left Side 89 1.0 Q Bottom 167 1.0 d (s) J Eeasurements made with AN/PDR-27(J) survey instrumert Eerial number 7930 calibrated 1 August 1984 j i 1 i i 5-5 Revision 0 l 1 March 1985 ,lO t - ~. ~,. -. - - -. -, -,,,. - - - -. - - - - -. - - -,.--.--.__-_..n..-,,---------
n .a 6.C grigiggligy gyg3ygg39g Not applicable. 1 l 5 f l I 1 I l t -1 I r l 1 \\\\ 6-1 Revision 0 l 1 Earch 1985 .i t l l l l
7.0 Opezaking Exocsdysgs 7.1 219G26y12 LDL LDadiDg Lb2 Enckage The procedure for fabricating the special form source capsule is presented in Section 7.4.1. The procedure for loading the source assemblies into the package is also included in Section 7.4.1. 7.2 Exogsburg 191 DDigading kbg Rackage The procedure for unloading the package is presented in Section 7.4.2. 4 7.3 ELRSDEntiDD DL a ERChkst LDL ZLaDn991% The procedure for preparation of a package fo'r transport is included in the Model AI 500 SU Instruction M a n u'a l presented in Section 7.4.2. !O l i 7-1 Revision 0 r 1 March 1985 O
. _. - ~.. _ - _ _.. _ _ _.... _ _ _., _ _ i i 7.4 Appendlz i 7.4.1 Procedure for Encapsulation of Sealed Sources 7.4.2 Model AI 500 SU Sourc'e Changer Operation Manual i N i i I i i e l I, I \\ i i i 4 i I l l I l I 7-2 Revision 1 9 19 April 1985 t G .n._,,,, ,n.,. ,..___,_.._,,,n.,,,,,.. e., __.._,.n...-.-,..r. ,,,,._,__-..n,__
7.4.1 Procedure for Encapsulation of Sealed Sources /~' RADIATION SAFETY MANUAL \\ Part B - In Plant Operations Section 2 ENCAPSULATION OF SEALED SOURCES A. Personnel Reauirements Only an' individual qualified as a Radiological Technician shall perform the operations associated with the encapsulation of sealed sources. A second Radiological Technician must be available in the building when these operations are being performed. B. General Aguirements
- 1. In the Burlington, MA facility, a loading cell shall be used for the encapsulation of sealed sources and repackaging of sealed sources.
The maximum amount and form of radioactive material which may be handled in the loading cell is specified below: Radioisotope Form Maximum Activity Iridium-192 Solid Metallic 2000 cur' Cobalt-60 Solid Metallic or O sealed sources 1 r-Cesium-137 Sealed Sources only 100 cut., Ytterbium-169 Sealed Sources only 100 curies Tantalum-182 Sealed Metallic or 100 curies Solid Carbide Limits for any other radioisotopes or forms shall be specified by the Radiation Safety Committee.
- 2. In the Pho'enixville, PA facility, the general purpose hot cell shall be used for the encapsulation of sealed sources and repackaging of sealed sources.
The maximum amount and form of radioactive material which may be handled in the cell is specified below: Radioisotone Esim Maximum Activity Iridium-192 Solid Metallic 20,900 curies Cobalt-60 Solid Metallic 1 curie Cobalt-60 Sealed Sources 300 curies Cesium-137 Sealed Sources 200 curies Ytterbium-169 Sealed Sources 100 curies Tantalum-182 Solid Metallic or 100 curies Solid Carbide Limits for other radioisotopes or forms shall be specified by the Radiation Safety Committee. j 7-3 Revision 3
- 3. The loading and general purpose hot cells are designed to be operated at less than atmospheric pressurc.
The exhaust blower should not be turned of f during the operation or at any time that radioactive material is in the cell. (~})
- 4. Unencapsulated radioactive material 'shall not be stored in these cells when the cell is unattended.
Material may only be stored inside these cells in welded capsules or screw top capsules. When radioactive material is stored in these cells, a radioactive material tag identifying the types, quantities, locations and storage dates of all such material shall be attached to the manipulator or to the cell body adjacent to the window.
- 5. When any "through the wall" tool is removed, the opening shall be closed with the plug provided.
All tools shall be decontaminated whenever they are removed from the cell.
- 6. Each individual performing this operation must wear a film badge and pocket dosimeter at waist level and a second film badge and pocket dosimeter in the vicinity of the head.
All operations must be monitored with a calibrated and operational radiation survey meter. C. Precaratory Procedure
- 1. Record the names and initial pocket dosimeter readings for the personnel performing the loading operation on the Loading Log
[__ Sheet.
- 2. Check the cell lights for proper operation.
