ML20207F406

From kanterella
Jump to navigation Jump to search
Amend 7 to License SNM-463 for Dot,Coast Guard Academy, Amending License in Entirety
ML20207F406
Person / Time
Site: 07000510
(SNM-0463-A-07, SNM-463-A-7)
Issue date: 12/12/1986
From: Jennifer Davis
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20207F410 List:
References
NUDOCS 8701060008
Download: ML20207F406 (2)


Text

&

-____________________________g l

NRC FcnWM4

-n m

l l (5 84)

?.S. NUCLEAR REGULATORY COMMISSION NES l MATERIALS LICENSE Amendment No. 07 Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93 -438), and Title 10, Code of Federal Regulations, Chapter I, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct,

~1 source, and special nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below;to I

deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the apphcable Part(s). This l

U f; license shall be deemed to contain the conditions specified in Section 183 of the Ato subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any l g conditions specified below.

{

[h l

Licensee In accordance with application dated i

i ovember 3, 1986 g

1-cense number q

Department of Transportation 3.

SNM-463 is amended in i

i U.S. Coast Guard Academy its entirety to read as follows:

i Department of Science

~

O*-

2-e New London, Connecticut 06320

4. Expiration date May 31, 1990 i

eren$ No.

70-00510

6. Byproduct, source, and/or
7. Chemical and/or physical

( 8. Maximum amount that licensee I

special nuclear material form

-7 may possess at any one time i

j

,ander this license i

I A. Plutonium 239 A. Encapsulated A. 80 grams i,

I as Pu-Be I

neutron sources I

i 9.

Authorized use i'

1 A.

For use in teaching and training of students.

i i

i l

CONDITIONS

!W

10. Licensed material shall be used only at U.S. Coast Guard Academy, New London, j'

Connecticut.

11. Licensed material shall be used by, or under the supervision of, l

1 Edward L. Wilds, Jr., or Robert J. Fuller.

f

12. Licensed material shall not be used in or on human beings.
13. A(1) Any sealed source or detector cell specified in Item 7.A shall be tested for leakage and/or contamination at intervals not to exceed 6 months. Any source i

or detector cell received from another person which is not accompanied by a l

certificate indicating that a test was performed within 6 months before the l

transfer shall not be put into use until tested.

{

b (2) Notwithstanding the periodic leak test required by this condition, any licensed sealed source or detector cell is exempt from such leak tests l

t when the source or detector cell contains 100 microcuries or less of beta I

and/or gamma emitting material or 10 microcuries or less of alpha emitting j

material.

l' B.

Any sealed source or detector cell in storage and not being used need l

g!

not be tested. When the source or detector cell is removed from storage I

i g

for use or transfer to another person, it shall be tested before use or

" g g {J ],] {t g "

transfer.

b H81T?898"'2"2" SNM-0463 PDR

mm,q


.__m____z.

FosftO74A U.S. NUC L AR REGULATORY COMMISSION 2

2 M

PAGE er

,,ces License numbety

(

SNM-463 MATERIALS LICENSE oocket er Reference number SUPPLEMENTARY SHEET 070-00510 Amendment No. 07 (13. continued)

CONDITIONS C.

The test shall be capable of detecting the presence of 0.005 microcurie of radioactive material on the test sample.

If the test reveals the presence of 0.005 microcurie or more of removable contamination, the source or detector cell shall be removed from service and decontaminated, repaired, or disposed of in accordance with Comission regulations. A report shall be filed within 5 days of the date the leak test result is p

known with the U.S. Nuclear Regulatory Commission, Region I, ATTN:

Chief, y

Nuclear Materials Safety and Safeguards Branch, 631 Park Avenue, King of

[

Prussia, Pennsylvania 19406. The report shall specify the source involved, E

the test results, and corrective action taken. Records of leak test E

results shall be kept in units of microcuries and shall be maintained for E

inspection by the Comission.

Records may be disposed of following l

Comission inspection.

l D.

Tests for leakage and/or contamination shall be performed by the licensee or by other persons specifically licensed by the Comission or an Agree-l ment State to perform such services.

14. Sealed sources or detector cells containing licensed material shall not be f

opened or sources removed from detector cells by the licensee.

15. Except as specifically provided otherwise in this license, the licensee shall conduct its program in accordance with the statements, representations, and procedures contained in the documents including any enclosures, listed below.

The Nuclear Regulatory Comission's regulations shall govern unless the state-g ments, representations and procedures in the licensee's application and corre-pj spondence are more restrictive than the regulations.

F kt A.

Letter dated February 20, 1980 E!

i f

B.

Letter dated January 14, 1985 C.

Letter dated November 3, 1986 pl 1

For the U.S. Nuclear Regulatory Commission 12 DEC 1986 oco.m.vm:

Date By Nuclear Materials Safety and Safeguards Branch, Region I

)

King of Prussia, Pennsylvania 19406 i

E M - - E'- T'W E E E T E % E -

WTO YEIT W W T. EM MNY EYYTE 5

..-