Forwards Insp Rept 50-267/87-04 on 870126-30.No Violations Noted.Deficiencies Noted in Encl App a Involving Potential Enforcement/Unresolved Items Will Be Referred to Region IV for Further Action
ML20205T514
Person / Time
Site: Fort Saint Vrain 
Issue date: 04/03/1987
From: Merschoff E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: Robert Williams
PUBLIC SERVICE CO. OF COLORADO
Shared Package
ML20205T521 List:
References
NUDOCS 8704070313
Download: ML20205T514 (5)


See also: IR 05000267/1987004

Text

-

_

1

j

-s

.

-

.

,

!,,, .g'o{

.

UNITE 3 STATES

.

8

NUCLEAR REGULATORY COMMISSION

~

n

wAsHWGTON. D. C. 20886

t,

.. j

\\

/

April 3, 1987

Docket No. 50-267

Public Service Company of Colorado

ATTN: Mr. Robert 0. Williams, Jr.

Vice President, Nuclear Operations

Post Office Box 840

Denver, Colorado 80201-0840

Gentlemen:

SUBJECT:

INSPECTION N0. 50-267/87-04

Enclosed is the report of the team inspection conducted by Mr. G. T. Hubbard

and other NRC representatives en January 26-30, 1987, at the Fort St. Vrain

Nuclear Generating Station, Platteville, Colorado, of activities authorized by

NRC License DPR-34. The team's findings were discussed with you and members of

your staff at the conclusion of the inspection. The inspection reviewed your

implementation of a program for establishing and maintaining the qualification

of electric equipment within the scope of 10 CFR 50.49. Within these areas,

the inspection consisted of examination of selected prccedures and records,

interviews with personnel, and observations by the inspectors.

The inspection determined that you have implemented a program to meet the

requirements of 10 CFR 50.49 except for the deficiencies identified in the

enclosed inspection report. The two deficiencies, summarized in Appendix A,

are classified as Potential Enforcement / Unresolved Items and will be referred

to the Region IV Office for further action. One deficiency involved failure

to document qualification of first generation Rockbestos coaxial cable and the

other deficiency involved failure to establish nualification of certain Raychem

splice configurations installed in the plant.

,

Five additional concerns are classified as Open Items.

Three of these items

require action by you and will be reviewed during a future NRC inspection.

The remaining two items involve Region IV review of the implementation of your

EQ maintenance and procurement programs. Details of the deficiencies and

concerns are discussed in the inspection report.

Your corrective actions regarding the deficiencies and concerns identified in

the enclosed inspection report should not be delayed pending either a future

NRC inspection or further actier by the NRC regional office.

8704070313 870403

PDR

ADOCK 05000267

G

PDR

- - -

-

-

-

-

- -

_ _ _ _ _

_

.,

,

'

.

,

.

.

Public Service Company of Colorado

-2-

April 3, 1987

In addition to correcting the deficiencies and concerns identified during the

inspection, you should also complete the outstanding EQ activities identified

during the inspection entrance meeting. These items include, but are not

limited to, completion of six qualification binders, verification of phone

conversation records, and completion of plant ir.stallation and maintenance

activities.

'We are available to discuss any auestions you have concerning this inspection.

Sincerely,

,

/,9fh?

-

Ellis W. Merschof

Acting Chief

Vendor Program Bra ch

Division of Quality Assurance, Vendor

and Technical Trainirg Center Program:

Office of Inspection and Enforcement

Enclosures:

1.

Appendix A-Potential Enforcement /linresolved Items

2.

Inspection Report No. 50-267/87-04

,

..

.

.-

.

.

<

.

APPENDIX A

Potential Enforcement / Unresolved Items

As a result of the equipment qualification inspection conducted on January 76-30,

1987, the following items will be referred to NRC Region IV as Potential Enforce-

ment / Unresolved Items (paragraph references are to detailed portions of the

inspection report).

1.

