ML20209D534
| ML20209D534 | |
| Person / Time | |
|---|---|
| Issue date: | 04/28/1999 |
| From: | Meyer R NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES) |
| To: | David Williams OAK RIDGE NATIONAL LABORATORY |
| References | |
| NUDOCS 9907130158 | |
| Download: ML20209D534 (16) | |
Text
gpreog
)h(
t UNITED STATES
,4 g
j NUCLEAR REGULATORY COMMISSION t
WASHINGTON, D.C. 302A64001 p
Y*****/
i April 28, 1999 Mr. Don Williams Oak Ridge National Laboratory P.O. Box 2009 Oak Ridge, TN 37831-8065 i UELIC COCUMENT H00M
Dear Mr. Williams:
Per your request, I am enclosingM M Mite 7akeh on mixed-oxide fuel use in commercial light water reactors. This paper was thei attachment to a memorandum from the Executive Director for Operations to the five NRC Commissioners dated April 14,1999. That memorandum contained some predecisionalinformation and is being withheld from public disclosure. The attachment, on which the memorandum was based,is being placed in the NRC Public Document Room along with tNs letter and will be available to the public.
Sincerely, Ralph O. Meyer, Senior Technical Advisor Safety Margins and System Analysis Branch Division of Systems Analysis and Regulatory Effectiveness Office of Nuclear Regulatory Research
Enclosure:
As stated l
1 l
cc: NRC PDR l /
9907130158 990428 PDR ORG NREB#
SfS-}
S
4 i
ATTACHMENT MIXED-OXIDE FUEL USE IN COMMERCIAL LIGHT WATER REACTORS i
INTRODUCTION in January 1997, the U.S. Department of Energy released a record of decision for the storage and disposition of weapons-usable fissile materials. In this record, DOE recommended that excess weapons-grade plutonium be dispossd of by two methods: first, reconstituting the plutonium into mixed-oxide (MOX) fuel rods and buming it in current light water reactors, and second, immobilizing the plutonium in glass logs with appropriate radioactive isotopes to deter theft prior to geologic disposal. Based on current information,it now appears that, if the MOX fuel method is utilized, fuel thbrication will take place at the Savannah River site in South Carolina with buming in nearby Westinghouse-type PWRs. Although DOE may not begin developing a license application right away, Congressional approval has already been given for NRC facility regulation and a number of issues will eventually need to be considered.
This paper provides an overview of the technicalissues associated with the use of MOX fuelin light water reactors. The majority of relevant U.S. experience is from experiments that were pedormed during the time when reprocessing was considered an option for the future. These experimcats are described below. Additionally, the experience from other countries, which continue to pursue the use of MOX fuel, is highlighted, including the lessons leamed and experimental results gained from their programs. The basics of plutonium are discussed and the differences between uranium-based fuel and MOX fuel are described. The specific issues that will need to be considered prior to the fabrication and use of weapons-grade plutonium in U.S. reactors are also discussed.
BACKGROUND in the beginning of the U.S. nuclear reactor program, it was anticipated that the fuel cycle wculd be closed by reprocessing spent fuel to recover the usable plutonium and uranium for use as MOX fuel in thermal or fast reactors. Spent fuel reprocessing would perform the dual function of recycling the fissile isotopes that have enough energy to be reused and reducing the iong-lived actinides by incorporating them into the MOX fuel and buming them in a reactor. This would significantly reduce the decay time for the remaining wastes. Programs to determine th' economic and practical feasibility of using MOX fuel were developed ta obtain a practical MOX fabrication process and reactor implementation method. In the early 1970's, the major obstacles to plutonium mcycle were thought to be solved; therefore, testing programs began to be phased out while a reprocessing plant at Bamwell started the licensing process and was partially constructed. To study the environmentalimpact of using MOX fuel, NRC continued developing the Final Generic Environmental Statement on the Use of Recycle Plutonium in Mixed Ox!de Fuel in Light Water Cooled Reactors (GESMO, NUREG-0002,1976) that had been started by its predecessor, the U.S. Atomic Energy Commission.
On April 7,1977, the U.S. announced a decision to defer indefinitely the commercial reprocessing and recycling of the plutonium. France, Belgium, the United Kingdom, Germany, and Japan all continued to pursue the recycle option, and routine buming of MOX fuelis now carried out in most of those countries.
a 2
The use of plutonium to fuel commercial reactors in the U.S. is again being considered following the 1994 U.S. agreement with Russia to reduce the inventory of fissile material from nuclear weapons. To evaluate the desirability of utilizing weapons-grade plutonium in U.S.
LWRs will require revisiting previous information and investigating new MOX technologies that have been developed and used in other countries.
Basics of Plutonium
' Plutonium is the 94th element of the periodic table and is composed of more than a dozen different isotopes. It exists in extremely limited quantities in nature; therefore, most of the world's current inventory of plutonium has been created by man. The isotope with the mass number 239 is the easiest to produce and the most useful for nuclear chain reactions. Pu-239 is produced by neutron capture in U-238, the most abundant uranium isotope. Because current reactor fuel contains large quantities of U-238, this conversion process occurs over the lifetime of the fuelin thermal reactors, providing a self generating fuel source. Plutonium 239 is a radioactive isotope which decays primarily by alpha emission. It has a half life of 24,100 years.
Rve other plutonium isotopes have half lives greater than 10 years, with the longest being
- 80,000,000 years for the naturally occurring Pu-244.
