Text
- ,Jaad g
8 4't UNITED STATES NUCLEAR REGULATORY COMMISSION
,E WASHINGTON, D. C. 20555
' \\...../
DEC 3119E Docket Nos.:
50-445 and 50-446 Mr. William G. Counsil Executive Vice President Texas Utilities Generating Company Skyway Tower,l..B. 81 400 North Olive Street Dallas, Texas 75201
Dear Mr. Counsil:
SUBJECT:
COMANCHE PEAK CORRECTIVE ACTION PROGRAM In order for the NRC staff to efficiently schedule inspections that will focus on your corrective action programs, we request:
1.
A list of the discrete program components of each corrective action plan (e.g., high energy line break, systems interactions, fire protection, etc.); the organization that is conducting the work (e.g., SWEC, Ebasco, Impell, etc.);
the location where the work is being performed (e.g., NY, Boston, Chicago, etc.).
2.
A current schedule of completion of work for the various program components; a point of contact.
3.
A list of products that will be produced as a result of the corrective action plans and documentation available to be reviewed.
4.
Plans for design verification of any redesign /requalification work that may arise from recently initiated SWEC work.
5.
An explanation of the relationship between generic issue reports and issue resolution reports.
It is our understanding that both are to document planned corrective actions and evaluations by TERA of these plans.
8701090241 861231 PDR ADOCK 05000445
&9 PDR
s We reouest that you respnnd to this request in writing within 30 days of the date of this letter.
Should you have any questions or need further clarification, please call Annette Vietti-Cook, Project Manager at (301) 492-8525.
Sincerely,
/
Ad Mnt' No n,
or PWR Pro.je t Directorate No. 5 Division of PWR licensing-A a
b i
i
't
-,-.-n-.
r, e,---
n---
pw We request that you respond to this request in writing within 30 days of the date of this letter.
Should you have any questions or need further clarification, please call Annette Vietti-Cook, Project Manager at (301) 492-8525.
Sincerely,
/s Vincent S. Noonan, Director PWR Project Directorate No. 5 Division of PWR I.icensing-A a
See previous concurrence Distribution
('
- Docket File E. Jordan ACRS (10)
NRC PDR B. Grimes l.ocal PDR J. Partlow
/
[}
PDAS R/F N. Thorrpson V, Noonan A. Vietti-Cook
/
l 0El.D M. Rushbrook PD#h[ f PDf h PDff pcf IE DIR:
A M ook:ss kFi IP DNorkin VSNoonar 12f/86 12/g 86 12/ /86 12/ 86 inq h
v.lA,fku
( Abu.3 Id[M/6 6 kq~ms A...A py/y.
Q =.
W. G. Counsil Comanche Peak Steam Electric Station 5
Texas Utilities Generating Company Units 1 and 2 CC:
Nicholas S. Reynolds, Esq.
Resident Inspector / Comanche Peak Bishop,l.iberman, Cook, Steam Electric Station Purcell & Reynolds c/o U.S. Nuclear Regulatory Commission 1200 Seventeenth Street, NW P. O. Box 38 Washington, D.C.
20036 Glen Rose, Texas 76043 Robert A. Wooldridge, Esq.
Regional Administrator, Region IV Worsham, Forsythe, Sampels &
U.S. Nuclear Regulatory Commission Wooldridge 611 Ryan Plaza Drive Suite 1000 2001 Bryan Tower, Suite 2500 Arlington, Texas 76011 Dallas, Texas 75201 1.anny A. Sinkin Mr. Homer C. Schmidt Christic Institute Manager - Nuclear Services 1324 North Capitol Street Texas Utilities Generating Company Washington, D.C.
20002 Skyway Tower 400 North Olive Street,t..B. 81 Ms. Billie Pirner Garde Dallas, Texas 75201 Government Accountability Project Midwest Office Mr. Robert E. Ballard, Jr.
3424 N. Marcos 1.ane Director of Projects Appleton, WI 54911 Gibbs and Hill, Inc.
11 Pen Plaza New York, New York 10001 David R. Pigott, Esq.
Orrick, Herrington & Sutcliffe 600 Montgomery Street Mr. R. S. Howard San Francisco, California 94111 Westinghouse Electric Corporation P. O. Box 355 Anthony 7. Roisman, Esq.
Pittsburgh, Pennsylvania 15230 Trial I.awyers for Public Justice 2000 P. Street, NW Renea Hicks Esq.
Suite 611 Assistant Attorney General Washington, D.C.
20036 Environmental Protection Division P. O. Box 12548 Capitol Station Nancy E. Wiegers Austin, Texas 78711 Spiegel & McDiarmed 1350 New York Avenue, NW Mrs. Juanita Ellis, President Washington, D.C.
20005-4798 Citizens Association for Sound Energy 1426 South Polk Roy P. I.essy, Jr.
Dallas, Texas 75224 Wright & Talisman, P. C.
1050 Seventeenth Street, NW Ms. Nancy H. Williams Suite 600 CYGNA Washington, D.C.
20036-5566 101 California Street San Francisco, California 94111 n.
--r,
Texas Utilities Electric Company Comanche Peak Electric Station Units I and 2 CC*
Resident Inspector - Comanche Peak Joseph F. Fulbright c/o U.S. Nuclear Regulatory Commission Fulbright & Jaworski P. O. Box 1029 1301 McKinney Street Granbury, Texas 76048 Fouston, Texas 77010 Mr. John W.' Beck
^
Vice President Texas Utilities Generating Company Skyway Tower 400 N. Olive Street,l.B#81 Dallas, Texas 75201 Mr. Jack Redding 1
C/0 Oatel Service Corp.
Texas Utilities Generating Company 7910 Woodmont Avenue, Ste. 208 Bethesda, Maryland 20814 William A. Burchette, Esq.
Counsel for Tex-l.a Electric Cooperative of Texas Heron, Burchette, Ruckert & Rothwell Suite 700 1025 Thomas Jefferson Street, NW 4
Washington, D.C.
20007 GDS Associates, Inc.
2525 Cumberland Parkway Suite 450 Atlanta, Georgia 30339 Administrative Judge Peter Bloch U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Elizabeth B. Johnson Administrative Judge Oak Ridge National I.aboratory
.1 P. O. Box X Building 3500 Oak Ridge, Tennessee 37830 Dr. Kenneth A. McCollom 1107 West Knapp Stillwater, Oklahoma 74075 Dr. Walter H. Jordan 881 Outer Drive Oak Ridge. Tennessee 37830
_