's e

Consumers POWar pensasus N PR M AE55 General Offices: 212 West Michigen Avenue, Jackson, MI 40201 + (517) 788-0650

-July 10, 1986 James G Keppler, Administrator Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR P LIEIEbkANT -

RESPONSE TO INSPECTION REPORT 86-011 OPEN ITEM 50-255/86011-01 In response to NRC Open Item 50-255/86011-01, the following are the results of the analysis of an unknown sample from the NRC. The results do not include analyses for Sr-89 and Sr-90, as they were inadvertently lost at the off-site vendor's facility.

The results were obtained by analysing 10 milliliter of the unknown sample on Detector #2 (CPCo #8428-00039). The percent error from the spectral printout is provided in parentheses following the activity for each isotope. Activity is reported in microcuries per milliliter. The sample was " decay corrected" to 0800, January 11, 1986, and analysed on April 7, 1986, at 1057 EST.

Isotope Ac_tivity Mn-54 6.1 E-5 pei/ml (8)

Co-60 7.4 E-5 pei/ml (7)

Cs-137 9.3 E-5 pci/ml (5)

Secondly, per Open Item 50-255/86011-01, a sample from Clean Waste Receiver Tank T-64A was collected on April 22, 1986 at 1750 EST and split with the NRC.

The sample was analysed on both Detector #2 and on Detector #3 (CPCo #8428-00158). The percent error from the spectral printout is provided in parenthe-ses following the activity for each isotope. Activity is reported in microcuries per milliliter.

/$

OC0786-0112-NLO2 i O 1

8609090003 860710 JUL 14 Jggg PDR ADOCK 05000255 G

PDR

c

.e Administrator, R gion III 2

Palisades Plant Responselto IEIR 86-011 Open Item 50-255/86011-01 July 10, 1986 Isotope Activity Detector #2 Activity Detector #3 Cc-58 3.7 E-5 pei/ml (4) 3.1 E-5 pei/ml (4)

Co-60 1.8 E-5 pei/ml (7) 2.1 E-5 pci/ml (6)

Mn-54 4.0 E-6 pei/ml (17) 5.7 E-6 pci/ml (11)

Cs-134 2.1 E-5 pei/ml (5) 1.5 E-5 pei/ml (8)-

Cs-137 5.8 E-8 pei/ml (3) 4.2 E-5 pci/ml (4)

Cr-51 8.7 E-6 pci/ml (56).

N/A Ba-140 1.6 E-5 pci/ml (25)

N/A Additionally, the Sr-89 and Sr-90 analysis from a 1515 EST March 12, 1986 sample of Clean Waste Receiver Tank T-64A is included in response to a verbal request from Dr RBHoltzman.

Isotope Activity Sr-89

<0.9 picoeuries per milliliter Sr-90

<0.8 picocuries per milliliter C A.

Brian D Johns a Staff Licensing Engineer CC Director, Office of Nuclear Reactor Regulation Director, Office of Inspection & Enforcement NRC Re:ident Inspector - Palisades i

OC0786-0112-NLO2