Differences between weaoons-orade clutonium and reactor orade clutonium The primary difference between reactor-grade plutonium and weapons-grade plutonium is the isotopic composition. Reactor grade plutonium is created by irradiating normal LWR uranium-based fuel and then reprocessing the spent fuel at the end of its life to extract the plutonium isotopes. Weapons-grade plutonium is created by irradiating U-238 to an optimally low bumup and then separating the isotopes to produce a different isotopic mixture. DOE defines the different plutonium grades by the amount of plutonium-240 that the mixture contains because the most desirable plutonium mixture would be composed of only the odd-numbered fissile
. isotopes. Weapons-grade plutonium, which is the most purified of the grades, contains less then 7% Pu 240, followed by fuel-grade plutont,'n with 719% Pu-240, and the least purified reactor-grade plutonium with greater than 19% Pu 240. Table A gives typical concentrations of the most abundant plutonium isotopes. For the purposes of this paper, all grades containing more than 7% Pu 240 will be called reactor-grade plutonium.
Table A. Typicalisotopic composition of weapons-grade and reactor-grade plutonium (wt%)
lsotope Weapons grade Reactor grade Pu 238 0.05 1.0 Pu-239 94.3 59.0 Pu-240 5.0 24.0 Pu 241 0.6 11.0 Pu-242 0.05 5.0
3 There are several practical differences between reactor-grade and weapons-grade MOX fuel.
Weapons-grade plutonium, with its higher Pu 239 content, creates a harder neutron spectrum.
l it is also expected that the weapons-grade MOX fuel will contain v m 7 wt% plutonium, l
whereas the European reactor-grade MOX fuel has approximate 7. wt% plutonium. These I
differences will have to be taken into account.
In addition to the different isotopic compositions, weapons-grade MOX fuel will have traces of gallium that might react with zirconium alloy cladding. Gallium was added to the weapons-grade plutonium to act as a stabilizer for the plutonium metal used in the production of nuclear I
weapons. This element can be removed chemically, but this is an expensive process; thus, l
weapons-grade MOX fuel may contain some gallium.
Differences between MOX and Uranium-based fuel l
Table B shows approximate isotopic compositions at the beginning of life and the end of life for a typical uranium-based fuel and a comparable low enrichment weapons-grade MOX fuel. The valuss shown are for illustration only as actual amounts will vary depending on the particular l
core design and power history, but the general trend is clear. Both fuels contain a lot of U-238, but the uranium-based fuel has no plutonium isotopes at the beginning of life (BOL) and less of the plutonium isotopes at the end of life (EOL).
l Table B. Approximate isotopic composition of a uranium-based fueli J a MOX fuel (wt%)
I
(
lsotope BOL U-Fuel EOL U Fuel' BOL MOX Fuel EOL MOX-Fuel' U 235 3.25 0.72 0.19 0.06 U 238 96.75 94.0 96.3 94.1 0.56 3.31 1.0 Pu-239 0.23 0.176 0.40 Pu 240 0.11 0.021 0.30 Pu-241 0.07 0.003 0.14 Other Pu isotopes 4.0 4.31 Other Nuclides
- Bumup of 37.6 mwd /kg used for this example The isotopic compositions of the two fuel types produce different cross section parameters, which impact the characteristics of the reactor core. Plutonium has a higher thermal absorption cross section than uranium, and this reduces the reactivity worth of the control blades, bumable poisons, and liquid absorbers used to control the reactor. The reduction is caused by competition for neutrons us! ween the fuel and the absorber materials. The greater absorption in plutonium results in less neutron absorption by the absorber materials in a core wkh MOX fuel. The fission cross sections of the two fuels also differ MOX fuel has a higher fission cross section, which means that, of the neutrons absorbed in the fuel, a greater percentage result in fissions. The higher fission cross sections of the MOX fuel create more flux depression across a fuel assembly from seli shielding, and they cause power peaks when MOX fuel rods are close 1
l 4
to UO, fuel rods. These changes in cross sections have to be accommodated in core design.
Added to the cross section effects are other nuclear characteristics that change core behavior.
Or.e is the lower delayed neutron fraction (beta) of MOX fuel. The beta value gives the percentage of neutrons released after fission from the decay of fission products. These neutrons make it possible to control the reaction during nomial operation and transient
- conditions, and the lower beta value makes reactor control more difficult. Another significant neutronic effect is the harder neutron spectrum praduced by MOX fuel. That is, there are more high energy neutrons in a core with MOX fuel than with uranium-bcsed fuel. This harder spectrum results in more U 238 reactions since U 238 is a high energy absorber. The harder spectrum can also increase the vessel fluence depending on the fuel management techniques used in the core seload. However, the reactivity of MOX fuel decreases at a slower rate with bumup in comparison to uranium-based fusi such that less excess reactivity is needed for MOX fuel at the beginning of core life. Finally, the energy released per fission is slightly higher for MOX fuel, and the decay heat, which is smaller at first, becomes larger after one year compared with irradiated UO, fuel. All of these factors have to be taken into account in core design and safety analyses.
