Text

[

l a na%,i l'

UNITED STATES p

t,.

g j

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20066 4001

\\...../

DETROIT EDISON COMPANY DOCKET NO. 50-341 FERMI 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.133 License No. NPF-43 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by the Detroit Edison Company (the licensee) dated March 23,1999, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

l l

l 9905280018 990525 PDR ADOCK 05000341 P

PDR l

F:-

]

1 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and paragraph 2.C.(2) of Facility Operating License No. NPF-43 is hereby amended to read as follows:

i l'

Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through j

Amendment No. 133, and the Environmental Protection Plan contained in j

i Appendix B, are hereby incorporated in the license. DECO shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

1 3.

This license amendment is effective as of its date of issuance and shall be implemented within 90 days.

FOR THE NUCLEAR REGULATORY COMMISSION i

a Geor F. Dick, Jr., Acting Chief, Section 1 I

Project Directorate 111 Division of Licensing Project Management Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: May 25,1999

ATTACHMENT TO LICENSE AMENDMENT NO. 133 FACILITY OPERATING LICENSE NO. NPF-43 DOCKET NO. 50-341 Replace the following pages of the Appendix "A" Technical Specifications with the attached

)

pages. The revised pages are identified by amendment number and contain vertical lines indicating the area of change.

REMOVE INSERT 3/44-1 3/4 4-1*

3/4 4-2 3/4 4-2 t

  • Overleaf page provided to maintain document completeness. No changes contained on this page.

1

l l.-

1 l(;-

3/4 4.4 REACTOR COOLANT SYSTEM 3/4 4.4.1 RECIRCULATION SYSTEM RECIRCULATION LOOPS LIMITING CONDITION FOR OPERATION 3.4.1.1 Two reactor coolant system recirculation loops shall be in operation.

APPLICABILITY: OPERATIONAL CONDITIONS 1 and 2*.

ACTION:

a.

With one reactor coolant system recirculation loop not in operation:

1.

Within 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />s:

a)

Place the individual recirculation pump flow controller for the operating recirculation pump in the Manual mode.

b)

Reduce THERMAL POWER to less than or equal to 67.2% of RATED THERMAL POWER.

c)

Limit the speed of the operating recirculation pump to less than or equal to 75% of rated pump speed.

d) increase the MINIMUM CRITICAL POWER RATIO (MCPR) Safety Limit to the value for single loop operation required by Specification 2.1.2.

e)

Change the Average Power Range Monitor (APRM) Simulated Thermal Power-Upscale Flow Biased Scram and Rod Block Trip Setpoints and Allowable Values to those applicable for single recirculation loop l

operation per Specifications 2.2.1 and 3.3.6.

f)

Perform Surveillance Requirement 4.4.1.1.4 if THERMAL POWER is less than or equal to 30% of RATED THERMAL POWER or the recirculation loop flow in the operating loop is less than or equal to 50% of rated loop flow.

2.

Otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, b.

With no reactor coolant system recirculation loop in operation while in OPERATIONAL CONDITION 1, immediately place the Reactor Mode Switch in the SHUTDOWN position.

c.

With no factor coolant system recirculation loops in operation, while in OPERATIONAL CONDITION 2, initiate measures to place the unit in at least HOT SHUTDOWN within l

the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

  • See Special Test Exception 3.10.4.

FERMI-UNIT 2 3/4 4.1 Amendment No. 53, 64, 69,88, M, A09,122 I

REACTOR COOLANT SYSTEM SURVEILLANCE RE0VIREMENTS 4.4.1.1.1 Each pump discharge valve shall be demonstrated OPERABLE by cycling each valve through at least one complete cycle of full travel at least once per 18 months.

4.4.1.1.2 DELETED

4. 4.1.' I. 3 With one reactor coolant system recirculation loop not in operation, at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> verify that:

a.

THERMAL POWER is less than or equal to 67.2% of RATED THERMAL POWER, and b.

The individual recirculation pump flow controller for the operating recirculation pump is in the Manual mode, and c.

The speed of the operating recirculation pump is less than or equal to 75% of rated pump speed.

4.4.1.1.4 With one reactor coolant system loop not in operation with THERMAL POWER less than or equal to 30% of RATED THERMAL POWER or with recirculation loop flow in the operating loop less than or equal to 50% of rated loop flow, verify the following differential temperature requirements are met within no more than 15 minutes prior to either THERMAL POWER increase or recirculation flow increase:

a.

Less than or equal to 145'F between reactor vessel steam space coolant and bottom head drain line coolant, and b.

Less than or equal to 50*F between the reactor coolant within the loop not in operation and the coolant in the reactor pressure vessel **, and c.

Less than or equal to 50*F between the reactor coolant within the loop not in operation and the operating loop.**

i

  • Not used.
    • Requirement does not apply when the recirculation loop not in operation is isolated from the reactor pressure vessel.

FERMI - UNIT 2 3/4 4-2 Amendment No. JJ, ES, E7, JJS,133