o e

APPENDIX A NOTICE OF VIOLATION GPU Nuclear Corporation Docket 50-289 Three Mile Island Nuclear Station License No. DPP-50 Unit 1 As a result of the inspection conducted on October 20-24, 1986, and in accor-dance with the General Statement of Policy and Procedures for NRC Enforcement Actions, 10 CFR Part 2, Appendix C (Enforcement Policy 1986), the following violation was identified:

Section 6.9.5.2 of the Unit 1 Technical Specifications states that "The radioactive effluent release report to be submitted 60 days after January 1 of each year shall include... an assessment of the radiation doses from radioactive liquid and gaseous effluents to individuals due to their activities inside the site boundary during the report period."

Contrary to the above, the report submitted on February 28, 1986, did not include an assessment of doses from effluents to individuals due to their activities inside the site boundary.

This is a Severity Level V Violation (Supplement I).

Pursuant to the provisions of 10 CFR 2.201, GPU Nuclear Corporation is hereby required to submit to this office within thirty days of the date of the letter which transmitted this Notice, a written statement or explanation in reply, including (1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further violations; and, (3) the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending this response time.

0701140056 070107 PDR ADOCK 05000289 G

pyg 0FFICIAL RECORD COPY IR THIl 86 0004.0.0 01/07/87

- -