The two fuel types differ in material properties as well. The thermal conductivity of MOX fuel is aoproximately 10% lower than standard UO, fuel. Thus, for a given fuel rod power, MOX fuel '
pellets will operate at somewhat higher temperatures during normal operation. This will have an effect on the initial conditions for lost-of-coolant accidents. It will also increase fission gas release during nomial operation, and this will affect the radionuclide inventory in the pellet-to-cladding gap, the fuel rod intemal pressure, and the thermal conductivity of the gap (i.e., the gap conductance). _ Fresh MOX fuel has a fuel melting temperature that is about 10 "C lower than uranium-based fuel. Fuel melting is not approached during normal operation or design-basis accidents, but this might have some effect on severe accidents. The thermal expansion coefficient of MOX fuel is approximately 1% higher than that for uranNm-based fuel and this would increase the pellet-to-cladding mechanicalinteracto (PCMI). However, MOX fuel pellets have a higher creep rate than UO,, which would tere N decrease PCMI because the porous pellet can be compressed.
Finally, MOX pellets are usually fabricated by mechanically blending UO, and PuO, powders, then pressing and sintering them. This results in a ceramic that is not homogeneous on a microscopic scale, and the little is: ands of high plutonium concentration act as hot spots because of their high fissile content. This may affect the behavior of the pellets during reactivity transients. Technicalissues relateo to these differences between MOX fuel and uranium based fuel are discussed later in this paper.
PREVIOUS U.S. STUDIES AND RESEARCH ON MOX FUEL Previous efforts focused primarily on recycled thermal reactor spent fuel to investigate the feasibility of using MOX fuelin thermal and fast reactors. it was originally envisioned that the fuel cycle wwld be closed by reprocessing the spent fuel, thus reducing the amount of high-level waste, buming the long-livad actinides, and recovering the usable energy left after discharge from the reactors. Thus, fuel performance and characteristics of reactor-grade MOX fuel have been rather extensively explored and ch/nented in previous U.S. efforts. Most of the tests were eventually phased out because d was be7eved that the feasibility of using MOX
1 5
fuelin reactors had been demonstrated, and other tests were ended following the decision that MOX fuel would not be used in the U.S. The following is a brief overview of some of the programs sponsored by the AEC, the NRC, and EPRI to investigate the feasibility of using MOX fuel.
Saxton
.The Saxton Plutonium project was conducted by Westinghouse Electric Company for the AEC in the mid 1960's. It was the first plutonium fuel project; therefore, the basic characteristics of MOX fuel were hypothesized from the plutonium elemental characteristics but nad not been verified by actual reactor irradiation when the program was initiated. The purpose cf the program was to develop basic information about the use'of plutonium fuelin a standard PWR
. including the fuel performance characteristics and irradiation-induced behavior.
The program consisted of two phases. The first phase was to develop methods of fuel fabrication and design, perform critical experiments and power operations, and then conduct
. post-irradiation examinations of the fuel. The second phase of the program was to irradiate the fuel to higher bumup levels to evaluate the feasibility of utilizing reprocessing and MOX fuel to close the fuel cycle.
The Saxton PWR reactor core consisted of 21 fuel assemblies of which the center nine were composed of MOX fuel, which had an isotopic composition similar to weapons-grade plutonium.
The remaining surrounding fuel assemblies were of standard uranium-based fuel. For the program's first phase, the MOX fuel assemblies were constructed of fuel rods that contained a similarisotopic composition and bumup, while in the program's second phase the fuel assemblies were constructed of fuel rods with various bumups.
These post-irradiation tests provided the first glimpse of the characteristics of irradiated MOX fuel. It was found that the diameter of the fuel rods decreased after irradiation, although the change in length was negligible. Examination of the fuel pellets showed that fuel restructuring phenomena was limited, pellet-to cladding mechanical interaction (PCMI) was absent in all MOX fuel pins, and densification of MOX fuel occurred under irradiation. The observations indicated that the overall performance of the MOX fuel tested under the operating conditions of the Saxton PWR was similar to that of UO, fuel and was satisfactory.
~ Plutonium Reevele Test Reactor (PRTR)
' The PRTR was utilized as the irradiation facility for the Plutonium Utilization Program conducted by Pacific Northwest Laboratory for the AEC. The purpose of the study was to develop technologies for the use of plutonium in commercial reactors. The test facinty was used to irradiate various mixed-oxide fuel types t'nder steady-state conditions to determine which fuel
. types provide the best performance and the greatest economic advantage. The tests were performed at high linear heat generation rates and progressed to bumups greater than 18 mwd /kg to capture effects over a wide range of operating conditions. Following irradiation, post-irradiation tests were conducted to assess the fuel's performance.
The fuel types differed by the methods of preparation, which included vibrationally compacted particles, compacted and swaged particles, hot-pressed pellets, and cold-pressed and-sintered pellets. During f abrication, some cladding defects were intentionally incorporated into some
6 fuel elements. These intentiorially defective fuel elements, along with other unintentional defects, provided an opportunity to observe the consequences of MOX fuel defects under operating conditions. Fuel assessment was completed with post-irradiation measurements.
Those measurements included visual inspections, dimensional changes, gamma scans, fission gas release, fuel and cladding microscopy, and bumup analysis. The PRTR program concluded that these mixed-oxide fuel types performed well throughnut the range of steady-state operating conditions, even when defects were present.
GESMO The Generic Environmental Statement on the Use of Recycle Plutonium in Mixed Oxide Fuelin Light Water Cooled Reactors (GESMO) project was started in 1974 by the AEC to explore the scope, health, safety, and environmentalimpacts of widespread use of MOX fuelin U.S.
reactors. The final GESMO report was published in 1976 as NUREG-0002. The safeguards portion of the GESMO report was superseded in 1978 by NUREG-0414, which focused exclusively on the safeguarding of reactor recycle plutonium MOX fuel against a domestic threat. The GESMO program was indefinitely postponed before public comments and an ongoing hearing were completed. It was halted following the decision that the U.S. would not pursue recycling of any spent fuel generated within the U.S.
