p,,c uo),

/

+#

lo, UNITED $TATEs NUCLE AR REGULATORY COMMISSION y

3 a

WASHINGTON, D. C, 20555 1

e n

A FEB4 1997 HEMORANDUM FOR

Jarnes H. Snierek, Chainnan Conrtittee to Review Generic Requirements FROM:

Guy A. Arlotto, Director Division of Engineering Safety. RES

SUBJECT:

PROPOSED REY!SION 2 TO REGULATORY GV!0E 1.100, "SE!$MIC OVALIFICATION OF ELECTRIC AND MECHANICAL EQUIFMENT FOR NUCLEAR POWER PLANTS" The Comittee to Review Generic Requirements (CkGR) in its 97th meeting on October 1, 1986, reviewed the subject reCulatory guide and provided its recomendation as documented in CRGR Meeting Minutes dated October 15, 1986.

Enclosed is a copy of Proposed Revision 2 to R.G. 1.100 Draft (4 dated December 4,1986, which incorporates the CRGR recomendations, and also a marked-up copy of Draft #3 which shon tite changes made in Draft #4 of proposed Revision 2.

Also enclosed is a copy of the draft letter which will accompany the 4

regulatory guide when it is issued for pub c coeren,

y A.br10tto, Director Divisir, of Engineering Safety. RES

Enclosures:

As stated

Contact:

Satish K. Aggarwal 443-7840 cc: w/ enclosure H. Denton J. Taylor W. Olmstead E. Beckjord fjjlOf@ga 801007 WElssa 7-73 4 ppg

Division 1 Regulatory Guide 1.100 Proposed Revision 2 (date)

REGULATORY GU10E DISTRIBUTION LIST (DIVISION 1)

L Your attention is directed to the change in the title of the attached proposed i

Revision 2 to Regulatory Guide 1.100. "Seismic Oualification of Electric and Mechanical Equipment for Nuclear Power Plants." Revision 1 of this guide covered electric equipment only. This proposed revision also covers mechanical equipeent. Specifically, this proposed regulatory guide covers two categories of equipment:

(1) safety-related electric (Class 1E) r equipment and safety-related mechanical equipeent and (?) eculpment whose failure could prevent the satisfactory accomplishment of safety functions, q

t This regulatory guide endorses IEEE Std 344-1987. "Recomended Practices for Seismic Qualification of Class IE Equipment for Nuclear' Power Generacing d

Stations." with two exceptions. This standard recognizes the use of experience

.i data for seismic qualification.

Section 8.3 and Section 9 of IEEE Std 344-1987 b

provide guidance on the use of experience data. The NRC staff believes that this approach is consistent with the proposed resolution of Unresolved Safety

[4 Issue (US!) A 46 (NUREG-----).

t While coments and suggestions are encouraged in all areas, coments are specifically requested on the consistency of IEEE Std 344-1987 with the

{

proposed resolution of US! A 46.

l Written cceents may be submitted to the Rules and Procedures Branch. Division of Rules and Records. Office of Administration. U.S. Nuclear Regulatory j

Comission. Washington. DC 20555. Coments may also be delivered to Poem 4000. Maryland National Bank Building. 7735 Old Georgetown Road Bethesda.

4 Maryland, from 8:15 AM to 5:00 PM. Copies of coments received may be

'f examined at the NRC Public Document Room. 1717 H. Street. NW. Washington. DC.

Coments will be most helpful if received by Guy A. Arlotto. Director l[

Division of Engineerin Safety 1i Office of Nuclear Regu atory Research lof tf

'[

i 1