Check the cell manipulators both visually and operationally. Assure that all cell ports are plugged.
- 3. Assure that the exhaust system is operational.
Record the manometer reading on the Loading Log Sheet. If the manometer reading is less than 0.5 inch or greater than 2.0 inches of water, the filter must be changed.
- 4. Assure that the air sampling system is operational and that sample filters are in place.
- 5. Perform the preoperational contamination survey as indicated on the Loading Log Sheet.
Record the results on the Loading Log Sheet.
- 6. Perform the encapsulation procedure omitting the insertion of any activity.
Examine this dummy capsule weld. If this weld is acceptable, preparation of active capsules may proceed. If the weld is not acceptable, the condition responsible for this unacceptable wel6 must be corrected prior to proceeding. This step must also must performed each time the welding electrode is changed. O() B.2.2. Revision 4 21 March 1984 l I 1
~ D. Encapsulation Procedure fgi Burlinoton, MA' Facility
- 1. Prior to.use, assemble-and visually inspect the two capsule components to assure the weld zone does not exhibit any
[' misalignment and/or separation. Defective capsules shall be 1 rejected.
- 2. Degrease capsule components in the Ultrasonic Bath, using isopropyl alcohol as degreasing agent, for a period of 30 minutes.
Dry the capsule components at 100' C for a minimum of 20 minutes. i
- 3. Insert capsule components into' hot cell with the posting bar.
i
- 4. Place capsule bottom in weld positioning device.
Withdraw the posting bar.
- 5. Move the drawer bar of the source transfer container into the loading cell.
Open the screw top capsule. l
- 6. Withdraw the proper amount of activity f rom the screw top cap-sule and place it in the capsule bottom.
A brass rivet must be j used with wafers to prevent contamination of weld zone. 1'
- 7. Assure that all unused radioactive material is remover from the loading cell by installing it in the screw top capsule and withdrawing the drawer bar of the source transfer container f rom the cell.
- 8. Remove the rivet (if applicable).
{
- 9. Assemble the capsule components.
- 10. Weld adhering to the written welding procedure for the capsule t
i being welded. + )
- 11. Visually inspect the weld.
An acceptable weld must be continuous without cratering, cracks or evidence of blow out. If the weld is defective, the capsule must be cleaned and rewelded to acceptable conditions or disposed aof as radioactive waste.
- 12. Check the capsule in the height gauge.to be sure that the weld i
is at the center of the capsule. I
- 13. Wipe the exterior of the capsule with a flannel patch wetted with EDTA solution or equivalent.
l
- 14. Count the patch with the scaler counting system.
The patch must show no more than.005 microcurie of contamination. If the i patch shows more than.005 microcurie, the capsule must be cleaned and rewiped. If the rewipe patch still shows more than l 0.005aof contamination, steps.10 through 14 must be repeated. ,c-B.2.3 Revision 4 21 March 1984 ~
- 15. Vacuur bubble test the capsele.
Place the welded capsule in a glass vial containing isopropyl alcohol. Apply a vacuun of 15 in Hg(Gauge). Any visual detection of bubbles will indicate a 7s leaking source. If the scarce is determined to be leaking, (' ') place the source in a dry vacuum vial and boil of f the residual alcohol. Reveld the capsule; repeat _ steps 10 through 15.
- 16. Transfer the welded source capsule to the sealed source section of the loading cell.
- 17. For wire mounted source capsules, transfer the capsule to the swaging fixture.
Insert the wire and connector assembly and swage. Hydraulic pressure should not be less than 1250 nor more than 1500 pounds. For source holder mounted source capsules, transfer the capsule to the appropriate source holder loading fixture. Insert the source capsule into the source holder. Screw the source holder together and install the roll pin. Check to assure that the pin does not protrude on either side.
- 18. Apply the tensile test to assembly between the capsule and connector by applying proof load of 100 lbs.
Extension under the load shall not exceed 0.05 inch. If the extension exceeds' O.05 inch, the source must be disposed of as radioactive waste.
- 19. Assure that the cell tunnel door is closed.
Position the source in the exit port of the loading cell. Use the remote control to insert the source into the ion chamber and position the source O. for maxinum response. Record the meter reading. Compute the activity in curies and fill out a temporary source tag.
- 20. Again using remote control, eject the source from cell into source changer through the tube gauze wipe test fixture.
Monitor the radiation level as the source changer shielded door is opened. Remove the tube gauze and count with scaler counting system. This assay must show no more than 0.005 microcurie. If contamination is in excess of this level, the source is leaking and shall be rejected.
- 21. At the end of the -day's operations, perform the post-operational contamination survey as indicated on the Loading Log Sheet.