The GESMO program concluded that the most favorable option for the treatment of spent fuel, after a cost benefit analysis of six different options including no recycle, was the full recycle option. When the health effects attributed to the recycle of MOX fuel were assessed, this program concluded that the recycle option would not significantly increase the health effects compared with the no-recycle option. This assessment included the analysis of particle sizes of MOX fuel following e transportation accident and the determination that the particles would be too large to be inha.ed. Thus It was concluded that transportation accidents would not increase the threat of plutonium toxicity from Inhalation. It was further observed that the nonradiological impacts were lower for the recycle option than the no-recycle option. On the basis on these findings, the GESMO report recommended that the recycle of plutonium and uranium from spent fuel and subsequent use of MOX fuel should be pursued.
EPRI Tests The Electric Power Research Institute (EPRI) conducted a number of MOX fuel experiments in operating commercial reactors after the feasibility of using MOX fuel had been established. In-core irradiations were performed to increase the experience with MOX fuel and determine the methodologies needed to assess MOX fuel. For these tests, MOX fuel assemblies were loaded into selected cores at Quad Cities, San Onofre, and Big Rock Point. After irradiation, the fuel assemblies and individual fuel rods were examined and the isotopic compositions of the fuel were measured. A'ter assessing the in-core performance of these test assemblies, it was concluded that MOX fuel performance was similar to uranium-based fuel performance in commercial LWRs, though some differences between the two types were observed. The significant differences noted between the two fuel types included reactivity effects, which decrease reactor control, and a higher decay heat at long cooling time", with MOX fuel.
EPRI also sponsored a study at Pacific Northwest Laboratory to investigate the det.sification behavior of mechanically blended MOX fuel. The study also looked at thermal resintering, irradiation effects on the MOX fuel structure, and inte -diffusion of uranium and plutonium
'7 (homogeneity). The project consisted of pellet fabrication, pre-irradiation pellet characterization, resintering tests, irradiation in the General Electric Test Reactor (GETR), and detailed post-1 frradiation examination. The study concluded that MOX fuel shows simdar densification behavior to that obseNad in uranium-based fuels, and that the presence of plutonium up to about 6 wt% and particle size up to 500 microns did not affect the physical behavior of the fuel.
EXPERIENCE WITH MOX FUEL Some countries continue to pursue a c!osed fuel cycle utilizing reprocessed spent fuel. The experience they have gained from the use of MOX fuelin their commercial reactors and from tests performed with MOX fuel provides additional information on the characteristics and
. behavior of reactor-grade MCX fuel.
Current use and fabrication of MOX fuel Belgium was the first country to pursue the plutonium recycle option beginning in 1963 with the loading of 12 MOX fuel rods into the BR3 reactor, an 11 MWe PWR. To produce the fuel needed for this reactor, in which the MOX fraction was progressively increased to 48% and for other reactors projected to begin using MOX fuel, Belgonucleaire built the Dessel fabrication plant, known as DEMOX. This plant was the first commercial fabrication facility in the world and cor. inues to be the world leader in MOX fuel fabrication. In 1988, when France decided to pursue the MOX fuel option in their PWRs, they contracted the DEMOX plant to provide the fuel fabrication. To facilitate the reprocessing of spent fuelinto new MOX fuel pellets, the Belgians pioneered a new method of blending the MOX fuel powder cal;ed the MIMAS procesc This process improved the method of incorporating the plutonium into the uranium matrix which provides better fuel characteristics and chemical separation of the fuel during reprocessing.
This method is currently the industry standard for MOX fuel powder blending. Since 1995, MOX
)
fuel has been used in 2 Belgian PWRs.
j Considering the increasing delays in development of the fast breeder reactor in France, Electricits de France (EdF) decided to start recycling MOX fuel in PWRs in 1985. Of the 54 PWRs in France,16 are now loaded with MOX fuel and more will be loaded in the future. Spent j
fuelis reprocessed at La Hague, now the largest reprocessing plant in the worid, and the fissile material is fabricated into fuel rods in a Cogema facility at Cadarache and the Melox plant at Marcoule. To accommodate the reactivity effects and decreased shutdown margin incurred from using MOX fuel, the French have limited the reactor core loading of MOX fuel to 30%,
added an additional four control rod assemblies to each core, and increased the amourR of boron in the reactor water storage tank and boron makeup tank. To reduce localized power peaking and improve reactor control of a MOX-fueled core, the French try to avoid loading MOX
)
assemblies in control rod locations and use a scatter-load fuel management technique.
The United Kingdom began experimenting with the use of MOX fuelin the 1960's. British Nuclear Fuels Limited (BNFL) began production of MOX fuelin 1963. Initially, the United Kingdom explored the use of MOX fuelin their advanced gas reactors (AGRs), but later redirected their efforts to the use of MOX fuelin fast reactors. There is no MOX fuelin the British LWR at the present time. BNFL initially built a small production facility, which has been recently supplemented with the newly constructed Sellafield facility. The f abrication facility at 1
Sellafield is adjacent to a reprocessing facility which minimizes the transportation of i
1 1
,<g
8 reprocessed plutonium.
