s' Docket Nos.: 50-327 and 50-328 Mr. Steven A. White 10 JUN 1936 Manager of Nuclear Power Tennessee Valley Authority 6N 38A Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801

Dear Mr. White:

SUBJECT:

AMENDMENT REQUEST FOR A CHANGE TO THE TECHNICAL SPECIFICATION FOR THE PURGE AND VENT LINE OPENING LIMITS By letters dated September 17, 1982, July 1, 1983, and September 22, 1983, the Tennessee Valley Authority proposed certain changes to the Sequoyah Nuclear Plant, Units' I and 2, Technical Specifications for the purge and vent line opening limits. The proposed change would permit an increase in the flow rate of ' air purged from the containment during normal operation.

The staff has-reviewed these proposed changes to the Technical Specification and has determined that the changes are unacceptable. The basis for this finding is detailed in the enclosed safety evaluation.

If you should have any questions, please contact the Project Manager, Carl Stahle, at (301) 492-7385.

Sincerely,

\\b\\

B. J. Youngblood, Director PWR Project Directorate #4 Division of PWR Licensing-A

Enclosure:

As stated cc: See Next Page

  • i TION:

(NRCPDR mr JPartlow BGrimes Local PDR Edordan PRC System OELD NSIC ACRS(10)

PWR#4 R/F JHolonich CStable MDunca PWRM R-A PWR PWR-A R {gDPWR-A P

/DPWR-A JHoh ch:lr CStable M qcan B

ngblood 6/p /86 6/q/86 6/y /86 6/ V /86 8606130303 860610 PDR ADOCK 05000327 P

PDR

I n

p or

/

o UNITED STATES

~,,

8' NUCLEAR REGULATORY COMMISSION g

o r a WASHINGTON, D. C. 20555

/

10 JUN 1986 Docket Nos.: 50-327 and 50-328 Mr. Steven A. White Manager of Nuclear Power Tennessee Valley Authority 6N 38A Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801

Dear Mr. White:

SUBJECT:

AMENDMENT REQUEST FOR A CHANGE TO THE TECHNICAL SPECIFICATION FOR THE PURGE AND VENT LINE OPENING LIMITS By letters dated September 17,1982, July 1,1983, and September 22, 1983, the I

Tennessee Valley Authority proposed certain changes to the Sequoyah Nuclear i

Plant, Units 1 and 2, Technical Specifications for the purge and vent line opening limits. The proposed change would pemit an increase in the flow rate of air purged from the containment during nomal operation.

The staff has reviewed these proposed changes to the Technical Specification and has detemined that the changes are unacceptable. The basis for this finding is detailed in the enclosed safety evaluation.

If you should have any questions, please contact the Project Manager, Carl Stahle, at (301) 492-7385.

Sincerely,

/

/ l,B. J. Youngblood, Director PWR Project Directorate #4 Division of PWR Licensing-A

Enclosure:

As stated cc: See Next Page

.,,. -. - - - - +. - -

)

'o Mr. S. A. White Tennessee Valley Authority Sequoyah Nuclear Plant cc:

Herbert S. Sanger, Jr...Esq.

Tennessee Department of Public General Counsel Health Tennessee Valley Authority ATTN:

Director, Bureau of 400 West Summit Hill Drive, E 11B 33 Environmental Health Services Knoxville, Tennessee 37902 Cordell Hull Building Nashville, Tennessee 37219 Mr. K. W. Whitt Mr. Michael H. Mobley, Director Tennessee Valley Authority Division of Radiological Health 400 West Summit Hill Drive, E3A8 T.E.R.R.A. Building Knoxville, Tennessee 37902 150 9th Avenue North Nashville, Tennessee 37203 Mr. Bob Faas Westinghouse Electric Corp.

County Judge P.O. Box 355 Hamilton County Courthouse Pittsburgh, Pennsylvania 15230 Chattanooga, Tennessee 37402 Mr. Jerry Wills Tennessee Valley Authority i

I SN 1338 Lookout Place Chattanooga, Tennessee 37402-2801 Mr. Donald L. Williams, Jr.

Tennessee Valley Authority 400 West Summit Hill Drive, W10885 Knoxville, Tennessee 37902 Resident Inspector /Sequoyah NPS c/o U.S. Nuclear Regulatory Commission 2600 Igou Ferry Road Soddy Daisy, Tennessee 37379 Regional Administrator, Region II U.S. Nuclear Regulatory Commission, 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 I