Record the results on thc Loading Log Sheet.
- 22. Record the final pocket dosimeter readings for the personnel performing the loading operation on the Loading Log Sheet.
- 23. Record the daily Air Sample results on the Loading Log Sheet.
B.2.4 Revision 4 Q 21 March 1984 l V l l
F. Encapsulation ProctdnII 121 Phoenixville. EL Facility
- 1. Prior to use, arsemble and visually inspect the two capsule components to assure the weld zone does not exhibit any
[3 misalignment and/or separation. Defective capsules shall be rejected. N
- 2. Degrease capsule components in the Ultrasonic Bath, using isopropyl alcohol as degreasing agent, for a period of 30 minutes.
Dry the capsule components at 100* C for a minimum of 20 minutes.
- 3. Insert capsule components into hot cell with the posting bar.
- 4. Place capsule bottom in weld positioning device.
Withdraw the posting bar.
- 5. Remove a storage rod from the storage pit in the cell floor.
Remove the threaded end cap f rom the storage rod and remove the screw top capsule. Open the screw top capsule.
- 6. Withdraw the proper amount of activity f rom the screw top capsule and place it in the welded capsule bottom.
A brass rivet murt be used with wafers to prevent contamination of the weld zone.
- 7. Assure that all unused radioactive material is removed f rom the hot cell by installing it into the screw top capsule.
Close the screw top capsule and place it into the threaded end cap of the 1 storage rod. Peinstall the end cap onto the storage rod. ("'/ Replace the storage rod into the storage pit in the cell floor. \\s,
- 8. Remove the rivet (if applicable).
- 9. Assemble the capsule components.
- 10. Weld adhering to the written welding procedure for the capsule being welded.
i
- 11. Visually inspect the weld.
An acceptable wcld must be continuous without cratering, cracks or evidence of blow out. If the weld is defective, the capsule must be cleaned and rewelded to acceptable conditions or disposed of as radioactive waste.
- 12. Check the capsule in the height gauge to be sure that the weld is at the center of the capsule.
- 13. Wipe the exterior of the capsule with a flannel patch wetted with EDTA solution or equivalent.
B.2.5 Revision 4 7s 6 1 21 March 1984 V l
14 Count the patch with the scalor counting system. The patch must show no not e than.005 mict ocurie of contamination. If the patch shows more than.005 microcurie, the capsule must bc c) cned and rewiped. If the rewipe patch still shows more than (,w) 0.005 of contamination, steps 10 through 14 must be repeated.
- 15. Vacuum bubble test the capsule.
Place the welded capsule in a glass vial containing isopropyl alcohol. Apply a vacuum of 15 in Hg(Gauge). Any visual detection of bubbles will indicate a leaking source. If the source is determined to be leaking, place the source in a dry vacuum vial and boil of f the residual alcohol. Reweld the capsule; repeat steps le through 15.
- 16. Transfer the welded source capsule to the sealed source section of the hot cell.
- 17. For wire mounted source capsules, transfer the capsule to the swaging fixture.
Insert the wire and connector assembly and swage. Hydraulic pressure should not be less than 1250 nor more than 1500 pounds. For source holder mounted source capsules, transfer the capsule to the appropriate source holder loading fixture. Insert the source capsule into the source holder. Screw the source holder together and install the roll pin. Check to assure that the pin does not protrude on either side.
- 18. Apply the tensile test to assembly between the capsule and connector by applying proof load of 100 lbs.
Extension under \\ the load shall not exceed 0.05 inch. If the extension exceeds 0.05 inch, the source must be disposed of as radioactive waste.
- 19. Assure that the cell tunnel 6oor is closed.
Position the source in the exit port of the loading cell. Use the remote control to insert the source into the ion chamber and position the source for maximum response. Record the meter reading. Compute the activity in curies and fill out a temporary source tag,
- 20. Again using remote control, eject the source from cell into source changer through the tube gauze wipe test fixture.
Monitor the radiation level as the source changer shielded door is opened. Remove the tube gauze and count with scaler - i counting system. This assay must show no more than 0.005 microcurie. If contamination is in excess of this level, the source is leaking and shall be rejected.
- 21. At the end of the day's operations, perform the post-operational contamination survey as indicated on the Loading Log Sheet.
Record the results on the Loading Log Sheet. i
- 22. Record the final pocket dosimeter readings for the personnel performing the loading operation on the Loading Log Sheet.
- 23. Fecord the daily Air Sample results on the Loading Los Sheet.