Contrary to the requirenents of paragraph (f) and (k) of 10 CFR 50.49 and

Section 5.2.2 of the D0R Guidelines, at the start of the inspection, Public

Service Company of Colorado (PSC) failed to adequately establish qualifi-

cation of Rockbestos coaxial cable installed at Fort St. Vrain (FSV).

Specifically PSC failed to establish similarity between the first generation

cable installed in the plant and the later generation cables which were

tested in the qualification reports included in the qualification binders.

(Paragraph 4.E.(1), 50-267/87-04-03)

2.

Contrary to the requirements of paragraph (f) of 10 CFR 50.49, PSC did not

adequately establish qualification of certain Raychem splices installed

in FSV. PSC had not documented that certain installed splices were iden-

tical to the qualification test specimens used to establish qualification

l

in the binders. Specifically, the inspectors observed splices installed

in plant equipment where the shin sleeve extended past the splice sealing

sleeve and there was no seal between the splice sealing sleeve and the

cable insulation.

(Paragraph 4.F.(1), 50-267/87-04-06)

'

,

.

.

.-

_-

--

e

-

--

,

..

..

, - .

._

.

Public Service Company of Colorado

April 3, 1987

DISTRIBUTION:

  • W N1MidD3$3

NRC PDR

Local PDR

VPB Reading

DQAVT Reading

JTaylor

BGrimes

HMiller

EMerschoff

UPotapovs

GHubbard

0Gormley

JStone

LParker

ARJohnson, RIV

DENoman, RIV

JEBess, RIV

REHall, RIV

JGagliardo, RIV

JPJaudon, RIV

RIreland, RIV

HBerkow, NRR

PShemanski, NRR

KHeitner, NRR

MYost, INEL

JHanek, INEL

JGrossman, SNL

REFarrell, SRI, FSV

RIV DISTRIBUTION:

R&SPB

MIS System

RSTS Operator

RIV File

DRSP

RDMartin, RA

RSB

Project Inspector

DWeiss,RM/ALF

V'

  • See previous page for concurrences.

M

6 t#

/T

Yl

a

OFC

VPB:DQAVT
SC/VPB:DQAVT :ABC/VPB:DQAVT : REGION IV
DIR: . _ _'____:______

______:________________:-_____________:______________:______________:..

NAME :GTHubbard: sam * :UPotapovs*

EWMerschoff*
REIreland
B

e

______________:_____________

_ _ _ _ _ _ : _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ : _ _ _ _ _ _ _ _ _ _ _ _ _ _ : _ _ _

DATE :3/25/87

3/27/87
3/30/87
3/31/87

J

.,

.

.

.

.

O

Public Service Company of Colorado

April 3,1987

DISTRIBUTION:

DocketFile(50-267)

NRC PDR

Local PDR

VPB Reading

DQAVT Reading

JTaylor

BGrires

HMiller

EMerschoff

UPotapovs

GHubbard

0Gormley

JStone

LParker

,

ARJohnson, RIV

.;

DENorman, RIV

JEBess, RIV

REHall, RIV

JGagliardo, RIV

JPJaudon, RIV

RIreland, RIV

HBerkow, NRR

PShemanski, NRR

KHeitner, NRR

MYest, INEL

JHanek, IMEL

JGrossman, SNL

REFarrell, SRI, FSV

RIV DISTRIBUTION:

R&SPB

MIS System

RSTS Operator

RIV File

DRSP

RDMartin, RA

RSB

Project Inspector

DWeiss,RM/ALF

4' ,'

  • See previous page for concurrences.

f

, ,,

'

OFC

VPB:DOAVT
SC/VPB:00AVT
ABC/VPB:DQAVT : REGION IV
DIR:

.._ __:________________:______________:.._______.____:______________:_.

. . _____:______. _____

NAME

GTHubbard: sam * :UPotapovs*
EWMerschoff*
REIreland
B

- e

-

______:________________:..____________:._____________: ...___________:______________:_ .__________

DATE

3/25/87
3/27/87
3/30/07
3/31/87
'// 7_/87

.

..

-

_

_ .