l s

e 1

Public Service Electric and Gas Company St0ven E. Mittenberger Public Service Electric and Gas Company. P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-4199 AUG 0 3 1988 -

vee pres oent and cmet Necar omce, NLR-N88117 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 1

Gentlemen:

PROCESS CONTROL PROGRAM FACILITY OPERATING LICENSE NPF-57 HOPE CREEK GENERATING STATION DOCKET NO. 50-354 Public Service Electric and Gas Company hereby requests NRC approval of our use of the Wastechem Corporation Volume Reduction and Solidification (VRS) system installed at our Hope Creek Generating Station for processing Class B and C Ecodex and Bead Resin waste.

In support of this request, we have attached the test results for solidified wastes representative of those specific Class B and C waste forms produced by our system.

In a letter dated October 4, 1985 (W. Butler, NRC to R.L.

Mittl, PSE&G) the NRC approved our Process Control Plan (PCP) for Class A waste processing and in an April 9, 1987. letter (E. Adensam, NRC to C.A. McNeill, PSE&G), permitted interim use of our PCP, Revision 1, submitted November 25, 1986,-which included Class A, B,

and C waste processing.

The Class B and C processing was to be performed by our temporarary radwaste vendor, Chem Nuclear Services, until the completion of NRC staff review of WasteChem Topical Report VRS-002, "10 CFR 61 Waste Form Conformance Program for Solidified Process Waste Products Produced by a WasteChem Corporation Volume Reduction and Solidification (VRS) System".

This Topical Report supports the permanently installed Hope Creek Generating Station VRS radwaste processing system.

In a letter (M. Tokar, NRC to W.J.

Klein, Wastechem Corp.) dated January 22, 1988, the NRC accepted the above referenced Topical Report subject to the conditions provided on page 16 of the NRC Technical Evaluation Report (TER).

As provided in our FSAR descriptions and in Attachment 1, the results of our Waste Form Conformance/ Equivalence Testing, we have demonstrated that our system satisfies the TER specified conditions and surpasses all current NRC acceptance criteria.

$O 8808110024 880803 V

Jl 1

1 PDR ADOCK'05000354 I

P PDC

Document Control Desk 2

AUG 03 E88 Since Ecodex and Bead Resin waste forms comprise roughly 95% of our waste at this time, your approval of our use of the Waste-Chem VRS process for these wastes will afford an appreciable saving to PSE&G with regard to discontinuance of temporary vendor processing.

We will continue with our efforts to qualify our system to address the remaining waste forms.

We will be pleased to discuss'any questions you may have regarding this transmittal.

Sincerely, J.

Steven E. Milte berger, Vice President and Chief Nuclear Officer Attachment C

Mr. G.

W.

Rivenbark USNRC Licensing Project Manager Mr.

D.

K.

Allsopp USNRC Resident Inspector Mr.

D.

M.

Scott, Director Bureau of Nuclear Engineering Department of Environmental Protection 380 Scotch Road Trenton, NJ 08628 t

NLR-N88117 i

,9 Page 1 of 8 ATTACHMENT Waste Form Conformance / Equivalence Testine I.

Bead Resin A.

Process Conditions Equivalence Test:

Maximum Evaporative Rate Feed Mode:

Slurry Feed. 12 weight % Dry Solids Specific Gravity:

1 02 Waste Feed:

0.54 spm Asphalt Feed:

0 10 spm Extruder / Evaporator RPM:

250 Waste Loading:

40 Ueight percent Dry Solids Temperature Profile:

Barrel Number:

2 3

4 5

6 2

8 Temp. ( *F):

200 246 236 337 311 331 239 E/E Evaporative Rate:

29 gal /hr.

B.

Cnmpressive Strength Hope Creek Compress. St rengt h(1)

NRC Acceptance (l bs. / i n. 2)

Criteria (1bs./in. 4 Identif. No.

880318 - 01 95 60 880318 - 02 125 60 C.

Post - 1,mersion (90 Day) Compressive Strensth Cl)

NRC Acceptance I

Hope Creek Compress. Strength Identif. No.

(165

/ in. 2)

Criteria (16s./ in. 2 )

8803;8 - 03 150 60 8803:8 - 04 145 60 (1) Performed at the NUS Laboratory in accordarece with ASTM Test Method 01074 except that the cross head speed was 0 225 in./ min.

versus 0 2 in./ min. (Lab. Analysis Report Attached)

NLR-N88117 Page 2 of 8 ATTACHMENT Uaste Form Conformance / Equivalence Testine II.

