e Le Corportte Industrirl Hygiene & Safety Departrnent 131 G1
- GOODYEAR AEROSPACE CORPORATION 1210 Massillon Road Akron, Ohio 44315-0001 11 August 1986 Ref:CIHS.2141-U. S. Nuclear Regulatory Commission Attention: Bruce Mallett, PhD Region III, Material License Section 799 Roosevelt Road Glen Ellyn, IL 60137
Subject:
Results et Vingfoot Lake Soil Analysis
Reference:
2/.11/86 memo to B.S. Mallett. PhD from D. E. Glechorn
Dear Dr. Hallett:
Attached are the results of the three soil samples taken at WFL and sent to Bolton & Galanek for analysis. As the results indicate, there is no
{
specific activity or contamination in any of the three locations.
This memo and its attachments will answer question #4 of the previous July 18, 1986 status update report.
If there are any questions please contact me.
Very truly yours, J
j Daniel E. Glegl rn, CSP, Manager Corporate Industrial Hygiene & Safety (216) 796 4180
/J cc JV Pflaum RECElVED AUG 161986 ggpqg828988dg, namu n' AUG 14 W c
i
~ c o
BOLTON & GALANEK, INC.
Consultants Radiochemistry & Health Physics P.O. Box 366 M.I.T. Branch Boston, MA 02139 Tel. (617) 253 2180 AuguJ t 6, 1986 a
Geodyear Aerospace Corp.
l 1210 Massillion Road Akron, OH 44315 l
l A t ten tion J.V.
Pflaus, Dept. 131 C1 The following results were obtained from the analysis of the soil specimens submitted to this labora tory for uranium and to tal ac tivity analysis tr fluoriestric and radiome tric techniques:
J' Sample ID Total Uranium To tal ac tivi ty (pC1/ gram)
(pci/ gram)
- 1. Main trench
< 0.036
< 0.45 2.
Shower line
< 0.036
< 0.45
- 3. Hof fman Sep tic
< 0.036
< 0.45 l
Fluorome tric me thod of analysis was used for to tal uranium.
A low bcckground alpha /bc ta gas flow proportional counter tha t is calibra ted with NBS certified s tandards was used for the tutal activity analysis.
The loss than values are the minimum de te c ta ble activities for the amount of se:ple analysed and the time counted.
d-7d4%up Hurray M.
Bolton, J Radiochemist R E C E ttf E D G A C 7,(4 h[
Mitchell S. Galanek AUG 111986 a sith Physicist ce;,o;.. r ~
e I
v k
'ay
. + -
l
' 4 Jap:';
- t:y,jj..if.f.(:'
,,,h*/ 'ig,* /j [ ;p g ;,.g,.: : p
'. I;.12; *.J.k,'b <J j 's. 5';,'A','r.hs..[4 [ [ * *J:'s'-);I"..':+' i.*,. !d+h":;
I,N.*j..
i e
e 4
4
- p.
- ....p
- +Q c.. 4 ; _ %.,,. w.. ;r..
.j y. 3:c. :m..... ri;g.1. g..
... g..g.,.
- g;.....
\\
"PWN.Y.%dtM.+ t**.M '"14**=#4#5tf*'"
g +'ti;;.;. s:JW5g; G.i.0#W%TC'gHg#g.y f.
t I
}6'gg&qgg),QQOlOyffg&]f .'. ';W.;-l.Ni,';;..i.vhi.%
M E' I N,hl3[4 !=
46i g
EM Blij @@phy i
m g
lc ye n, y
s gi a ly,M!g gufq )ag AblMM$,,$,,M= @.e.M M,.d b
. 4 4. 4; u a m n n
n v:
m
.~,e w.
m
%, oW-J N il a e.e. _;p m.1 g g rt W:
p,,yr e
p e
g A o
H y
s
'o s
.?
i u) g if..
g
'An i I
a g
n g.c k
W y >
r-
.. y. s :
4 jQ -
NE
[...
}
f.
,- v j% y
.2c. g:, :.- -..,,. ' ',g.m..
gd
~
,~
mf
,g.
M'.',b 6
- m. 6 A ti +[e.
a e6 3 W -*
e.meuS. wN
- &a, p J
,,1,..gi, d r*,J.7,%d' ','.,.: :A../;,n p f.., ; n'. g..- f tg *..:.:,, :.v,.yl, g gi 06 -+Li?.nt'41: N.'.U*i i, h.42.:Q t.).J g,r.;.*c4 y.
)
f l
.e
},-
]
July 22, 1986 s
BOLTON & GALANEK, INC.
Bldg 20C Room 108 18 Vassar Street Cambridge, Ma 02139 Attn Mr. Galanek i
i.
Subject:
Analy=is of Soil Samples from Wingfoot Lake Facility Enclosed are three scil san.ples from our Wingfoot Lake CEO facil-ity.
Please analyze each sample for total uraniu4 (U-238} con-tent and total activity.
Please report the results in p/Ci per gram of soil. Any questions concerning the samples, please con-tact the writer on (216) 796-7299, i
Soil samples excluded in this shipment are
+
1.
4' Main trench (5' deep) 2.
Showar line area remottal 3.
Hoffman (septic) filter bed W
f, W
John V. Pflaum, CIH Industrial Hygienist Senior
/