Text
n.
N MAR 5 N Docket No. 50-331 Iowa Electric Light and Power Company ATTN: Mr. Lee Liu President and Chief Executive Officer IE Towers P. O. Box 351 Cedar Rapids, IA 52406 Gentlemen:
SbBJECT: EQUIPMENT QUALIFICATION INSPEC110N DUANE ARNOLD ENERGY CENTER This letter confirms the dates of April 13-17, 1987, for the NRC_Ed8 N tM Qualification'(EQ) Inspection of electrical and instrumentation equipment, at the Duane Arnold Energy Center. These dates were established during a January 28, 1987, telephone conversation betweten Mr. S. Swails of your staff' and Mr. A. S..Gautam of my staff. The inspection will be performeo by a six mcrber inspection team with Mr. A. S. Gautam of the Region III office as lead.
inspector.
The following areas will be inspected:
Implementation of corrective action consnitments addressed in the final Duane Arnold EQ Safety Evaluation Report.
Compliance to EQ regulations of 10 CFR 50.49, including Program Procedures, Master Equipment List, Maintenance, Procurement, Upgrading of Replacement Equipment, Quality Assurance and Employee Training.
Adequacy of equipment qualification files, including responses to relevant NRC Informdtion Notices and Dulletins.
Installation and maintenance of selected plant EQ equipment.
A management entrance meeting is scheduled for 2:00 p.m. on April 13, 1987, at the plant site. A plant walkdown inspection of selected EQ equipment is scheduled for April 15, 1987, and an NRC exit meeting is scheduled for 11:00 a.m. on April 17, 1987. To facilitate NRC preparation for this inspection, Mr. Swails of your staff has been requested to submit the following Duane Arnold EQ' documents no later than March 27, 1987.
'1.
Licensee's response to Generic Letter 84-24 (D. G. Eisenhut to licensea's and applicants dated December 27, 1984;
Subject:
Certification of i
Complianceto10CFR50.49).
I p
JcA1
.s".
-+
y Iowa Electric' Light and 2
Power Company.
2.
a) ~ Licensee's list of equipment requiring EQ (Master List submitted in May 1983).
b)
Master List, version in effect at the time of the inspection.
- c)
Licensee's current System Component Evaluation Worksheets'(SCEW Sheets).
3.
Licensee's procedures applicable to EQ (EQ Program, procurement of qualified equipment, maintenance of qualified equipment, and modifica-tions to plant that could affect qualified equipment).
4.
Final NRC EQ SER issued to the plant, and any appropriate licensee responses to.the SER.
The licensee is requested to make a presentation at the entrance meeting to address:
a..
Organization Chart with EQ applicability.
b.
Overview of EQ' Program, c.
Overview of EQ documentation file organization including how files address meeting EQ criteria (10 CFR 50.49,-DOR, NUREG 0588) required instrument accuracy, submergence, as applicable.
d.
Arrangements for plant walkdown (the NRC team leader will identify samples selected at the entrance).
Your cooperation with us during this inspection will be appreciated. Should you have any questions regarding this inspection, please contact r
Mr. R. N. Gardner at (312) 790-5763 or Mr. A. S. Gautam at (312) 790-5523.
Sincerely,
[cicidl[SiddiLf'C J, Mrf }MH(
N. J. Chrissotimos, Acting Director Division of Reactor Safety L
See Attached Distribution i
RSII R!ll R111
/
RI Yg l
MGr Wr Gautam/jk Gardner H rrison Ch ssotiros f
03A /87 03/6/87 l
03/02/87 03/o6/87 03/6( /87 i
. ~
m 4
Iowa Electric Light and 3
AMR 5 1987 Power Company Distribution D. Mineck, Plant Superintendent Kuclear W. Miller, Assistant Plant Superintendent Technical Support DCS/RSB (RIDS)
Licensing Fee Management Branch Resident Inspector, RIII Thomas Houvenagle, Iowa State Convaerce Comission