Bead Rrsin A.

Proesss Conditions Equivalence Test:

Minimum Temperature Profile Feed Mode:

Slurry Feed. 12 weight '4 Dry Solids Specific Gravity:

1 02 f'ast e F eed:

0.44 spm Asphalt Feed:

0.09 spm Extrudee / Evaporator Ron:

250 Waste Loading:

40 veight percent Ory Solids Temperature Profile:

Barrel Number:

2 3

/

5 6

2 1

Temp. (

F):

200 229 223 278 270 288 180 E/E Evaporative Rate:

2?.5 sal /hr B.

Compressive Strength r

Compress. Strength (1)

NRC Acceptance Hope Creek (1 bs. /i n. 2)

Criteria (1bs./in.2 3 Ident:f. No.

880318 - 05 103 60 880318 - 06 131 60 C.

Post - Immersion (90 Jav) Compressive Strenoth Compress. Strength (1)

NRC Acceptance Hope Creek Identif. No.

11F-

/ in.2)

Criteria (1bs./ in. 2 3, 38 8 - s7 137 60 8 ' ;,.,. -

08 136 60 (l'

NUS Laboratory in accordance with ASTM Tet

p t that the.coss heac speed was 0 225 in.cmin.

i r

v

  • in.

(Lab. Analysis Report Attached)

.. ~

NLR-N88117 Page 3 of 8 I

ATTACHMENT Waste Form Conformance / Equivalence Testine 111 Ecodex Slurry A.

Process Conditions Equivalence Test:

Maximum Evaporative Rate Feed Mode:

Slurry Feed, 12 weight % Ory Solids Specific Gravity:

1 02 Uaste Feed:

0.48 spm Asphalt Feed:

0.18 spm Extruder / Evaporator RPM:

250 Waste Loading:

25 weight perce.it dry Solids Temperature Pref 11e:

Barrel Number:

2 3

4 5

6 2

6

  • F):

211 254 234 334 309 342 144 Temp.

E/E Evaporator Rate:

26 gal /hr S.

Compressive Strength Hope Creek Comoress. Strengt.d1)

NRC Accecta ce Iggnj

.Nc.

(lbs./in.2)

Criteria (165

n.2) 380225 - 01 248 60 380225 - 02 221 60 C.

Post - Immersion (90 Day) Compressive Strenoth Hope Creek Comp r e s s. S t r e n g t h('D NRC Acceptance Idantif. No.

(lbs. / in. 2 )

Criteria (Ibs.< :n,23 c.5225 - 03 126 60 880225 04 129 60 (1) Pericrmed at tre NUS Laocratory in accordance uith ASTM Test

~

Hethod 01074 except that the cross head speed was 0.225 in./ min.

versus 0.2 in./ min. (Lat. Analysis Report Attached) i

\\

NLR-N88117

~

Page 4 of 8 ATTACHN(MI Waste Form Conformance / Equivalence Testine IV.

Ecodex Slurry A.

Process Conditions Equivalence Test:

Minimum Temperature Profile Feed Mode:

Slurry Feed. 12 weight */. Dry Solids

~

Specific Gravity:

1 02 Uaste Feed:

0.44 spm Asphalt Feed:

0 16 spm Extruder / Evaporator rom:

250 Uaste Loading:

25 veight percent Dry Solids Temperature Profile:

Barrel Number:

2 3

4 5

6

?

3 Temp. ( *F):

212 236 224 310 280 300 220 E/E Evaporator Rate:

23 5 gal /hr B.

Compressive Strength Hope Creek Compress. Strength (1)

NRC Acceptance Identif. No.

(I bs. /i n.2 )

Criteria (Ibs./in. 23 880225 - 05 254 60 880225 - 06 265 60

c..

Post - Immersion (90 Day) Compressive Strenath Hope Creek Compress. Strength (1)

NRC Acceptance Identif. No.

(ibs. / in. 2)

Criteria (16s./ in. 2 3 -

880225 - 07 132 60 880225

.08 145 60 (1) Ft-formed at the NUS 1.aboratory in acc;rdar:e with ASTM Test 1

Metnod 01074 except that the cross hea; speed was 0 225 in./m:n.

versus 0.2 in./ min. (Lab. Anal ysis Report At t ached) 4 e

REteli TO:

Ltboratory Services Group Park West Tc 5350 Campbells Run Road Cliff Mine Road i

Pittsburgh, PA 15205 P% burgh, PA 15275 412 766-1060

~

MW NLR-N80117

~

Page 5 of 8 l

LAD ANALYSIS RE.F'Of!T CLIDIT MEl liASTEDU CORP.