/"' I B.2.6 Revision 4 ( q l 21 March 1984
Tech / Ops, Inc. TechDps Radiation Products Dndseon 40 North Avenue 7.4.2 MODEL AI 500 SU Durhngton, Massachusetts 01803 fqw. phone (su) m.acco SOURCE CHANGER \\ } OPERATION MANUAL NOTICE This device is used as a radiographic source changer and Type B (U) transport package for Tech / Ops, Inc. radioactive sources listed in this manual. The uggr should become thorouchly familiar with.the instruction manual before attempting operation .of the eauioment. In order to use this equipment to perform source changes within the United States, the user must be specifically licensed to do so. Application for a license should be filed on Form NRC-313R with the appropriate U.S. Nuclear Regulatory Commission Regional Office listed in Appendix D of 10 CPR 20 or with the appropriate agreement state office. Prior to initial use of the source changer as a transport package, the user in the United States must register his name, license number and package identification number with: Director I-) Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555 The user must have in his possession a copy of USNRC certificate of Compliance Number 9006 issued for this package. Prior to the first export shipment of this source changer f rom the United States, the user must also register his identity with: Office of Hazardous Materials Regulation Materials Transportation Bureau U. S. Department of Transportation Washington, DC 20590 The user must have in his possession a copy of International Atomic Energy Agency Certificate of Competent Authority Number USA /9006/B(U)T issued for this source changer. Users of this equipment outside the United States must comply with the regulatory, licensing and transportation rules and regulations as they apply in their respective countries, o t i N) 7-9 Revision 1 -- 19 April 1985
e. ( ) General LJ The AI Model 500 SU source changer is used primarily for the transfer of encapsulated radioactive sources into radiographic exposure devices. The source changer is designed to contain the radioactive sources during transport and to permit the field exchange of sources. The source changer is five inches (127 mm) wide, six inches (152 mm) high and eleven inches (279 mm) long. The total weight of the source changer is 60 pounds (27 kg). The source changer contains 39 pounds (18 kg) of depleted uranium as shielding. The source changer is approved as a Type B(U) transport package under USNRC Certificate of Compliance Number 9006 and IAEA Certificate of Competent Authority Number USA /9006/B(U)T. The capacity of the source changer is 120 curies of iridium-192 as one of the source assemblies listed in Table 1. Shipment Data An envelope accompanies each shipment and contains a source certificate with decay data and leak test certification, a source identification plate f or attachment to the user's radiographic exposure device, return shipping labels, tamper proof seals and {') an instruction manual. As Radiation Safety Considerations Pursuant to USNRC and agreement state regulations, all personnel present during radiographic and source changing operations are required to wear a direct reading pocket dosimeter and either a film badge or a thermoluminescent dosimeter (TLD). The pocket dosimeter must be techarged at the start of each shift. The operator should f requently check the pocket dosimeter reading throughout the shift. Dosimeter readings must be recorded at the end of each shift. Records of the initial and final readings of the pocket dosimeter must be kept for inspection by the USNRC. In the event that a person's pocket dosimeter is found to be off scale, that person must stop all work with radiation immediately. His film badge (or TLD) must be sent in immediately for processing, and he must not reenter a restricted area until it has been determined that he received less than the maximum allowed occupational exposure as defined in 10 CPR Part 20.101. Personnel performing source changing operations should also have a calibrated and operable radiation survey meter capable of measuring from 2mR/hr to at least 1000 mF./hr to determine ,n radiation levels when performing these operations. ) Areas in which source changing is performed must be identified. If a permanent radiographic installation is used, it must have the appropriate personnel access control devices as defined in 10 1 2
1 CFR 20.203. Otherwise, certain areas must be established as follows: Access to the Restricted Area must be controlled. A Restricted Area is defined in 10 CFR 20.10 5 a s the area where an individual could receive an exposure in excess of two milliroentgens in any one hour, or 100 milliroentgens in seven consecutive days or 500 milliroentgens in one year. The Restricted Area should also be posted with signs reading " Caution (or Danger) - Radiation Area." Signs reading " Caution (or Danger) - High Radiation Area" should be posted around the perimeter where an individual could receive an exposure in excess of 100 milliroentgens in any one hour. The radiographer or radiographer's assistant must guard against unauthorized entrance into these areas at all times. No personnel should be allowed into the restricted area without a direct reading pocket dosineter and either a film badge or TLD. Receiot.gf Radioactive Material The consignee of a package of radioactive material must make arrangements to receive the package when it is delivered. If the package is to be picked up at the carrier's terminal, 10 CFR Part c 20,205 requires that this be done expeditiously upon notification {) of its arrival. Upon receipt, survey the source changer with a survey meter as soon as possible, preferably at the time of pickup and no more than three hours later if it was received during working hours, or no more than 18 hours later if it was received af ter normal working hours. Radiation levels should not exceed 200 milliroentgens per hour at the surface of the source changer nor 10 milliroentgens per hour at a distance of three feet f rom the surface. Actual radiation levels should be recorded on the receiving report. If the radiation levels exceed these limits, the container should be secured in a Restricted Area, and the appropriate personnel notified. All compcnents should be inspected for physical damage. The radioisotope, activity, model number and serial number of the source and the package model number and serial number should be recorded. Operation 1. Locate the source changer and the radiographic exposure device in a restricted area. Arrange them so that they can ( - be connected by the source guide tube e x t c.n s i on which accompaniec the source changer. 2. Locate the control unit to the radiographic exposure device as far away as possible from the exposure device and preferably behind radiation shielding. 3
