Requests Addl Info on SER Confirmatory Item 10, Final Pipewhip & Jet Impingement Evaluation for High-Energy Piping. Final Stress Results for Class I Lines in FSAR Table 3.6.2-1 Requested within 45 Days
ML20206H407
Person / Time
Site: Vogtle  
Issue date: 06/20/1986
From: Mark Miller
Office of Nuclear Reactor Regulation
To: Conway R
GEORGIA POWER CO.
References
NUDOCS 8606260064
Download: ML20206H407 (3)


Text

.--

Docket Nos.: 50-424 50-425 20 M M Mr. Richard Conway Vice President and Project General Manager Georgia Power Company Box 299A, Rt. 2 Waynesboro, GA 30830

Dear Mr. Conway:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION ON V0GTLE SER CONFIRMATORY ITEM 10 " FINAL PIPEWHIP AND JET IMPINGEMENT EVALUATION FOR HIGH-ENERGY PIPING" t

The staff has reviewed Vogtle FSAR Amendment 22 in which you have addressed confinnatory item 10. " Final pipewhip and jet impingement evaluation for high-energy piping." Section 3.6.2.5.1 of this FSAR amendment states that the final and complete analysis results for ASME Class 2, Class 3, and non-nuclear lines have been provided in FSAR Figure 3.6.1-1 and that the results for Class I lines will be provided upon their completion.

In order to complete its review, the staff requests that you provide the final stress results for Class 1 lines in the applicable portions of FSAR Table 3.6.2-1 within 45 days of the date of this letter in order to resolve this issue prior to Vogtle Unit I licensing.

If there are any questions regarding this request contact me at (301) 492-7357.

Sincerely, 6\\

Melanie A. Miller, Project Manager PWR Project Directorate #4 Division of PWR Licensing-A cc: See Next Page

~

DISTRIBUUO4 l

{-NRC_PDR )

1 Docket File -

local PDR PRC System i

NSIC PWRf4 Rdg 86062600 y $g80$S24 MM r

l ADO BJYoungblood Rdg

{DR PDR OELD ACRS(10) l JPartlow BGrimes EJordan JBrammer E DP R-A EB/

R GBagchi GBagchi RBal RBallard 06/ p /86 06/ /r /86 d

M,*

PW L

WR-A PWR$

PWR-A PWRF4/DPWR-A EB/0PWR-A//g MM mac PtDdd n blood JBransner41V 06/qBJYounf86 06

, 86 06// /86 06//t /86

  • (

i o

UNITED STATES g

8 NUCLEAR REGULATORY COMMISSION g

5 j

WASHINGTON, D C. 20555 k*...+/

2 0 JUN N J

Docket Nos.: 50-424 50-425 Mr. Richard Conway Vice President and Project General Manager Georgia Power Company Box 299A, Rt. 2 Waynesboro, GA 30830

Dear Mr. Conway:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION ON V0GTLE SER CONFIRMATORY ITEM

10. " FINAL PIPEWHIP AND JET IMPINGEMENT EVALUATION FOR HIGH-ENERGY PIPING" The staff has reviewed Vogtle FSAR Amendment 22 in which you have addressed confirmatory item 10. " Final pipewhip and jet impingement evaluation for high-energy piping." Section 3.6.2.5.1 of this FSAR amendment states that the final and complete analysis results for ASME Class 2. Class 3, and non-nuclear lines have been provided in FSAR Figure 3.6.1-1 and that the results for Class 1 lines will be provided upon their completion.

In order to complete its review, the staff requests that you provide the final stress results for Class 1 lines in the applicable portions of FSAR Table 3.6.2-1 within 45 days of the date of this letter in order to resolve this issue prior to Vogtle Unit 1 Itcensing.

If there are any questions regarding this request contact me at (301) 492-7357.

Sincerely, L

lanie A. Miller, Project Manager PWR Project Directorate #4 Division of PWR Licensing-A cc: See Next Page 1

Mr. R. E. Conway Georgia Power Company Vogtle Electric Generating Plant cc:

Mr. L. T. Gucwa Resident Inspector Chief Nuclear Engineer Nuclear Regulatory Commission Georgia Power Company P. O. Box 572 P.O. Box 4545 Waynesboro, Georgia 30830 Atlanta, Georgia 30302 Mr. Ruble A. Thomas Deppish Kirkland, III, Counsel Vice President - Licensing Office of the Consumers' Utility Vogtle Project Council Georgia Power Company /

Suite 225 Southern Company Services, Inc.

32 Peachtree Street, N.W.

P.O. Box 2625 Atlanta, Georgia 30303 Birmingham, Alabama 35202 James E. Joiner Mr. Donald O. Foster Troutman, Sanders, Lockerman, Vice President & Project General Manager

& Ashmore Georgia Power Company Candler Building Post Office Box 299A, Route 2 127 Peachtree Street, N.E.

Waynesboro, Georgia 30830 Atlanta, Georgia 30303 Douglas C. Teper Mr. J. A. Bailey Georgians Against Nuclear Energy Project Licensing Manager 1253 Lenox Circle Southern Company Services, Inc.

Atlanta, Georgia 30306 P.O. Box 2625 Birmingham, Alabama 35202 Billie Pirner Garde Citizens Clinic Director Ernest L. Blake, Jr.

Government Accountability Project Bruce W. Churchill, Esq.

303 10th Street Shaw, Pittman, Potts and Trowbridge Augusta, Georgia 30901 1800 M Street, N.W.

Washington, D. C.

20036 Mr. G. Bockhold, Jr.

Vogtle Plant Manager Georgia Power Company Route 2, Box 299-A Waynesboro, Georgia 30830 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 1

1 P