IRIS C1.IENT MO: 282832 J

A88tESS (BE KM.!SA liAY PARAWS NJ 07652 N N01 06945700 REPORT MTE: 07/07/88 IdMK MBER WI 5583 ATTDITIM 18t. NYRON KACZMRSKY MTE RENIO: 03/29/88 SAlrLE IBOITIFICATIllt ISE SAfrLE NO RESIA.TS LBilTS 880319 4 3 03/18 90 MY 18032244 S741 konfined Coestession 150 880318-M 03/18 90 M Y 18032245 5741 k ontined Coeiression 145 880318 4 7 03/18 90 M Y 18032244 S741 k onfined Coe ression 137 88031808 03/18 90 MY 1803224/

S741 kontined Corression 134 O

l l

C0180TS Reviewed and # Proved by Joanne C. Sin nic j

c :-

.a

?

REMIT 70:

Laboratcny Services Group Park West Two N'

5350 Campbells Run Road Cliff Mino Road Pittsburgh, PA 15205 Pittsburgh, PA 15275 412-786-t 000 MM

~

NLR-N88117

~,

Page 6 of 8 LAD ANALYSIS REPORT Q.!DIT N W : MBTEDO CORP.

M CLIDIT Mt 282802 ANRESSI M IW.IM Mi PAR M B KJ 07432 VOIBOR 2 REPORT MTE 06/29/08 140RK M Dt M I 5583 ATTDITIW W. NUtm KAC2M RSKY MTE RECEIBI 03/24/88 SWLE IIDITIFICAi!M M SNLE 2 RE9LA.TS lm!TS 900225-43 18031965

$741 Unconfleed coerression 124 psi 90022544 19031966 S741 therfined Coe*ression 127 psi 800225-47 19031967 5741 UnconfinedCoearession 132 psi 800225-08 19031968 S741 Unconfleed Compression 145 psi CQ9it.Wi$i i

Reviewed ned Approved but Jeanne C. Siennic

1 ASINT TC:

L40eratory Seryges Group Part Wut Two 5350 Camcws Aun Koad Chtf %ce Road i

I Pittsburgn, P A 15205 p itsburgn. P A 15275 4'2 758 'C80 M

NLR-N88117 i

Page 7 of 8 1

1. AD AN Al. ('3IS REf'OR T 1

AlS t'LIEie g01 282801 r

CLIENT 4(dE:

leSTECHOICORP.

400RESSt ONE OLISA Mr PARAMUS

4) 07652 VE40a4 @

06945700 i!PCR' DATE: 04/01/88 m OeXk @

55830 3 ATE RECEI O :

03/24/08 ATTDifl0W MR. Mit04 GC2MAmf 3 AMPLE IDENT!rICATION

  • JS SAMPLE W RE#.TS 04115 18031961 880225 01 248 S741 Unconf;ned Coe*ression 580225-02 1E431962 22 1 S741 ijnconf;ied Oceeress on

'80225-05 18031963 254 S741 Unconfined Co w ression 18031964 880225-04 265 S741 Unconfined Cwression f

l COMENTS Reviewd a'ni Aproved W! JCS

s, :

RE* lT TO:

l Labocatory Services Grov)

Fart West Two 5350 Campoetis Run Road Chtf %ee Road Pittseurgh, PA '5205 P ttsourgh. PA '!2'5 y

412 188 1060 l

l YMW NLR-N88117 Page 8 of 8

{

l

' A8 ANAL (SIS REPORT I

Wi 't.!ENT %:

.T801 CLIENT NME: MSTECO CatP.

ADDRES$t OIE KAl.!SA ef PARMtJS 4J 37652 VE WOR N0:

-)6745700 REPORT DATE: 04/11/88 WORK ORDER 20:

55830 DATE RECEIVD :

03/:9/?8 4TTENT10W: let. MYkON KACIMAGI W S SAMPLE NO RESais U41 $

SMFti IXNilFICATION 880318 4 1 03/18 24 W 19032240 95

$741 Unconfine5 0 w ression 880318 4 2 03/18 24 HOUR 18032241 125 l

S741 Unconfined C w ression t

880318-05 33/16 24 6 18032242 103 3741 Unconfined C w ression 880318-06 03/18 24 HOUR 16032243

$741 Unconfiied C w ression 131 I

1 l

l l

l l

COM E TS:

l Rniewd and keroved by: JCS I

4

-_