hk, HOUSTON UGHTING & POWER COMPANY SOUTH TEXAS PROJECT ELECTRIC CENERATING STATION 60SAE TELEPHONE MINUTES 60N99 I

COR RESPONDENCE SERI AL NUMBER TO:

M. R. Wisenburg ST-HL-HL-35794 FROM:

M. E. Powell SUBJECT FILE NUMBERS

/

DATE OF CALL:

July 2, 1986 PRIMARY: C25 SECONDARY -

SUBJECT:

SER Confirmatory Item #9 - Momentary Fuel Assembly Liftoff TELECON PARTICIPANTS:

(INCLUDE NAME AND Shih-Lieng Wu (USNRC)

ORGANIZATION OF EACH)

P. Kadambi (USN C)

M. E. Powell (HI4P)

PAGE 1 OF 2

Shih-Lieng Wu (USNRC) contacted me regarding H14P's letter of May 23, 1986 (rnference ST-HL-AE-1668) which provided supplemental information concerning momentary fuel assembly liftoff. This item is an SER confirmatory item.

Specifically, Mr. Wu stated that he needs a paracraph or two which provides, for example, the fuel assembly weight, the value of the hold down spring force, the amount of expected deflection and the results of the analysis (i.e. how big is the liftoff force).

In addition, a statement should be made that based on the values above, that the analysis shows that there is sufficient margin that the liftoff force will not uplift the fuel assembly.

Mr. Wu emphasized that he was not requesting detailed tables with the requested information and the he only wanted this information written in a paragraph or two.

He stated that Westinghouse (H) has provided something similar on other subjects.

Subsequent to the conversation with Mr. Wu, I contacted Bruce Lorenz (H) and briefed him on the conversation with the NRC.

Bruce will coordinate within W getting the requested information. He will contact me on July 7, 1986 with a schedule for responding.

Mbt'/yd 8607220595 860702

{DR ADOCK 05000498 PDR L1/Telmin/pa STP-103 (6-79)

HOUSTON UGHTihG & POWER COMPANY SOUTH TEXAS PROJECT ELECTRIC CENERATING STATION TELEPHONE MINUTES CORRESPONDENCE SERI AL NUMBER TO:

M. R. Wisenburg ST-HL-HL-35794 F'J.OM :

M.

E.

Powell SUBJECT FILE NUMBERS DATE OF CALL:

July 2. 1986 PRIMARY: c9 s SECONDARY-

SUBJECT:

SER Confirmatory Item #9 - Momentary Fuel Assembly Liftoff TELECON PARTICIPANTS:

(INCLUDE NAME AND Shih-Lieng Vu.USNRC)

ORGANIZATION OF E ACH)

P. Kadambi (USNRC) i PAGE 2 OF 2 w r unuell nn (p s cc:

J. N. Bailey A. W. Harrison C. K. Chitkara A. Sanislo M. A. McBurnett J. S. Phelps D. Ashton (BEC)

P. G. Trudel (BEC)

J. K. Atwell (BEC)

W. Spezialetti (W)

B. Lorenz (W)

T. Roberson (Bethesda Licensing Office)

R. Sweeney (Bethesda Licensing Office)

STP RMS (2) i i

1, mi s m em, STP-103 (6 79) l

-