Monthly Operating Rept for Mar 1987
ML20206F452
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 03/31/1987
From: Radford Converse, Jackie Cook
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
JAFP-87-0313, JAFP-87-313, NUDOCS 8704140256
Download: ML20206F452 (20)


Text

JAMES A. FITZPATRICK NUCLEAR POWER FIANT OPERATING DATA REPORT DOCKET to. 50-333 UNIT NAME FITZPATRICK DATE APRIL 1987 OCNPIEEED BY JOHN COOK TELEP110NE (315) 349-6569 OPERATING STATUS 1.

UNIT NAME:

FITZPATRICK IUTES 2.

REFumNG PERIOD: 870301 - 870331 3.

LICENSED THERMAL POWER (ME):

2436 4.

NAMEPIATE RATING (GROSS ME):

883 5.

DESIGN ELECTRICAL RATING (NET MWE):

816 6.

MAXIMUM DEPENDABLE CAPACITY (GROSS ME):

823 7.

MAXIMLM DEPENDABLE CAPACITY (NET ME):

794 8.

IF CHANGES OCCUR IN CAPACITY RATINGS (ntNS 3 - 7) SINCE IAST REPORT, GIVE REASONS:

NONE 9.

IWER LENEL ID WICH Kr.mlutu, IF ANY (NEL MWE):

NONE 10.

REASONS FOR RESTRICTIONS, IF ANY:

THIS bDNIH YR-70-DATE CUMUIATIVE 11.

HOURS IN REPORTING PERIOD:

744 2160 102361 12.

NUMBER OF HOURS REACIDR WAS CRITICAL:

0 356.2 73847.6 13.

REACIOR RESERVE SHUrDOWN HOURS:

0 0

0 14.

10URS GENERATOR ON-LINE:

0 355.1 71813.4 15.

UNIT RESERVE SHUIDOWN HOURS:

0 0

0 16.

GROSS THERMAL ENERGY GENERATED (Mul):

0 664368 154797490 17.

GROSS ELECIRICAL ENERGY GENERATED (&H):

0 220070 53043030 18.

NET ELECTRICAL ENERGY GENERATED (M41):

0 210865 50790S95 19.

UNIT SERVICE FACIOR:

0 16.4%

70.2%

20.

UNIT AVAIIABILITY FACIOR:

0 16.4%

70.2%

21.

UNIT CAPACITY FACIOR (USING MDC NET):

0 12.3%

64.0%

22.

UNIT CAPACITY FACIOR (USING DEE NET):

0 12.0%

60.8%

23.

UNIT FORCED OUTAGE RATE:

0 0%

12.0%

24.

SHUrDOWNS SCHEDULED OVER NEXT 6 FDNIHS (TYPE, DATE AND DURATION OF EACH):

25.

IF SHUR DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARIUP:

April 22, 1987 26.

UNITS IN TEST STATUS (PRIOR TO CDNERCIAL OPERATION):

FDRECAST ACHIEVED INITIAL CRITICALITY INITIAL ELECIRICITY C0tMERCIAL OPERATION 8704140256 870331 p

DR ADOCK 050 3

JAMES A. FITZPATRICK NUCLEAR POWER PIANE UNIT SHUrlXhNS AND POWER REDUCTIONS DOCKER NO: 50-333' UNIT NAME: FITZPATRICK DATE: APRIL 1987-REPOKr}0NIH MARCH 1987 CMPLETED BY: John Cook TELEPHONE: (315)349-6569 D

C UH R-IEIBOD S

O RO E

OF YC MC CAUSE AND CORRECTIVE ACTION AU A

SHUrrING LICENSEE SO PO TO NO.

