. TENNESSEE VALI EY AUTHORITY Watts Bar Nuclear Plant P. O. Box 800 Spring City, Tennessee 37381 September 9, 1986 Director of Nuclear Reactor Regulation Attention: Mr. B. J. Youngblood, Project Director PWR Project Directorate #4 Division of PWR Licensing - A U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Room 440, 5 Story Phillips Bethesda, Maryland 20814

Dear Mr. Youngblood:

In the Matter of the Application of ) Docket Nos. 50-327 Tennessee Valley Authority ) 50-328

SUBJECT:

EMPLOYEE CONCERNS TASK GROUP (ECTG)

Enclosure 1 to this letter transmits for NRC review 5 element reports addressing Sequoyah Nuclear Plant employee concerns in the operations category. (These reports have been reviewed and approved by the Senior Review Panel.) To assist you in your review of these reports, Enclosure 2 provides a comparison between the ECTG Writer's Guide recommended ehment report format and the operations reports. Enclosure 3 provides a listing of the element report number and the related employee concerns.

Please feel free to contact Martha Martin at F*S 857-3587 (Watts Bar) If you have any questions.

Very truly yours, TENNESSEE VALLEY AUTHORITY hh &

J. A. Mcdonald Site Licensing Manager Enclosures cc (Enclosures):

U.S. Nuclear Regulatory Commission Region II Attn: Dr. J. Nelson Grace, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 6 Mr. James M. Taylor, Director Office of Inspection and Enforcement h U.S. Nuclear Regulatory Commission -

Washington, D. C. 20555 8609120364 PDR ADOCK860909 0500032,/

p PDR An Equal Opportunity Employer

-=,

,e

. \

OPERATIONS CATEGORY .

Enclosure 2 <.'

Page 1 of 2 -

, ECTG WRITER'S GUIDE OPERATIONS (OP) ELEMENT REPORTS NOTES /CONMENTS 1.0 Issue I. Title The brief introduction Characterization Very brief introduction touches on the source of the concerns.

2.0 Summary I. Title 1. The Conclusions are Very brief introduction towards the end of the findings.

III. Finding (Conclusions) 2. The Conclusions services as a summary of the findings.

4 3.0 Evaluators Cover Sheet 1. The printed name of the original evaluator (s) appears on the cover sheet.

4 2. The peer reviewer and CEG-H approval signa-tures are also on the cover sheet.

1 4.0 Evaluation II. Specific Evaluation Process Nethodology 5.0 Findings III. Findings 1880T

~

it .

Enclcsura 2 -

Page 2 of 2 .

s ECTG WRITER'S GUIDE OPERATIONS (OP) ELMENT REPORTS NOTES /CONMENTS 6.0 Root Cause IV. Root Cause 1. At the element level (Collective Significance) the Root Cause is often not identifible.

2. Collective significance is not addressed at the element report level.

7.0 Attachments / II. Specific Evaluation 1. A list of the concerns List of Concerns Methodology with text are included within this section.

2. Other reports are sometimes attached.

9 9

e

.; Enclosura 3 Page 1 of 1 SEQUOYAH EMPLOYEE OPERATIONS CATEGORY CONCERN ELEMENT REPORTS NUMBER ISSUE OP30112 IN-86-064-001 Mechanical Equipment Reliability / Design OP30206 SQP-5-004-002 Transfer Canal SQP-6-Oll-001 Electrical Equipment Problem OP31102 00-85-005-011 Radioactive XX-85-101-003 Material Control JAM-86-001 MRS-85-003 OP31201 XX-85-048-001 Adequacy of PSO Uniform in Nuclear Plant Environment OP31306 IN-86-221-002 Questionable Concrete IN-86-221-003 Repair (Grout) 1880T