3. Unlock the source changer and open the cover. Remove thc envelope containing the documentation and remove the source guide tube extension. 4. Connect the drive cable to the source assembly in the exposure device and connect the control unit to the exposure devie in accordance with the manufacturer's instructions and the company's operating and emergency procedures. 5. Connect the guide tube extension to the radiographic exposure device and to the fitting of the source changer over the empty tube. Raise the lock slide to the OPEK position. 6. Assure no unauthorized personnel are in the restricted area. At the exposure device controls, crank the source assembly rapidly from the exposure device to the source changer. Observe the survey meter during this operation. The radiation intensity should greatly increase as the source iE first exposed, decrease slightly as the soruce moves through the guide tube and reduce to background when the source enters the source changer. 7. Approach the exposure device with a survey meter; survey the exposure device on all sides, survey the guide tube and survey the source changer on all sides to assure the source has been properly transferred and stored. The radiation level should be less than 200 mR/hr and at the surface of O the source changer and less than le mR/hr at one meter fror the surface of the source changer. Whilemaintainingpositiveforwardforcel 8. Move the lock slide to the LOCK positicn (down). Engage the key operated lock. on the drive cable and source
- assembly, disconnect the source guide tube extension from the source changer and expose the drive cable to source assembly connection.
Disconnect the drive cable from the source assembly. Install the holddown cap over the source assembly. 9. Remove the holddown cap from the other source assembly. Connect the drive cable to the source assembly. Connect the guide tube extension to the source changer fitting. Unlock the key operated lock and raise the lock slide to the OPEK position. le. Assure no unauthorized personnel are in the restricted area. At the exposure device controls, crank the source assembly rapidly from the source changer to the exposure device. 7-13 Revision 2 8 August 1985 1
a Observe the survey meter during this operation. Thc radiation intensity should greatly increase as the source is O' first exposed, increase slightly as the source moves through the guice tube and decrease to background as the source assembly enters the exposure device. 11. Approach the exposure device with the survey
- meter, survey the exposure device on all sides, survey the length of the guide
- tube, and survey the source changer on all sides to assure the source has been properly transferred to its storage position in the exposure device.
Radiation levels should be less than 200 mR/hr at the surface and less than 10 mR/hr at one meter from the surface of the exposure device and the source changer. 12. Lock the exposure device. Move the lock slide to the LOCE position. Remove the guide tube extension from the source changer and exposure device and install it in the compartment of the source changer. 13. Affix the identification plate of the new source to the exposure device. Place the identification plate for the olc source in the source changer. 14. Assure that the proper holddown cap is installed over the source in the source changer (see Table 1). Seal wire the cap in place. Assure that the key operated locks are engaged. 15. Close the source changer cover and seal wire and lock the cover in place. ShipD9D% 9L EbbiDBC%iss 5919C2 1. Assure that the source assembly is secured in the proper storage position and the source changer is locked. Assure that the soruce changer cover is sealwired with a tamperproof seal. 2. If the source changer is to be packaged ina crate or other outer packaging, the outer packaging must be strong enough to withstand the normal conditions of transport. These requirements are outlined in le CFR 71.71. The source changer should be put in the outer package with sufficient blocking to prevent shifting during transportation. 7-14 Revision 2 8 August 1985 0
i a 3. Survey the package with a survey meter at the surface and at a distance of one meter from the surface to determine the proper radioactive shipping labels to be applied to the O package as required by 49 CFR Part 172.403. The radiation exposure limits for each shipping label are given in figure 1. If radiation levels above 200 mP/hr at the surface or le mR/hr at one meter from the surface are
- measured, the package must not be shipped.
4. Properly complete two shipping lables indicating the radioisotope, activity and the Transport Index. The Transport Index is used only on Yellow II and Yellow III labels and is defined as the maximum radiation level in milliroentgens per hour measured at a distance of one meter i from the surface of the package. Put these two labels on l opposite sides of the package after making sure any previous labels have been removed. The package should be marked with the proper shipping name (Radioactive
- Material, Special l
- Form, n.o.s.) and the identification number (UN 2974).