DATE TYPE TR S

DOWN EVENT TD 0D PREVENT RECURRENCE IS O

THE REPutu EE NE O

N REACIOR M

E N

N T

1 870301 S

744 C

1

,N/A N/A N/A SHUrDOWN FOR REFUELING END OF CYCLE 7 (CUMULATIVE HOURS 1804.9) 1 2

3 4

F: EURCED REASON:

MEIBOD:

EXHIBIT G.- INSTRUCTIONS S: SCHEDULED A. EQUIPMENT FAILURE (EXPIAIN) 1-PANUAL EUR PREPARATION OF DATA B. MAINIENANCE OR TEST 2-MANUAL SCRAM ENIRY SHEEIS FOR LICENSEE C. REFUELING 3-AUIWATIC SCPAM EVENT REPORT (LER) FILE D. REGUIATORY PISTRICTION 4-0THER (EXPLAIN)

(NUREG-0161)

E. OPERATOR TRAINING AND LICENSE EXAMINATION F. ADMINISTRATIVE G. OPERATIONAL ERROR (EXPIAIN)

H. OTHER (EXPIAIN)

JMES A. FITZPATRICK NUCLEAR POWER FIMI AVERAGE MILY UNIT POWER IEEL I

DOCKET NO: 50-333 UNIT: FITZPATRICK s

MTE: APRIL 1987 COMPLETED BY: John Cook TELEPHONE: (315)349-6569 i

S lONIH MARCH 1987 i

. MY. AVERAGE MILY-POWER IEEL MY AVERAGE-MILY POWER LEVEL 114e NET Mie NET 1 1 0

~17 0'

2 0

18 0

1 '

3 0

19 0

4 0

20 0

5 0

21 0

6 0

22 0

t-17 0

23 0

8 0

24 0

i f

0 25 0

9 10 0

26 0

11 0

27

-O 12 0

28 0

i -

13 0

.29 0-14 0

30 0-15 0

'31 0-16.

0 SIMRRY: 'Ihe FitzPatrick plant remained shutdown for refueling for the entire.

reporting period.

k i

s N

~

~

-NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE L

!~

MARCH 1987

.The FitzPatrick plant remained shutdown for refueling this entire reporting. period.

The estimated date of startup is April 22,-1987.

L C

i L

i 4

i

NEW YORK POJER AUIHORITY JAMES A. FITZPATRICK NUCLEAR POWER FIANT MAINTENANCE SUtEARY DOCKEI NO:

50-333 UNIT NAME:

FITZPA'IRICK DATE:

APRIL 1987 CmPIZrED BY:

JOHN COOK FDR 'IHE M)NIH OF: MARCH 1987 TELEPHONE:

(315) 349-6569 WRK REQUEST NO.

HGJ CAUSE OF RESULTS OF ACTION TAKEN 'ID REPAIR DATE SYSTEM h NENT NO.

DETECIED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TDE HOURS 870313 00 050539 JIC PER JTS-86-839 NO FAILURE; REPLACE COVER 10 VARIOUS REPLACE COVER GASKETS GASKETS 870327 02 032852 JIC AGE REPLACE REPLACED CAPS AND 20 INV-801A,B ELECTROLYTIC CHECKED LOW SENSOR CAPACITORS 870317 02 050736 JIC DRIFT 1238,121D 0/0 ISP-203 CALIBRATION 4

RTD-123B TOLERANCE DURING ISP-203 870224 02-3 043331 JIC COULD NOT GROSS FAILURE NONE 5

MTU-201C DUPLICATE FAILURE LIGHT 870311 02-3 050571 JIC ANNUN MUST BE REMOVE TRIP UNITS REMOVE; REPLACE AFTER 2

MTU-283A CLEAR FOR 02-3C FOR PRE-OP-02-3C TEST (NO FAILURE) 870324 02-3 050572 JIC P.M.

PERFORM ISP-200A PERFORMED ISP-200A 4

PT-55A ON 02-3-PT-200A NEW YORK POWER AUIBORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT MAINIENANCE SIM4ARY DOCKET NO:

50-333 UNIT NAME:

FITZPATRICK DATE:

APRIL 1987' OCNFLETED BY:

JOHN 000K FDR THE FONIH OF: MARCH 1987 TELEPHONE:

(315) 349-6569 WRK REQUEST NO.

HOR CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM COMPONENT NO.

