ML20206Q106
| ML20206Q106 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 04/15/1987 |
| From: | Wilson R GENERAL PUBLIC UTILITIES CORP. |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| Shared Package | |
| ML20206Q111 | List: |
| References | |
| 5000-87-1224, NUDOCS 8704210342 | |
| Download: ML20206Q106 (2) | |
Text
'
4 GPU Nuclear NggIgf 100 Interpace Parkway Parsippany, New Jersey 07054 201 263-6500 TELEX 136-482 Writer's Direct Dial Number:
April 15, 1987 5000-87-1224 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C.
20555 Gentlemen:
Subject:
Oyster Creek Nuclear Generating Station (0CNGS)
Docket No. 50-219 Reload Topical Report In accordance with our letter of November 25, 1985, please find attached Topical Report 033 entitled; " Methods for the Generation of Core Kinetics Data for RETRAN-02" and Topical Report 040 entitled; " Steady-State and Quasi-Steady-State Methods used in the Analysis of Accident and Transients". The attached reports are the third and fourth of a series of four topical reports being forwarded to the NRC for review and approval for use in OCNGS reload licensing.
As discussed in our previous letters, it is our intent to conduct in-house analyses for any core related changes to the OCNGS Technical Specifications during Cycle 11 operation and perform the full reload core safety analysis in-house for the Cycle 12 core.
In order to support these goals, it is requested that the NRC complete their review of the above topical reports by September 1987.
If you have any questions, please contact M. W. Laggart at (201)263-6205.
In accordance with the requirements of 10CFR170, a check for $300 is attached.
Si cer ly
\\
h
. F. Wislson Vice President i
Technical Functions RFW/JDL/pa(1255g)
Attachments cc's on next page j
f)ghh h p*[* a6 8704210342 870415 4
PDH ADOCK 05000219
\\
fk p
PDR GPU Nuclear is a part of the General Public Utilities System
Dr. Thomas E. Murley, Administrator cc:
Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA.
19406 NRC Resident Inspector Oyster Creek Nuclear Generating Station Forked River, N.J.
08731 Mr. Jack N. Conohew, Jr.
U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Phillips Building, Mail Stop 314 Bethesda, Maryland 20014 0
G. ;'i':llJ a2,_ m 2,,2 a g u,m.
1,
.q;..,,_,y.m.
u 0
- l G
t i
'P(ia v
dj i
i 0 I
1 1
1 l
N Service l,,l.
5 N
Nuclear
]
't
,i
.w I
cENERAL PUBLC UTWES l
l I
i
!L:
I,
- - - - - - _ _.. ~ ~. _ _ - _ _ _ _ _, _,, _,, _ _, _ _
.,,,,