If the source changer is packaged inside an outer container, j mark the outside package "INSIDE PACKAGE COMPLIES WITH 2 i l l l
- O i
l i i l l i i l 7-14a Revision 2 8 August 1985 i
- O 1
4 m ,,~,,-....--_a-a,nn,.,.,--.,,,n,,,- _,n..-e.,-- ,---.---,n..w_--n-w.
. _ _ _ ~ _. _ _ _. _. L 0 4
- O a
i i i l -Maximum Radiation Level i at Surface at One Meter I Radioactive White I Y ) 0.5 mR/hr None AMMIACTIVE I/ l \\ l ,7/ i Radioactive Yellow II i / 50 mR/hr 1.0 mR/hr R/D0 ACTIVE N /_ i
- O i
i Radioactive Yellow III J t 200 mR/hr 10 mR/hr l \\RA010ACilVENif \\ Y \\ l l. e i 6 j I !O ~.
v PRESCRIBED SPECIFICATIONS-TYPE B(U) USA /9096/B (U). " 5. Complete the appropriate shipping papers - Examples are shown in Figure 2 and 3. These shipping papers must include: a. Proper Shipping Name (Radioactive Material, Special Form, n.o.s.) and Identification Number (UN2974). b. Name of Radionuclide (Iridium-192) c. Activity of the Source (in Curies) d. Category of Label Applied (i.e. Radioactive Yellow II) e. Transport Index I f. Pacnage Identification Number (i.e. USA /9006/B(U) Type B) g. Shipper's Certification "This is to certify that the above named materials are properly classified, described, packaged, marked and labeled and are in proper condition for transport according to the applicable regulations of the Os Department of Transportation." Notes: 1. For air shipments, the following shipper's certification may be used: "I hereby certify that the contents of this consignment are fully and accurately described above by proper shipping name and are classified,
- packed, marked and labeled and are in proper condition for carriage by air according to applicable national governmental regulations."
1 2. For air shipments to, f rom or through the United States, a " CARGO AIRCRAFT ONLY" label and the shipping papers must state: "THIS SHIPMENT IS WITHIN THE LIMITATIONS PRESCRIBED FOR CARGO ONLY AIRCRAFT." f 6. Due to the depleted uranium used as shielding in the source changer, a notice must also be enclosed in or on the package included with the packing list, or otherwise forwarded with the package. This notice must include the name of the consignor or consignee and the following statement: "This package conforms to the conditions and limitations specified in 49 CPR 173.424 for excepted radioactive material, articles manuf actured f rom depleted uranium, UN 2909." s
u.p,n,.md by the to i a >,. n.< 6.u a e., .rn, s.u.,. .. 4,, is .s.it re.e to....-n.<,-. i.sfk.u.o.niCa.ro,,i.
- 6 w..
=. . Cas..e c3 C io. i une inee d.H.in.e r . of C1n.ohd.i.d 7 STRAIGHT BILL CF LADING. SHORT FORM Shipper's ORIGINAI. - NOT NEGOTI ABLE Carrier's No. CARRIER: RECfWED...b,.c. to u. cl 4c.i d i.nft...H.,
- u. d.. a ine
.i in B ii.i14 dan, R ADI ATION PROD. DIV. OF / t 19 From Tech / Ops, Inc. , rtington. Mass.
- m,, ms a 6
.w.,4 m,i,.., a, ., c.. 4 o a,.m.m. a. p,,.4 6,,, m. ,s 4 a,ry. 4 4 .w .w ,6,,i ..,= 4.,.m..u,., a
- o. af su u t*
.de" " i p c..f d,p.o,,.i ,.d t.i a.t"'.y i.ne co.tr .. v h.ec, i.a u. p..oo. n...w..,.o,.a.
- g th o..
oron. ,. e,. .i.<n,.,,,.i.., c.o.me.r e.s. .d .soo.d thg%u.t tm ca..c.i .e i.n a..J***",-. in ii> ornn.i ,.n.a m 4 a,u.n, 4. .a u .,. u 4a.o a.u t. e,- ca <>,.s u, ws. sou ia .u u.,...m.