Drmam MALFUNCTION MALFUNCTION PRECLUDE RFA RRENCE TIME EOURS 870327 02-3 050702 JIC THREADS ARE IN REPLACE REPl. ACED PER 2

LT-72B BAD SHAPE TEST / DRAIN PER ISP-276B, VALVE BLEED AIR 870224 02-3 050708 JIC BAD DIODE BLOWN FUSE REPLACE F1, CR16 15 MTU-255C ON MTU DIODE IN5646 870310 02-3 050730 JIC GAIN, ZERO, SPAN OUTPUT NOT IMP-2-3.1 2

SQRT-74A OUT OF SPEC PROPERLY SATISFATORY l

ADJUSTABLE 1

870313 02-3 050731 JIC DIODE S/N 210401 CAtNOT CALIBRATE REPLACED FROM STOCK; 20 I

SQRT-74R 2928 DEFECTIVE MIDDLE RANGES

. IMP-2.3.1 OK 870319 02-3 050735 JIC BOTH AMPLIFIER B READS DOWNSCALE REPLACE, CALIBRATE 28 FT-648,D BOARDS BURNED D READS UPSCALE IMP-2-3.1 870107 03 050544 JIC SIMULATE ROD NONE; INST TEMP INSTALL JUMPER 6

ROD POSITION FULL-IN JUMPER ON BOARD 870203 03 050669 JIC ALARA NO FAILURE; FLUSH FLUSH, IMP-T19 20 LS-231A.B SDIV LEVEL SWTCHS. -

NEW YORK poler AUIHORITY JAMES A. FITZPATRICK NUCLEAR POWER FIANT MAINTENANCE SIFNARY DOCKET No:

50-333 UNIT NAME:

FITZPATRICK DATE.

APRIL 1987 OWPIErED BY:

JOHN COCK FDR THE FDNIH OF: WRCH 1987 TELEPHONE:

(315) 349-6569 WRK REQUEST NO.

HOR CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM C WPONENT NO.

DETECTED MALFUNCITON MAIRJNCTION PRECLUDE RECURRENCE TIME HOURS 870314 03 050683 JIC DIRTY SWITCH WATER LEVEL CLEAN SWITCH 12 HCU-26-07 INCID. INOP INSTALL NEW DURING IMP-3.5 0-RING; IMP-3.5 870312 03 050684 JIC DIRTY SWITCH WATER LEVEL INDIC.

REMOVE, CLEAN, 12 HCU-30-43 INOP DURING REPLACE IMP-3.5 870312 03 050689 JIC DEFECTIVE WATER LEVEL INDIC.

REPLACE SWITCH, 12 HCU-30-35 SWITCH INOP DURING DETECTOR; IMP 3.5 IMP-3.5 870312 03 050690 JIC DEFECTIVE H2O LVL DETECTOR REPLACE; IMP-3.5 100 HCU-38-39 SWITCH FAILED IMP-3.5 870313 03 050692 JIC DEFECTIVE WATER LEVEL INDIC.

REPLACE SWITCH, 15 HCU-14-23 SWITCH INOP DURING DETECTOR; IMP-3.5 IMP-3.5 870314 03 050726 JIC DIRTY SWITCH SWITCH CLEAN; REPLACE 9

HCU-26-51 UNSATIFACTORY O-RING IN IMP-3.5 3

IEW YORK POWER AUIHORITY JAMES A. FITZPATRICK NUCLEAR POWER PIMr MAINTENANCE SIWARY DOCKET No:

50-333 UNIT NAME:

FITZPATRICK DATE:

APRIL 1987 O@!PIETED BY:

JOHN COOK FOR THE FONTH OF: MARCH 1987 TELEPHohT:

(315) 349-6569 WRK REQUEST NO.

HOR CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM C mPONENT NO.

DETECIED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TIME HOURS 870329 03 051250 OPS MOD F1-86-098; REPLACE ROD PREWORK TESTS, 90 Z11 CONST. DOCUMENT SELECT PANEL REPLACE 870305 03 051302 OPS NONE FOUND SPURIOUS ROD IMP-3.7: OK; NO ALARM 8