Germany is currently using MOX fuelin more than a dozen of its 20 LWRs. Initially, Germany reprocessed its spent fuel at a reprocessing facility in Hanau, which produced all the MOX fuel assemblies for the German recycle program. That facility was closed in 1991 and current MOX fuel is produced in the Cadarache plant in France. Switzerland also uses MOX fuel in three of its five nuclear. power plants.
Japan began looking i_nto the reprocessing of spent fuel in 1979 with a focus on using recycled fuel in their Advanced The, mal Reactor (ATR), which is a heavy-water-moderated, light-water-cooled boiling reactor. To date, more than 670 MOX fuel assemblies have been irradiated in the Fugen ATR.' Full scale utilization of MOX will be started soon in Japan's LWRs, and safety reviews are currently underway. Japan does not currently have its own reprocessing facility and must rely on reprocessing and fabrication in other countries; however, a reprocessing plant is currently under construction in Japan and will become operational in the year 2000.
j CURRENT RESEARCH ON MOX FUEL 1
Because a number of countries are using reprocessed spent fuel, related test programs are being conducted at severallaboratories. These programs have investigated physical and neutronic characteristics of MOX fuel along with its operational performance. A brief synopsis i
of these programs and their findings is given in this section.
Halden The Halden Project in Norway is an undertaking of national organizations in 19 countries sponsoring jointly financed research. Tests in the Halden reactor are designed to provide basic 4
I data on how fuel performs in commercial reactors, both under normal operating and transient conditions, with emphasis on extended fuel utilization. In a 1995 Halden Project report. Tumbull reviewed MOX fuel properties measured in various programs in Europe, including measurements in the Halden reactor itself. Significant conclusions were (a) for a given linear heat generation rate, centerline temperature in MOX fuel is slightly higher (-40 C) than in UO, j
fuel as a consequence of reduced thermal conductivity, (b) there is no evidence that fission gas 1
release from MOX fuel is any worse than from UO, fuel except as a result of temperature differences, and (c) MOX fuel has a greater resistance to failure from pellet cladding mechanicalinteraction (PCMI) than UO, fuel because the creep rate of MOX fuel pellets is greater. Because of a need of participating regulatory bodies for qualifying models and codes, the Halden Project initiated new tests on MOX fuelin 1998. MOX fuel rod segments with bumups as high as 78 mwd /kg are being tested to generate data on thermal properties, fission gas release, and PCMI.
GAh!!i The Cabri test reactor in France is operated by the Institute for Protection and Nuclear Safety (IPSN) and is used to test nuclear fuel rods under reactivity initiated accident (RIA) conditions.
The fact!ity currently uses a sodium coolant test loop instead of a water loop, which would be more representative of PWR designs. Studies of highly irradiated UO, and MOX fuels were begun in 1993. Seven tests have been completed with UO, fuel and three with MOX fuel. One
t 9
of the three MOX fuel tests experienced cladding failure (the MOX rod with the highest bumup).
While this rod failed at a somewhat higher energy than high-bumup UO, rods, fuel dispersal from the failed rod and sodium ejection from the vicinity of the rod were more pronounced than i
with the UO, rods. It is believed that the softer pellets and enhanced fission gas release from j
the high concentration Pu agglomerates caused the MOX fuel to behave differently from the UO, fuel under these ' conditions.' IPSN plans to replace the endium loop with a water loop to more accurately simulate PWR core conditions. Additional tests are planned with very high-bumup UO, fuel and MOX fuel in this facility.
i NSRR The Nuclear Safety Research Reactor (NSRR) of the Japan Atomic Energy Research Instituta (JAERI)is being used to investigate the behavior of fuel rods under RIA conditions. Studies to determine the behavior of fresh MOX fuel were initially performed to provide baseline information. These initial tests repeated the conditions of previous tests performed with uranium-based fuel. It was found that the cladding failure mechanism and threshold for fresh
]
MOX fuel were consistent with those for fresh UO, fuel and that an effect of plutonium particles (inhomogeneities) was not detected. More recently, JAERI has tested four Irradiated MOX fuel rods (20 mwd /kg). Up to the limits of energy deposition tested to date (140 cal /g fuel enthalpy),
no cladding failures have occurred in these relatively low-bumup specimens. However, the NSRR tests with irradiated MOX have shown higher fission gas release and larger fuel swelling compared with UO, fuel (in agreement with Cabri results), indicating the existence of MOX effects for RIAs.
Current Studies The OECD/NEA Nuclear Science Committee set up a working group to study the current status and nuclear effects of recycling plutonium. These studies were undertaken by gathering operational and research information into a collective work and performing benchmark studies l
to augment the information. The information gathered was published as a series titled the Physics of Plutonium Recycling.
i One benchmark study of particular interest is a study on the effect of increasing the (reactor grade) plutonium concentration in each fuel rod and the resulting effect on the void coefficient.
It was expected that, at some higher concentration of plutonium, the void coefficient might become positive. As the moderator density decreases, the fission neutrons are not slowed down'as much. Pe 239 becomes more efficient as a fission source when there are more 1
1
' neutrons in the low epithermal resonance region and at high energies,1n contrast to uranium which becomes less efficient. Hence, a '.ss of coolant would increase core reactivity or equivalently, the void coefficient of res..Aty would become positive when there is a high Pu-239 content.
The participants in the study utilized various computer codes to predict the resultant void
. coefficient, and the results were compared to the reference solution that was generated by a continuous energy Monte Carlo calculation. The results of the benchmark demonstrated that the void coefficient of MOX fuel becomes positive between 9.7 and 14.4 wt% loading in each fuel rod. This suggests that an upper limit on plutonium content might be needed for MOX fuel.
