- sc DUKE POWElt GOMPANY P.O. nox 33180 CllARLOTTE, N.O. 28242 IIALH. TUCKER TEMMME vws PBESLDE5.T strous emooreview '
t August 15, 1988 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 1
Subject:
Duke Power Company Oconee Nuclear Station Docket Nos. 50-269, -270, -287 McGuire Nuclear Station Docket Nos. 50-369, -370 Catawba Nuclear Station Docket Nos. 50-413, -414 Gentlemen:
Pursuant to 10CFR 50.55a(3), this letter is to inform you of Duke Power Company's intention to incorporate code case N-401-1 of the ' ASME Boiler and Pressure Vessel Code into the Inservice Inspection Programs at the Duke Power nuclear stations.
A copy of the Code Case is attached to this letter.
Code Case N-401-1, Eddy Current Examination, has not received generic approval for use by the NRC as of Revision 6 of Rer ~ 'ory Guide 1.147. This code case specifies that, when demonstrated equiva*
to the Authorized Nuclear Inser-vice Inspector, digitized collection and storage of eddy' current' test ' data may be used as an alternative to magnetic tape and strip chart recording of eddy current test data required by Section XI, Division 1, Appendix IV.
Periodic i
calibration in accordance with IV-3000 is required only for the analog elements of the digital eddy current data co.11ection and storage equipment.
Duke Power Company intends to use code case N-401-1 unless informed by the NRC Staff that it is not acceptable for use.
)
[ON I(
Oh9 800015
- [C G
05000249 gl$t?Wp i
PNu 1
.s Docum:nt Control Dsak August 15, 1988 Page 2 3
Pursuant to 10CFR 170.21 a check for $150.00 is attached.
Very truly yours, MM Hal B. Tucker HBT/DM/190/jge Attachment xc:
Dr. J. Nelson Grace Regional Administrator U.S. Nuclear Regulatory Commission - Region II 101 Marietta St. NW Suite 2900 - Atlanta, GA 30323 Mr. W. T. Orders NRC Resident Inspector McGuire Nuclear Station Mr. P. K. Van Doorn NRC Resident Inspector Catawba Nuclear Station Mr. P. H. Skinner NRC Resident Inspector Oconee Nuclear Station
1
..o CASE N-40.1 - 1 CASES OF ASME BOILER AND PRESSURE VESSEL CODE Approval Date: Febewery 20,1984 s
See NumerkalIndex for expiration and any reeffirmation doene.
cue N 4011 Eddy Current Examination Section XI, Division 1 i
Inquiry: Is it permissible, as an alternative to the Sec-tion XI, Division 1, Appendix IV, requirement for mag.
netic tape and strip chart recording of eddy current test data, ta use digitized collection and storage of data as the permanent record for eddy current examinations, and to what extent do the calibration requirements of IV.3000 apply?
Replyt It is the opinion of the Committee that, when demonstrated equivalent to the Authorized Nuclear Inservice inspector, digitized c'ollection and storage of eddy current test data may be used as an alternative to magnetic tape and strip chart recording of eddy current test data required by Section XI, Division 1, Appendix IV. Periodic calibration in accordance with IV-3000 is required only for the analog elements of the digital eddy current data collection and storage equipment.
sUPP. 9 - NC
.