r OPERATING DATA REPORT DOCKET No.

50-443 DATE 01/08/87 CGIPLETED BY R.

Cout ur e TEIEPHONE (603) 4 74-9521 (Ex t. 4077)

OPERATING STATUS 1.

Unit Name:

Seabrook Station Unit 1 2.

Reporting Period:

Decenber 1986 3.

Licensed Thermal Power (Wt):

3411 4.

Nameplate Rating (Gross We):

1197 5.

Design Electrical Rating (Net We):

1148 6.

Maximtsn Dependable Capacity (Gross Wo):

1197 (Initial design value) 7.

Maximum Dependable Capacity (No t We):

1148 (Initial design value) 8.

If Changes Occur in Capacity Ratings (Items Number 3 Through 7)

Since Last Report, Give Reasons:

Not Applicable 9.

Power Level To Which Restricted, if Any (No t We):

?.aro power

10. Reasons For Restrictions, If Any:

Lic en sa issued on 10/17/86 is a zero powe licenso dtich allows fuel loading and performance of non-nuclear testing.

This Month Yr. -to-Da te Cumulative

11. Hours In Reporting Period

_7,44.0 1825.0 1825.0

12. Number Of Ilours Reactor Was Critical 0.0 0.0 0.0
13. Reactor Raserve Shutdown llaurn
0. 0 0.0 0.0
14. Ilours Generator On-Line 0.0 0.0 0.0

~

15. Unit Reserve Shutdown llaurs
0. 0 0.0 0.0
16. Cross Thermal Energy Generated (Wil) 0 0

0

17. Cross Elec. Energy Generated (Wil) 0 0

0

18. No t Electrical Energy Conorated (Wil) 0 0

0

19. Un it Se rv ic e Fac to r 0.0 0.0 0.0
20. Unit Availability Factor 0.0 0.0 0.0
21. Unit Capacity Fac tor (Using MDC No t) 0.0 0.0 0.0
22. Unit Captcity Factor (Using DER Na t) 0.0 0.0 0.0
23. Unit Forcel Outage Ra te

_ _0. 0 0.0 0.0

24. Shutdowns Scheduled Over Next 6 Months (Type, Ihte, and Duration of luch):

No t Sc hed u_1 ed

25. If Shut IMwn At End Of iks port Pe r tod, Estimated Da te Of Star Cup t No t Applicablo 2 6. Unit s in Te st Status (Prior to Commercial Operation):

Fo recast Achieval INITIAL CRITICALITY

_ 1987,

No t Applic abl o No t Applienble INITIAL. ELECTRICITY

___1987 CGlHCRCIAI. OiY. RATION 1981 No t Applicabt o R

U

%,h f

n AVERAGE MILY UNIT POWER IRVEL DOCKET N0.

50-443 UNIT Seabrook 1 DATE 01/08/87 C(MPLETED BY R.

Co ut ure TEIEPHONE (603) 474-9521 (Ext. 4077)

M0lffH DECIM BER, 1986 DAY AVERAGE MILY POWER IEVEL MY AVERAGE MILY POWER 1RW.L (We-Ne t)

(We-Ne t) 1 0

16 0

2 0

17 0

3 0

18 0

i 4

0 19 0

5 0

20 0

6 0

21 0

7 0

22 0

8 0

23 0

9 0

24 0

10 0

25 0

11 0

26 0

12 0

27 0

13 0

28 0

14 0

29 0

15 0

30 0

31 0

INS'mVCT10N3 On this format, list this average daily unit p>wr level in leio-Net for each day in the rep >rting month. 0)mpute to the nearest idiole megawa tt.

i E

u

1 DOCKET E 50-443 UNIT SHUIDOWNS AND 10WER REDUCTIONS INIT NAME Seabrook 1 DATE 01/08/87 C(MPLETED BY R.

Cout ure REPOP.T MONTH EC EM BER, 1986 TEIEPHONE (603) 474-9521 (Ext. 4077)

T pe Duration Reason 2 Me thod of Licensee Cause & Corrective l

No. Da te f

(Hours)

Shutting Event Action to Ibwn Reactorl Report #

Prevent Recurrence NO ENTRIES FOR THIS MOTrH I

2 3

F: Fo reed Reason:

Me thod :

S:

Scheduled A-Equipsent Failure (Explain) 1-Manual B-Maintenatee or Te st 2-Manual Scran C-Re f teling 3-Automatic Scras D-Regulatory Restriction 4-Continued fros EM)perator Training & License Exasination previous month F-Administrative 5-Power Reduction G-operational Error (Explain)

(Duration = 0)

H-Other (Explain) 94)ther (Explain)

Docket No.

50-443 Data 01/08/87 Unit Name Seabrook 1 Completed By it. couture Telephone (603) 474-9521 (Ext. 4077)

CORRECTIVE MAINTENANCE SIMMARY FOR SAFETY RELATED EQUIPMENT Page 1 of 1 REPORT MONTH DECEMBER, 1936 DATE SYSTEM COMPONENT MAINTENANCE ACTION 12/18/86 Radiation RM-6482 Replaced failed power supply.

Monitoring C Main Steam Line Monitor 12/19/86 Containment CAP-V-3 Valve binding due to failed Air Purge Exhaust Flow Isolation bearings. Repaired.

(ADV Inside Contain: ment)

I

Docke t-No.

'50-443 Data t-

-01/08/87 Completed By:-

R. Couture U

Telephone:

(603) 474-9521 (Ext. 4077)

' REFUELING INFORMATION REQUEST.

1. Name of facility:

Seabrook Unit 1

.2.. Scheduled 'date for next refueling shutdown: Not Scheduled

3. Scheduled date - for restart following refueling: Not Scheduled
4. Will refueling or resumption of operation thereafter require a technical.

specification change or other license amendment?

Unknown at this time..

5. Scheduled date(s) for submitting licensing action and supporting information:

Not Applicable

6. Important licensing considerations associated with refueling, e.g.,

new or different fuel design or supplier, unreviewed design or performance analysis methods, significant changes in -fuel design, new operating procedures None i

7. Se number of fuel assemblies (a) in the core and (b) 'in the spent fuel storage pool:

(a) In Core:

193 (b) 0 i

8

8. De present licensed spent fuel pool storage capacity and the size of any increase in licensed storage capacity that has been requested or is planned, in nsaber of fuel assemblies:

Present licensed capacity:

1236 No increase in storage capacity requested or planned.

9. We projected date of the inst refueling that can be discharged to the spent fel pool assiseing the present licensed capacity kh Licensed capacity of 1236 f uel assemblies based on sixteen refuelings and full core offload capability.

The current licensed capacity is adequato initil at least the year 2 007.

n George S. Thomas vice Prendent-Nuclear Produchon Put$c Servios of New Hampshire New Hampshire Yankee Division NYN-87003 January 9,1987 United States Nuclear Regulatory Commission Washington, DC 20555 Attention: Document Control Desk

Reference:

(a) Facility Operating License No. NPF-56, Docket No. 50-443 Subj ect: Monthly Operating Report

Dear Sir:

In accordance with Technical Specification Section 6.8.1.5, enclosed please find Monthly Operating Report 86-12 covering the operation and shutdown experience relating to Seabrook Station Unit 1.

Very truly yours, g(jf

_b.. org

. Thomas Enclosure cc: Regional Administrator U.S. Nuclear Regulatory Commission - Region I 631 Park Avenue King of Prussia, PA 19406 Mr. A. C. Cerne NRC Senior Resident Inspector Seabrook Station Seabrook, NH 03874 6l f( {

P.O. Box 300. Seabrook, NH 03874. Telephone (603) 474 9574

- _....