The study was dons for reactor-grade plutonium, but the general conclusion should be applicable to weapons grade plutonium at slightly lower concentrations taking into account that
l
-10 i
there is a higher fraction of Pu 239 in this material relative to reactor-grade plutonium.
j Nevertheless, the upper limit with either type of MOX fuel appears to be at a concentration above the level of current interest.
TECHNICAL ISSUES Although NRC's General Design Criteria (10 CFR 50, Appendix A) are general enough to apply to all types of reactor fuel, some specific licensing requirements were developed for uranium-based fuels. There are, th;refore, technicalissues that should be addressed to ensure that specific licensing requirements and related analytical methods are adequate for MOX fuel, and that L'#Rs loaded with MOX fuel meet all the requirements.
Reactor Physics The reduction in the effectiveness of the reactor control system is perhaps the most important techn! cal issue that must be addressed for the plutonium disposition program. Control rod worth is reduced by MOX fuel because the increased thermal neutron cross section of plutonium allows the fuel to compete more effectively with the control mate:ials and absorb a
- greater number of neutrons. Additionally, the lower delayed neutron fraction (beta value) of MOX fuel lets a smaller reactivity insertion make the reactor go prompt critical; thus, there is less time for rod inser11on to provide reactor control. European MOX experience has shown that, with a MOX core loading of 30% or less, the core will remalli controllable without any modifications to the control system. With increased core loadings of MOX fuel above 30%, two alterations were found to restore the effectiveness of the control system in P.WRs: increasing
. the B-10 content of the soluble boron and using coritrol rods with hafnium and boron carbide instead of the current silver indium-cadmlum type. Altemately, additional control rods could be added to the MOX fueled cores. Some reactors (Combustion Engineering) were initially designed to hold extra control rods for MOX cores, and other reactors have contnt: rod positions that are not currently used. Wnichevei method is used, a thorough assessment will be needed to ensure that the reactor will continue to meet the requirements of General Design Criteria 26-28 (10 CFR 50, Appendix A) when it is using MOX fuel.
The fission cross sections in MOX fuel are also larger than those in UO, fuel, and this can result in steep flux gradients between adjacent MOX and UO, fuel rods! This effect can be reduced with enrichment variations and core design. Another consequence of the differences in cross sections between plutonium and uranium are the changes in the moderator temperature coefficient, the Doppler (fuel temperature) coefficient, and the coefficient of reactivity for coolant voids. Core design and safety analysis will have to take into account these changes in reactivity ccafficients.
Plutonium fissioning in MOX fuel produces a harder (higher energy) neutron energy spectrum and this would increase the flux of high energy neutrons in the reactor vesselif.MOX assemblies were loaded near the core periphery. A higher flux of energetic neutrons would accelerate the embrittlement process caused by neutron damage to the material. This effect would be similar to putting fresh uranium fuel on the edge of the core, which is avoided in current practice. Thus, renewed attention will have to be paid to core loading pattems to avoid excessive vessel fluence.
l 11 The increased energy released per plutonium fission, compared with uranium fission, and the early decrease in decay heat for MOX fuel will affect the analysis of loss-of-coolant accidents (10 CFR 50, Appendix K). These reductions will tend to offset the increased stored energy that is mentioned below. These changes in energy release arid decay heat will also affect the thermal-hydraulics of cooldown events, and these events will be analyzed to fully understand the potentialimpact.
Most or all of these reactor physics issues require quantitative analysis with computer codes.
Therefore, NP^ analytical codes will have to be upgraded to include MOX-specific parameters, and industm Mes will have to be reviewed for use in licensing. Some of the most critical models the 40d to be added to the kinetics codes include multiple energy groups (four or j
more) with upscatter, a modeling capability to capture the aarder spectrum effects, improved delayed neutron precursor calculations, a revised decay heat model, and a method to handle i
local power peaking.
Fuel Behavior Uranium dioxide and PuO are very similar ceramics, and MOX fuel behaves very much like 2
UO, fuel during normal steady-state operation. Nevertheless, subtle differences caused by somewhat different physical properties have a significant effect. The reduced thermal conductivity in MOX fuel causes the fuel pellets to operate at somewhat higher temperatures than in UO, fuel of the same linear power rating. While the higher operating temperatures would not be a problem for normal operation, the fuel temperatures determine the amount of stored heat present at the beginning of a loss-of coolant accident (LOCA). LOCA analysis is so 3
strongly dependent on this stored heat that it must be calculated accurately, and steady state l
fuel rod computer codes are therefore carefully reviewed in a licensing safety assessment.
NRC and industry codes will have to be modified to model MOX fuel adequately, and data to i
support these modifications will have to be obtained from the Halden test reactor and other programs.
In addition to considering normal operation, which sets up the initial conditions for a transient, two types of large transients are addressed in a safety analysis. One is the loss-of-coolant j
accident and the other is a prompt-critical reactivity accident. Other transients of lesser severity j
i are also considered, but these two are the most challenging. Fuel behavior during a t.OCA is determined almost entirely by the cladding. Ballooning, rupture, oxidation, embrittlement, and fragmentation have been studied and quantified in licensing safety analyses (see 10 CFR 50.46 i
and Appendix K). All of the early work on LOCA behav!or was conducted with empty Zircaloy j
tubes, so the type of fuel pellet would not have made a difference. However, recent NRC sfudies of LOCA behavior in high-bumup fuel are being conducted with intact segments of fuel rods (i.e., with the fuel left inside) because the chemical bonding between the pellets and the j
cladding may affect the ballooning process. Chemical bonding may be different for MOX pellets j
and UO, pellets, and the effect could be investigated. However, at this time a major effect is not expected.