ROD 02-27 DRIFT ALARMS WITH TEST BOX 870314 03 052372 JIC DIRTY SWITCH SWITCH FAILED INSPECT, CLEAN; 12 HCU-18-47 DURING IMP-3.5 IMP-3.5 OK 870207 03 052452 OPS MOD M1-87-011 NO FAILURE; INSTALL NEW 60 DPT-231C,D REPLACE CONNECTORS; CONNECTORS ISP-66-4 870303 03 052998 OPS BAD PROBE BUFFER BAD ROD POSITION REPLACE; IMP-3.7 12 ROD 10-47 CARD INDICATION WORKS OK 870305 03 053049 OPS SHORTED CONSTANT DRIFT REPLACE FROM STOCK 12 ROD-26-35 TRANSISTOR ALARM 870210 05 052882 OPS USE/ ABUSE DAMAGED RELAY REPLACE FROM STOCK; 160 SA-K16A IMP-71.18

-4_

NEW YORK POWER AUIRORITY JAMES A. FITZPATRICK hTCLEAR POWER FIANT MAINTENANCE SIM%RY DOCKET No:

50-333 UNIT NAME:

FITZPA'IRICK DATE:

APRIL-1987 COMPLETED BY:

JOHN COOK FOR 'IHE FONIH OF: MARCH 1987 TELEPHONE:

(315) 349-6569 WRK REQUEST NO.

HOR CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM N 1PONENT NO.

DEnLTw MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TIFE HOURS 870311 07 041642 OPS NOT ENOUGH "C" COUNT CIRCUIT RESET; REPAIR AND 4.5 APRM F LEVEL INPUTS NEEDS RESET RESTORE DURING TO 111 OUTAGE 860925 07 044455 OPS IV CURVE DONE; SEEMS TO BE OBSERVE LPRM FOR 2

LPRM 20-37D LOOKS SATISFACT.

DRIFTING PROPER OPERATION 860925 07 045312 OPS IV CURVE DONE; SEEMS TO BE OBSERVE LPRM FOR 2

LPRM 20-298 LOOKS SATISFACT.

DRIFTING HIGH PROPER OPERATION 860925 07 045332 OPS BAD CARDS CALIBRATION REPLACE FROM STOCK 3

LPRM CARDS CURRENTS ARE OFF 870307 07 050518 JIC P.M.

REPLACE DURING REP. DETECTORS, 410 LRM DET'S OUTAGE CONNECTORS, ETC.

870307 07 050681 JIC AS NEEDED DURING REPLACE DETECTORS REPLACE VARIOUS; 250 VARIOUS DRY TUBE JOB DRY TUBES, PARTS RETURN TO SERVICE 870325 07 050722 JIC NATURAL FAILURE DETECTOR LEAKING INSTALL NEW UNIT, 58 LPRM 20-45 CONNECTORS

~

NEW YORK POWER AUIHORITY JAMES A. FITZPATRICK NUCLEAR POWER PIANT MAINIENANCE SI1 MARY DOCKER to:

50-333 UNIT NAME:

FITZPATRICK DATE:

APRIL 1987 CW PLETED BY:

JOHN COOK FOR THE FDNIH OF: MARCH 1987 TELEPHONE:

(315) 349-6569.

WORK REQUEST NO.

HOW CAUSE OF RESULTS OF ACTION TAKEN 'ID REPAIR DATE SYSTEM C WPONENT NO.

DETECTED MALFUNCTION PRLFUNCTION PRECLUDE RECURRENCE TIME HOURS 870305 07 2'1722 JIC WHEN DRAWER WAS d6 CONNECTOR REPAIR USING OLD 8

SxM-B PULLED OUT CAME APART CONNECTOR 870314 07 050742 JIC BAD CAPACITOR SV SUP. RIPPLES &

REPLACE CAP AND TEST 8

APRM A PS25 MAX APPROX. 4.7V 870317' 07 050744 JIC BAD VR2 BOARD CANNOT ADJUST REPLACE, IMP-7.6 4

APRM C REGULATOR PROPERLY 870319 07 050748 JIC DEFECTIVE LPRM ZERO CALIBRATION REPLACE FROM STOCK; 2

APRM A CARD 44-45D,44-13D CALIBRATE TOLERANCE 870318 07 050749 JIC CONNECT DUNKING NO FAILURE CONNECT FLC TO 24 SRM B CHAMBER IN PLACE SRM B DRAWER OF SRM B IMP-7.17 870306 07 052897 OPS PREPARE FOR NO FAILURE; CHECK CONNECT SRM "B";

60 FUEL LOADING USE IN CORE DUNKING CHAMBER IMP-7.17 RELOADING NEW YORK P0kER AUIHORITY JAMES A. FITZPATRICK NUCIEAR POWER PLANT MAINIENANCE Silt 4ARY

~

DOCKET No:

50-333 UNIT NAME:

FITZPATRICK DATE:

APRIL 1987 CWPIEEED BY:

JOHN COOK EDR THE FDNIH OF: t%RCH 1987 TELEPHONE:

(315) 349-6569 VORK REQUEST NO.

HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM CmPONENT NO.

DEIECTED MALFUNCTION MAIRJNCTION PRECLUDE RECURRENCE TIME HOURS 870316 07 053334 OPS BAD MOTOR RED PEN NOT REPLACE, CALIBRATE 10 R-45 RESPONSIVE IMP-G14 870323 07 053350 OPS BAD DETECTOR FAILED DOWNSCALE REPLACE FROM STOCK; 55.5 SRM B AFTER ST-5 IMP-7.2 870321 07 053448 JIC P.M.

CALIBRATE CALIBRATED; ADdUSTED 3

PR-46C RECORDER SPAN RED & BLACK PENS 870326 07 053450 JIC NCA-533 CALIBRATE RECIRC CALIBRATE USING 4

FU-144A,D FU'S GEK-346678 AS REF 870324 07 053547 OPS LOOSE SCREWS BLACK PEN TIGHTEN SCREWS; 3

PR-46D DOESN'T RESPOND IMP-7.28 870318 08 053349 OPS BAD LOAD CELL GRAPPLE NORM UP REPLACE; CHECK OTHER 24 58A-LS-4 IN TOO SOON COMPONENTS 870309 10 050729 JIC BLOWN FUSE F2 FAILED DURING REPLACE UNIT 16 P/S-101A IMP 10.2 NEW YORK POWER AUIHORITY JAMES A. FITZPATRICK NUCLEAR POWER FIANT MAINTENANCE SUtEARY DOCKET NO:

50-333 i

UNIT NAME:

FITZPATRICK DATE:

APRIL 1987 OPPIEIED BY:

JOHN 000K FOR THE lONIH OF: MARCH 1987 TELEPHONE:

(315) 349-6569~

t WRK REQUEST NO.

HOW CAUSE OF RFRILTS OF ACTION TAKEN TO REPAIR DATE SYSTDi C mPONENT NO.

DETECTED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TDE HOURS

[

870326 12 050740 JIC DAMAGED DURING REPAIR OR REPLACE dB COVER AND 6

TE-117 OUTAGE REPLACE TE GASKET 870317 13 032851 JIC AGE REPLACE REPLACE CAPACITORS; 8

INV-152 ELECTROLYTIC MAKE NECESSARY CAPACITORS ADdUSTEMENTS 870331 13 052257 OPS BAD CONNECTOR SPEED PICKUP REPAIR COtNECTOR 5-TU-2 SEEMS TO BE BAD 870325 14 053321 OPS DEFECTIVE METER AffiETER REMAINS REPLACE FROM STOCK 20 PI-48A AT 90 AMPS 870320 16-1 038761 JIC P.M.

SEND INSTRUMENTS REMOVE;SEtO; REPLACE 6

DPIT-101, 102 TO MANUFACTURER NO FAILURE FOR CALIBRATION 861118 17 045392 OPS UNKNOWN SPURIOUS FALSE MONITOR REPLACED MOD 6

RM-251B DOWNSCALE ALARM F1-84-038 NEW YORK POWER AUIHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT MAINIENANCE SlWARY DOCKET NO:

50-333 UNIT NAME:

FITZPATRICK DATE:

APRIL 1987 OCNPIETED BY:

JOHN COOK FDR 'IHE leml 0F: MARCH 1987 TELEPHONE:

(315) 349-6569 i

UORK REQUEST NO.

HOR CAUSE OF RESULTS OF ACTION TAKEN 'IO REPAIR DATE SYSTEM CWPONENT NO.

