ML20207A788
| ML20207A788 | |
| Person / Time | |
|---|---|
| Issue date: | 11/05/1986 |
| From: | Crutchfield D, Miraglia F Office of Nuclear Reactor Regulation |
| To: | Wells R C-E OPERATING PLANTS OWNERS GROUP |
| Shared Package | |
| ML20207A791 | List: |
| References | |
| NUDOCS 8611110293 | |
| Download: ML20207A788 (4) | |
Text
.
m.:
UNITED STATES y'
p, NUCLEAR REGULATORY COMMISSION
'j WASHINGTON D. C. 20555 y
i
\\...../
November 5, 1986 Mr. Rik W. Wells, Chairman Combustion Engineering Owners Group i
P.O. Box 270 Hartford, CT 06141-0270
's'
Dear Mr. Wells:
Subject:
SUPPLEMENT 3 TO SAFETY EVALUATION FOR CEN-152, " COMBUSTION ENGINEERING EMERGENCY PROCEDURE GUIDELINES"
" ]@
References:
1.
Letter, D.G. Eisenhut (NRC) to R.W. Wells (CE0G), " Safety Evaluation of Emergency Procedure Guidelines," dated July 29, 1983 n
2.
Letter, J.A. Zwolinski (NRC) to R.W. Wells (CE0G),
" Supplement 1 to Safety Evaluation for CEN-152, Combustion q
~ Engineering Emergency Procedure Guidelines," dated il April 16, 1985
'I b
3.
Letter, J.A. Zwolinski (NRC) to R.W. Wells (CE0G),
" Supplement 2 to Safety Evaluation for LEN-152, Combustion y
Engineering Emergency Procedure Guidelines," dated
't December 2, 1985 g
44 Enclosed is Supplement 3 to the Safety Evaluation Report (SER) for CEN-152,
" Combustion Engineering Emergency Procedure Guidelines." Our evaluation is i
based on the review of Submittal 2 of Revision 03 to CEN-152, which was trans-mitted by the Combustion Engineering Owners Group (CE0G) in a letter dated J
August 6, 1986. The staff has previously issued other evaluations which are y
contained in References 1, 2, and 3.
Based on our review of the CE0G submittal, we conclude that Submittal 2 of Revision 03 to CEN-152 is acceptable for implementation, and will provide i
improved guidance of emergency operating procedure development.
2
,p 9Y f, c
. 1111 _. 11.
PDR TOPRP EMVC-E C
Mr. Rik W. Wells, Chairman It'is our understanding that the next submittal of CEN-152 is scheduled for January 1987, and will address most of the remaining open items identified in our_ July 29, 1983 SER. The staff i; available to work with the CE0G to resolve the remaining items.
Frank J. Miraglia, Director Division of PWR Licensing-B Office of Nuclear Reactor Regulation
Enclosure:
Supplement 3 to SER cc:
T. Szymanski R. Eaton R. Keller, RI J. Munro, RII T. Burdick, RIII R. Cooley, RIV J. Elin, RV CE0G Service List (see next page)
Distribution:
Central Files NRC PDR LPDR
-T. Greene J. Calvo C. Thomas D. Crutchfield F. Miraglia F0B Rdg. Files plI]dl0 46% blQL, F08:PWR-B*
PEICS:PWR-R
- PWR-&-
F08:PWR-B*
A/ '" " 'S '
TAGreene:js J. Calvo as W. Regan D.
tchfield 10/29/86 1(/3/86 1A/4 /86 10/29/86 1$/[/86 D:PWR-B F. Miraglia 14/
/86 0FFICIAL RECORD COPY
s u -
Mr. Rik W. Wells, Chairman November 5, 1986 It is our understanding that the next submittal of CEN-152 is scheduled for January 1987, and will address most of the remaining open items identified in our July 29, 1983 SER. The staff is available to work with the CE0G to resolve the remaining items.
Cristenteign:aty 9M12L Cratchf1414 Dennis M. Crutchfield, Assistant Director Division of PWR Licensing-B Office of Nuclear Reactor Regulation
Enclosure:
Supplement 3 to SER cc:
T. Szymanski R. Eaton R. Keller, RI-J. Munro, RII T. Burdick, RIII R. Cooley, RIV J. Elin, RV CE0G Service List (see next page)
Distribution:
- Central Files NRC PDR LPDR
'T. Greene J. Calvo C. Thomas D. Crutchfield F. Miraglia F0B Rdg. Files F0B:PWR-B*
PEICS:PWR-B*
RSB:PWR-B*
F08:PWR-B*
A t
TAGreene:js J. Calvo C. Thomas W. Regan D.
tchfield 10/29/86 11/03/86 11/04/86 10/29/86 11/
/86 77 0FFICIAL RECORD COPY s
--.,---r,
-r m
m~
- -L -
Mr.:Rik W. Wells, Chairman
-2 It is our understanding that the next submittal of CEN-152 is sch.e uled for January 1987, and will address most of the remaining open items / identified in our July 29, 1983 SER. The staff is available to work with'the CE0G to resolve the remaining items.
Frank J. Miraglia, Director Division of PWR Licensing-B 0ffice of Nuclea Reactor Regulation
Enclosures:
- 1. Supplement 3 to SER cc:
T. Szymanski R. Eaton R. Keller, RI J. Munro, Rll T. Burdick, RIII R. Cooley, RIV J. Elin, RV CE0G Service List (se nextpage)
Distribution:
Central Files NRC PDR LPDR T. Greene.
J. Calvo C. Thomas D. Crutchfiel F. Miraglia F0B Rdg.'F es TAGreene:j@s A/D:PWR-B F08:PWR-B PEICS:PWR-B RSB:PWR-B F'O J. Calvo C. Thomas W. Regan D. Crutchfield 10/2f} /86 10/
/86 10/
/86 10/) 9 /86 10/
/86 D:PWR-B
'F. Miraglia 10/
/86 0FFICIAL RECORD COPY