- a. J. '7.".',.<6.c,.n..,n.a
- ,,,u
~ nao. ~ u una< ne ,ier.n.ca .i 6m.-r w 6.s.m.i i.m.i.,mem c ie,.i n. i. ..a. .a .g. ..a. .sn,m.mn. ni ...im.i.m,.i.. .m. - ...in i.i i.n...... 4 .r im. i.i r i.4.,..,i... au.. .w -.- x. 2.c. i. u. .-.w < im. e M I or.ir i.de of c P., p rpo.i u6,.i ly. Tech / Ops, Inc. Consigned to Radiation Products Divisien oestination 40 North Avenue Burlington, Massachusetts 01803 USA Car InitieJLendEumber Rout 1 Kina of Pack age. t>escription of Articles, SDecial Marks and E.coptions f *
- [8"' d
- Cob 0 Co
- .,,.. t s.o,ni.T f C.,.diuo af g
i k ber ~ 6,u a4.,,, i u...n# 1 Meta 1 Container ( AI Mode 1500 SU ) !.7,',.*.i '.'.". ',":' *,"/*. '"" i... u,, , o.u..., u,, t l '-a. ~.=*at Radioactive Material. Special Form N.O.S. UN2974 Ir id ium-!92 27 Curies v -.n.n -. ..e i t,*i. 4.n nw . m <. a in ,m ., i..f.o en., Radioactive Yellow II Labels Transport index: 0.4 TECHitP5 +w. of <ec.w o. n os.,,.. w,,,,.,.., ,.. % To n P-USA / 9006 /B(U) Type B ,. ~ I. 4 k v.n.d s ra t ,,., i. pr . i, en.,, ihe p,up y 6.evth.d n, u. l A,e ., L un F.
- crn, i.u.
.i n,.,,.a I t C n.rs j l .a. a s I 6 RELE ASED VALUE NOT TO EXCEED 40c PER POUND This is to certify that the above named materials are properly classified, described, packaged, marked and labeled and are in proper condition for transportation according to the apphcable regulations of the Department of Transportation. tre.,.m m <. . n e, n. w.,m ,m .., ui. i.a i u t,, u a. 4.,ns n.a .n,u <.m .a.,p ..'E*,m.m.yre. i-p,n>Tw. -.. <, ri ,,,,,m e,.-5o,....,.u.,,.,.,...~e. c ra.a,...m. u........ a u,m,, n:. m . in. Tech / Ops. Inc. shipper. Per Agent Per Po,menent post-office address of shippe, 40 North Avenue Burlington, Mmachusetts 01803 U S A.
SHIPPER'S DECLARATION FOR DANGEROUS GOODS Shipper Air Wagil No. Page 1 of I Pages Shipper's Reference Number (cononno Consignee Tech / Ops, Inc. Radiation Products Division 40 North Avenue Burlington, Massachusetts 01803 USA Two completed and signerd copses of stus Declaration must be ha:xted to the operator. wApNlNa TRANSPORT DETAILS Failure to comply in all respects with the applicable Dangerous Goods Regutations may be in bread 1 of the sh t e Airport of Departure: apphcable law, subject to legal pena;tes. This Dedarabon must not, in any orcumstances, be completed and/or signed by a consolidator, a forwarder or an IATA cargo N CARGO agent. LY Shipment type roe ere waooecab or Airport of Destination: BOSTON g --; g,g g NATURE AND OUANTITY OF DANGEROUS GOODS Dangerous Goods identtcaten l l
- g,:
ChaMify and Paceung A h abon ' ctass ; UN W' Prxer shoping nan fo n'e, o i &e ,,,on 6. 7 'UN2974i l Iridium 192 Metal Solid . II i Special Radioactise Material Special Form N.O.S. l Yellow iForm 27 curies j j Certificate l
- USA /0154/S l
} T.I. ! Type B(U) i Packsge l l 0.4 ! Certificate l l j j { USA / 9006B(U) l l l l1 Type B(U) Package l l
- 5 in x
l j l 6 in d l l l !!I in ! I I _L_______ Additional Handkng information n I hereby declare that the contents of this consignment are fully and accurately Name/ Title of Signatory desenbed above by proper shipping name and are dassified, packed, marked Radiological Technician and labelled. and are in all respects in the proper condition for transport by air Place and Date according to the apphcable Intemational and National Govemment Regula-Burlington, M A ti ns Signature (see wwwng above)
7. For shipment of an empty source changer, assure that there is no source in the container. If the radiation level is below 9.5 mR/hr at the surface, and there is no measurable radiation level at one meter from the container, no label is required. Mark the outside of the package with the proper shipping name (Radioactive material, articles manufactured f rom depleted uranium UN 2999). Mark the outside of the package: " Exempt from specification packaging, shipping paper and certification, marking and labeling and exempt from the requirements of Part 175 per 49 CFR 173.421-1 and 49 CPR 173.424." Additionally, a notice must be enclosed in or on the package included with the packing list or otherwise forwarded with the package. This notice must include the name of the consignor or consignee and the statement: "?ais package conf orms to the conditions and limitations specified in 49 CFR 173.424 for excepted radioactive materials, articles manufactured from depleted uranium, UN 2909." rs 8. Return the container to Tech / Ops, Inc. according to proper I] procedures for transporting radioactive material as established in Title 49 Code of Federal Regulations part 172-178. Note: The U. S. Department of Transportation, in 49 CPR 173.22 (c) requires each shipper of Type B quantities of radioactive material to provide prior notification tc t.Le consignee of the dates of shipment and expected arrival. i 7
