Special Rept 87-002-00:on 870319,filtration,recirculation & Ventilation Sys post-accident Radiation Monitor Serviced & Inoperable More than 72 H.Caused by Equipment Failure During Test.Alternate Requirements Satisfied
ML20206C550
Person / Time
Site: Hope Creek 
Issue date: 04/03/1987
From: Ervin A, Salvesen R
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
87-002-00, 87-2, NUDOCS 8704130084
Download: ML20206C550 (4)


Text

inac F e set u o mucteam neoukJ.foM? Co.asiesoas

' 8 38 Apr8tovt)Ones eso 3 eedios LICENSEE EVENT REPORT (LER)

..c.ury e n, oocaer nu = = m ra= as Hope Creek Generating Station ol5Iololo131514 1 loFlf) 13

" ' ' ' '

  • Filtration, Recirculation and Ventilation System (FRVS) Post Accident Radiation Monitor Inoperable For More Than 72 Ilou rs eve =1 oave m Lea musseen see menoaromve m ornea enciuties i=voLveo e

QM ',

['j,0 esonstM OAV vtAR

..ci6ste m.wes pocatf Nuweemiss MONTN 047 vtA4 Yt.4 01sl0lol0l l l 0l3 1l 9 8

7 Rl 7 Nl Al l

0l 4 0l3 8l 7 0 5to Io e ol l l

~

~

twee aseone se oue.irtso numeuant to tus naouinsme=rs ce se Cen a tea..

.*,a.a.<>.

gs nu "8**

  • I se esem se.seio es niensni.

r tem

= =..mm u ni.nu m inimi.,

neuw

_ x g=,e gs g.,4.,..,=,

nei e i n.nemmm w miam wemim

. n,m4 n.

m.s

.,me.,

.,mn,n,,

so memmini ee tmimm eera nen.mnoi Special Report se emes.mno se,mnsu.,

se innen.'87-002 UC08sete Cosef act Pos TMie 4tm Itti 9.wt TEL8P 044 Nupean

.A4.Coct A.

M.

Ervin, Lead Engineer - Technical Al nl 9 11 al al -l 'i l 2 l 31 9 co u,.... u.......c. e-.,...Lu.. o. ec.,0.o i= r,e...o., n i, CAult 979f f W cot 88040 % f

,',",'[

O

y"h0

" 8,

"'8 C.984 878?tW Cour"%tNf I

I l i i i l i

I I I l l l l

l 1 1 I I I I

I 1 l l l I ou u... L...,....e,. o n.,

oo~,-

..Y fit It!..e ee%ea. C.*SCT60 CVe4 Fit!ON Qe tti

%Q l

l l

....a,_,,....-........,n.,

The Plant wan in OPERATIO!1AL CO!1DITIO!1 1 (Power Operation) at 69%

power

- 750 f two.

The PRVS Post Accident Radiation Monitor was taken out of corvice on March 19, 1987 at 0930 hourn to perform a acheduled gan officiency determination.

The Action Statomont of Technical Specification 3.3.7.5 was ontored at the time.

The i

Action Statomont requiron that either the rioble Gau Monitor be rootored to operable otatun within 72 houro or the proplanned alternato method of monitoring the PRVS Vent Plow be initiated and a

Special Report be oubmitted to the flRC within 14 days.

The

!!ablo Gac ttonitor wan rectored to corvice on March 25, 1987 at 2350 houro and the Action Statomont was terminated.

Ilowever more than the allowed 72 hourn had clapood since the Action Statomont wan ontored.

The alternato requiremontu of the Action Statomont woro antinfied by (A)

The operable low rango tioblo Gan Monitor which continuounly monitorn the PRVS Vent Plow and (D)

Thin report.

0704130004 070403 PDR ADOCK 0D000354 5

PDH

.e.., see I s.2. g

~

mac P.rm 3864 U S. muCLE*A R40WLt.70RY COMMIS8soes UCENSEE EVENT REPORT ILER) TEXT CONTINUATION

      • aovio oue no sisa-cio.

inPinES SiJt tl

'L'I T **## "I lDoCast muassen ag' Ltm muwetR les Pact (3 "tO'?