In a PWR, which is the type of reactor now anticipated for plutonium disposition, the prompt-critical reactivity accident is a rod-ejection accident that is often referred to generically as a reactivity initiated accident (RIA). Several of the differences between UO, and MOX fuel will directly affect this event. The higher creep rate of MOX fuel may reduce the severity of the pellet cladding mechanicalinteraction that causes cladding failure at higher bumups. On the l
I
12 other hand, the higher fission gas release associated with plutonium hot spots may increase the severity of the interaction, and the higher gas inventory may also cause greater entralnment and expulsion of fuel particles after cladding failure. The one RIA test to-failure with MOX fuelin the Cabri test program suggests that this difference is significant. If there are any bumup limitations for MOX fuel that are different from UO, fuel, they would probably be related to this event. More testing of this type may have to be done with MOX fuel specimens to determine adequate regulatory criteria for MOX fuel for the rod-ejection accident (see Regulatory Guide 1.77).
Gallium is used in concentrations up to 1 wt% as an alloying element in the manufacture of plutonium pits for nuclear weapons. While gallium is not a good neutron absorber and therefore would not interfere with the chain reaction, gallium metal chemically attacks zirconium. Since fuel rod cladding is made of zirconium alloys, effoits will b9 made to remove gallium from the l
weapons plutonium. While the fabrication process to be used fcr making PuO will reduce the 2
concentration of gallium to part per-million levels, its effacts on fuel and cladding behavior have not yet been fu!!y assessed. DOE is performing experimental studies at this time, and the effects of this impurity will have to be considered in any licensing assessment.
Source Terms A radioactive source term is used to assess offsite dose consequences from postulated reactor accidents. The source term is derived from a severe accident (i.e., an accident with core melt) or a group of severe accidents and is determined by the progression of the accident and the natural processes that retain fission products in the plant. The progression of the accident is affected by melting of the core, formation of crusts, expulsion of core debris from a breached vessel, hydrogen generation from metals, heat transfer to the containment, etc. The addition of a few percent extra plutonium in the core, with a reduction of only about 10 C in melting temperature, will not have a tHg effect on accident progression. Also, the processes that remove fission products, like sgglomeration, settling, and scrubbing by water, will not be affected by the small change in composition of the core debris. Further, the source term itself is given in terms of fractions of initial inventory, so these fractions should not be changed significantly. Only the gap release may increase (marginally) because of the elevated operating temperatures in MOX fuel compared with UO, fuel. The gap release is used in the analysis of design-basis accidents, but it will not have a large effect on severe accident source terms.
However, the consequences of a severe accident might change because the inventory of radionuclides is different. At any given time, MOX fuel will have more plutonium than UO, fuel, and the inventory of other actinides and fis ion products will also be somewhat different. Those changes could have an effect on offsite consequences. It can be noted, however, that consequences such as cancer fatalities are caused by a range of actinides and fission products, not just plutor. lum. The health consequences, which would depend on the type and amount of radionuclides inhaled or ingested, will have to'be assessed.
In addition to possible changes in consequences, the changes in reactor physics and fuel behavior discussed above could in principle have an effect on the probability of occurrence of a severe accident, and this should also be assessed. It should be noted, though, that the net outcome may not be obvious. For example, tiie discussion about reactivity initiated accidents i
suggests that the behavior of MOX fuel during an RIA may be worse than that of UO, fuel.
However, these reactivity accidents do not make a contribution to current risk assessments
7 1
13 l
because they are terminated by a natural process (Doppler feedback). From the discussion above about accident progression, it appears iikely that the probability of severe accidents will not change and that consequence analyses, rather than full probabilistic risk assessments, may be sufficient to assess the changes due to the different inventory of radionuclides.
Fuel Fabricatico Cecause plutsnium is a strong alpha emitter and its specific activity is much higher than uranium, a minute quantity of plutonium, if inhaled, could present a health hazard. Therefore, a MOX fuel fabrication facility will have remote handling requirements not found in uranium fabrication facilities, and these requ!rements need to be addressed prior to licensing. In addition, the design of a MOX fabrication facility will be subject to more stringent requirements than a uranium fuel fabrication facility. Required design criteria need to be evaluated and modified if necessary prior to any licensing actions.
There may be two issues related to criticality in the weapons-grade MOX fuel fabrication process. Becauss M is uncertain what the initial, intermediate, and final forms and compositions of the special nuclear material will be in the fabrication process, the first issue is that there may be a lack of publicly available peer reviewed critical experiments using those forms and compositions. Because it is also uncertain what the processing steps will be, the second issue is that there may be a lack of cross-section data for those forms and compositions at the' temperatures and energy ranges of interest (e.g., the resonance region). A study now being performed for NRC at Oak Ridge National Laboratory regarding the areas of applicability of critical experiments may help address this issue.
. Fuel Storace and Discosal it is expected that the final disposal of the spent MOX fuel will be in the geological repository for high level radioactive waste that is being studied and evaluated by DOE. Prior to that, if the i
MOX spent fuel needs to be stored in. dry storage instead of in a water pool, dry storage casks can be developed and then certified by the NRC. The staff has not identified any unique dry cask storage issues at this time.