DeatInto MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TIME HOURS 861014 17 046414 JIC DETECTOR LOW RANGE NEEDS MONITOR REPLACED MOD 6

RM-150A SENSITIVITY, CALIBRATION F1-84-038 AGING 870324 17 053446 JIC NEW VALUES CHANGE PERFORM ADJUSTMENTS 1

RM-251A,8 CALCULATED IN SENSITIVITY PSP-14 FACTORS 870328 17 053451 JIC METER READINGS CHANGE RAN APPL. TEST; SET 3

RM-150A,B OF PSP-14 SENSITIVITY SENSITIVITY FACTORS 870312 23 032850 JIC P.M.

REPLACE REPLACE, ADJUSTMENT 12 INV-79 ELECTROLYTIC CAPICITORS 870328 23 050573 JIC LOOSE WIRES BLOWN FUSE IN REPLACE LEADS, FUSE; 2

MTU-268B CROSSED PANEL 9-96 ISP-225B 870324 23 051324 OPS P.M.

REPLACE DEF.

REPLACE SNUBBER 2

PCV-50 SNUBBER

_g-

NEW YORI; POWER AU1BORITY JAMES A. FITZPATRICK NUCLEAR POWER PIANT MAINIENANCE SIMfARY DOCKER NO:

50-333 UNIT NAME:

FII2 PATRICK-DATE:

APRIL 1987 00fPIEIED BY:

JOHN COOK FOR THE 10NIH OF: MARCH 1987 TELEPHONE:

(315) 349-6569 WRK REQUEST NO.

HOW CAUSE OF RESULTS OF ACTION TAKEN 10 REPAIR DATE SYSTDI C W PONENT No.

DEFECIED MALFUNCTION MAIFUNCTION PRECLUDE RECURRENCE TIME HOURS 870327 23 053466 JIC THERMOCOUPLE REPAIR / REPLACE ORDER NEW; REPLACE,

'12 TE-127 BLOCKS SHORTED TICPJiOCOUPLE CHECK READING 870307 23 013292 JIC TRANSMITTER HAS BELOW ZERO REPLACE TRANSMITTER 23 PI-101 NO OUTPUT INDICATION 870307 27 052438 OPS IMPROPER FIT COtNECTOR FELL GLUED PROBE TERMINAL 1.5 RM-101,102,103 OFF BOARD INTO SLOT 870323 27 053447 JIC BAD RESISTORS PR-100 INOP REPLACE;-RUN ISP-4-4 10 PR-100 DURING ISP-4-4 870325 33 050570 JIC P.M.

PERMCifi ISP-200A PERFORMED ISP-200A 8

PT-135A 870317 46 050734 JIC UPGRADE RELAYS REPLACE 63A'S, REPLACE USING 24 HFA RELAYS 63B'S IMP 71.18 870126 66 036303 OPS P.M.

INSPECTION, CHECK, ADJUST, IF 200 AC-INV-3A CALIBRATION NEEDED NEW YORK POWER AU1HORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT N NY DOCKET NO:

50-333-UNIT NAME:

FITZPATRICK-DATE:

' APRIL 1987 C0iPIETED BY:

JOHN COOK FOR THE WNIH OF: MARCH 1987 TELEPHONE:

(315) 349-6569 M)RK REQUEST NO.

HOW CAUSE OF RESULTS OF ACTION TAKEN 10 REPAIR-DATE SYSTEM CQ4PONENT ND.

DETECTED MAIR1NCTION MAIR1NCTION PRECLUDE RECURRENCE TIME

'r00RS 870129 66 045319 OPS NO PROBLEM FOUND ERRATIC DIFF.

CHECKED; OK 1

ACCU-3B t'1FSS. INDIC.

870123 66 050542 JIC WEAR FAULTY SWITCH REPLACE FROM STOCK; 8

ACCU-38-IH IHCP2 CALIBRATE I

i 870309 66 050627 JIC MOD F1-84-005 INSTALL INSTALL TEMP DAMPER 6

ACCU'S ECR-072 PULSATION ON 1B DAMPERS 870128 66 051299 OPS NO PROBLEM FOUND HPCI GAUGE SEE WR 66/50627 1

i ACCU-4A FLUTTERS i

870310 66 052479 JIC MOD F1-84-005 INSTALL INSTALL, TEST 12 ACCU'S ECR-072 PULSATION DAMPERS 870324 71 050623 JIC VENDOR-REQUIRED NONE-P.M.

