Monthly Operating Rept for Mar 1987
ML20206F901
Person / Time
Site: Palisades 
Issue date: 03/31/1987
From: Packard G, Vandenberg D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC
References
NUDOCS 8704140394
Download: ML20206F901 (5)


Text

-

OPERATING DATA REPORT DOCKET NO 50-255 DATE 04-01 COMPLETED BY GCPackard TELEPHONE (616)764-8913 OPERATING STATUS NOTES 1.

Unit Name: Palisades 2.

Reporting Period:

870301-870331 3.

Licensed Thermal Power (MWt):

2530 4.

Nameplate Rating (Gross MWe):

811.7 5.

Design Electrical Rating (Net MWe):

805 6.

Maximum Dependable Capacity (Gross MWe): **770 7.

Maximum Dependable Capacity (Net MWe):

    • 730 8.

If Changes Occur in Capacity Ratings (Items Number 3 through 7) since last report, give reasons:

9.

Power Level to Which Restricted, if any (Net MWe):

10.

Reasons for Restrictions, if any:

This Month Yr-to-Date Cumulative 11.

Hours In Reporting Period 744 2160 133,959 12.

Number of Hours Reactor Was Critical 0

0 69,790.3 13.

Reactor Reserve Shutdown Hours 14.

Hours Generator On-Line 0

0 66,283.1 15.

Unit Reserve Shutdown Hours 16.

Gross Thermal Energy Generated (MWH) 0 0

138,362,640 17.

Gross Electrical Energy Generated (MWH) 0 0

43,113,930 18.

Net Electrical Energy Generated (MWH) 0 0

40,582,604 19.

Unit Service Factor 0.0 0.0 49.5 20.

Unit Availability Factor 0.0 0.0 49.5 21.

Unit Capacity Factor (Using MDC Net) 0.0 0.0

  • 47.4 22.

Unit Capacity Factor (Using DER Net) 0.0 0.0 37.6 23.

Unit Forced Outage Rate 100.0 100.0 36.3 24.

Shutdowns Scheduled Over Next Six Months (Type, Date and Duration of Each):

Scheduled Maintenance, October 2, 1987, 45 Days 25.

If Shut Down at End of Report Period, Estimated Date of Start Up:

April 2, 1987 26.

Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

    • Based on condenser backpressure
  • Weighted Average (635 MWe used as MDC Net prior to October 1985)

~0C0185-0001B-0P03 8704140394 870331 DR ADOCK 05000255 PDR

{&Q

s AVERAGE DAILY UNIT POWER LEVEL i

DOCKET NO 50-255 l

UNIT Palisades DATE 04-01-87 5

COMPLETED BY GCPackard TELEPHONE (616)764-8913 MONTH March 1987 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) t 4

1 1

0 17 0

2 0

18 0

i 3

0 19 0

4 0

20 0

5 0

21 0

6 0

22 0

7 0

23 0

l 8

0 24 0

9 0

25 0

10 0

26 0

i 11 0

27 0

i l

7 12 0

28 0

13 0

29 0

'l 14 0

30 0

l 15 0

31 0

i 1

16 0

1 4

l INSTRUCTIONS:

1 i

On this format, list the average daily unit power level in MWe-Net for each

. day in the reporting month. Compute to the nearest whole megawatt.

i j

OC0185-0001C-0P03

- -. =

g DOCKET NO.

50-255 UNIT SHUTDOWNS AND POWER REDUCTIONS UNIT NAME Palisades i.

DATE 04-01-87 COMPLETED BY CCPackard REPORT MW TH March 1987 TELEPHONE (616)-764-8913 1

2 Cause & Corrective No.

Date Type Duration Reason Method of Licensee Systeg Compongnt (Hours)

Shutting hent Me Me Action to 3

Down Reactor Report #

Prevent Recurrence 1

860519 F

744 A

3 86-18 j

1 l

l 1.

2.

3.

4.

5.

F: Forced Reason:

Method:

Exhibit G - Instructions Exhibit I - Same Source S: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram Entry Sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File D-Regulatory Restriction 4-Other (Explain)

(NUREC-0161)

E-Operator Training & License Examination F-Administrative G-Operational Error (Explain)

-H-Other (Explain) l OC0185-0001D-OP03 f

\\

l

=

.. ~..

SUMMARY

OF OPERATING EXPERIENCE FOR MARCH 1987 The Plant remained shut down for repairs and maintenance during the entire month of March.

OC0185-0001E-0P03

e

.,e OrownsmG Consumers Power MEMGnN'5 PROGRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway Covert. MI 49043 April 1, 1987 US Nuclear Regulatory Commission Mail and Records Section Washington, DC 20555 LICENSE REPORT OF MONTHLY OPERATING DATA DPR-20, DOCKET NO 50-255 Enclosed is a copy of the Monthly Operating Data and a Summary of Operating Experience for the Palisades Nuclear Plant for the month of March 1987 Dewey VanDenBerg Reactor Engineer CC: KMHaas, Palisades GHGoralski, Palisades JGKeppler, USNRC KWBerry, P24-614B CSKozup, Palisades Resident Inspector, Palisades DLHackett, P11-420B MALapinski, P21-332 GWBruckmann, Div of Radiological Health Services, Lansing, Michigan SLHall, Michigan Dept of Labor RCallen, Michigan Public Service Commission Records Center, INPO, Atlanta, GA RWraylor, CE, Palisades AAAlatalo, Palisades LLBumb, P21-324 GBSzczotka, P-21-311B Document Control, 950*22*35*10/L GCP87-009 y g,,