ML20206A162
| ML20206A162 | |
| Person / Time | |
|---|---|
| Site: | Catawba |
| Issue date: | 03/19/1987 |
| From: | Tucker H DUKE POWER CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NUDOCS 8704070435 | |
| Download: ML20206A162 (2) | |
Text
_ _ - _ _ _ _ - _ _ - _ _
e7 f
DUKE POWER GOMPAhT P.O. HOX 33180 CIIAHLOTTE, N.O. 28242 HALB. TUCKER TELEPHONE vum PBessonNT (704) 373-4 531 NU0 LEAR PROlptTTION March 19, 1987 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555
Subject:
Catawba Nuclear Station, Unit 2 Docket No. 50-414 Gentlemen:
Pursuant to Technical Specification 3.3.3.6 and 6.9.2, please find attached a Special Report concerning the inoperability of the Reactor Coolant Radiation Level monitor (2 EMF-48).
Very truly yours,
/
.i?
-l Hal. B. Tucker RWO/38/sbn l
Attachment rc:
Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. P. K. Van Doorn NRC Resident Inspector Catawba Nuclear StationDirector Director P)/
Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission I
Washington, D. C.
20555 870407043S 870319 PDR ADOCK 05000414 PDR
~e SPECIAL REPORT REACTOR COOLANT RADIATION MONITOR INOPERABLE On March 5,1987, the sample flow for the Unit 2 reactor coolant radiation monitor (2 EMF-48) was isolated due to leakage of valve seats on Inside Containment Isolation Valves 2NM-22A, 2NM-25A and 2NM-42S. The Outside Containment Isolation Valve, 2NM-26B, has been closed in order to comply with the Containment Isolation Technical Specification.
Work Requests have been written to have the affected valves inspected and repaired during the next outage of sufficient duration.
l