LIMITING CONDITIONS FOR OPERATION 3.9.12.2 The Auxiliary Building Air Cleanup Exhaust System shall be OPERABLE with exhaust ventilation flow through the HEPA filters during system operation.

The Auxiliary Building Air Cleanup Exhaust System is OPERABLE when two of the four system air cleanup exhaust fans are OPERABLE.

APPLICABILITY: RECOVERY MODE ACTION:

a.

With the Auxiliary Building Air Cleanup Exhaust System inoperable due to flow requirements, return the flow to within acceptable limits within four (4) hours or; b.

With the Aux 111ary Building Air Cleanup Exhaust System inoperable (other than as allowed in Paragraph 3.9.12.2.a above), suspend all operations involving movement of liquid and gaseous radioactive wastes in the Auxiliary Building (other than sampling evolutions required by the Technical Specifications or RECOVERY OPERATIONS PLAN) until the system is restored to OPERABLE status.

ACCIDENT GENERATED WATER 3.9.13 ACCIDENT GENERATED WATER shall be discharged in accordance with NRC-approved procedures.

APPLICABILITY: Recovery Mode ACTION:

None except as provided in Specification 3.0.3.

I THREE MILE ISLAND - UNIT 2 3.9-3

--