Proposed Tech Specs,Changing Ref Point Used to Establish Refueling Platform Main Hoist Downtravel Cutoff Setpoint
ML20207L221
Person / Time
Site: Grand Gulf 
Issue date: 10/10/1988
From:
SYSTEM ENERGY RESOURCES, INC.
To:
Shared Package
ML20207L219 List:
References
NUDOCS 8810170233
Download: ML20207L221 (1)


Text

- _ _ _

NL 88/a

'R'NUELINGOPERATIONS 3/4.9.6 REFUELING EQUIPMENT REFUELING PLATFORM LIMITING CONDITION FOR OPERATION 3.9.6.1 The refueling platform shall be OPERABLE and only the main hoist shall be used for handling fuel assemblies.

APPLICABILITY:

During handling of fuel assemblies or control rods in the primary containment with the refueling platform.

ACTION:

With the requirements for refueling platfern OPERABILITY not satisfied, suspend use of any inoperable refueling platform equipment from operations involving the handling of fuel assemblie', or control rods after placing the toad in a safe condition.

SURVEILLANCE REQUIREMENTS 4.9.6.1 Each refueling platform hoist to be used for handling fuel assemblies or control rods shall be demonstrated OPERABLE within 7 days prior to the handling of fuel assemblies or control rods:

In the containment fuel pool, reactor cavity or reactor pressure a.

vessel by:

1.

Demonstrating operation of the slack cable cutoff on the main hoist when the total cable load is 50110 pounds.

2.

Demonstrating operation of the grapple engaged loaded interlock on the main hoist before the total cable lead exceeds 535 pounds.

1 3.

Demonstrating operation of the jam cutoff on the main hoist before the total cable load exceeds 1250 pounds.

4.

Demonstrating operation of primary and redundant overload cutoff on the auxiliary hoists before the load exceeds 550_ pounds._ _

b.

In or over the reactor pressure vessel by:

hi'.dinch'above'the]

.~ tep guide. g Demonstratingoperationofthedowntravgelcutoffon'themain 1.

yst when the bottom of the gragle is

{ 0. { hdu be6

.u.

.vy v.

.u.

........9 n.uvi,

.n

.u.

...uv i svis.

2.

Demonstrating operation of the primary and redundant fuel load interlocks on the main hoist before the total cable load exceeds 600 pounds.

8810170233 881010 PDR ADOCK 05000416 P

PNU LdND GULF-UNIT 1 3/4 9-8 Amendme nt No,