P.M. S IMP-71.20 40 INV-3A,3B P.M.

WITH EXIDE -_

..l*~

yyym JAMES A. FITZPATRICK NUCLEAR POWER FIANT MAINTENANCE SIM4ARY DOG Er NO:

50-333 UNIT NAME:

FITZPATRICK DATE:

. APRIL 1987-OG4PLETED.BY:

JOHN 000K FOR THE MNIH OF: WRCH-1987 TELEPHONE:

(315) 349-6569 WORK REQUEST NO.

HOW CAUSE OF RESULTS OF ACTION TAKEN TO -

REPAIR-DATE SYSTEM Ca"PONENT NO.

DETECTED MAIRJNCTION MALFUNCTION PRECLUDE RECURRENCE TIME L

HOURS

!4 870302 71 053088 OPS LEG FUSE INVERTER REPLACE LEG FUSE; 21 INV-3B BLOWING FUSES SWAP LEGS - OK 870304 93 051966 OPS BAD' RELAY ESW ALARM IN REPLACE FROM STOCK; 22-EDG-C TEST AM) ADJUST s

l 870304 93

_0J3084 OPS DRIFT OUT OF T.S.

IMP-93.5; WAS OK 3

LI-101D TOLERANCE SS OK'D 4

I j

1 w,

l

NEW WRK POWER AUIHORITY JAMES A. FITZPATRICK NUCIEAR POWER PLANT SAFE 1Y RELATED ELECIRICAL & MECHANICAL MAINIENANCE S& NARY

~

l MARCH 1987

.KrzAIR WORK REQUEST #

TIFE DATE SYSTEM CCHPONENT HOW DETECTED CAUSE OF MALWNCTION ACTION TAKEN TO PRECLUDE RECURRENCE HOURS 3/4 93 51618 PM Heater elenent short Replaced heater elements 36 WIT-3E & 3D

.-__ ----__----=_______==----___== _====_

3/7 39 53177 LIRT

. Seat leak Overhauled valve 4

EK5 5

__-------.....--_--------------_......__ _= =__===_-- -===_--_---------__--_-__----_===__

3/5 39 52707 IIRT Seat leak Overhauled valve 4

EK5 6

_------___-----------==_===-

. =--_---_ --_-----_-==_

=_ _ _ _ - - - - _ - - - - - = _ _ _ _ = - - - _ - - _. _ = _ _ = = = - - _ - - - - - - - - - - - - - - -. - - - - - - - - - -.

3/2 13 52642 LIRT Seat leak Overhauled valve 20 E TC 03 3/2 13 51608 LIRT Seat leak Overhauled valve 4

RCIC-05 3/7 02 50038 OPS Worn seal Rebuilt seal 43 P-1B


__ __--------_--------_.--==_ _--__ -----_------------_ -------_----------_ ---_--_-----_--_-___--_-_--_---------.

3/7 15 52890 LIRT Seat lenk Overhauled valve 9

ADV-T30B 3/2 14 38149 OPS Worn packing Replaced packing 2

XDV I3A

- _ - - - - - _ - - - - - - - - - - - - - - - _ _ _ - _ - - - - - - - - - - - - - - - - - - - - - _ _ _ - - _ = = - - - - = - _ - - - - _ - _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ - - - - - - - _ _ - - - _ - - - - - - - - - - -

3/3 27 52701 LIRT Worn seat Overhauled valve 4

SOV-124A

__.__----------_-------__------_----_----------------_----_-----_---- -----_-___--. -=========- = -

= = - - - - _ - - - _ = _ = = = _ - _ _ _.

3/6 10 51498 OPS Worn packing Replaced packing 3

FDV T48A


__-_----__----_----_----------___---------_-------_---__-====_- _--_-

_-----_------ _ = -___-----

_ = = = - - - - - = - - - -===

3/5 34 52735 LIRT Seat leak Overhauled valve 20 1

NRV IllB

-_-__-_-_-_ -_-_---________-_--_-_--_-____-_--_-___----_-_---__--_-_ ___----_ -_====- - _____ -

=__-_ --_----_--_-__----==-___.

i 3/16 15 52889 LIRT Seat leak Overhauled valve 45 3DV I31B


__---------_----------_------ _==-----

- = -

__---- _-- __=__

=== =--- = _-==--======-----------------.