h ehNhme Table 1 Source Assemblies Used In Conjunction With Automation Industries Model 500 SU Source Changer Automation Industries Source Assembly Designs 41701, Al 200-520-008, N1 39990, A10 [ Cap N] 200-520-009, N2 130013, All 200-520-010, N3 [ Cap N] 200-520-008, N4 41706, B1 200-520-011, N5 41706, B2 (Cap B & N] 41706, B3 36910, T1 [ Cap T] () 36910, T2 [ Cap T] \\_) 41708, C1 200-660-009, T3 [ Cap N] 41708, C2 [ Cap C & N] 36910, TS [ Cap T] 41708, C3 200-660-009, T6 (Cap N] 41039, H1 [ Cap B & N] 39998, G1 [ Cap NJ 41045, J1 [ Cap J & N] 39998, G2 [ Cap N] 39998, G3 [ Cap G) 39998, G5 [ Cap N] 39998, G6 [ Cap G] Tech / Ops Source Assembly Designs A424-1 [ Cap T] A424-9 [ Cap N] 814 [ Cap N) 848 [ Cap G] 866 [ Cap P] [ Cap X]: Holddown cap identification for use with Model 500 SU Source Changer
6,0 Acceptancg Zgggp DDB EpiDLEDDDGE 21Dgram 8.1 hCGR2%AD22 ZgDLB B.1.1 Visual IDB222119D The package is visually examined to assure that the appro-priate fasteners are properly seal wired. The package is inspected to assure that the proper marking and labeling is present. The seal weld of the radioactive source capsule is visually inspected for proper closure. 8.1.2 SiruGiuxAl BDs3 21R&DDLR TeStB The swage coupling between the source capsule and cable is subjected to a static tensile test with a load of one hundred pounds. 8.1.3 Lrah Isais The radioactive source capsule, which serves as the primary containment, is wipe tested for leakage of radioactive contamination. The source capsule is subjected to a vacuum bubble leak test. These tests are described in Section 7.4.1. Failure of either of these tests will prevent use of this source assembly. 8.1.4 CompoDRnt Tests The lock assembly (source holddown assembly) of the package is tested to assure that the security of the source will be maintained. A simulated (dummy) source assembly is installed in the source changer and the appropriate source holddown cap is installed. Verification is made that the source holddown cap contacts the source assembly prior to the threads being fully bottomed. A check is made that the holddown cap is securely attached to the device. Additionally, the locking arrangement and lock slides are tested to assure that the lock slide secures the source assembly and the lock secures the lock slide. Failure of any of these tests will prevent use of the package until the cause of the failure is corrected and retested. 8.1.5 Tests 10I Shjelding IDiggIlly With the package containing a source assembly, the radia-tion levels at the surface of the package and at one meter l from the surface of the package are measured using a small detector survey instrument. These radiation levels, when 8-1 Revision 2 8 August 1985 /G V l -w 7 y-a,,,-.,..-
extrapolated to the rated capacity of the package, must not exceed 200 milliroentgens per hour at the surf ace of the O. package. 8.1.6 1bszwal bGss9taDGs Inska Not applicable. 8.2 ERiDLRDADG2 E199135 8.2.1 EtxDGkDERl ADC RISBSDER ZRBtB Not applicable. 8.2.2 LRRh 19212 As described in Section 8.1. 3, the radioactive source assembly is leak tested at manuf acture. Additionally, the source assembly is wipe tested for leakage of radioactive contamination every six months. 8.2.3 EDb2ystsm EniDLRDRDGE The source holddown is tested as described in Section 8.1. 4, prior to each use of the package. Additionally, the package is inspected for tightness of fasteners, proper seal wires, and general condition prior to each use. 8.2.4 .ValM221 ED2% DER DiBG2s DDD Sinsketh Not applicable. 8.2.5 ShieldiDs Prior to each use, a radiation survey of the package is made to assure that the radiation levels do not exceed 200 milliroentgens per hour at the surface nor ten milliroent-gens per hour at three feet from the surface. 8.2.6 TbsImal Not applicable. 8.2.7 EiBGBllDDR9DR Inspections and tests designed for secondary users of this package under the general license provisions of 10CFR71.12 (b) are included in Section 7.4 8-2 Revision 1 19 April 1985 4 --}}