Il CONCLUSION j
Experience in Europe with the technical and regulatory issues of using MOX fuel eggests that j
these issues can be resolved here as well. Nevertheless, the NRC and the U.S. it dustry must j
also deal with these issues, and some of the technicalissues will be unique because of the difference between weapons-grade MOX fuel and the reactor grade MOX fuel that is being used elsewhere.
l o
14 BIBLIOGRAPHY l
T. Abe, N. Nakae, K. Kodato, and M. Matsumoto," Failure behavior of plutonium-uranium mixed oxide fuel under reactivity-initiated accident condition," Joumal of Nuclear Materials,188, p.
154,1992.
H. Akutau and M. Koizumi," irradiation Performance Test of PuO2 UO2 Fuels by SAXTON l
Reactor," Proceedings of a Panel on Plutonium Utilization in Thermal Power Reactors, IAEA, Karlsruhe, November 25-29,1974.
A. A. Alsaed and M. Adams," Disposition of weapons-grade plutonium in Westinghouse reactors," ANRCP-1998-1, Amarillo National Resource Center for Plutonium, http://208.200.37.251/pdfs/z00865.pdf,1998.
i S. Aniel-Buchheit, R. Sancher, A. Puill, and M. Coste, " Plutonium Recycling in a PWR: MOX Fuel Characteristics Compared to Standard Uranium Fuel," Transactions of the American l
Nuclear Society,76, p.177,1997.
Y. A. Chao, et al.," Challenges to Nodal Diffusion Methods for Cores with Mixed Oxide Fuel,"
l Proceedings of the intemational Conference on the Physics of Nuclear Science and l
Technology, Vol.1, p. 9,1998.
l R. G. Cochran and N. Tsoulfanidis, "The Nuclear Fuel" cie: Analysis and Management,"
j l
American Nuclear Society,1990.
J DOE, " Status of Mixed Oxide Fuel Utilization," U.S. Department of Energy, February 1996.
DOE," Record of Decision for the Storage and Disposition of Weapons Usable Fisslie Materials," U.S. Department of Energy, January 14,1997.
M. D. Freshley, " Mixed-Oxide Fuel Irradiations in the Plutonium Recycle Test Reactor," Nuclear Technology,15, p.125,1972.
M. D. Freshley, D. W. Brite, J. L Daniel, P. E. Hart, and R. K. Marshall, "Plutonia Fuel Study,"
NP-637, Electric Power Research institute, January 1978.
G. Friedlander, J. W. Kennedy, E. S. Macias, and J. M. Miller, " Nuclear Radiochemistry," New York: John Wiley and Sons,1981.
R. R. Hart, et al., " Gallium Interactions with Zircaloy Cladding," ANRCP-1998 5,1998.
E. S. Lyman, "Public Health Consequences of Substituting Mixed-Oxide for Uranium Fuelin Light Water Reactors - Executive Summary," Nuclear Control Institute, http /www.ncl.org/moxsum.htm, January 21,1999.
1 NEA," Physics of Plutonium Recycling," Vo!. I, issues and Perspectives, OECD Documents, NEA,1995.
L
- ~ --
15 NEl, Industry Presentation on the Use of MOX Fuel, U.S. NRC Auditorium, February 21,1997.
NRC," Final Generic Environmental Statement on the Use of Recycle Plutonium in Mixed Oxide Fuel in Light Water Cooled Reactors," NUREG 0002, U.S. Nuclear Regulatory Commission, August 1976.
NRC, " Annual Report 1977," U.S. Nuclear Regulatory Commission, Washington, DC, j
NUREG 0400, p. 45-47,1978.
j i
NRC, "TIP40: Mixed Oxide Fuel (Plutonium Disposition)," U.S. Nuclear Regulatory Commission Web page, http://www.nrc. gov /OPA/,1999.
l W. L. Orr," Westinghouse PU Recycle Experience and Des'gn," Proceedings of the Topical Meeting on the Piutonium Fuel Cycle, ANS, Bal Harbour, FL, May 2-4,1977.
1 J. Papin and F. Schmitz, "The Status of the CABRI - REP-Na Test Programme: Present Understanding and Still Pending Questions," Proceedings of the USNRC 25th Water Reactor Safety informatior, Meeting, NUREG/CP-0162, vol. 2, p.199,1998.
W. R. Smalley, "Saxton Core ll Fuel Performance Evaluation," WCAP-3385-56, Westinghouse, September 1971.
L. Soffer, S. B. Burson, C. M. Ferrell, R. Y. Lee, and J. N. Ridgely, " Accident Source Terms for Light-Water Nuclear Power Plants," NUREG-1465, U.S. Nuclear Regulatory Commission, February 1995.
W. G. Sutcliffe, et al., "A Perspective on the Dangers of Plutonium," Lawrence Livermore National Laboratory, www.llnl. gov /csts/ publications /sutcliffe/118825.html, April 14,1995.
J. A. Tumbull,"A Review of MOX Fuel and its use in LWRs," Report HWR 435, OECD Halden Reactor Project, November 1995. (Limited Distribution).
D. L. Williams, Jr., " Licensing issues Associated with the Use of Mixed-Oxide Fuel in U.S.
Commercial Nuclear Reactors," ORN!JTM-13421,1997.
D. F. Wilson, et al., " Potential Effects of Gallium on Cladding Materials,"
http://www.om!. gov /etd/FMDP/ORNLPublications.html, ORNIJTM-13504,1997.
--- _ _..._.