1 3/14 15 52702 LLRT Seat leak Overhauled valve 20 A0V-132A 2

--===------_==-

-==_ ---=--==- -----_-----__--__-----_-------------------------_--===-

= - _ _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

NEW YORK POWER AUIHORITY JAMES A. FITZPATRICK NUCLEAR POWER FIANT SAFETI RELATED FJFCIRICAL & MECHANICAL MAINTENANCE SUWARY MARCH 1987 REPAIR kORK REQUEST f TIFE DATE SYSTEM C WPTENT HOW DEIECTED CAUSE OF MAIJUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE HOURS 3/20 10 46550 OPS Worn packing Replaced packing 15 RHR-694 3/15 15 52043 LIRT Worn packing Overhauled valve 22 ADTT30A 3/18 46 52141 ISI Corrosion Overhauled valve 5

E59'Z2A 3/13 46 52136 ISI corrosion Overhauled valve 5

E57-T9B 3/13 46 52140 ISI Corrosion Overhauled valve 5

E57211B 3/13 46 52138 ISI Corrosion Overhauled valve 5

EST 70B 3/16 46 52143 ISI Corrosion Overhauled valve 5

EST7A 3/17 10 34499 OPS Worn packing Replaced packing 6

FDV T0 3/17 02-2 50764 PM None Replaced seals 185h P-1A 3/18 46 52139 ISI Corrosion Overhauled valve 5

EST 71A 3/30 29 52888 LLRT Seat leak Overhauled valve 126 FDV 74 3/26 15 52715 LLRT Seat leak Overhauled valve 15 REC 216B 3/27 23 52990 LLRT Seat leak Overhauled valve 119%

HPI-12

~0 NEW YORK POWER AITDKRITY

+

JAMES A. FITZPATRICK NUCLEAR POWER PLANT SAETY REIATED ELEC1RICAL & MECHANICAL MAINIENANCE SubHARY 9-MARCH 1987 IUTAIR WORK REQUEST f TDE l

DATE-SYSIDi C(NPONENT HOW DEIECTED CAUSE OF MAIRJNCTION ACTION TAKEN TO PRFfLUDE RECURRENCE HOURS 3/25 27 52887 IlRT Seat leak Overhauled valve 139 EV 123


_=

..===_-----------_

___=== ---------------------------------------------,

3/25 10 53345 LIRT Seat leak Overhauled valve 156 boV-17


_===_ --------------------------------------------------------------------- ___=_==___=-------------------,

3/20 12 52697 LIRT Seat leak Overhauled valve 59%

i WV-18


=__=____ ---------------- _

N 3/27 12 52717 LIRT Seat leak Overhauled valve 16 RE~52 3/24 10 52917 LIRT Seat leak Overhauled valve 42-EV 31B


___ - - - - - _ _ _ ------------------------------------=__=__ _. --_ _ _ _ - - -,

3/18 12 52696 LIRT Seat leak Overhauled valve 144%

EV I5 3/26 16-1 52653 LIRT Seat leak Overhauled valve 9

EV T02B


-_ ------ ___=__=_===--------------------.------------=_

l 1

a 4

}

u J

1

James A.FitzPCtrick

~D Nuclear Power Plant P.O. Box 41 Lycoming, New York 13093 315 342.3840 Memorandum

  1. > NewWrkPbwer tv Authority April 9, 1987 JAFP-87-0313 Director, Office of Inspection and Enforcement U.S.

Nuclear Regulatory Commission Washington, D.C.

20555 t

ATTENTION:

DOCUMENT CONTROL DESK

REFERENCE:

DOCKET NO. 50-333

Dear Sir:

Enclosed please find the d. A.

FitzPatrick Operating Status Report for the month of March, 1987.

If there are any questions concerning this report, please contact John Cook at (315) 349-6569.

m RAD

d. CON ERSE RESIDENT MANAGER ft.D RdC:d.C:mac Enclosures cc:

Distribution