e e. 1 SEABROOK STATION Enginssring Of fics Y(.

.- I J

ruime s.Me. or New Hampe*.

NEW HAMPSHIRE YANKEE DIVISION July 16, 1986 SBN-1159 T.F.

B7.1.2 United States Nuclear Regulatory Commission Washington, DC 20555 Attention:

Mr. Vincent S. Noonan, Project Director PWR Project Directorate No. 5

References:

(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) PSNH Letter (EBN-1111), dated June 13, 1986,

" Response to Section 3.10 of SSER 4, Seismic and Dynamic Quali fication of Saf'ety-Related Mechanical and Electrical Equipment", J. DeVincentis to V. S.

Noonan Subj ect :

Completion of Seismic Qualification and Pump and Valve 0perability Programs

Dear Sir:

A clarification has been requested concerning a' response provided in Reference (b). The question and response for which a clarification wAs requested is:

~

1.

SER Section 3.'10.2.3:

What is the atatus of the generic program for cabinet spacing?

Response: The program ' addressing cabinet spacing has been completed and modifications as required have been imple-me nt ed.

s I

s

\\

8607180175 86071!

N PDR ADOCK 05000443 E

PDR-Seabrook Station, Construction Field Office. P.O. Box 700 Seatxook, NH O3874

.4 United States Nuclear Regulatory Commission SBN-Attention:

Mr. Vincent S. Noonan Page 2 As further clarification to the above response we of fer the following. The program addressing seismic interaction of cabinets required a walkdown to check each cabinet'(i.e., review cabinet spacing). This review or check entailed a comparison of actual measurements to the applicable spacing criteria which was estab-lished based on precalculated deflections.

In those situations where a discrepancy was identified, the cabinets were structurally connected. When connected, an analysis was done to check the natural frequency and strength of the connection and the overall assembly.

It should be noted that in one case (VB-CB-299, SQRT item BOP-11) the solution was to move the cabinet which has been completed. All cabinet interaction problems have been identified and the required modifications and analysis are complete.

We trust this information is acceptable and request the status of these items be reflected in the next supplement to Seabrook's SER.

Very truly yo rs, John DeVincentis Director of Engineering cca Atomic Safety and Licensing Board Service List o

O Dicus Curr n, Esquira Pater J. Mathsws, Mayor Harmon & Weico City Hall 2001 S. Street, N.W.

Newburyport, MA 01950 Suite 430 Washington, D.C.

20009 Judith H. Mizaer Silvergate, Gertner, Baker, Sherwin E. Turk, Esq.

Fine, Good & Mizner Office of the Executive Legal Director 88 Broad Street U.S. Nuclear Regulatory Commission Boston, MA 02110 Tenth Floor Washington, DC 20555 Calvin A. Canney City Manager Robert A. Backus, Esquire City Hall 116 Lowell Street 126 Daniel Street P.O. Box 516 Portsmouth, NH 03801 Manchester, NH 03105 Stephen E. Merrill, Esquire Philip Ahrens, Esquire Attorney General Assistant Attorney General George Dana Bisbee, Esquire Department of The Attorney General Assistant Attorney General Statehouse Station #6 Office of the Attorney General Augusta, ME 04333 25 Capitol Street Concord, NH 03301-6397 Mrs. Sandra Gavuti-Chairman, Board of Selectmen Mr. J. P. Nadeau RFD 1 - Box 1154 Selectmen'a Office Kenosington, NH 03827 10 Central Road Rye, NH 03870 Carol S. Sneider, Esquire Assistant Attorney General Mr. Angie Machiros Department of the Attorney General Chairman of the Board of Selectmen One Ashburton Place,19th Floor Town of Newbury Boston, MA 02108 Newbury, MA 01950 Senator Gordon J. Humphrey Mr. William S. Lord U.S. Senate Board of Selectmen Washington, DC 20510 Town Hall - Friend Street (ATTN: Tom Burack)

Amesbury, MA 01913 Richard A. Hampe, Eng.

Senator Gordon J. Humphrey Hampe and McNicholas 1 Pillsbury Street 35 Pleasant Street Concord, NH 03301 Concord, NH 03301 (ATTH: Herb Boynton)

Thomas F. Powers, III H. Joseph Flynn, Esquire Town Manager Office of General Counsel Town of Exeter Federal Emergency Management Agency 10 Front Street 500 C Street, SW Exeter, NH 03833 Washington, DC 20472 Brentwood Board of Selectmen Paul McEachern, Esquire RFD Dalton Road Matthew T. Brock, Esquire Brentwood, NH 03833 Shaines & McEachern 25 Maplewood Avenue Gary W. Holmes, Esq.

P.O. Box 360 Holmes & Ells Portsmouth, NH 03801 47 Winnacunnet Road Hampton, NH 03842 Robert Carrigg Town Office Mr. Ed Thomas Atlantic Avenue FEMA Region I North Hampton, NH 03862 442 John W. McCormack PO & Courthouse Boston, MA 02109

._.