1 PORTLAND GENERAL ELECTRIC COMPANY THE CITY OF EUGENE, OREGON PACIFIC POWER AND LIGHT COMPANY i
DOCKET N0. 50-344 TROJAN NUCLEAR PLANT AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 129 License No. NPF-1 l
1.
The Nuclear Regulatory Comission (the Comission) has found that:
A.
The application for amendment by Portland General Electric Company, et al., (the licensee) dated October 17, 1986, as supplemented TiniTiry 14, 1987, complies with the standards and requirements of j
the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of l
the Comission; 1
j C.
There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health J
i and safety of the public, and (ii) that such activities will be
{
conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and i
E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements a
]
have been satisfied.
]
i l
8704290263 870422 f,DR ADOCK 05000344 1
l'DR
-v..
a
,a
--e,-
g-a
-n.-----,
.av
- n. - - - -
--.---.-----,,,..,.r.---m.--
.-nr.
-,,-.----.-a--
e--,-,w--
_ -~
...uaca I
i i
! 2.
Accordingly, the license is amended by changes to the Technical i
Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-1 is hereby amended to read as follows:
(2) Technical Specifications t
The Technical Specifications contained in Appendices A 4
and B, as revised through Amendment No. 129, are hereby incorporated in the license. The licensee shall operate the facility in ac'cordance with the Technical Specifica-tions, except where otherwise stated in specific license conditions.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY COMMISSION
\\
/
/
George y Knighton,,
rector Project Directorat -Y Division of Reactor Projects-III/IV/V and i
Special Projects i
j
Attachment:
Changes to the Technical j
Specifications i
Date of Issuance:
April 22, 1987 I
4 I
+
i l
i l
j l
i l
i i
I
..-.._,._.--.,,_..m....,,_,__,_
,, _ -. ~. -, _ _., -,, -.
/'se a n c go, UNITED STATES
[ j 3,..f( h NUCLEAR REGULATORY COMMISSION
-en '-" //
WASHINGTON, D C. 20555 S,k.h.k. C i
p ATTACHMENT TO LICENSE AMENDMENT N0. 129 TO FACILITY OPERATING LICENSE N0. NPF-1 DOCKET NO. 50-344 Revise Appendix A as follows:
Remove Page Insert Page TS 3/4 6-15 TS 3/4 6-15
l CONTAINMENT SYSTEMS 3/4.6.3 CONTAINMENT ISOLATION VALVES LIMITING CONDITION FOR OPERATION 3.6.3.1 The containment isolation valves specified in Table 3.6-1 shall be OPERABLE with isolation times as shown in Table 3.6-1.
APPLICABILITY:
MODES 1, 2, 3 and 4.
1 ACTION:
With one or more of the isolation valve (s) specified in Table 3.6-1 inoperable, either:
a.
Restore the inoperable valve (s) to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, or b.
Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least one deactivated automatic valve secured in the isolation position, or Isolate each affected penetration within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of i
c.
at least one closed manual valve or blind flange; or d.
Be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
SURVEILLANCE RE0UIREMENTS I
4.6.3.1.1 The isolation valves specified in Table 3.6-1 shall be demon-strated OPERABLE prior to returning the valve to service af ter maintenance, repair or replacement work is performed on the valve or its associated actuator, control or power circuit by performance of a cycling test and l
verification of isolation time.
4.6.3.1.2 Each isolation valve specified in Table 3.6-1 shall be demon-strated OPERABLE at least once per 18 months by:
a.
Verifying that on a containment isolation test signal, each isolation valve actuates to its isolation position.
i TROJAN-UNIT 1 3/4 6-15 Amendment No. 14, 129
--