"'#.0 "aa N lA l l

0l2 cF 0 13 Hope Creek Generating Station 0151010l0l3l5[4 8l 7 rano u

= wmm.mn ELADT ADD SYSTEB IDENTIFICATIDE General Electric - Boiling Water Reactor (DWR/4)

Filtration, Recirculation and Ventilation System (FRVS)

(EIIS Designator:

IL)

IDENTIElCb21DD DE DCEDEBEBCE Filtration, Recirculation and Ventilation System (FRVS)

Pont Accident Radiation Monitor Inoperable For More Than 72 Hours.

Event Date:

03/19/87 Event Time:

0930 CDDD111DDB ERLDE TD DECDEBBBCE The plant was in OPERATIONAL CONDITION 1 (Power Operation) at 69%

Power - 750 MWo.

DESCD1211DD DE DCCDEBEDCE The FRVS Post Accident Radiation Monitor was taken out of nervice on March 19, 1987 at 0930 hours0.0108 days <br />0.258 hours <br />0.00154 weeks <br />3.53865e-4 months <br /> to perform a

scheduled gas efficiency determination.

The Action Statement of Technical l

Specification 3.3.7.5 was entered at the time.

The Action Statement requires that either the Noble Gao Monitor be restored to operable status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or the preplanned alternate method of monitoring the FRVS Vent Flow be initiated and a Special Report be submitted to the NRC within 14 days.

The Noble Gas Monitor was restored to acrvice on March 25, 1987 at 2350 hours0.0272 days <br />0.653 hours <br />0.00389 weeks <br />8.94175e-4 months <br /> and the Action Statement was terminated.

Ilowever more than the allowed 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> had clapacd since the Action Statement was entered.

The alternate requiremento of the Action Statement were antisfied by (A) The operable low range Noble Gao Monitor which continuously monitors the FRVS Vent Flow and (B) This report.

h2EbEEDT CbDBE DE DCCDBBEDCL The root cause of thin occurrence in equipment failure during the performance of a acheduled test, hDhEYB1B DE DCCDBBEDCE During the performance of the Iligh-Range CD TE Effluent Monitor Gas Efficiency Determination (RP-TE.SP-012(Q)) on the Noble Gas Monitor (lSP-RE-4811B2) the connector on the cable running from the electronica onclonure to the mid-range detector was observed to be intermittently non-functional.

A replacement connector was not availabic from atorea and it was necessary to purchase the needed replacement from local commercial sources.

.I 4 480;w 34ea q

meC fore 2004 y 8 NUCLt*R s tiuLif0mv COh848tSSION LICENSEE EVENT REPORT (LER) TEXT CONTINUATION

      • aovto ous ao 3tio-otoa tapint$ 8/3115 Pacessf y maast ets Docusf mutsetR up Lin NutsetR f 61 Pact (3i

" t C."

"'0lu:

n'*

l 013 0F 0l3 Hope Creek Generating Station 0l5[0l010l31514 81 7

, Nl N Ton w =n om. m-u m.ama nw u. mw.nm ANALYB1B DE DECDBBBBCE CDET*.,D The replacement connector was installed under work order 87-03 011-6 and tested satisfactorily.

j Special Report 86-004 (October 17, 1987) reported an earlier i

occurrence which was similar to the subject of this report.

In

]

this earlier occurrence the Mid-Range Noble Gas Monitor for the 1

FRVS Vent was out of service for more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

The cause of this earlier occurrence was intermittent functionality of the detector due to a crimped cable.

Since the FRVS Vent Path was monitored by the preplanned alternate method of monitoring during l

the period in which the Post Accident Radiation Monitor was inoperable, any release which occurred would have.been detected and safety systems would have actuated to prevent a release in l

l excess of that permitted by Technical Specification 3.11.2.5.

During this time FRVS did not operate, indicating' that no abnormal releases occurred.

For these reasons the health and safety of the public was not threatened by this occurrence, r

CDEBECT125 hCTIDEB The FRVS Vent Noble Gas Monitor was

repaired, retested satisfactorily and returned to service.

l Sincerely, j

l

&c-l R. S.

Salvesen, l

General Manager -

llope Creek Operations l

A'IEstlb SORC Mtg.87-042 l

l l

l

($ 436

O PSEG Pubhc Service Electric and Gas Company P.O. Box ( Hancocks Bridge, New Jersey 08038 Hope Creek Operations April 3, 1987 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Dear Sir:

HOPE CREEK GENERATING STATION-DOCKET NO. 50-354 UNIT NO. 1 SPECIAL REPORT 87-002-00 This Special Report is being submitted pursuant to the requirements of Technical Specification 3.3.7.5.

Sincerely,

/