Addendum to Rev 8 to Section 5 to Vol 1 of Inservice Insp Plan
ML20206S557
Person / Time
Site: McGuire, Mcguire  
Issue date: 06/16/1986
From: Underwood G
DUKE POWER CO.
To:
Shared Package
ML20206S501 List: ... further results
References
1MCG-0040-ADD, 1MCG-40-ADD, NUDOCS 8607070381
Download: ML20206S557 (5)


Text

.

Form QA-513A 26085 (1-82)

Revision I Procedure QA-513 DUKE POWER COMPANY QUALITY ASSURANCE DEPARTMENT OPERATIONS DIVISION Seri al No. Iptt,.co 4e PSl/ISI PLAN ADDENDUM Unit 1k2.

Station w%e ISI Plan PSI Plan Current Plan Revision 6

Page n 'l A Section 5, h,\\

Detailed Description of Proposed Change: t%.h & 4htatec Cbnoc3 to Tutt.% ut 1%WtTT.en 7LKM F6R h%M4 EMM 2 IMMS-C.\\- 30 Fl 2.

Rd.Y k%C.nb mfd $

C 2-2b CS 70 c3.too C5 21

! I ' ', t "' '

m C5 Si

' : '.. c....

l jui-i i

i C5-32 CT 40 l

CT H l

Originated By (A%d Date 6\\%\\vh mm kob EST 0 ate Ab[4 Approved By tv Tltie 8607070381 860620 il PDR ADOCK 05000369 f)t O

PDR l

a PLAN ADDENDUM.1MCG-0040 5.0 Inservice Inspection Plan For ASME Class 2 Items The inservice inspection of ASME Class 2 items shall be performed in accordance with the requirements of Paragraph IWC-2500 of ASME Section XI.

Specific examination listings and schedules are described in Section 8 of this Plan.

5.1 Examination Categories and Requirments The examination categories to be used are those listed in Table IWC-2500 of ASME Section XI.

Specific examinations will be identified by an Item Number, composed of the Item Number assigned in Table IWC-2500 of Section XI, plus an additional number to uniquely identify that examination.

Class 2 items to be inspected include:

IWC-2500-1 Item Component to be Examined Comments C1.10 Shell Circumferential Welds C1.20 Head Circumferential Welds l

l C1.30 Tubesheet-to-Shell Weld None k

C2.10 Nozzles in Vessels <-

in.

Nominal Thickness a)

IC p0hm gt C2.20 Nozzles in Vessels >

in.

None 1

Nominal Thickness u

o C2.21 Nozzle-to-shell (or head) weld C2.22 Nozzle inside radius Nozzles >12" NPS section Pressure Vessels Attachments whose base material C3.10 Integrally Welded design thickness is 3/4" or Attachments greater Piping Attachments whose base material C3.40 Integrally Welded design thickness is 3/4" or Attachments greater Pumps C3.70 Integrally Welded None Attachments Valves C3.100 Integrally Welded None Attachments e

INSERVICE INSPECTION PLAN REV. 5 MCGU1RE NUCLEAR STATION PAGE 1 C/C550013

l PLAN ADDENDUM 1MCG-0040 IWC-2500-1 Item Component to be Examined Comments Pressure Vessels C4.10 Bolts and Studs Piping l

C4.20 Bolts and Studs None Pumps C4.30 Bolts and Studs None Valves C4.40 Bolts and Studs None Piping Welds <

in.

Nominal Walt Thickness C5.11 Circumferential weld C5.12 Longitudinal weld Piping Welds >

in.

Nominal Wall Thickness C5.21 Circumferential weld R

g)

C5.22 Longitudinal Weld None Pipe Branch Connections

~ ~~"J i

C5.31 Circumferential weld None I

~

C5.32 Longitudinal Weld None Pumps a

C6.10 Pump Casing Welds None i

Valves C6.20 Valve Body Welds None Pressure Vessels C7.10 Pressure Retaining Components C7.11 Pressure Retaining Components j

Piping C7.20 Pressure Retaining Components J

C7.21 Pressure Retaining Components Pumps C7.30 Pressure Retaining Components C7.31 Pressure Retaining Components j

l REV. 5 INSERVICE INSPECTION PLAN PAGE 2 MCGUIRE NUCLEAR STATION C/6550013

PLAN ADDENDUM IMCG-00 40 IWC-2500-1 Ites Component to be Examined Comments Valves C7.40 Pressure Retaining Components None

~

C7.41 Pressure Retaining Components None Component Supports F1.02 (a) Mechanical Attachments Supports of non-exempt Class 2 Including Bolting components (See par. 2.1)

(b) Welded Attachments (c) Component Displacement; Settings of Guides and Stops; Misalignment of Supports; Assembly of Support Items j

(d) Spring Type Supports l

Constant Load Type Sup-Supports of non-exempt Class 2 ports Shock Absorbers components (See par. 2;l)

Hydraulic and Mechanical Type Snubbers 5.2 Weld Selection for Inservice Inspection Welds shall be selected for inservice inspection in accordance with Article IWC-2000 of Section XI.

The selection criteria for each category of Table IWC-2500-1 will be applied.

Class 2 welds that exceed the stress criteria given in Table IWC-2500-1 are listed below.

5.2.1 Residual Heat Removal System (NO)

Unit 1 Weld Number Piping Isometric Flow Diagra IN069A-3 MCFI-1NO31 MC1561-1.0 f

[h L

~

5.2.2 Containment Air Release and Addition System Unit 1 i

Wcld Number Piping Isometric Flow Diagram IVQP17-1 MCFI-IVQ4 MC1585-1.0 VQ1F46 MCFI-IVQ4 Unit 2 f

VQ2FW8-19 MCFI-2VQ8 MC2585-1.0 VQ2FW8-20 MCFI-2VQ8 MC2585-1.0 REV. 5 INSERVICE INSPECTION PLAN MCGUIRE NUCLEAR STATION C/6 13

Form QA-513A Ilklb 26085 (1-82)

Revision 1 Procedure QA-513 DUKE POWER COMPANY QUALITY ASSURANCE DEPARTMENT l

OPERATIONS DIVISION Serial No.

Imcf. co39 PSI /ISI PLAN ADDENDUM Unit

/

Station m%w ISI Plan PSI Plan Current Plan Revision 8

Section (,Ag d s. A Ve ?_

Page t'

"cul % h' Detailed Description of Proposed Change:

Lh RoswitE BG 6\\o 06\\

'AAh onbus 4 anh 7 a

y.'

7-e;;:7-n a t-

m.:

Date Ght kb4

\\\\d_%_wb Originated By

.m

'\\

\\

Approved By h/

m Title bridget-Is.; Date

/,

-