o f
MAR 121987 dhQ g ig gy:.-
5 Docket Nha'50-285 DISTRIBUTION
{ Uocket File)
BGrimes
,t' l
ims VUK JPartlow L.POR NThompson Mr. R. L. Andrews PBD#8 Rdg Gray File Division Manager
' Nuclear Production FMiraglia PKreutzer Gmaha Public. Power District OGC-Beth WPaulson
'1623 Harney Street' ACRS-10 LKopp Omaha, Nebraska 68102 EJordan
Dear Mr. Andrews:
SUBJECT:
ULTRASONIC FUEL INSFECTION IN THE SPENT FUEL POOL The NRC staff has completed its review of your February 13, 1987 submittal 1,
regarding your plans to perform ultrasonic inspection of fuel assemblies in
~' '=
test equipment located in the cask loading area'of the Fort Calhoun spent fuel pool.' Your submittal requested the staff to modify its September 9, 1983 safety evaluation to allow, bypassing of the refueling machine interlock to allow the temporary transfer of fuel. assemblies in and out of Region 2 of the spent fuel pool during refueling outages for the purpose of inspecting the fuel assemblies.
The staff's Safety. Evaluation is enclosed.
The staff concludes that the tepparary transfer of discharged fhel assemblies to the test equipment in the cask loading area of the spent fuel pool for p
e' inspection during refueling outages is acceptable.
In addition' fuel l assemblies being permanently discharged may remain in the Region 2 spent fuel-racks provided that the re' quired burnup verification has been performed.
Sincerely, Original Wgnmo W a
Walter A. Paulson, Project Manager PWR Project Directorate #8 Division of PWR Licensing-B
Enclosure:
Safety Evaluation cc w/ enclosure:
See next page 8703190539 870312 j
PDR ADOCK 05000285 G
PDR PBD#8 o
PBD#8 PK % zer W
don;cf AThadani g
3/ 4 /87 3/g/87 3//2/87
, ft y
?
v
{
Mr. R. L. Andrews Fort Calhoun Station Omaha Public Power District Unit No. 1 cc:
Narry H. Voigt, Esq.
LeBoeuf Lamb, Leiby & MacRae 1333 New Hampshire Avenue, NW Washington, D.C.
20036 Mr. Jack Jensen, Chairman Washington County Soani of Supervisors Blair, Nebraska 68008 Mr. Phillip Harrell, Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 309
,, /
Fort Calhoun, Nebraska 68023 Mr. Charles 8. Brinkman, Manager Washington Nuclear Operations C-E Power Systems 7910 Woodsont Avenue Bethesda, Naryland 20814 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Office of Executive Director for Operations 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Harold Borchert, Director Division of Radiological Health l f Department of Health 301 Centennial Mall, South P.O. Box 95007 Lincoln, Nebraska 68509 L